OHS017 Risk assessment completed by: Alex Macmillan Staff/student number: z3354957 OHS Risk Assessment and Control Form Faculty/Division: School/Unit: Analytical Centre : DVC Research Biomedical Imaging Facility (BMIF) Document number Initial Issue date Current version R07.01 3 23/02/2010 Current Version Issue date 11/02/2011 Next review date February 2012 For additional information refer to the OHS Risk Assessment and Control Procedure, the OHS Risk Rating Procedure and the Hierarchy of Risk Controls. Risk Assessment title:: Optical Microscopy Step 1: Identify the activity Describe the activity: Operation of confocal, epifluorescence, 2-Photon, Stimulated Emission Depletion (STED), and atomic force (AFM) microscopes and associated mercury lamps, scanners, lasers, cameras and computers. ___________________________________________________________________________________________________________________________________________________________________________________ Page 1 of 8 Risk Assessment and Control Form Uncontrolled document when printed Date Effective: 01/01/2007 Current Version: 2.6, 16/07/2008 Describe the location: Microscopes are located in Lowy Buillding LG 22 and LG 24. Step 2: Identify who may be at risk by the activity Operators of the microscopes will face the primary risk. Other microscopy users in the facility (trainees) will also face risk. As the hazardous presented by microscopes are spatially contained, they pose few risks to those outside the facility. Steps 3 to 7: Identify the hazards, risks, and rate the risks 1. An activity may be divided into tasks. For each task identify the hazards and associated risks. 2. List existing risk controls and determine a risk rating using the UNSW Risk Rating Procedure. 3. Additional risk controls may be required to achieve an acceptable level of risk. Re-rate the risk if additional risk controls used. Tasks Hazards Associated risks (Step 3) (Step 4) Risk rating with existing controls * Additional risk controls required Risk Rating with additional controls * (Step 5) (Step 6) (Step 7) Existing risk controls C Use of all microscopes: Electrical equipment (microscopes, halogen lamps, mercury lamps, scanners, cameras and computers) Possible electric shock Regular checks of power cords for fault, fraying or wear and regular electrical safety checks. Maintenance only performed by authorized BMIF Microscopy staff and microscope vendors. 4 L E R (Apply the hierarchy of risk controls) C L R M ___________________________________________________________________________________________________________________________________________________________________________________ Page 2 of 8 Risk Assessment and Control Form Uncontrolled document when printed Date Effective: 01/01/2007 Current Version: 2.6, 16/07/2008 Ergonomics Postural damage from extended periods of time working at microscope and computer Maintain good posture at all times whilst working at the microscopes and computers. Do not work at the microscope /computer for more than two hours without taking a break. 3 D M Glass slides and coverslips Cuts from broken glass Carry slides/coverslips in suitable container. Dispose of any broken slides/coverslips immediately in Sharps containers provided. Dispose of any used slides/coverslips correctly (Sharps containers). 2 C M Experiment specific chemicals and biological materials Possible exposure to toxic or hazardous chemicals or biological materials Specimens brought into the facility must be clean, dry, safe and enclosed/contained (eg mounted slide). Live cells must be transported correctly. Where applicable, OGTR regulations must be complied with and the specimens suitably contained. No hazardous chemicals will be allowed in the BMIF. No PC2 organisms will be permitted in the BMIF. 3 D M ___________________________________________________________________________________________________________________________________________________________________________________ Page 3 of 8 Risk Assessment and Control Form Uncontrolled document when printed Date Effective: 01/01/2007 Current Version: 2.6, 16/07/2008 Use of microscopes with mercury lamps Use of Imaging oil (Immersol) Skin and eye irritation. Dermititis from chronic exposure. Users instructed to wash hands when leaving facility (already included in PC2 controls). Users instructed to wash hands if there is skin exposure. 1 D L Mercury Lamp Mercury vapor exposure - from explosion of mercury lamp Obey rules of use regarding turning on and off, and monitoring the usage of mercury lamps - see SOP for details. If mercury lamps are unusually dim or flicker notify Area Supervisor immediately. Mercury lamp use should not exceed 200hours. When lamp usage approaches 200 hours of use the lamps are replaced by authorized BMIF staff only. If explosion occurs evacuate room immediately, shut door, place "no entry" sign across door and notify a member of BMIF staff (Alex Macmillan or Henry Haeberle) immediately. Maintenance only to be performed by authorized personnel. D 1* (if person al are evacu ated immed iately) L ___________________________________________________________________________________________________________________________________________________________________________________ Page 4 of 8 Risk Assessment and Control Form Uncontrolled document when printed Date Effective: 01/01/2007 Current