Building Control (Field Installed) Zone Controller Retro-fit CV AHU, Application Specific Air Handler Units CV — Air Manager Sequence of Operation Note: The following is a sample of a typical sequence of operation that may be adapted for a particular project with a Constant Volume Air Handler. This is provided as a suggestion on how to write a sequence of operation for a specific project. The Air Handler Retrofit Controller (ARC) includes the ability for the operator to select some different sequences. Consult your Carrier representative if the sample sequence requires alterations. 4.3.6 Air Handler Retrofit Controller (ARC) 4.3.6.1 Sequence of Operation Descriptions — Constant Volume Sequence of operation for a Constant Air Volume air handler with a supply fan and slaved return fan, heating and cooling coil, CO2 damper override, economize damper control, and Unoccupied Free Cooling. A. General: The time schedule shall be indexed to the occupied mode based on a global or local time schedule, timed override command from the EMS operators station (local or remote), or if an occupant has pushed the override button on the thermostat. After a timed override has expired, the unit shall be indexed back to its unoccupied mode if the time schedule is still unoccupied, otherwise it shall remain in the occupied mode. During the unoccupied cycle, if the unoccupied heat or cool setpoints are exceeded, the unit shall start with its dampers closed until the unoccupied setpoints are no longer exceeded. B. Unoccupied Free Cooling (UFC): The unit shall be indexed to the Unoccupied Free Cooling (UFC) mode whenever the unit is unoccupied, the space temperature is at least 2°F above the occupied temperature setpoint and the outside air temperature is at least 8°F below the space temperature. Whenever the outside air temperature is greater than 60°F (operator adjustable) the algorithm shall lock out UFC. When the unit is indexed to the UFC mode, the supply and interlock return fan shall start, the economizer dampers shall open, and the mechanical cooling shall be disabled. UFC shall remain in effect until the space temperature is below the setpoint or outside air temperature rises above 60°F (operator adjustable). C. Heating Control: When the supply fan is on, the heating valve shall be modulated to maintain its occupied and unoccupied setpoints. The routine shall use the space sensor as the master sensor and the discharge sensor as the submaster sensor. When the supply fan is off, the routine shall modulate the heating valve to maintain a minimum duct temperature and help protect against freezing. D. Cooling Control: When the supply fan is on, the cooling coil valve shall be modulated to maintain its occupied and unoccupied setpoints. The valve shall be closed whenever the space temperature is below the cooling setpoint. The routine shall use the space sensor as the master sensor and the discharge sensor as the submaster sensor. The valve shall be closed whenever the supply fan is off, the system is indexed to UFC, or the unit is providing heat. E. Damper Control: The economizer dampers shall be modulated to maintain a space temperature that is between the heating and cooling setpoints. The mixed air damper control routine shall automatically determine the setpoint by reading the setpoint values and determining what value is between the heating and cooling setpoints. During the unoccupied cycle, the mixed air dampers shall be closed to outside and exhaust air and open to return air unless the dampers have been indexed to UFC. The minimum damper position shall be the greatest of the supplied configured minimum positions as applicable, from the IAQ routine or this routine, whichever is the greatest. When the supply fan is off, the mixed air dampers shall be kept closed to outside and exhaust air and open to return air. F. Indoor Air Quality (IAQ): Whenever the supply fan is on, the unit is in the occupied mode and the return CO2 rises above its adjustable setpoint, a PI loop shall calculate a new minimum damper position necessary to maintain the CO2 setpoint. As the CO2 level falls below its setpoint the routine shall lower its calculated value for the minimum damper position. IAQ shall be suspended whenever the average space temperature or return air humidity are outside the comfort limits. If the mixed air temperature falls below 48°F, the dampers shall be repositioned to maintain a minimum mixed air temperature of 48°F. The maximum damper position shall automatically be limited to a maximum position of 80% (operator adjustable) whenever the unit is indexed to the IAQ mode.