Proton acceleration using circular laser polarization, foam and half

advertisement
Optimization of flat-cone target for enhanced laser-acceleration of protons
P.Antici1,2,a, S. Gaillard3, L. Gremillet4, M. Amin5, M. Nakatsutsumi2, L. Romagnani6, M. Tampo7,b, T.
Toncian5, R. Kodama7, P. Audebert2, H. Pépin8, O. Willi5, M. Borghesi6, T. Cowan3,9, J. Fuchs2,c
1
Università la Sapienza, Dip. di energetica, Via Scarpa 14, 00161 Roma, Italy
Laboratoire pour l’Utilisation des Lasers Intenses, UMR 7605 CNRS-CEA-École PolytechniqueUniv. Paris VI, 91128 Palaiseau, France
2
3
Physics Department, MS-220, University of Nevada, Reno, Nevada 89557, USA
4
CEA, DAM, DIF, 91297 Arpajon, France
5
Institut für Laser und Plasma Physik, Heinrich-Heine-Universität Düsseldorf, Universitätstrasse 1,
40225 Düsseldorf, Germany
School of Mathematics and Physics, The Queen’s University, Belfast, United Kingdom
6
7
Graduate school of Engineering, Osaka University, Suita, Osaka 565-0871, Japan
8
INRS-EMT, Varennes, Québec, Canada
9
Forschsungszentrum Dresden Rossendorf, Postfach 510119, 01314 Dresden, Germany
a) present address:
ILE - Ecole Polytechnique - CNRS –ENSTA – Iogs - UP Sud, Batterie de l’Yvette, 91761 Palaiseau,
France
Istituto Nazionale di Fisica Nucleare, Via E. Fermi 40; 00044 Frascati, Italy
b) present address:
Kansai Photon Science Institute, Japan Atomic Energy Agency (JAEA), Kyoto 619-0215, Japan
c) julien.fuchs@polytechnique.edu
Abstract: We have analyzed the acceleration of laser-generated protons, produced at the rear surface
of flat-cone targets irradiated by an ultra-intense (I~ 5 1019 W/cm²) short (400 fs) laser pulse. We used
different target sizes and shapes in order to find the optimum target layout. We find that for targets
with a too narrow cone structure, the production of the hot electrons, driving the proton acceleration, is
located prior to the accelerating rear surface of the target, resulting in a reduced maximum proton
energy.
Laser-driven ion beams [1], obtained when irradiating thin solid foils with intense (> 1018 W/cm²)
short laser pulses, have unique properties in terms of ion number, ion energy, short duration and
laminarity. Recently, much effort has been put in order to shape these beams and different techniques
have been developed to reduce the energy spread [2,3], the divergence [3,4] and to enhance the
maximum proton energy so that these beams might be more suitable for different applications such as
Inertial Confinement Fusion, radiography, astrophysics or medicine [1]. Currently, for the available
laser intensities, the dominant mechanism that leads to acceleration of high-energy protons in the laser
forward direction occurs at the non-irradiated (rear) target surface [1]. It is driven by relativistic
electrons, accelerated by the laser pulse at the laser-irradiated (front) surface, that propagate through
the target and form on the rear surface an electron sheath accelerating the ions. The protons originate
from contaminants that are located at the target rear surface. This acceleration mechanism is called
Target Normal Sheath Acceleration (TNSA). In order to enhance this acceleration mechanism,
particular attention has been paid to the target fabrication, leading to an increase of the electron
generation and transport. Cone target had been identified as a good mean to concentrate hot electrons
[5] and thus potentially to generate higher proton energies. More complex targets, using this cone
structure, have been manufactured, e.g. attaching or manufacturing a small flat foil at the end of the
cone (see Figure 1), called flat-tip cones [6]. The interest for these target configurations is two-fold:
(i) a potentially higher laser coupling into hot electrons [7] and (ii) a potentially geometrically
confined population of hot electrons within the small flat target positioned at the cone tip, both leading
to enhanced electric field within the electron sheath driving the ion acceleration [1]. These targets have
shown to produce currently, using the Trident LANL laser facility, the highest available laser
generated proton energies of about 67 MeV [8]. In this paper we show results, obtained at the LULI
100 TW laser, using such targets with different geometries, in order to find an optimized target
configuration.
The experiments were performed using the 100 TW short pulse laser at the Laboratoire pour
l’Utilisation des Lasers Intenses (LULI). Laser pulses of ~20-30 J at the fundamental frequency of
0=1.056 µm (compressed down to 350 fs) were focused to a best focal spot of FWHM 6 µm yielding
a maximum intensity of Imax~5 1019 W/cm2. As shown in Figure 1, all targets were irradiated at normal
incidence and the laser best focus point was positioned at the end point of the cone. Pointing of the
laser focal spot was done prior to every shot with a <10 µm precision. As assessed on full-energy
shots, the pointing stability between alignment and shot is~15 µm. The cone tip was aligned to the
same location as the laser focal spot with a precision of ~5 µm. We mainly used as diagnostic of the
accelerated proton beam radiochromic film (RCF) densitometry media [9] that allow a coarse
resolution of the accelerated proton beam at the target rear surface. RCF were put in a stack. Due to
the localized stopping power of ions into the RCFs, the spatial distribution of the protons in a given
RCF layer gives the angular emission pattern at a specific interval of proton energy.
100 TW
Laser
Amplifier
Φ=16 mm
Amplifier
Φ=25 mm
Amplifier
Φ=45 mm
Diskamplifier
Densities (OD=0, 0.3, 0.6)
parabola
Vacuum
Compressor
E=30 J
τ=0.3 ps
Focal spot~6 µm
Laser
Φ
(a)
Target
RCF
Chamber
(b)
Figure 1: a) Photograph and geometry of the flat-tip cone targets; b) Setup of the experiment.
Figure 2 shows the result of three different shots performed at normal incidence using three different
target geometry as indicated. The targets were made out of Au and the thickness of the flat section at
the end of the cone is 10 µm. We can see that for larger cone of 90 µm attached to a foil of 300 µm we
obtained the highest proton energies, around 10.5 MeV, as indicated by the 8 layers of RCF that
shown proton signal. The maximum proton energy thus obtained is quite lower compared to the one
produced by irradiating a flat foil of similar thickness directly with the laser without the addition of the
cone (~18 MeV). When reducing the diameter of the cone to 50 µm and the foil attached to the cone to
210 µm, the maximum proton energy reduces further to 9 MeV. A significant reduction of the proton
energy, and a significant disruption of the proton beam pattern, is however obtained when reducing the
cone diameter to 20 µm and the attached foil to 50 µm. In that configuration, only 1 MeV protons
could be obtained. As obvious from Figure 2, while for the shots using cone diameters of 90 or 50 µm
the RCF show a uniform proton beam, for the case of 20 µm the proton beam shows high non
uniformities.
In order to get a better insight in the results and to investigate laser-cone interaction physics, we look
at the result of simulations performed using the PIC code CALDER and using similar laser parameters
as in the experiment [10]. We consider two simulation cases, using the same cone as in Figure 2c), and
corresponding to two scale lengths of preplasma (the preplasma being in exponentially increasing
density ramp of variable scale-length p) at the surface of the flat foil that would be generated by the
energy preleading the main laser pulse. The cone have 30° full angle, 200 aperture, 4.80 thick walls,
attached to a 9.50 thick foil. The material is made of mobile Al5+ ions, with maximum electron
density ne = 100nc and initial temperature Te = 1 keV. The laser pulse has the following characteristics:
Imax = 1019 Wcm-2, 280 fs FWHM (sin2) temporal profile and 160 FWHM (gaussian) transverse
profile. The first simulation case corresponds to a small preplasma with p =1 µm. The second
simulation corresponds to a more realistic scale-length p = 7 m adapted to the ASE of the LULI
laser facility. Figure 3a) shows the hot electron kinetic energy density of the simulation of the small
preplasma. We can see that the electron kinetic energy is mostly located at the foil attached to the
cone, i.e. the foil at the rear surface of which the acceleration process of ions takes place, generating
therefore efficient proton acceleration at the target surface. Figure 3b) shows the case of the longer
preplasma. As one can see, the electron kinetic energy is mostly concentrated upstream within the
cone, and not at the foil surface as in Figure 3a). As electron heating occurs in a wide region of
subcritical plasma inside the cone, the absorption surface being moved further outward, the angularly
spread electrons get more diluted near the target rear side. The rear-side energy density and fast
electron density are observed to drop by factors ~ 0.5 and ~ 0.3, respectively, compared to the small
preplasma case. Moreover, fragmentation of the forward electron flux arises at larger scale than in the
short-gradient case. All this results in a lower accelerating electric field within the electron sheath at
the flat target surface. This justifies the worse proton beam obtained in the RCFs of Figure 2c): the
preplasma does not allow an efficient production of hot electrons within the confined cone geometry.
Other experiments [10] performed at the LULI laser facility using frequency-doubled laser pulses void
of ASE and therefore of preplasma formation within the cones have further confirmed these results.
Emax=10.5 MeV
300 µm
(a)
 90 µm
210 µm
Emax=9 MeV
 50 µm
Emax=1 MeV
30 µm
(b)
(c)
 20 µm
Figure 2: Three shots using three different target geometries: a) with a cone of neck diameter 90
µm attached to a flat target of 300 µm diameter, b) with a cone of neck diameter of 50 µm and
flat target of 210 µm diameter and c) with a cone of neck diameter 20 µm and flat foil of 30 µm
diameter. All shots were using a laser of intensity I= 5 1019 W/cm² at normal incidence.
Since this cone geometry could not be exploited efficiently using the laser at the fundamental
frequency, we explored to possibility of performing shots in an “inverse-cone” configuration. In this
case, the laser irradiates directly the foil that is attached to a cone (having with different diameter size),
see Figure 4). The idea here is to see if we could still take advantage of the limited target surface,
compared to a large flat target, in order to confine the electrons. The material of the target was still Au
and had a thickness of 10 µm. This time, as shown in Figure 4a), when using a large diameter cone of
90 µm at its smaller end, we obtain as maximum energy 17.3. MeV. This energy corresponds to that
we obtain shooting directly on a large (mm size) flat foil of the same thickness. The cone structure
therefore has no influence on the proton acceleration mechanism and the limited mass of the overall
target does not also seem to play a role, probably because the cone is long (200 µm), longer than the
sheath extension as measured on a large flat target [11]. When choosing a smaller cone diameter, e.g.
40 µm at its smaller end, we obtain much lower proton energies (5 MeV) and a less smoother proton
beam. One possibility to explain this would be that in such a narrow target the electric fields generated
by the hot electrons on the inner walls of the cone target deflected at large angle the protons, similarly
as in [3].
In summary, testing the possibility to use flat-tip cone targets showed the critical importance of
reducing the level of energy preleading the main pulse in order to avoid producing the hot electrons
upstream within the cone and not at its tip. Reverse target configurations were also tested but did not
yield enhanced proton acceleration, probably due to too strong deflecting fields produced within the
conical structure when using too narrow cones.
(a)
(b)
Figure 3: Two different simulations [10] using the code CALDER and showing the laser
interaction with the cone target under two different conditions: a) with a large cone geometry b)
with a narrow cone geometry.
 200 µm
 90 µm
Proton beam
200 µm
 40 µm
(a)
 200 µm
Proton beam
300 µm
Emax=17 MeV
Similar to the
same thickness
flat foil shot in
the same laser
conditions
Emax=5.5 MeV
3
2
6
9
12
15
5
8
11
14
1
4
7
10
13
1
2
3
4
5
(b)
Figure 4: Two different experimental conditions using the “inverse-cone-configuration”, i.e. the
laser was hitting first on a flat foil attached to a cone with different diameters: a) an initial cone
diameter of 90 µm expanding to 200 µm and b) an initial cone diameter of 40 µm expanding to
200 µm.
We acknowledge the expert support of the LULI laser team. This work was supported by grant
E1127 from Région Ile-de-France and UNR grant DE-FC08-01NV14050 and the projects ELI and
SPARX-FEL.
1 M. Borghesi et al., Fusion Sci. Technol. 49, 412 (2006); J. Fuchs et al., C. R. Physique 10, 176
(2009).
2 B. M. Hegelich et al., Nature (London) 439, 441 (2006); H. Schwoerer et al., Nature (London) 439,
445 (2006).
3 T. Toncian et al., Science 312, 410 (2006).
4 M. Schollmeier et al,. Phys. Rev. Lett. 101, 055004 (2008).
5 R. Kodama et al., Nature (London) 432, 1005, (2004); Z. Chen et al., Phys. Rev. E 71. 036403
(2005); Z. Chen et al., Phys. Rev. Lett. 96, 084802 (2006).
6 K. Flippo et al., Phys. Plasmas 15, 056709 (2008).
7 Y. Sentoku et al., Phys. Plasmas 11, 3083(2004).
8
http://www.aps.org/meetings/unit/dpp/vpr2009/loader.cfm?csModule=security/getfile&pageid=19180
5
9 N. V. Klassen, et al., Med.Phys., 24, 1924 (1997).
10 S. Baton et al., Phys. Plasmas 15, 042706 (2008).
11 L. Romagnani et al, Phys Rev. Lett 95, 195001 (2005); P. Antici et al., Phys. Rev. Lett. 101,
105004 (2008).
Download