Attachment J-8 Amendment 1, RFP 1410-00002 Tables for SPKIR Instruments This attachment contains Microsoft Word versions of the tables found in Section L.7. Fill out Tables L-5 and L-6 with specifications of your proposed Downwelling Spectral Irradiance instruments and include them in the Technical Volume of your proposal. Section L.7.1.2.1 provides detailed instructions for filling out these tables. Table L-5 Downwelling Spectral Irradiance (SPKIR) Instrument Compliance Matrix With Instrument Specifications in Attachment J-3 Instrument Spec I.D. Parameter SPKI-001 Minimum value SPKI-002 Maximum value SPKI-003 Accuracy SPKI-004 Precision SPKI-005 SPKI-006 (threshold) Sampling frequency SPKI-007 (objective) SPKI-008 SPKI-009 Appendix Appendix Appendix Appendix Ver 0-03 Units Parameter Value by SPKIR Series A B Substantiation μmol photons m-2 s-1 μmol photons m-2 s-1 % μmol photons m-2 s-1 Hz Wavelength range nm to nm Number of bands Spectral bandwidth Operational Depth Range Survivable Depth Life of internal battery Internal Data Storage # of bands nm m m months N/A # of samples N/A Page 1 of 5 Attachment J-8 Amendment 1, RFP 1410-00002 Tables for SPKIR Instruments Table L-6 Downwelling Spectral Irradiance (SPKIR) Instrument Compliance Matrix With Common Specifications in Attachment J-1 Common Spec I.D. OPER-001 OPER-002 OPER-003 OPER-004 (objective) OPER-005 (objective) OPER-006 OPER-007 Parameter Units Salinity range Temperature range Biofouling mitigation measures provided? Biofouling mitigation provides specified accuracy for defined deployment intervals? Maintains calibration within specified accuracy for defined deployment intervals? Meets all performance requirements for defined deployment intervals without need for physical maintenance? Deployed, recovered, redeployed without performance impairment? PSS oC MECH-001 Instrument housing MECH-002 Instrument connector MECH-003 MECH-004 MECH-005 Electronic housings immersion depth ELEC-001 (objective) ELEC-002 (objective) ELEC-003 ELEC-004 Ver 0-03 Capable of operating in a +/- 50 VDC potential? Grounding with no connection to seawater? Battery Life Returns to defined state upon being depowered and repowered? Parameter Value by SPKIR Series A B Substantiation Yes/No Yes/No Yes/No Yes/No Yes/No Materials used Materials used N/A N/A m Yes/No (if no, voltage) Yes/No Months N/A Yes/No Page 2 of 5 Attachment J-8 Amendment 1, RFP 1410-00002 Tables for SPKIR Instruments Common Spec I.D. ELEC-005 (threshold) ELEC-006 (objective) DATA-001 INTF-001 INTF-002 Parameter Isolation from seawater Provides internal data storage? Powered by two wire floating voltages? Supply voltage Units Parameter Value by SPKIR Series A B Substantiation mega ohms Yes/No N/A N/A Yes/No N/A Volts DC N/A N/A INTF-003 Time Stamping List the supported capabilities INTF-004 (objective) Internal clock? Yes/No N/A Yes/No N/A bits/sec N/A INTF-005 INTF-006 INTF-007 (objective) Synchronize/set clock over the interface? Data rate if over serial interface User settable data rate over serial interface? Yes/No If yes, maximum serial rate N/A Yes/No INTF-008 (objective) INTF-009 INTF-010 INTF-011 INTF-012 (objective) INTF-013 INTF-014 (objective) INTF-015 COMP-001 Ver 0-03 Ethernet interface? ACKs command execution including succeed/fail? Communications interface(s) Remote control and access? Supports remote firmware installation? All data accessible remotely via communications interface? Supports polled operation? Supports asynchronous mode operation? Communicate via inductive modem? Standards compatibility If yes, list the autodiscovery mechanism (s) N/A Yes/No N/A List the interfaces N/A Yes/No N/A Yes/No N/A Yes/No N/A Yes/No N/A Yes/No N/A Yes/No N/A N/A N/A List the standards Page 3 of 5 Attachment J-8 Amendment 1, RFP 1410-00002 Tables for SPKIR Instruments Common Spec I.D. SHIP-001 SHIP-002 SHIP-003 IDEN-001 IDEN-002 QUAL-001 Parameter Units Containers meet ASTM D4169 Level 1? Stored without degradation between -20 and 50°C for 12 months? External cases labeled with safe handling precautions? Indelible vendor marking on external surface? Capable of OOI marking without damage? Materials used and treated reduce wear, corrosion, and deterioration to allow multiple deployments? Parameter Value by SPKIR Series A B Substantiation Yes/No Yes/No (if no, provide limitations) Yes/No N/A Yes/No N/A Yes/No N/A Yes/No Fill out Table L-7 with the models of your proposed Downwelling Spectral Irradiance instruments and include the table in the Technical Volume of your proposal. Section L.7.1.2.1 provides detailed instructions for filling out this table. Table L-7 Proposed Models for Downwelling Spectral Irradiance (SPKIR) Instruments SPKIR Series A B Ver 0-03 Contractor Instrument Model Number or Designation Page 4 of 5 Attachment J-8 Amendment 1, RFP 1410-00002 Tables for SPKIR Instruments Fill out Table L-8 and include it in the Past Performance Volume of your proposal. Section L.7.1.3 provides detailed instructions for filling out this table. Table L-8. Past Performance for Each Contract Effort name Company Performing the Effort Contract name Period of performance From DD/MM/YYYY to DD/MM/YYYY Contract value in $ Customer name and address Technical Point of contact information (name, phone number, e-mail) Contractual Point of contact information (name, phone number, e-mail) (extend as necessary) Ver 0-03 Page 5 of 5