Middle Week Report – Team 3 In the first day of work, all the teams received the information needed to start constructing the model in SWMM 5.0, like a plan of the studied area (a drawing in AutoCad), the existing rainfalls to calibrate and validate the model and a google image to verify details of the area. The studied area is called “La Riereta” and is located in Sant Boi de Llobregat, Catalunya, Spain. This catchment has a surface area of approximately 17 ha and it presents high indexes of impermeability. Its slope varies from high to medium values. Roof drainage discharges directly to the streets through downspouts. Additionally, a group of inlets distributed in the streets ensure the collection of the generated runoff after the occurrence of rainfall. The drainage system of “La Riereta” is a combined sewer network and it is mainly composed by circular cross-section pipes with different diameters and made by concrete. Team 3 started working with a brief analysis of the drawing in AutoCad, corresponding to the plan view of La Riereta. The team focused on the elements of the existent drainage network and the flow directions. The following steps were: - Definition of the principal catchment; Definition of the sub-catchments; Analysis of the corresponding inflow of each node; Collection of information of each sub-catchment, such as: area, slope, perviousness and roughness. Team 3 defined 17 sub-catchments with an approximate area of 1 ha. Figure 1 shows this division: Figure 1. Division of sub-catchments The studied catchment has at about 85% of impervious area. In the second day of work, Team 3 finished the data collection, using the information given in AutoCad, on the catchment plan, for conducts and manholes. Collected data were: - Conducts: identification of upstream and downstream nodes and their respective elevations; conduct length and conduct diameter. Manholes: identification of maximum depth and elevations. After that, the group started using SWMM, drawing the proposed network with all its components: subcatchments, conducts, manholes (junctions), outlet and pluviometer. Figure 2 shows the studied area in SWMM. Figure 2. Studied area in SWMM With the entire drainage network in SWMM, the following step consisted in inputing data related to its elements. The dynamic wave routing method was chosen. Three different rainfall events (Table 1), with their corresponding flows – measured at the catchment outfall – were assigned for each group. Each of these events is identified by the name of the saint of the day in which the registration started. Table 1. Rainfall events assigned for Team 3 Rainfall event – Team 3 Efrén Santa Cecilia Susana Figure 3. Rainfall event – Santa Cecilia Figure 4. Rainfall event – Efren Figure 5. Rainfall event – Susana The chosen rainfall events for calibration of the model were: Susana and Efrén. The resulting hydrographs are showed in Figures 4 and 5. Susana Rainfall Event 0.5 0.45 0.4 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 0 10 20 30 Measured flow(m3/s) 40 50 Calculated flow (m3/s) Figure 6. Calibration of the model with Susana rainfall event Efrén Rainfall Event 0.5 0.45 0.4 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 0 20 40 60 80 100 120 140 Measured flow (m3/s)Time [min]Calculated flow (m3/s) Figure 7. Calibration of the model with Efrén rainfall event Santa Cecilia rainfall event was used to validate the model. The corresponding hydrograph is showed on Figure 6. Santa Cecilia Rainfall Event 0.5 0.45 0.4 0.35 0.3 0.25 0.2 0.15 0.1 0.05 0 0 10 20 30 40 Measured flow (m3/s) 50 60 70 80 90 100 Calculated flow (m3/s) Figure 8. Validation of the model with Santa Cecilia rainfall event After the calibration and validation of the model, the adopted parameters for sub catchments, conducts and junctions were, respectively: Table 2. Parameters adopted for sub catchments Name S06 S12 S13 S01 S02 S03 S05 S07 S08 S09 S4A S4B S4C S10A S10B S11B S11A S14A Raingage Pluv1 Pluv1 Pluv1 Pluv1 Pluv1 Pluv1 Pluv1 Pluv1 Pluv1 Pluv1 Pluv1 Pluv1 Pluv1 Pluv1 Pluv1 Pluv1 Pluv1 Pluv1 Outlet N12 N9 N2 N13 N14 2 N12 N11 N11 N6 N10 N10 N10 N7 N15 N16 N9 N4 Total Area 0.5 0.66 2.06 0.77 0.44 1 0.66 0.55 0.9 0.69 0.6 0.09 0.5 0.87 0.57 1.1 0.95 0.2 Pcnt. Imperv 81.16 94.87 90.73 87.8 92.23 71.73 84.08 98.06 88.5 92.64 89.3 89.3 89.3 96.37 96.37 95.97 95.97 95.3 Width 500 660 2060 770 440 1000 660 550 900 690 600 90 500 870 570 1100 950 200 Pcnt. Slope 2.28 1.52 4.09 6.63 3.16 4.65 1.9 4.09 4.39 6.46 2.34 2.34 2.34 4.72 4.72 4.01 4.01 5.49 Curb N-Imperv N-Perv S-Imperv Length 0.65 0.15 0.04 0 0.65 0.15 0.04 0 0.65 0.15 0.04 0 0.65 0.15 0.04 0 0.65 0.15 0.04 0 0.65 0.15 0.04 0 0.65 0.15 0.04 0 0.65 0.15 0.04 0 0.65 0.15 0.04 0 0.65 0.15 0.04 0 0.65 0.15 0.04 0 0.65 0.15 0.04 0 0.65 0.15 0.04 0 0.65 0.15 0.04 0 0.65 0.15 0.04 0 0.65 0.15 0.04 0 0.65 0.15 0.04 0 0.65 0.15 0.04 0 S-Perv 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 PctZero RouteTo 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET OUTLET Table 3. Parameters adopted for conduits Name C2 C4 C6 C7 C9 C10 C11 C12 C13 C14 C5 C8 C15 C16 C12A Inlet Node N2 N4 N6 N7 N9 N10 N11 N12 N13 N14 N5 N8 N15 N16 2 Outlet Node N4 N5 N7 N8 N11 N11 N12 2 N14 1 N9 N9 N7 N9 N14 Length 70.86 50.56 80.59 59.12 123.33 61.14 108.06 36 120.34 45.52 64.88 10.73 105 145 50 Manning N 0.013 0.013 0.013 0.013 0.013 0.013 0.013 0.013 0.013 0.013 0.013 0.013 0.013 0.013 0.013 Inlet Offset 30.89 23.33 26.46 24.57 21.46 21.73 15.46 15.7 16.22 13.13 22.31 23.18 28.518 26.193 14 Outlet Offset 24.18 22.51 24.57 23.28 15.46 18.06 15.9 14.2 13.73 12.51 21.46 22.87 24.574 22.87 13.13 Init. Flow 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Max. Flow 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Link C2 C4 C6 C7 C9 C10 C11 C12 C13 C14 C5 C8 C15 C16 C12A Shape Geom1 CIRCULAR 0.5 CIRCULAR 0.4 CIRCULAR 0.4 CIRCULAR 0.4 CIRCULAR 1 CIRCULAR 0.3 CIRCULAR 1 CIRCULAR 1 CIRCULAR 0.6 CIRCULAR 1.2 CIRCULAR 0.6 CIRCULAR 0.5 CIRCULAR 0.5 CIRCULAR 0.6 CIRCULAR 1.2 Geom2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Geom3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Geom4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Barrels 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Table 4. Parameters adopted for junctions Name N2 N4 N6 N7 N9 N10 N11 N12 N13 N14 N5 N8 N15 N16 2 Invert Elev. 30.696 23.33 26.263 24.57 21.46 21.725 15.46 15.7 16.22 13.13 22.31 23.17 28.518 26.193 14 Max. Depth 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 Init. Surcharge Ponded Depth Depth Area 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0