POREX Barrier Technology™ ® Antimicrobial Porous Materials for Medical Devices Key Benefits Genuine Porex™ : It works. Every time. • Enhanced antimicrobial performance • Chlorhexidine widely used in healthcare as an antimicrobial agent • Chlorhexidine alloyed in porous polymer • Porous molded structures can be seamlessly integrated into medical devices • Porous plastic components for venting, filtering, wicking and diffusing applications • Can be used in airborne and fluid contact applications • Porex patented antimicrobial technology Bactericidal Virucidal Fungicidal The prevalence of hospital acquired infections has driven advances in antimicrobial technologies. In 2003, Porex developed antimicrobial porous media as an effective solution against bacteria and fungi. Continuing its history of innovation, Porex has now developed Porex Barrier Technology, a microbicidal technology that goes beyond inhibiting microbial growth on surfaces; it kills microbes in liquid and gas streams on contact. Porex Barrier Technology can be integrated into our porous media for venting, filtering, wicking, and diffusing applications for medical devices. It is effective against a broad spectrum of microbes, including gram positive and gram negative bacteria, virus, and fungi. Porex Barrier Technology can be applied in medical devices to help reduce infections caused by airborne and blood/fluid contact exposures. POREX Barrier Technology™ ® Antimicrobial Porous Materials for Medical Devices JIS Z2801:2000 Test Methodology The Japanese Industrial Standard JIS Z2801: 2000 or JIS Z2801 is an industrial standard method to quantify antimicrobial activity level of an antimicrobial surface, especially for a hydrophobic surface. The method provides reproducible quantitative results for both microbiostatic and microbicidal properties for solid surfaces. Staphylococcus aureus (gram pos) Product Initial CFU 24 hrs CFU % Reduction Log Reduction Negative Control 3.3 x 10 6 3.7 x 10 6 -13 -0.05 Standard Product (without CHX) 3.3 x 10 6 3.4 x 10 6 -2 -0.01 Barrier Technology (with CHX) 3.3 x 10 6 <200 >99.994 >4.22 Potential Applications Escherichia coli (gram neg) Product Initial CFU 24 hrs CFU % Reduction Log Reduction Negative Control 2.4 x 10 6 2.9 x 10 7 -1212 -1.12 Standard Product (without CHX) 2.4 x 10 6 2.8 x 10 7 -1075 -1.07 Barrier Technology (with CHX) 2.4 x 10 6 <200 >99.9915 >4.07 Liquid Filtration Liquid filtration testing was performed to measure the ability of Porex Barrier Technology to remove E. coli from a liquid stream. In this test a small disk was placed into a filter holder. The disk was challenged with 5.5 liters of water containing 690,000 CFU/ml of E. coli. The test was run at a flow rate of 1 liter per minute over a 5 minute and 30 second time period. Samples of the effluent were taken at 4 different time points during the test. The testing of the effluent samples showed no growth of E. coli. Escherichia coli Sample Time Volume (L) E. Coli Challenge Counts (CFU/ml) E. Coli Effluent Counts (CFU/ml) % Reduction 30 Sec 0.5 690,000 0 100 1 Min 30 Sec 1.5 690,000 0 100 3 Min 30 Sec 3.5 690,000 0 100 5 Min 30 Sec 5.3 690,000 0 100 Porex Corporation 500 Bohannon Road, Fairburn, GA 30213 USA info@porex.com T. +1 770 964 1421 F. +1 770 969 0954 Airborne Infections • Ventilator care devices • Respiratory care • Tracheal devices • Suction canisters • Central vacuum line systems • Drug delivery inhalers • Packaging • Sterilization vents & trays Blood/Fluid Contact Infections • Fluid management/ IV components • Catheters • Dialysis devices • Blood therapy devices • Safety syringe vents • Oral care devices • Minimally invasive surgical instruments www.porex.com 800.241.0195 Porex Technologies GmbH Strangenhäuschen 30, 52070 Aachen, Germany info@porex.de T. +49 241 910525-0 F. +49 241 910525-16 Porex Technologies Sdn Bhd Lot P.T. 74, Jalan Hulu Tinggi 26/6, Seksyen 26, Sektor A Hicom Industrial Park, 40400 Shah Alam, Selangor, Malaysia info_malaysia@porex.com T. +603 5191 3308 F. +603 5192 3308 ©2014 Porex Corporation. POREX is a registered trademark and Porex Barrier Technology is a trademark of Porex Corporation. All Rights Reserved. PXT-606-020812-01