#21 C2Sheets.doc APPLICATION HELP C2 Full Factory Calibration Configuration Form Required When you select the C2 option for a full factory calibration, it is necessary to submit a C2 Configuration Form. IMPORTANT!! The order will not be processed at the factory until the form is submitted. The required forms are provided in the pages that follow. Please submit the form that is appropriate for the electronics option selected. It is only necessary to provide the information that differs from the default values shown on the form. Blank spaces will automatically set the default value. Configuration Forms Below To print only the form you want, select: File > Print Select the “Pages” button and enter the pages indicated. 1. INTELLIGENT I/A SERIES PRESSURE TRANSMITTERS - FOXCOM “-D” VERSION Pages 2 – 4 2. INTELLIGENT I/A SERIES PRESSURE TRANSMITTERS HART “-T” VERSION Pages 5 - 7 3. I/A SERIES PRESSURE TRANSMITTERS 4 to 20 ma “-I” VERSION Pages 8 - 9 4. ANALOG OUTPUT I/A SERIES PRESSURE TRANSMITTERS “-A” VERSION Pages 10 - 11 5. ANALOG OUTPUT I/A SERIES PRESSURE TRANSMITTERS “-V” VERSION Pages 12 - 13 Page 1 of 8 INTELLIGENT I/A SERIES PRESSURE TRANSMITTERS - FOXCOM “-D” VERSION CONFIGURATION WORKSHEET FOR -C2 OPTION Customer: ________________________ P.O. No.: __________________Item No. (on P.O.): _____________ Your Office Order No.: _____________________________ Your Name: ____________________ Foxboro S.O. No.: ___________________________ Your Branch or Company: ___________________ Date: ___________ MAKE ONE SELECTION FOR EACH AND EVERY PARAMETER. IF ANY ITEMS ARE LEFT BLANK, THE FACTORY DEFAULT VALUES MAY BE USED FOR THE ENTIRE TRANSMITTER. REQUIRED: SEPARATE SHEET FOR EACH TAG NUMBER, UNLESS ALL CONFIGURATION DATA IS IDENTICAL. Category/Parameter Information Factory Default Optional Configuration Requested Descriptors: Tag Number 12 Characters, max. Tag Number _________________________ Tag Name 14 Characters, max. Owner Tag Name _________________________ Location 14 Characters, max. Instr Location _________________________ Device Name 6 Characters, max. DevNam _________________________ Calibrated Range LRV may be < or > URV. If Sq. Rt., LRV must = 0. See List B for Default Calibrated Range by model. _____ to _____ _____ LRV URV Units (See List A for available units) Meas. #1 Mode 4-20 mA or Digital 4-20 mA □ 4-20 mA Measurement #1 Characteristic If LRV>URV, select Linear. Square root applicable to IDP10. Linear □ Linear □ Sq. Rt. w/Cutoff □ Sq. Rt. w/Active Low End Measurement #1 EGU's If Sq.Rt., use % or Custom. Std. Pressure Units from Calibrated Range, above. □ Std. Press. Units from Calib. Range, above. (Requires Meas.#1 Linear) Input: Output: If "Custom", specify LRV, URV, & Units. For example, 0 to 100 GPM. □ Digital □ 0 to 100 % □ Custom Units, Specify: Specified EGU's will also be used for optional LCD. LIST A (Standard Pressure Units): -psig -ftH2O -bar -psia -inH2O -mbar -inHg -atm -MPa -Pa -kg/cm2 -g/cm2 -dy/cm2 -cmHg -mmHg _____ to LRV _____ _____ URV Units (6 Characters, Maximum) -torr -cmH2O -mmH2O -kPa 1/30/97 Rev. Page 2 of 8 WORKSHEET FOR -C2 OPTION ON -D INTELLIGENT VERSIONS (CONT.) PAGE 2 OF 3 Data for Tag Number _______________, continued: Category/Parameter Factory Default Optional Configuration Requested Linear □ Off □ Linear □ Sq. Rt. w/Cutoff □ Sq. Rt. w/Active Low End 0 to 100 % If "Custom", specify LRV, □ Std. Press. Units from List A Specify Units:_____Note (b) (Meas. #2 must be Linear) URV, & Units. For example, 0 to 100 GPM. □ 0 to 100 % □ Custom Units, Specify: Choices/Information Output (Continued) Measurement #2 Status and Characteristic Square root applicable to IDP10. Note (a) Measurement #2 EGU's If