25786 version 1 Page 1 of 4 Carry out outdoor visitor structure inspections Level 4 Credits 8 Purpose People credited with this unit standard are able to: carry out pre-inspection planning and processes for inspecting an outdoor visitor structure (OVS); carry out inspection of an outdoor visitor structure; and carry out postinspection processes. Subfield Environment Domain Conservation Status Registered Status date 22 May 2009 Date version published 22 May 2009 Planned review date 31 December 2012 Entry information Open. Accreditation Evaluation of documentation and visit by NZQA and industry. Standard setting body (SSB) The Skills Organisation Accreditation and Moderation Action Plan (AMAP) reference 0121 This AMAP can be accessed at http://www.nzqa.govt.nz/framework/search/index.do. Special notes 1 All activities must comply with the policies, procedures, and requirements of the organisations involved; the ethical codes and standards of relevant professional bodies; and any relevant cultural, legislative and/or regulatory requirements including the Standards New Zealand Handbook SNZ HB 8630:2004 Tracks and outdoor visitor structures. 2 Legislation relevant to this unit standard may include but is not limited to: Building Act 2004, Conservation Act 1987, Hazardous Substances and New Organisms Act 1996 (HSNO Act), Health and Safety in Employment Act 1992, Local Government Act 2002, Public Works Act 1981, Reserves Act 1977, Resource Management Act 1991, Treaty of Waitangi Act 1975. 3 Definitions New Zealand Qualifications Authority 2016 25786 version 1 Page 2 of 4 Organisational requirements include the documented policy, procedures, and methodologies of the organisation. They include requirements documented in organisation and site health and safety plans, quality assurance documents, and contract work programmes. Outdoor visitor structure is a structure not intended for human habitation and open for public access which may include but is not limited to – boardwalks, pedestrian bridges, viewing platforms, stairs, stiles, ramps, cableways. 4 Candidates are required to provide evidence of three different outdoor visitor structure inspections. Elements and performance criteria Element 1 Carry out pre inspection planning and processes for inspecting an outdoor visitor structure (OVS). Performance criteria 1.1 Outdoor visitor structure is identified as due for inspection using organisational information. Range 1.2 information includes but is not limited to – OVS type, location of OVS, previous inspection results, work reports. Resources and equipment required to carry out inspection are collected and checked in accordance with organisational requirements. Range equipment and resources may include but are not limited to – materials, tools, documents, inspection schedule, safety equipment, recording equipment. Element 2 Carry out an inspection of an outdoor visitor structure. Performance criteria 2.1 OVS identified as due for inspection is physically located using organisational information. 2.2 OVS is inspected and its condition is recorded in accordance with organisational requirements. 2.3 Any defects are identified and recorded in accordance with organisational requirements. 2.4 Minor defects are repaired in accordance with organisational requirements. New Zealand Qualifications Authority 2016 25786 version 1 Page 3 of 4 2.5 Where major defects are identified measures are taken to ensure public safety in accordance with organisational requirements. Range measures may include but are not limited to – restricting public access to dangerous areas, posting signage, posting hazard tape, safety notices, changing OVS status to closed. 2.6 OVS is photographed and/or sketched, where applicable, in accordance with organisational requirements. 2.7 Inspection of the OVS is carried out safely in accordance with organisational requirements. Element 3 Carry out post inspection processes. Performance criteria 3.1 Inspection information is transferred and recorded in accordance with organisational requirements. 3.2 Photographs and/or sketches are processed, where applicable, in accordance with organisational requirements. 3.3 Any major defects and hazards identified during inspection are reported to the appropriate personnel in accordance with organisational requirements. Range appropriate personnel may include but are not limited to – managers, engineers, specialist inspectors, tradespersons. Please note Providers must be accredited by NZQA, or an inter-institutional body with delegated authority for quality assurance, before they can report credits from assessment against unit standards or deliver courses of study leading to that assessment. Industry Training Organisations must be accredited by NZQA before they can register credits from assessment against unit standards. Accredited providers and Industry Training Organisations assessing against unit standards must engage with the moderation system that applies to those standards. Accreditation requirements and an outline of the moderation system that applies to this standard are outlined in the Accreditation and Moderation Action Plan (AMAP). The AMAP also includes useful information about special requirements for organisations wishing to develop education and training programmes, such as minimum qualifications for tutors and assessors, and special resource requirements. New Zealand Qualifications Authority 2016 25786 version 1 Page 4 of 4 Comments on this unit standard Please contact The Skills Organisation info@skills.org.nz if you wish to suggest changes to the content of this unit standard. New Zealand Qualifications Authority 2016