RT-SDH-M01 B - RedBookLive

advertisement
MATRIX BRACKET SECURED WITH 2No
M27G16 FIXINGS (CRS) or TSL36G16 (HRS)
THERMA-QUILT
*2
*2
2No. SC32 FIXINGS
*2
RT-500 PROFILE
MATRIX BAR MSB-3600
TSC20G19 FOR CRS OR TSL36G19 FOR HRS
NOTE: FIXINGS SHOULD BE INSTALLED IN ALL
CORRUGATIONS AT EVES AND DRIP
T-FOIL PLUS SIDE LAP
SEALANT STRIP
*2
REVISIONS:
CA LT 17 1000S
LINER PROFILE
*2
*2
TYPICALLY 1200 mm CENTRES - MAX 1600 mm CENTRES
RT-BLOCK
and sealed as outlined in the relevant installation guide.
Horizontal Section Through Wall Construction
THE MATRIX SPACER SYSTEM WHEN
INSTALLED VERTICALLY TO INCLUDE THE
SPECIAL MATRIX VERTICAL BRACKETS AT
THE BASE AND HEAD OF THE ELEVATION,
PLUS AT EVERY 4TH CLADDING RAIL (OR
VIEW ON TOP OF MVB
THE MVB BRACKET SHOULD
BE INSTALLED WITH 4No
M27G16 FIXINGS, 2No
THROUGH THE LINER INTO
THE CLADDING RAIL, 2No
THROUGH MVB BRACKET
INTO THE MATRIX BAR.
Insulation: The Therma-quilt is to be installed below the Matrix bar from
head to base, where the elevation height exceeds the insulation roll length a
firm abutment between rolls is required. The Therma-quilt is supplied in
1200mm wide rolls, where Matrix brackets are less than 1200mm centres the
Therma-quilt should be slit on site to suit spacings. Insulation to be held up
by insulation retainer as per the relevant installation guide.
C
REFER TO CA GROUP TECHNICAL
DEPARTMENT FOR FURTHER
INFORMATION.
FIXING POINT METHOD TO HORIZONTAL LAID SHEET.
*2
MATRIX BAR (MSB-3600)
(BASE RAIL SPACING OF 2200mm
MAX PERMITTED)
SEE INSTALLATION GUIDE
FOR DETAILS ON INSULATION
RETAINER
MATRIX BAR
Table 2 - Wall U-values and depths - standard build-ups in bold
2 NUMBER WFC80 FIXINGS REQUIRED
PER RT-LOCKBLOCK.
*1 - RAIL
MATRIX BRACKET
SECURED WITH 2No
M27G16 FIXINGS (CRS)
or TSL36G16 (HRS)
T-STRIP 9x3
MAX 500 mm
TO BE LOCATED AT CENTRE OF
RT-SHEET WITH EQUAL DISTANT
FROM BOTH ENDS OF SHEET
RT-500
PROFILE
CA LT 17 1000S
LINER PROFILE
THERMA-QUILT
Spacer System: Matrix bar manufactured from 1.5mm thick galvanised steel.
Supplied in 3600mm standard lengths to suit roofing contractors
requirements. Matrix brackets manufactured from 1.6mm thick galvanised
steel c/w 3mm EPDM thermal break pad bonded to base are to be 'twist
locked' into position along the Matrix bar. Once in place the bars are
interlocked at the swaged end c/w splice plate and the positioned assembly is
fixed through the bracket base into the rails with 2No M27G16 self drilling
fasteners (TSL36G16 for hot rolled steel).
Outer Sheet: See Table 1 for material options for outer profile sheet.
RT-500 Panel snap-fix together and locate within the RT-block
allowing the panels to move completely free from frictional attrition during
thermal expansion and contraction. The RT-block is fixed directly to the
Matrix bar with two SC32 Fixing.
30 30
RT-LOCKBLOCK BEDDED ON GUN
GRADE BUTYL SEALANT IN THE
DRAINAGE CHANNEL AND FIXED
THROUGH WITH 2No WFC80
FIXINGS PER BLOCK
Materials specification
Liner Panel: CA LT 17 1000S 0.4mm thick (nominal) liner panel fixed to rails
with TSC20G19 CRS or TSL36G19 HRS self-drilling fasteners.
All liner panel end laps are to be sealed with T-strip 9x3 butyl strip sealant
and all liner panel side laps are to be sealed with 50mm wide T-foil Plus .