Sq.Rt., use % or Custom. Specified EGU's will also be used for optional LCD Indicator. Note (c). _____ to LRV _____ _____ URV Units (6 Characters, Maximum) Failsafe Direction: (4-20 mA, only) High or Low mA on certain faults High □ High □ Low Temp. Failure Strategy Fail or Continue with Default Temperature Continue □ Fail □ Continue External Zero Adjust Security For optional External Zero adjustment Enabled □ Enabled □ Disabled Swap Meas. #1 & #2 Interchange configured outputs No □ Yes □ No Damping: None, 0.25, 0.50, 1, 2, 4, 8, 16, or 32 seconds None Specify: ________________ WHERE TO SEND THIS FORM: Until this form is included in SiebeStore for electronic transmission with the order, FAX or mail Pages 1 & 2 to your Distribution Coordinator whenever the -C2 Option is specified on an order. 1/30/97 Rev. Page 3 of 8 WORKSHEET FOR -C2 OPTION ON -D INTELLIGENT VERSIONS (CONT.) PAGE 3 OF 3 NOTES: (a) If Measurement #1 is configured "Square Root", which precludes use of pressure units, consider configuring Measurement #2 "Linear" to provide a means of reading pressure units. Also, if Measurement #1 is in "Square Root" mode, the pressure units for reranging from the optional LCD indicator default to "Transmitter Default Units" (such as inH2O on a "B" Span IDP10) unless Measurement #2 is "Linear", in which case they default to the standard pressure units specified for Measurement #2. This provides a convenient way to rerange in preferred local pressure units, such as mbar or mmH2O. (b) Units selected for Measurement #2 may be different from units selected for Measurement #1. (c) The optional LCD Indicator normally displays Measurement #1. It will display Measurement #2 if the "Enter" pushbutton is pressed once. It defaults to Measurement #1 upon removal of power and therefore can only be selected after transmitter is installed and powered. (d) Handheld Terminal (HHT) and optional LCD w/Pushbuttons can be used to configure most selections. A few require the PC10 or I/A Series System Configurators. (e) A Forward/Reverse selection can be used to achieve the requested calibration direction, based on LRV & URV. LIST B (Default Calibrated Ranges) The following calibrated ranges & units will be used if the Calibrated Range is left blank or is marked "Uncalibrated". Model Span Code Default Calibrated Range IDP10 B & C IGP20 D E 0 to 200 inH2O 0 to 840 inH2O 0 to 300 psi 0 to 3000 psi IGP10 C D E 0 to 30 psi 0 to 300 psi 0 to 3000 psi IAP10 C D E 0 to 30 psia 0 to 300 psia 0 to 3000 psia 1/30/97 Rev. Page 4 of 8 ANALOG OUTPUT I/A SERIES PRESSURE TRANSMITTERS “-A” VERSION CONFIGURATION WORKSHEET FOR -C2 OPTION Customer: ________________________ P.O. No.: __________________Item No. (on P.O.): _____________ Your Office Order No.: _____________________________ Your Name: ____________________ PAGE 1 OF 2 Foxboro S.O. No.: ___________________________ Your Branch or Company: ___________________ Date: _____________ MAKE ONE SELECTION FOR EACH AND EVERY PARAMETER. IF ANY ITEMS ARE LEFT BLANK, THE FACTORY DEFAULT VALUES MAY BE USED FOR THE ENTIRE TRANSMITTER. REQUIRED: SEPARATE SHEET FOR EACH TAG NUMBER, UNLESS ALL CONFIGURATION DATA IS IDENTICAL. Factory Default See List B for Default Calibrated Range by model. Optional Configuration Requested _____ to _____ _____ LRV URV Units (See List A for available units) Category/Parameter Calibrated Range Information LRV may be < or > URV. If Sq. Rt., LRV must = 0. Characteristic If LRV>URV, select Linear. Square root applicable to IDP10. Linear □ Linear □ Sq. Rt. w/Cutoff □ Sq. Rt. w/Active Low End Failsafe Direction: High □ High □ Low External Zero Adjust Security Damping: High or Low mA on certain faults For optional External