Version: 2.6, 16/07/2008 Use of microscopes with lasers Lasers Eye damage from lasers (UV and visible lasers) Do not look directly at light source. Maintenance only to be performed by authorized personnel (Leica, Zeiss, and Olympus technical personal, and BMIF staff) Use of Microscopy area (LG22 and LG24) Room temperature and humidity Fluctuations in room temperature and humidity Problem currently being monitored and dehumidifiers currently in LG22 and LG24 * C = consequence L = likelihood R = risk rating E 5 M from the UNSW Risk Rating Procedure Step 8 Documentation and supervisor approval Completed by: (name) Henry Haeberle (signature) Authorized by: (name) (signature) Date: Step 9: Implement the additional risk controls identified Indicate briefly what additional risk controls from Step 6 above were implemented, when and by whom. Risk control: Date: Implemented by: Risk control: Date: Implemented by: Risk control: Date: Implemented by: Risk control: Date: Implemented by: Risk control: Date: Implemented by: Step 10: Monitor and review the risk controls It is important to monitor risk controls and review risk assessments regularly. Review is required when there is a change in the process, relevant legal changes, and where a cause for concern has arisen. Reviews could be scheduled on an annual basis. If the risk assessment has substantially changed a new risk assessment is warranted. Review date: Reviewed by: Authorised by: ___________________________________________________________________________________________________________________________________________________________________________________ Page 5 of 8 Risk Assessment and Control Form Uncontrolled document when printed Date Effective: 01/01/2007 Current Version: 2.6, 16/07/2008 Review date: Reviewed by: Authorised by: Review date: Reviewed by: Authorised by: Review date: Reviewed by: Authorised by: Review date: Reviewed by: Authorised by: Documentation It is a requirement that legal and advisory documentation that supports this risk assessment be listed. Such documentation includes Acts, Regulations, Australian Standards and Codes of Practice, where applicable. Australian National Standards: 1337.4:2004 Personal eye-protection - Filters and eye-protectors against laser radiation, 2211.1:2004 Safety of laser products ___________________________________________________________________________________________________________________________________________________________________________________ Page 6 of 8 Risk Assessment and Control Form Uncontrolled document when printed Date Effective: 01/01/2007 Current Version: 2.6, 16/07/2008 UNSW Concise OHS Risk Rating Table OHS697 What you need to do 1. Consider what can go wrong that can hurt someone 2. Determine what the most likely outcome would be - Consequences 3. Determine how likely those consequences are - Likelihood 4. Calculate the risk rating 5. Required action How severely could someone be hurt death or permanent disability to one or more persons hospital admission required medical treatment required first aid required injuries not requiring first aid CONSEQUENCES: Severe Major Moderate Minor Insignificant How likely are those consequences? expected to occur in most circumstances will probably occur in most circumstances could occur at some time is not likely to occur in normal circumstances may occur only in exceptional circumstances LIKELIHOOD: Almost certain Likely Possible Unlikely Rare CONSEQUENCES Insignificant 1 Minor 2 Moderate 3 Major 4 Severe 5 M H H VH VH M M H H VH Possible C L M H H VH Unlikely D L L M M H Rare E L L M M M LIKELIHOOD Almost certain A Likely B Risk level Required action Act immediately: Very high The proposed task or process activity must not proceed. Steps must be taken to lower the risk level to as low as reasonably practicable using the hierarchy of risk controls. Act today: The proposed activity can only proceed, provided that: (i) the risk level has been reduced to as low as reasonably practicable using the hierarchy of risk controls; High (ii) the risk controls must include those identified in legislation, Australian Standards, Codes of Practice etc. (iii) the risk assessment has been reviewed and approved by the Supervisor and (iv) a Safe Working Procedure or Safe Work Method has been prepared. (v) The supervisor must review and document the effectiveness of the implemented risk controls. Medium Act this week: The proposed task or process can proceed, provided that: _______________________________________________________________________________________________________________ Page 7 of 8 UNSW Concise OHS Risk Rating Table Effective date: 01/01/2007 Uncontrolled document when printed Current Version: 2.6,16/07/2008 (i) the risk level has been reduced to as low as reasonably practicable using the hierarchy of risk controls; (ii) the risk assessment has been reviewed and approved by the Supervisor and (iii) a Safe Working Procedure or Safe Work Method has been prepared. Act this month: Low Managed by local documented routine procedures which must include application of the hierarchy of controls. _______________________________________________________________________________________________________________ Page 8 of 8 UNSW Concise OHS Risk Rating Table Effective date: 01/01/2007 Uncontrolled document when printed Current Version: 2.6,16/07/2008