Bracket Ref
Therma-quilt
MSS-80 & MVB-80
TQ100
System Depth IR Reference
138mm
IR-75-40
MSS-100 & MVB-100
TQ120
158mm
IR-75-60
MSS-120 & MVB-120
TQ140
178mm
IR-75-80
MSS-140 & MVB-140
TQ160
198mm
IR-75-100
U-Value
MSS-160 & MVB-160
TQ180
218mm
IR-75-120
MSS-180 & MVB-180
TQ200
238mm
IR-75-120
MSS-200 & MVB-200
TQ220
258mm
IR-75-150
MSS-220 & MVB-220
TQ240
278mm
IR-75-180
U-values quoted based on average bracket spacings of 1400mm and bar spacing of 1200mm
CA Building Products
Evenwood Industrial Estate
Copeland Road, Evenwood
Co. Durham. DL14 9SF
T: 01388 834242 F: 01388 834711
E: technical@cagroup.ltd.uk
W: www.cagroup.ltd.uk
MATRIX BAR SPLICE PLATE
(MSP-135) FIXINGS USED
M27G16
REFER TO THE INSTALLATION
GUIDE FOR FIXING
INFORMATION.
Vertical Section Through Wall
Construction
*1 - Refer to TIP-406 on 'Thin gauge purlins' for the minimum thickness of purlins / cladding rails.
*2 - Additional fixing at end laps.
Table 1
System Guarantee
N/A*
Up to 25 Years
N/A*
Up to 40 Years
RT-500 Material Specification
0.8mm thick nominal mill finish aluminium
RT-Block
Black Polyamide
0.8mm thick nominal PVDF coated aluminium
Black Polyamide
0.8mm thick nominal stucco embossed aluminium
White Poliossimetilene
0.55mm thick nominal Colorcoat HPS200 Ultra coated steel
Black Polyamide
*Only project specific performance statements are available for this type of material / finish.
System Appraisal
LPCB: Tested in accordance with LPS 1181 and achieves grade
'EXT-B' certification. Certification No. LPCB 443a
Fire wall area: Designated 'AA' to BS476:Part 3:2004 with liner panel
being class '0' surface spread of flame to BS476:Part 7:1997
Acoustics: Please consult TIP-401 for weighted sound reduction (Rw)
figures
This specification drawing is for general guidance only and should be
guide.
MET AL GUT T ER
MA NU FAC TU RE R S
AS SOC IATION
TH E ME TAL C L AD DIN G & R OOFIN G
MA NU FAC TU RE R S ASS OCIA TION
THE NATIONAL FEDERATION OF
ROOFING CONTRACTORS LIMITED
BS I
TM
ISO 9001
FS 10446
EN 14782:2006
TITLE:
Utilising CA LT 17 1000S Liner Panel
and Matrix Spacer System
SYSTEM:
DRAWN:
CHECKED:
EH
DRAWING No:
DATE:
LD/SB
28 APRIL 2011
RT-SDH-M01
SCALE:
1:10 @ A3
REV:
B
GALV. SUPPORT ,
REFER TO DETAIL DRAWING
FOR FIXING INFORMATION
CA LT 17 1000S
LINER PROFILE
*2
T-FOIL PLUS SIDE LAP
SEALANT STRIP
MATRIX BRACKET SECURED WITH 2No
M27G16 FIXINGS (CRS) or TSL36G16 (HRS)
TSC20G19 FOR CRS OR TSL36G19 FOR HRS
NOTE: FIXINGS SHOULD BE INSTALLED IN ALL
CORRUGATIONS AT EVES AND DRIP
*2
*2
BRACKET 150mm FROM
PLAIN END OF MATRIX BAR
THERMA-QUILT
*2
*2
REVISIONS:
*2
20
150
MAX 250 mm
2No. SC32 FIXINGS
MAX 600 mm
CORNER FLASHING TO MATCH WALL CLADDING
MATERIAL, REFER TO DETAIL DRAWING FOR FIXING
INFORMATION
RT-BLOCK
MAX 600 mm
RT-500 PROFILE
1000 mm
1000 mm
MATRIX BAR (MSB-3600)
MAX 1200mm
MATRIX BAR 3600 mm
DIRECTION OF LAY
and sealed as outlined in the relevant installation guide.
Start and End of Bar and Bracket Requirements
O/A SYSTEM DEPTH
SEE TABLE 2
BRACKET
43 15
DEPTH
MATRIX BRACKET SECURED WITH 2No
M27G16 FIXINGS (CRS) or TSL36G16 (HRS)
T-FOIL PLUS SIDE LAP
SEALANT STRIP
CA LT 17 1000S
LINER PROFILE
*2
TSC20G19 FOR CRS OR TSL36G19 FOR HRS
NOTE: FIXINGS SHOULD BE INSTALLED IN ALL
CORRUGATIONS AT EVES AND DRIP
THERMA-QUILT
*2
*2
MATRIX BAR
(MSB-3600)
MATRIX BRACKET
SECURED WITH 2No
M27G16 FIXINGS (CRS)
or TSL36G16 (HRS)
*2
RT-BLOCK
2No. SC32 FIXINGS
MAX 1200mm
RT-500 PROFILE
MAX 1200 mm
MAX 1200 mm
MATRIX BAR (MSB-3600)
(BASE RAIL SPACING OF 2200mm
MAX PERMITTED)
Horizontal Section Through Wall Construction
Insulation: The Therma-quilt is to be installed below the Matrix bar from
head to base, where the elevation height exceeds the insulation roll length a
firm abutment between rolls is required. The Therma-quilt is supplied in
1200mm wide rolls, where Matrix brackets are less than 1200mm centres the
Therma-quilt should be slit on site to suit spacings. Insulation to be held up by
insulation retainer as per installation guide .