Zero adjustment None, 2, 4, or 8 seconds Enabled □ Enabled □ Disabled None □ None □ 2 sec. □ 4 sec. □ 8 sec. Temp. Failure Strategy Fail or Continue with Default Temperature Continue □ Fail □ Continue LCD Indicator: (LINEAR MODE) If in Linear Mode there are no configuration choices; the display automatically shows the measured pressure in the units previously selected for the Calibrated Range. LCD Indicator: (SQ. RT. MODE) Label (Engr. Units PERCENT for Display – typically the Flow Rate Units). Select up to seven alphanumeric characters. Alpha’s are Upper Case Only. Spaces are allowed. Available symbols include: ], *, +, -, /, \, <, >, and [ LCD Indicator: (SQ. RT. MODE) (Continued) Page 5 of 8 Display Upper Range Value, (typically the Maximum Flow Rate). Specify up to four digits, a + or -, and location of decimal point. Write alphanumerics here Write numbers here 100 Mark * + or - Mark Decimal Point here. in one of these 4 places. * (dec.pt. at far rt. position not displayed on LCD) 6/18/98 Rev. WORKSHEET FOR -C2 OPTION ON ANALOG OUTPUT “-A” VERSION (CONT.) PAGE 2 OF 2 LIST A – Available Standard Pressure Units (displayed in UPPER CASE only): -psi -inHg -bar -kg/cm2 -MPa -inH2O -mmH2O -mbar -Pa -torr -ftH2O -mmHg -g/cm2 -kPa -atm LIST B (Default Calibrated Ranges) The following calibrated ranges & units will be used if the Calibrated Range is left blank or is marked "Uncalibrated". Model IDP10 & IGP20 IGP10 & IAP10 Span Code A B C D E Default Calibrated Range 0 to 30 inH2O 0 to 200 inH2O 0 to 840 inH2O 0 to 300 psi 0 to 3000 psi C D E 0 to 30 psi 0 to 300 psi 0 to 3000 psi Reranging: The -A version supports reranging without pressure and can be reranged in the field. Reranging must be done in Linear Mode. If there is a custom flow rate display (Square Root Mode only), it will have to be reconfigured following a reranging. LCD Indicator (Standard on –A Electronics Modules): There are two lines for display of up to four numeric characters for the measurement on the top line (with plus or minus & selectable decimal point position) and up to seven alphanumeric characters on the bottom line, referred to as the Label. In Linear Mode the display shows the measured pressure in the units selected for the calibrated range and cannot be changed. In Square Root Mode the display defaults to 0 to 100 PERCENT. However, the display can be configured to show the flow rate and flow rate units. When placed in Square Root Mode, the transmitter retains the calibrated range defined by the pressure range LRV and URV, previously entered and saved. When flow rate is to be displayed, the maximum flow rate corresponding to the 20 mA output signal must be entered. If the maximum flow rate exceeds four digits, use a multiplier such as X10. For example, if the flow rate URV is 40000 SCFH, you could specify 4000 for the display URV and X10SCFH for the Label on the bottom line. WHERE TO SEND THIS FORM Until this form is included in SiebeStore for electronic transmission with the order, FAX or mail Page 1 to your Distribution Coordinator whenever the -C2 Option is specified on an order. 6/18/98 Rev. Page 6 of 8 ANALOG OUTPUT I/A SERIES PRESSURE TRANSMITTERS “-V” VERSION CONFIGURATION WORKSHEET FOR -C2 OPTION Customer: ________________________ P.O. No.: __________________Item No. (on P.O.): _____________ Your Office Order No.: _____________________________ Your Name: ____________________ PAGE 1 OF 2 Foxboro S.O. No.: ___________________________ Your Branch or Company: ___________________ Date: _____________ MAKE ONE SELECTION FOR EACH AND EVERY PARAMETER. IF ANY ITEMS ARE LEFT BLANK, THE FACTORY DEFAULT VALUES MAY BE USED FOR THE ENTIRE TRANSMITTER. REQUIRED: SEPARATE