CMSTOOLS MACHINE CONFIGURATION FILES

advertisement
C.M.S.-Software Division
CMS-TOOLS GENERAL CONFIGURATION FILES
Rev. A of 12/11/1997
English Version
CMS-TOOLS General configuration files 1
SUMMARY
1. FOREWORD ........................................................................................................................................................... 3
2. LIST OF GENERAL CONFIGURATION FILES............................................................................................... 4
3. CMSWIN.INI .......................................................................................................................................................... 5
3.1 SECTION [GENERALI] ............................................................................................................................................... 5
3.2 SECTION [CONFCOLORI] .......................................................................................................................................... 6
3.3 SECTION [FONT] ....................................................................................................................................................... 6
3.4 SECTION [CMSTRAS]................................................................................................................................................ 6
3.5 SECTION [TAV CREATOR SETTINGS] ........................................................................................................................ 7
3.6 SECTION [PASSWORDDLG] ....................................................................................................................................... 7
3.7 SECTION [CAM SETTINGS] ...................................................................................................................................... 7
3.8 SECTION [DISP] ........................................................................................................................................................ 8
3.9 SECTION [NEST] ....................................................................................................................................................... 8
3.10 SECTION [PRINT] .................................................................................................................................................... 8
3.11 SECTION [DIGITCONF]............................................................................................................................................ 8
3.12 SECTION [WINDOWS] ............................................................................................................................................. 9
3.13 SECTION [MONDO] ................................................................................................................................................. 9
3.14 SECTION [GENERALI-SUMMARY] ........................................................................................................................... 9
3.15 SECTION [GENERALI-BAR*] ................................................................................................................................... 9
CMS-TOOLS General configuration files 2
Page left intentionally blank
CMS-TOOLS General configuration files 3
1. FOREWORD
The CMS-TOOLS product can be easily customized, partly from the user interface, partly editing
some configuration files.
Goal of this document is to explain all the configuration files of the CMS-TOOLS product with
the exception of the machine configuration files that are explained in another manual.
Some configuration examples will complete this documentation.
CMS-TOOLS General configuration files 4
2. LIST OF GENERAL CONFIGURATION FILES
All these files must stay in the CmsWinTools root directory.
CMSWIN.INI
general configuration data
CMS-WIN.MNU
CMS-WIN.TXT
TOOLBAR.CFG
menu configuration data
messages
toolbar configuration data
CMS-WIN.COL
CMS-COL.FAC
VIDEO.CO3
current color configuration data
original color configuration data by Cms
geometrical fonts configuration data
USER.CUR
current project and machine data
CMS-TEXW.CFG
pocketing user interface, default and constraints values configuration
DIGIT.CON
DIGIT.DAT
CMS-INTE.CFG
CMS-INTE.DAT
general configuration data for digitizing
geometrical configuration data for digitizing
interactive digitizing settings user interface, default and constraints
values configuration
interactive digitizing settings configuration
NCI-CSF.CFG
NCL-NAS.CFG
PANNELLO.DAT
NCI (MasterCam) import configuration data
APT/NCL (Catia, Pro/E) import configuration data
R0X (Alma) import configuration data
WCON-CIC.CFG
machine cycle settings user interface, default and constraints values
configuration
machine command settings user interface, default and constraints values
configuration
digitizing settings user interface, default and constraints values
configuration
machine general settings user interface, default and constraints values
configuration
machine geometrical settings user interface, default and constraints
values configuration
language configuration data
machine origins settings user interface, default and constraints values
configuration
machine heads settings user interface, default and constraints values
configuration
machine multiple-heads settings user interface, default and constraints
values configuration
WCON-COM.CFG
WCON-DIG.CFG
WCON-GEN.CFG
WCON-GEO.CFG
WCON-LIN.CFG
WCON-ORI.CFG
WCON-TES.CFG
WCON-TMU.CFG
CMSWTOOL.GLC
BINARY.COD
start-up GLC configuration data
enabling codes for binary GLC programs
CMS-TOOLS General configuration files 5
3. CMSWIN.INI
The structure of this file is like the one of Microsoft INI files :
[section_name1]
key1_1=value1_1
key1_2=value1_2
...
[section_name2]
key2_1=value2_1
key2_2=value2_2
...
where section_nameN and keyI_L are strings identifing sections and keys, while valueI_L are
character strings or numerical values, depending on the key.
In the following descriptions, the keys with undescored characters are to set by hand, the other
ones are used by the program itself to remember the previous state.
3.1 Section [Generali]
UndoRedoStep=number
where number is the maximum number of undo steps allowed (default 10).
UndoRedoDimens=value
where value is the maximum dimension of the project, in Bytes, to activate Undo/Redo
(default 250000).
Debug=flag
where flag is one of these values :
0 = debug off (default),
1 = debug on;
for the debug modality (prints some more informations on the command line).
