22793 version 1 Page 1 of 4 Demonstrate knowledge of liquefied petroleum gas (LPG) for automotive and/or domestic use Level 2 Credits 2 Purpose This unit standard is for people in service stations or service centres who dispense or handle LPG. People credited with unit standard are able to demonstrate knowledge of: LPG as a fuel; safety relating to LPG dispensing and/or handling; and LPG cylinders. Subfield Motor Industry Domain Automotive Sales Status Registered Status date 25 June 2007 Date version published 25 June 2007 Planned review date 31 December 2011 Entry information Open. Replacement information This unit standard and unit standard 22792 replaced unit standard 401. Accreditation Evaluation of documentation by NZQA and industry. Standard setting body (SSB) NZ Motor Industry Training Organisation Accreditation and Moderation Action Plan (AMAP) reference 0014 This AMAP can be accessed at http://www.nzqa.govt.nz/framework/search/index.do. Special notes 1 Enactments applicable to this unit standard include but are not limited to – Hazardous Substances and New Organisms (HSNO) Act 1996; Health and Safety in Employment Act 1992; AS/NZS 1596:2002, The storage and handling of LP Gas. 2 AS/NZS 1596:2002 can be sourced from Standards New Zealand, Private Bag 2439, Wellington 6020, website http://www.standards.co.nz. New Zealand Qualifications Authority 2016 22793 version 1 Page 2 of 4 3 Definitions Company requirements refer to instructions to staff on policy and procedures which are documented in memo or manual format and are available in the workplace. These requirements include but are not limited to – company specifications and procedures, work instructions, manufacturer specifications, product quality specifications, and legislative requirements. Serious leak refers to an LPG leak that cannot be quickly controlled by those present on site. 4 This unit standard and Unit 22792, Dispense liquefied petroleum gas (LPG) to fill a portable cylinder meet assessment outcomes for approved fillers as defined under the HSNO Act 1996. Training of the Approved Filler can be carried out by a Site Trainer or Test Certifier under the LPG Association Cylinder Filling Training Programme. Enquires relating to the LPG Association Cylinder Filling Training Programme can be directed to the LPG Association of New Zealand, telephone 04 473 9519, website http://www.lpga.co.nz/. Elements and performance criteria Element 1 Demonstrate knowledge of LPG as a fuel. Performance criteria 1.1 Properties of LPG are described in accordance with the product manufacturer specifications. Range 1.2 composition, odour, relative density, liquid and gaseous phases, ignition point, octane rating. Uses of LPG are described in accordance with the product manufacturer specifications. Range includes but is not limited to – heating, fuel, refrigeration, manufacturing, lighting, cooking. Element 2 Demonstrate knowledge of safety relating to LPG dispensing and/or handling. Performance criteria 2.1 Safety provisions at a worksite are described in accordance with legislative requirements. Range emergency shutdown procedures, safety notices, fire fighting equipment, storage area. New Zealand Qualifications Authority 2016 22793 version 1 Page 3 of 4 2.2 Personal safety precautions to take when handling LPG are identified in accordance with legislative requirements. Range 2.3 Action in event of a leak is explained in accordance with AS/NZS 1596:2002. Range 2.4 serious leak at a worksite, at a cylinder valve, at the fill point. Action in event of fire is outlined in accordance with AS/NZS 1596:2002 and company requirements. Range 2.5 includes but is not limited to – safety glasses, safety gloves. leaks burning at source, fire involving vehicles or equipment; involving emergency services. First aid and emergency procedures to be implemented are identified. Range cold contact burns, heat burns, eye contamination, gassing. Element 3 Demonstrate knowledge of LPG cylinders. Performance criteria 3.1 Main parts of an LPG cylinder are identified. Range 3.2 Cylinder markings are interpreted in accordance with legislative requirements. Range 3.3 may include but is not limited to – body, main service valve, ullage bleed valve, pressure relief valve, valve protection ring, foot ring. Department of Labour (LAB) number, serial number, specification to which the cylinder was manufactured, cylinder test pressure (TP), manufacturer name or mark, date of manufacture, water capacity (WC), tare weight (TW), empty weight (EW), identification mark of the manufacturer’s inspection authority, date of any subsequent retest, identification mark of the test station who completed the retest. Cylinder types and their features are identified. Range small leisure equipment, portable home heating and barbecue cylinders, forklift and materials handling equipment cylinders, domestic or commercial cylinders, vehicle tanks. Please note Providers must be accredited by NZQA, or an inter-institutional body with delegated authority for quality assurance, before they can report credits from assessment against unit standards or deliver courses of study leading to that assessment. New Zealand Qualifications Authority 2016 22793 version 1 Page 4 of 4 Industry Training Organisations must be accredited by NZQA before they can register credits from assessment against unit standards. Accredited providers and Industry Training Organisations assessing against unit standards must engage with the moderation system that applies to those standards. Accreditation requirements and an outline of the moderation system that applies to this standard are outlined in the Accreditation and Moderation Action Plan (AMAP). The AMAP also includes useful information about special requirements for organisations wishing to develop education and training programmes, such as minimum qualifications for tutors and assessors, and special resource requirements. Comments on this unit standard Please contact the NZ Motor Industry Training Organisation jlane@mito.org.nz if you wish to suggest changes to the content of this unit standard. New Zealand Qualifications Authority 2016