PA-110

advertisement
Pressure Transducers
with Amp.
Thank you for purchasing NIDEC COPAL
ELECTRONICS CORP. product. In order to use the
product correctly and most appropriately, please
completely read this manual before use and keep it for
future reference. Also, Please keep the instruction
manual for future reference.
PA-110
For more details information please ask for the nearest
distributor or the following sales center.
NIDEC COPAL ELECTRONICS CORPRATION
INSTRUCTION MANUAL Ver.1.1
Nishi-Shinjuku Kimuraya Bidg.
7-5-25 Nishi-Shinjuku Shinjuku-ku Tokyo 160-0023, Japan
Phone:
(03)3364-7055
Handling Notes
… Misuse or mishandling this product may result in injuries and other physical loss or damage.
Part Number Designation
PA ― 110 ― 102 D ― 005
Part name
PA-110
Rated pressure range
102:0∼100kPa
Pressure reference
D:Differential(Gauge)
Supply voltage
005:Supply voltage 5V
012:Supply voltage 12V
Piping
When inserting the tube to the pressure port, please insert it until hitting the end
of port.
It will cause air leak if the insertion of the tube is in the middle of the port.
Hose clamp
In this situation, please do not apply excessive force to the bottom of the port.
Tube
We recommend using the hose clamp for clamping the tube.
Example of piping
※Recommended tube : Inner Diameter φ3.5,
Outer Diameterφ6.5 silicon tube.
1
Internal Circuit
Voltage to current
conversion circuit
Power
Amplifier
circuit
Pressure
Pressure
Output
P.T
Common
P.T:Pressure transducer
Outline Dimentions(Unit:mm)
〈Outline〉
1
30°
P o w er ( + )
φ4.5
C o m mon
φ5.5±0.1
Ou tp u t
A P or t
4
17
B P or t
P ressure port( 1/2 )
Output Connect
Case1
(PPS)
Plug
TYCO ELECTRONICS AMP CO.,LTD
AMP Econoseal J Series〈MarkⅡ〉
Plug Housing
174357−2
Double Lock Plate
174358−1
Contact
Seal Ring
Label
(Polyestel)
8.5
19
37
55
Laser marking
Model,
Lot.No.
Metal collar insert
(Copper pyrites)
Case2
(PPS)
36
13.5
11.5
50
2−φ5.5
64
16
33
3
〈Outline〉
Download