Eastern Creek Pollution Monitoring Data

advertisement
Protection of the Environment Operations Act 1997
Environment,
Climate Change
& Water
Annual Return
EDL LFG (NSW PTY LTD
A
Statement of Compliance
- Licence Details
ALL licence holders must check that the licence details in Section A are correct.
lf there are changes to any of these details you must advise the EPA and apply as soon as
possible for a variation to your licence or for a l¡cence transfer.
Licence variation and transfer application forms are available on the EPA website at:
htto://www.environment.nsw.oov.au/licensinq, or from regional offices of the EPA, or from the
Operations Service Centre on telephone 133 372.
lf you are applying to vary or transfer your licence you must still complete this Annual Return.
Al
Licence Holder
Licence Number
10042
Licence Holder
EDL LFG (NSW PTY LTD
Trading Name (lf applicable)
37 070 941 794
ABN
A2
Type of Licence
Sched Dev Work/Prem Based Sched Activity
A3
Premises to which Licence Applies
common name (if
any)
premises
EASTERN CREEK WASTE MANAGEMENT CENTRE
WALLGROVE ROAD, EASTERN CREEK, NSW
A4 Activities to which Licence
Applies
Scheduled Activity
Electricity generation
A5
Other Activities
Chemical Storage Facilities
Waste Activities
A6 Fee-Based Activity Glassifications
Note that the fee based activity classification is used to calculate the administrative fee.
Fee.based activity
Activity scale
Unit of measure
Generation of electrical power from gas
>0-
Gwh generated
Licence 10042
302098
250
Page 0
of
15
Annual Retu¡'n
EDL LFG (NSW) PTY LTD
A7
Assessable Pollutants (Not Applicable)
Protection of the Environment Operations Act 1997
Annual Return
EDL LFG (NSW PTY LTD
B
Monitoring and Complaints Summary
81
Number of Pollution Gomplaints
Number of complaints recorded by the licensee during the reporting period (as
required by condition M4 of the licence).
Environment,
Climate Change
& Water
Ni1
lf no complaints were received enter nil.
B2
Concentration Monitoring Summary
For each monitoring point identified in your licence, (see licence conditions M2 and R1), complete all the
details for each pollutant listed in the tables provided below.
lf concentration monitoring is not required by licence conditions M2 and R1, no tables will appear below.
Note that this does not exclude the need to conduct appropriate concentration monitoring of assessable
pollutants as required by load-based licensing (if applicable).
Licence 10042
302098
Page 0
of
15
Protection of the Environment Operations Act 1997
Annual Return
NSW
EDL LFG (NSW PTY LTD
Discharge & Monitoring Point
GOVERNMENT
I
301169 East 6254713 North
Gas engine exhaust stack labelled "GM1" on drawing number 902.84.002 Rev 0.
Pollutant
Unit of
measure
No. of samples
required by
licence
1
No, of samples
you collected
and analvsed
degrees Celsius
Nitrogen Oxides
milligrams per
cubic metre
1
1
milligrams per
1
1
1
1
Sulphur dioxide
Mean
Highest
of samples
sample value
441,
1
Temperature
Volatile organic
compounds
Lowest
sample value
380
s10
450
0
.44
cubic metre
milligrams per
'L
.6
cubic metre
6.9
Oxygen (O2)
percent
1
1
Moisture content
percent
1
1
Carbon monoxide
milligrams per
cubic metre
l
1
610
Carbon dioxide
percent
l-
1
I2
Velocity
metres per
second
1
l
Volumetric flowrate
cubic metres
1
1
per second
Dry gas density
milligrams per
cubic metre
1
1
Molecular weight of
stack gases
grams per gram
1
l_
Sulfuric acid mist and
sulfur trioxide (as S03
milligrams per
cubic metre
7.5
I
630
660
t2 .6
12.3
43
1.5 (dry)
(wet)
1, .7
1, 360, 000
30.4 (dry)
mole
1
7-2
1
29 .4
(wet
)
1.2
equivalent)
Licence 10042
302098
Page0ofl5
Protection of the Env¡ronment Operations Act 1997
Annual Return
NSW
EDL LFG (NSW) PTY LTD
GOVERNMENT
Environment,
Climate Change
& Water
Discharge & Monitoring Point 2
301169 East 6256713 North
Gas engine exhaust stack labelled "GM2" on drawing number 902-8A-002 Rev 0.
Pollutant
Sulfuric acid mist and
sulfurtrioxide (as S03
Unit of
measure
milligrams per
cubic metre
No. of samples
required by
licence
No. of samples
you collected
and analvsed
Lowest
sample value
1
1
Mean
Highest
of samples
sample value
15
equivalent)
Molecular weight of
stack gases
Dry gas density
grams per gram
1
29.2 (wet)
30.3 (dry)
1
mole
milligrams per
t-
1,350,000
1
cubic metre
Volumetric flowrate
Velocity
1.3 (wet )
1,.2 (dry)
cubic metres
per second
1
1
metres per
1
1
percent
1
1
1,1,
milligrams per
1
1
1000
34
second
Carbon dioxide
Carbon monoxide
.7
11.
