Implementation regulation of energy efficiency label for household refrigerators 1. General Provisions 1.1 The Regulations are developed according to Rules on the administration of Energy Efficiency Labeling ( hereinafter referred to as the Rules ) ,i.e. the No.17 Order issued by National Development and Reform Commission ( NDRC ) and General Administration of Quality Supervision , Inspection and Quarantine of the People ' s Republic of China ( AQSIQ ) . 1.2 The Regulations are applicable to application , registration and publication of energy efficiency label ( hereinafter referred to as the Label ) for motor driven compressed refrigerators with the capacity of 500L and below . 2 . Form and Specification 2.1 The label is a colorful one with blue -and –white background ,162mm long and 98mm wide . 2.2 The name of label is China Energy Label . The following information is provided on the label; ·Name of manufacturer ·Product model ·Level of energy efficiency ·Power consumption ( kwh / 24 hrs ) . . ·Cuage of each compartment ( L ) , such as those for chilling , freezing , fresh food storage , etc . ·Serial number of the relevant national standard for energy efficiency 2.3 Refer to Annex 3 for details. 3. Definition of Label Information 3.1 Manufacturer indicates the owner of product brand . 3.2 Model specification shall be developed according to the requirements of currently valid edition of GB / T 8059 . 1-8059 . 4 . A manufacture serial number could be provided at the same time , and shall be consistent with that on the nameplate of the product . 3.3 Level of energy efficiency shall be defined according to the requirements of currently valid edition of GB 12021 · 2 and the test report of energy efficiency of household refrigerators ( hereinafter referred to as the test report ) . Please see Annex 4-2 for the template of the test report . 3.4 Power consumption shall be defined according to the requirements of currently valid edition of GB / T 8059 . 1 -8059 . 4 and the test report and shall not exceed the upper limit of energy efficiengy level . 3.5 Cubage of functional compartments shall be defined according to the requirements of currently valid edition of GB / T 8059 . 1-8059 . 4 and the test report . 3.6 The basis for reference shall be currently valid edition of GB 12021.2. 4 . Printing and Sticking of the Label 4.1 The manufacturer or importer shall be responsible for printing the label and the printing quality . 4.2 The label shall be printed in copperplate paper with weight of 100 grams or above . 4.3 The label shall be pasted with non-dry glue . No stain shall be left on the surface after its removal . 4.4 The label shall be presented for each refrigerator in leaving factory or imported . 4.5 The label shall be placed on top right corner of panel of refrigerator frontispiece . 4.6 The label shall be consistent with requirements of article 2 of the Regulations . No change shall be made to the logo , literature , specification and color. 4.7 For uses in manual , package or promotion , the label can be magnified or minified proportionally , and printed in black and white while readily legible . 5 . Registration of the Label 5.1 Manufacturers or importers shall have each set of their products registered based on product model . Products with different models but same cooling system and same power consumption are exempted from test report in registration . 5.2 Manufacturers and importers shall complete and submit the Registration Form of Energy Efficiency Label for Household Refrigerators within in 30 days after applying the label by letter , telegraph , telex , fax , e-mail or through relevant website . ( Refer to Annex 4-1 ) Manufacturers or importers shall submit the other registration documents at the same time according to the Rules . The Form and documents shall be complete and authentic . 5.3 The authorized organization shall finish checking and registering within 10 workdays after receiving the registration materials . ( excluding the days for anufactures or importers preparing additional materials required ) The authorized organization shall register , archive and number the registration materials , and inform the relevant manufacturer or importer by email or in written form if the application meets the requirements of article 5.2 of the Regulations . The authorized organization shall inform the relevant manufacturer or importer to submit additional materials or change label in use if the application fails to meet the requirements of article 5. . 5. .4 Manufacturers or importers shall submit a report about the label application in the past year to the authorized organization before 15th March every year . The report shall include cases for all registered models , penalties and their label application . 5.5 Materials in foreign language shall be accompanied by a Chinese version , and the latter takes precedence . 6. Label Publication 6.1 The authorized organization shall make publication for the labeled product on the official website within 10 days after its registration is made and updated the information quarterly in a relevant media . 