SHEET FOR EACH TAG NUMBER, UNLESS ALL CONFIGURATION DATA IS IDENTICAL. Factory Default See List B for Default Calibrated Range by model. Optional Configuration Requested _____ to _____ _____ LRV URV Units (See List A for available units) If LRV>URV, select Linear. Square root applicable to IDP10. Linear □ Linear □ Sq. Rt. w/Cutoff □ Sq. Rt. w/Active Low End High □ High □ Low External Zero Adjust Security Damping: High or Low V on certain faults For optional External Zero adjustment None, 2, 4, or 8 seconds Enabled □ Enabled □ Disabled None □ None □ 2 sec. □ 4 sec. □ 8 sec. Temp. Failure Strategy Fail or Continue with Default Temperature Continue □ Fail □ Continue LCD Indicator: (LINEAR MODE) If in Linear Mode there are no configuration choices; the display automatically shows the measured pressure in the units previously selected for the Calibrated Range. LCD Indicator: (SQ. RT. MODE) Label (Engr. Units PERCENT for Display – typically the Flow Rate Units). Select up to seven alphanumeric characters. Alpha’s are Upper Case Only. Spaces are allowed. Available symbols include: ], *, +, -, /, \, <, >, and [ Category/Parameter Calibrated Range Information LRV may be < or > URV. If Sq. Rt., LRV must = 0. Characteristic Failsafe Direction: LCD Indicator: (SQ. RT. MODE) (Continued) Display Upper Range Value, (typically the Maximum Flow Rate). Specify up to four digits, a + or -, and location of decimal point. Write alphanumerics here Write numbers here 100 Mark * + or - Mark Decimal Point here. in one of these 4 places. * (dec.pt. at far rt. position not displayed on LCD) 6/18/98 Rev. Page 7 of 8 WORKSHEET FOR -C2 OPTION ON ANALOG OUTPUT “-V” VERSION (CONT.) PAGE 2 OF 2 LIST A – Available Standard Pressure Units (displayed in UPPER CASE only): -psi -inHg -bar -kg/cm2 -MPa -inH2O -mmH2O -mbar -Pa -torr -ftH2O -mmHg -g/cm2 -kPa -atm LIST B (Default Calibrated Ranges) The following calibrated ranges & units will be used if the Calibrated Range is left blank or is marked "Uncalibrated". Model IDP10 & IGP20 IGP10 & IAP10 Span Code A B C D E Default Calibrated Range 0 to 30 inH2O 0 to 200 inH2O 0 to 840 inH2O 0 to 300 psi 0 to 3000 psi C D E 0 to 30 psi 0 to 300 psi 0 to 3000 psi Reranging: The -V version supports reranging without pressure and can be reranged in the field. Reranging must be done in Linear Mode. If there is a custom flow rate display (Square Root Mode only), it will have to be reconfigured following a reranging. LCD Indicator There are two lines for display of up to four numeric characters for the measurement on the top line (with plus or minus & selectable decimal point position) and up to seven alphanumeric characters on the bottom line, referred to as the Label. In Linear Mode the display shows the measured pressure in the units selected for the calibrated range and cannot be changed. In Square Root Mode the display defaults to 0 to 100 PERCENT. However, the display can be configured to show the flow rate and flow rate units. When placed in Square Root Mode, the transmitter retains the calibrated range defined by the pressure range LRV and URV, previously entered and saved. When flow rate is to be displayed, the maximum flow rate corresponding to the 5 V output signal must be entered. If the maximum flow rate exceeds four digits, use a multiplier such as X10. For example, if the flow rate URV is 40000 SCFH, you could specify 4000 for the display URV and X10SCFH for the Label on the bottom line. WHERE TO SEND THIS FORM Until this form is included in SiebeStore for electronic transmission with the order, FAX or mail Page 1 to your Distribution Coordinator whenever the -C2 Option is specified on an order. 6/22/99 Rev. Page 8 of 8