Spacer System: Matrix bar manufactured from 1.5mm thick galvanised steel.
Supplied in 3600mm standard lengths to suit roofing contractors
requirements. Matrix brackets manufactured from 1.6mm thick galvanised
steel c/w 3mm EPDM thermal break pad bonded to base are to be 'twist
locked' into position along the Matrix bar. Once in place the bars are
interlocked at the swaged end and the positioned assembly is fixed through
the bracket base into the rails with 2No M27G16 self drilling fasteners
(TSL36G16 for hot rolled steel).
Outer Sheet: See Table 1 for material options for outer profile sheet.
RT-500 panel snap-fix together and locate within the RT-block
allowing the panels to move completely free from frictional attrition during
thermal expansion and contraction. The RT-block is fixed directly to the
Matrix bar with two SC32 Fixing.
RT-BLOCK
30 30
Table 2 - Wall U-values and depths - standard build-ups in bold
2No. SC32 FIXINGS
*1 - RAIL
T-STRIP 9x3
RT-500
PROFILE
Materials specification
Liner Panel: CA LT 17 1000S 0.4mm thick (nominal) liner panel fixed to rails
with TSC20G19 CRS or TSL36G19 HRS self-drilling fasteners.
All liner panel end laps are to be sealed with T-strip 9x3 butyl strip sealant
and all liner panel side laps are to be sealed with 50mm wide T-foil Plus.
THERMA-QUILT
CA LT 17 1000S
LINER PROFILE
Vertical Section Through Wall
Construction
Bracket Ref
Therma-quilt
System Depth
IR Reference
MSS-80
TQ100
138mm
IR-75-40
MSS-100
TQ120
158mm
IR-75-60
MSS-120
TQ140
178mm
IR-75-80
MSS-140
TQ160
198mm
IR-75-100
MSS-160
TQ180
218mm
IR-75-120
MSS-180
TQ200
238mm
IR-75-120
MSS-200
TQ220
258mm
IR-75-150
MSS-220
TQ240
278mm
IR-75-180
U-Value
U-values quoted based on average bracket spacings of 1100mm and bar spacing of 1400mm
CA Building Products
Evenwood Industrial Estate
Copeland Road, Evenwood
Co. Durham. DL14 9SF
MET AL GUT T ER
MA NU FAC TU RE R S
AS SOC IATION
T: 01388 834242 F: 01388 834711
E: technical@cagroup.ltd.uk
W: www.cagroup.ltd.uk
TH E ME TAL C L AD DIN G & R OOFIN G
MA NU FAC TU RE R S ASS OCIA TION
THE NATIONAL FEDERATION OF
ROOFING CONTRACTORS LIMITED
BS I
TM
ISO 9001
FS 10446
EN 14782:2006
TITLE:
*1 - Refer to TIP-406 on 'Thin gauge purlins' for the minimum thickness of purlins / cladding rails.
*2 - Additional Fixing at liner end laps.
Table 1
System Guarantee
N/A*
Up to 25 Years
N/A*
Up to 40 Years
RT-500 Material Specification
0.8mm thick nominal mill finish aluminium
RT-Block
Black Polyamide
0.8mm thick nominal PVDF coated aluminium
Black Polyamide
0.8mm thick nominal stucco embossed aluminium
White Poliossimetilene
0.55mm thick nominal Colorcoat HPS200 Ultra coated steel
Black Polyamide
*Only project specific performance statements are available for this type of material / finish.
System Appraisal
LPCB: Tested in accordance with LPS 1181 and achieves grade
'EXT-B' certification. Certification No. LPCB 443a
Fire wall area: Designated 'AA' to BS476:Part 3:2004 with liner panel
being class '0' surface spread of flame to BS476:Part 7:1997
Acoustics: Please consult TIP-401 for weighted sound reduction (R w)
figures
This specification drawing is for general guidance only and should be
Utilising CA LT 17 1000S Liner Panel
and Matrix Spacer System
SYSTEM:
DRAWN:
CHECKED:
EH
guide.
DRAWING No:
DATE:
LD/SB
28 APRIL 2011
RT-SDV-M01
SCALE:
1:10 @ A3
REV: