UCSF Lab Standard Operating Procedure Chemical Process, Name or Hazard Class: 1,2-Diethylhydrazine Please fill out the form completely. Insure all users have access to this SOP. Refer to instructions for assistance. Enter text. Department: Date SOP was written: Enter date. This lab specific SOP has been reviewed and approved by: Principal Investigator Name: Enter text. Principal Investigator Signature Lab Manager/Supervisor: Type of SOP: ☐ Process Enter text. ☒Hazardous Chemical ☐ Hazardous Class Purpose 1,2-Diethylhydrazine is a flammable, acute toxin and possible carcinogen. Can cause skin sensitization and carcinogen by inhalation (under Chromium compounds). 1,2-Diethylhydrazine can be absorbed through the skin. Breathing in vapors can irritate the respiratory tract and can cause the tremors and shortness of breath. Severe poisoning can be fatal. Physical & Chemical Properties/Definition of Chemical Group CAS#: 1615-80-1 Class: Toxic, Carcinogen, Flammable Molecular Formula: C4H12N2 Form (physical state): liquid Color: colorless 1,2-Diethylhydrazine 1 Date: Click here to enter a date. Modified from SOP templates developed by UCLA EH&S (http://www.sop.ehs.ucla.edu/) Boiling point: 82 - 87 °C Potential Hazards/Toxicity 1,2-Diethylhydrazine is a flammable, acute toxin and possible carcinogen. 1,2-Diethylhydrazine can be absorbed through the skin. Breathing in vapors can irritate the respiratory tract and can cause the tremors and shortness of breath. Severe poisoning can be fatal. May cause sensitization by skin contact. May cause irritation of the digestive tract. May be harmful if swallowed and may cause respiratory tract irritation. Harmful if inhaled. Has a permissible exposure limit of 0.5 ppm averaged over 8 hours. Engineering Controls Handle using a chemical fume hood with good ventilation and electrically grounded lines and equipment. Personal Protective Equipment (PPE) Respirator Protection If lab personnel would like to use respirator on a voluntary basis, they must be trained and fit-tested by EH&S. This is a regulatory requirement. (http://or.ucsf.edu/ehs/8193-DSY/version/default/part/4/data/) Hand Protection Gloves must be worn. Use proper glove removal technique to avoid any skin contact. Nitrile gloves are recommended. NOTE: Consult with your preferred glove manufacturer to ensure that the gloves you plan on using are compatible with 1,2-Diethylhydrazine. Refer to glove selection chart from the links below: http://www.ansellpro.com/download/Ansell_8thEditionChemicalResistanceGuide.pdf OR http://www.allsafetyproducts.biz/page/74172 OR http://www.showabestglove.com/site/default.aspx OR http://www.mapaglove.com/ Eye Protection ANSI approved properly fitting safety glasses or chemical splash goggles. Face shield is also recommended. Skin and Body Protection Flame resistant/cotton lab coats must be worn and be appropriately sized for the individual and buttoned to their full length. Laboratory coat sleeves must be of sufficient length to prevent skin exposure while wearing gloves. Full length pants and close-toed shoes must be worn at all times by all individuals that are occupying the laboratory area. The area of skin between the shoe and ankle should not be exposed. Hygiene Measures 1,2-Diethylhydrazine 2 Date: Click here to enter a date. Modified from SOP templates developed by UCLA EH&S (http://www.sop.ehs.ucla.edu/) Wash thoroughly and immediately after handling. Remove any contaminated clothing and wash before reuse. First Aid Procedures If inhaled Move into the fresh air immediately and give oxygen. If not breathing give artificial respiration. Seek medical attention immediately. In case of skin contact Immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Wash any contaminated clothing before reuse. Thoroughly clean shoes before reuse. Seek medical attention immediately. In case of eye contact Check for and remove any contact lenses. Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician. Seek immediate medical attention and continue eye rinse during transport to hospital. If swallowed Do NOT induce vomiting unless directed by medical personnel. Never give anything by mouth to an unconscious person. Seek medical attention immediately. Special Handling and Storage Requirements Precautions for safe handling: Avoid contact with skin and eyes and inhalation. Keep away from sources of ignition. Avoid heat and shock or friction when handling. Conditions for safe storage: Flammable materials should be stored in a flammable storage cabinet. Keep container tightly closed in a cool, dry, and well-ventilated. Keep away from incompatible materials and conditions. Store in original container. Store away from heat sources and in a flame proof area. Keep cool and protect from sunlight. Special Handling and Storage Requirements Precautions for safe handling Avoid contact with skin and eyes. Avoid inhalation of vapor or mist. Keep away from sources of ignition (such as Bunsen burners). Take measures to prevent the build-up of electrostatic charge. Conditions for safe storage Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Possibility of hazardous reactions Vapors may form explosive mixture with air. 1,2-Diethylhydrazine 3 Date: Click here to enter a date. Modified from SOP templates developed by UCLA EH&S (http://www.sop.ehs.ucla.edu/) Conditions to avoid Heat, flames and sparks. Extremes of temperature and direct sunlight. Materials to avoid Oxygen, Oxidizing agents, Halogens, Reducing agents, Perchlorates, Trimethylaluminum Hazardous decomposition products Hazardous decomposition products formed under fire conditions. - Carbon oxides Spill and Accident Procedure Chemical Spill Dial 9-911 from campus phone or 415-476-1414 from cell phone or 415-2068522 (SFGH only) Spill – Assess the extent of danger. Assist contaminated or injured persons. Evacuate the spill area. Avoid breathing vapors. If possible, confine the spill to a small area using a spill kit or absorbent material. Keep others from entering contaminated area (e.g., use caution tape, barriers, etc.). Small (<1 L) – If you have training, you may assist in the clean-up effort. Use appropriate personal protective equipment and clean-up material for chemical spilled. Double bag spill waste in clear plastic bags, label and take to the next chemical waste pick-up. Large (>1 L) – Dial 9-911 from campus phone or 415-476-1414 from cell phone or 415-2068522 (SFGH only) for assistance. Chemical Spill on Body or Clothes – Remove clothing and rinse body thoroughly in emergency shower for at least 15 minutes. If discomfort persists, proceed to the Emergency Department. If no further discomfort is experienced, have the SDS ready and contact Poison Control Hotline at 1-800222-1222 for further exposure information. Notify your direct supervisor and EH&S at 415-4761300 during work hours, or 9-911 during non-working hours and weekends. Chemical Splash Into Eyes – Immediately rinse eyeball and inner surface of eyelid with water for 15 minutes by forcibly holding the eye open. If discomfort persists, proceed to the Emergency Department. If no further discomfort is experienced, have the SDS ready and contact Poison Control Hotline at 1-800-222-1222 for further exposure information. Notify your direct supervisor and EH&S at 415-476-1300 during work hours, or 9-911 during non-working hours and weekends. Medical Emergency Dial 9-911 (campus phone) or 476-6911 (cell phone) Note: All serious injuries must be reported to EH&S at 415-476-1300 within 8 hours. Non-Life Threatening Emergency– Go to Occupational Health Programs (OHP) Clinic, 415-8857580, 2330 Post Street, Suite 460 Hours of Operation for Appointments: Monday - Friday 7:30 a.m. - 4:00 p.m. (except Holidays). 1,2-Diethylhydrazine 4 Date: Click here to enter a date. Modified from SOP templates developed by UCLA EH&S (http://www.sop.ehs.ucla.edu/) Note: All serious injuries must be reported to EH&S at 415-476-1300 within 8 hours. Needle stick/puncture exposure (as applicable to chemical handling procedure) – Wash the affected area with antiseptic soap and warm water for 15 minutes. For mucous membrane exposure, flush the affected area for 15 minutes using an eyewash station. Page the needle stick nurse by dialing 415-353-7842 (STIC). Decontamination/Waste Disposal Procedure Clean contaminated surfaces with soap and water and paper towels. Dispose of the paper towels as hazardous waste. Safety Data Sheet (SDS) Location Online SDS can be accessed at http://or.ucsf.edu/ehs/7241-DSY/msds.html Protocol/Procedure Quantities covered by this SOP: ______ (g , ml) to _______ (g, ml) Temperature range covered by this SOP: __ °C – __ °C General Overview and Purpose: Enter the experimental purpose Procedure: Enter experimental procedure. You can copy procedure from your lab notebook or from literature. NOTE Any deviation from this SOP requires approval from the Principal Investigator. 1,2-Diethylhydrazine 5 Date: Click here to enter a date. Modified from SOP templates developed by UCLA EH&S (http://www.sop.ehs.ucla.edu/)