6.2 Registration information shall be published according to registration serial number . 6.3 The authorized organization shall establish a database of product energy efficiency , provide information service on product energy efficiency to manufacturers and consumers and make publication in a timely manner on label checking and surveillance . 6.4 The authorized organization shall make its hotline and website available to the public and respond to complaint from manufacturers and consumers . Annex 1 Registration Form for Household Refrigerator Energy Label 1 . Statement We promise : The information carried by the Energy label in use is consistent with that in registration ; To apply for new registration from authorized organization when the energy label 15 to be changed of this product model ; To guarantee this product model will meet the requirements of energy label in its life span . 2 . Information of energy label Manufacturer : Product Model : Item Power Consumption ( kW · h / 24h ) Cubage of chilling compartment ( L ) Cubage of freezing compartment ( L ) Cubage of other compartments ( L ) Level of energy efficiency Value Note 3.Starting date of usage The label is put into use for* * *(model) on * * * (dd/mm/yy) 4.Other information Key components Model component Technical parameters Refrigerati on (W) Full Power input (W) COP manufacturer Compressor Refrigerant Foam material Thickness heat insulation wall wall thickness of chilling compartment : wall thickness of freezing compartment : Description of sample Performance of power supply 口 AC 口 DC Type of climate 口 SN 口N Refrigerating compartment 口 口(frost free) Freezing compartment Other compartments 口 口(frost free) Number of doors Type of condenser Type of temperature controller Position of temperature controller Position of lamps 口 口 口 口 口 口 口 口 口 口 口 ST name 口T 口(frost free ) 口(frost free ) 口(frost free ) 口 drawer style outside hang 口 flat machine 口 digital refrigerating ompartment freezing compartment refrigerating compartment freezing compartment Exterior dimensions reglstrant : ( seal ) : ( date ) of Annex 2 Test Report of Energy Efficiency for Household Refrigerator Report No . : Testing organization ( Seal ) : Tester: date: Verifier: date: Approval : : Product : Model : Manufacturer / Brand : Client : Site of production : date: : Supplement 1 . The seal for test report or the seal of testing organization is necessary for validity of the report ; 2.The seal for test report or the seal of testing organization is necessary validity of a duplication of the report; no duplication shall be made . Duplication of any part of the test report shall no be made without a written permission from the client. 3 . The test report is invalid without stamp and signature of the tester , verifier and approver ; 4 . The test report is invalid with altering ; 5 . Any testing disagreements shall be claimed within 15 days to the organization ; 6 . The testing organization is only responsible for testing results of samples . Testing Report (number): page * of * page Model Number of sample Brand Serial number of sample Number of sample Site of sampling Cardinal number of sample Date of sampling Grade of sample Arrival date of sample Original serial number or production date Date of testing GB 12021.2the maximum allowable value of energy consumption and energy Testing criteria efficiency grade for household refrigerators GB/T 8059.X Subject to be tested Cubage and power consumption of each compartment Effective cubage and power consumption of *** refrigerator produced by *** have been tested and items test meet the pertinent requirement set forth in GB 12021.2. The energy efficiency rate is X. (End) Conclusion Seal for test report yyyy/ mm/ dd S.N. : page Page * of * Power supply………………………………: 口 triphase 口 diphase Climate type……………………………: 口 SN Chilling compartment………………: 口 Freezing compartment…………………:口 口N 口T 口 frost free 口 frost free Other compartment……………………………………: 口 temperature: 口 ST 口 frost free rated ℃ Number of doors……………………………………:口 口 drawer type Refrigerant…………………………………: 口 out-hanging 口 flat Type of temperature controller……………………: 口 mechanic 口 digital Position of temperature controller……………………………: 口 Chilling compartment 口 Freezing compartment Sample description Position of lamps……………………………: 口 Chilling compartment 口 Freezing compartment Other information Picture of inside ,outside and compressor of the sample and the nameplate Testing Result (Test of compressor: S.N. Subject tested Technical requirements ) Test result Type of compartment The testing method set out by 1 Effective Cubage GB/T8059 .1-8059. 4 . The result shall not be less than 97 % of total rated effective cubage(Unit:L) Value Tested according to the method set out by GB 12021 . 2 . The result shall 2 Power Consumption not be more than 115 % of the nominal value of power consumption and shall be less than the power consumption limit ( Unit : kW· h / 24h ) Level of Energy Efficiency Total adjusted volume (L) Power consumption limit Index of energy efficiency (kW·h/24h) (%) Level of energy efficiency List of compressors Model Volume of refrigeration (W) Energy efficiency rate (W/W) Manufacturer