I
1000
11.9
1000
cubic metre
8.4
Moisture content
percent
1
1
Oxygen (02)
percent
1
1
mìlligrams per
l_
1
B.B
t_
1
o
1
1
1
l_
Sulphur dioxide
7
'7.L
7
cubic metre
Volatile organic
milligrams per
compounds
cubic metre
Nitrogen Oxides
milligrams per
370
.04't
4t-0
470
cubic mehe
Temperature
Licence 10042
302098
degrees Celsius
440
Page0oll5
Protection of the Environment Operations Act 1997
Annual Return
NSIw
EDL LFG (NSW) PTY LTD
Environment,
Climate Change
& Water
Discharge & Monitodng Point 3
301169 East 6256713 North
Gas engine exhaust stack labelled "GM3" on
Pollutant
Unit of
measure
number 902-8A-002 Rev 0,
No. of samples
required by
licence
No, of samples
you collected
and analysed
Lowest
sample value
Temperature
degrees Celsius
1
1
447
Sulphur dioxide
milligrams per
cubic metre
1
1
11tr,
Oxygen (02)
percent
1
1
Volatile organic
compounds
milligrams per
1
l-
cubic metre
l
l_
1
l_
Nitrogen Oxides
milligrams per
cubic metre
Itlloisture content
percent
Carbon dioxide
percent
Sulfuric acid mist and
sulfur trioxide (as SO3
equivalent)
cubic metre
milligrams per
6
0.084
380
410
8.6
't2.6
12 .6
1
1
1
29.3 (wet )
30.4 (dry)
1
1,360,000
Dry gas density
milligrams per
cubic metre
1
Volumetric flowrate
cubic metres
per second
1
1
1
1
1
1
7.4
'L.2 (wet
Carbon monoxide
milligrams per
cubic metre
Licence 10042
302098
1,2.7
1
mole
metres per
440
1
grams per gram
second
6.4
6.L
1
lVlolecular weight of
stack gases
Velocity
Highest
sample value
Mean
of samples
)
1.1 (dry)
32
s10
520
520
Page0ofl5
Protection of the Environment Operalions Act 1997
Annual Return
Environment,
Climate Change
& Water
NSW
EDL LFG (NSW) PTY LTD
GO'VERNMENÍ
Discharge & Monitoring Point 4
301169 East 62567'13 North
Gas engine exhaust stack labelled "GM4" on drawing number 902-8A-002 Rev 0
Pollutant
Sulfuric acid mist and
sulfur trioxide (as S03
equivalent)
Molecular weight of
stack gases
Dry gas density
Unit of
measure
milligrams per
cubic metre
grams per gram
No, of samples
required by
licence
1
No, ofsamples
you collected
Lowest
sample value
milligrams per
Highest
sample value
and analvsed
7.9
1
29 .4
1
1
1
1
Velocity
cubic metres
per second
1
1
metres per
second
Carbon dioxide
Carbon monoxide
percent
milligrams per
1
1
1
1
1
t_
t_
Moisture content
percent
1
l_
Oxygen (O2)
percent
1
1"
Sulphur dioxide
milligrams per
cubic metre
1
1
Volatile organic
compounds
milligrams per
cubic mehe
1
Nitrogen Oxides
milligrams per
cubic metre
1
1
Temperature
degrees Gelsius
1
1
302098
3 (wet)
2 (dry)
33
L2.4
cubic metre
Licence 10042
)
1,350,000
1
Volumetric flowrate
(wet
30.4 (dry)
mole
cubic metre
Mean
of samples
730
.5
12 .4
1,2
7s0
760
8.1
6.4
6.4
6.s
4-7
0.067
1
380
41,0
430
433
Page0of15
Protection of the Environment Operations Act 1 997
Annual Return
!*çJt!t
EDL LFG (NSW PTY LTD
Environment,
Climate Change
& Water
Monitoring Point 5
301169 East 6256713 North
Landfill gas supply line labelled "supply gas" on drawing number 902.8A.001 Rev 2.
Pollutant
Temperature
Unit of
measure
No. of samples
required by
licence
No. of samples
you collected
and analvsed
1
t_
22
1
1
110
Volatile organic
milligrams per
cubic metre
Oxygen (02)
percent
1
1
Moisture content
percent
1
1
Carbon dioxide
percent
1
1
1
1
metres per
second
Volumetric flowrate
cubic metres
per second
1
l_
Dry gas density
milligrams per
cubic metre
1
1
Molecular weight of
stack gases
grams per gram
1
1
2.6
Highest
sample value
Mean
of samples
degrees Celsius
compounds
Velocity
Lowest
sample value
2.7
2.6
1
32-6
32.7
32 -7
L3 .4
1.0
1-.25
mole
27 -9
(wet)
28 .0
(drY)
Discharge & Monitoring Point 6
301169 East 6256713 North
Landfill gas flare labelled "flare" on drawing number 902.84.002 Rev 0.
Pollutant
Volumetric flowrate
Unit of
measure
cubic metres
per second
Temperature
degrees Celsius
No, of samples
required by
licence
1
1
No. of samples
you collected
and analvsed
Lowest
Mean
sample value
of samples
U
1.1
U
745
Highest
sample value
E}3 Volume or Mass Monitoring Summary
For each monitoring point identified in your licence, (see licence conditions M6 and R1), complete the
details of the volume or mass monitoring indicated in the tables provided below.
lf volume or mass monitoring is not required by licence conditions M6 and R1, no tables will appear below.
Note that this does not exclude the need to conduct appropriate concentration monitoring of assessable
pollutants as required by load-based licensing (if applicable).
Licence 10042
302098
Page0ofl5
Download