DelAllProj=flag
where flag is one of these values :
0 = delete all the files with the name ot the project and extensions LAX, DP?, DL?, LS?,
VAR, ENT, HED, ENS, WMF, WMI (default),
1 = delete all the files with the name ot the project and extensions like previous option,
plus CNC, CTC, ATT;
for the command FileDelete.
MostraToolBar=flag
MostraStatusBar=flag
GrandezzaToolBar=flag
StandardToolBar=flag
AllDialogPosition=flag
SalvaDesktop=flag
are directly set by the WindowCustomize dialog.
PosWindow=values
is directly set by the program with the origin and dimensions (in pixels) of the main window.
CMS-TOOLS General configuration files 6
3.2 Section [ConfColori]
NumConfColori=15
Color1=6385 CL1
Color2=6386 CL2
Color3=6387 CL3
Color4=6388 CL4
Color5=6389 CL5
Color6=6390 CL6
Color7=6391 CL7
Color8=6392 CL8
Color9=6393 CL9
Color10=6394 C10
Color11=6445 BKU
Color12=6446 PRI
Color13=6447 DFN
Color14=6448 AUX
Color15=6449 SER
are used by the dialog WindowColors and must be like here.
3.3 Section [Font]
Height=12
Weight=400
Italic=0
Underline=0
PitchAndFamily=1
FaceName=Courier
are used to set the current font on the internal editor, the values here reported are the defaults.
3.4 Section [CmsTras]
RPP_TYPE=flag
where flag is one of these values :
0 = import NC code in a project, using current machine with tools setup,
1 = transform NC code in a new NC code (default),
2 = transform NC code in a new NC code, keeping mirror, cycles and so on;
for the Reverse Post Processor.
RPP_EGT=val
where val is one of these values :
0.1 ( 0.004 if inches) to use the medium point algorithm,
10000 to skip this algorithm (default).
for the Reverse Post Processor.
RPP_CTV= flag min max perc var_max
where flag is used to activate the feed control (0=no(default), 1=yes,);
min is the minimum feed;
max is the maximum speed;
perc is the minimum percentual variation to emit the change in feed;
var_max is the maximum absolute variation from the previous line.
for the Reverse Post Processor.
CMS-TOOLS General configuration files 7
WMI=flag
where flag is one of these values :
0 = do not create WMI files when generate WMF files,
1 = create WMI files;
for the export and save project.
LAYER_HOLES=layer_key
where layer_key is a string that must be inside the name of the layers with the holes;
for the DXF import.
3.5 Section [Tav Creator Settings]
FreeSelection=flag
where flag is one of these values :
0 = load the table of the current machine,
1 = load the table the user select by an apposite dialog;
for the Machine Table Configuration dialog.
3.6 Section [PasswordDlg]
Password=string
where string is the password to use (default cms);
for the Upgrade of Tools database.
3.7 Section [CAM Settings]
ProcessDataType=number
PieceProcessData=flag
AllParts=flag
XDimProcessDataDialog=value
YDimProcessDataDialog=value
are directly set and used by the Nc GenerateProcess Data dialog.
CTableSortingEnable= flag
is directly set and used by the Nc GenerateManage Attribute Table dialog.
PrintDraw=flag
PrintNc= flag
PrintProcessData= flag
PrintSetup= flag
PrintTime= flag
are directly set and used by the Nc GeneratePrint All dialog.
SimulationType=value
is directly set and used by the Nc GenerateSimulation dialog.
ProfLegenda= flag
ProfFill= flag
ProfMultDist=value
ProfMultInvert=flag
ProfMultDirez= flag
are directly set and used by the Nc GenerateProfiling dialog.
CMS-TOOLS General configuration files 8
3.8 Section [Disp]
Snap=flag
ShowOrigins=flag
InterfWithBox=flag
ValSnap=value
ValIntSec= value
ValExtSec= value
ValSovraL= value
ID_gruppo=number
NumOttVent= number
NumMinVent= number
PassoRicerca= value
Fast=flag
AllGroups=flag
are directly set and used by the Nc GeneratePiece Disposition dialog.
3.9 Section [Nest]
Panel_0=values
ShowKerf=flag
StopOnInterference=flag
ShowPanel=flag
DeleteOnSave=flag
PtPDistance= values
PtBDistance= values
are directly set and used by the TransformNesting dialog.
3.10 Section [Print]
Bordo= flag
Margini= flag
MargineSuperiore= value
MargineInferiore= value
MargineDestro= value
MargineSinistro= value
are directly set and used by the FilePrint dialog.
3.11 Section [DigitConf]
Direction=value
Len=value
Fi=value
DefDigit=flag
ContinueWithHole=flag
CorrSide=value
are directly set and used by the DrawDigitize dialog.
CMS-TOOLS General configuration files 9
3.12 Section [Windows]
Set and used by the progam, not to modify.
3.13 Section [Mondo]
Set and used by the progam, not to modify.
3.14 Section [Generali-Summary]
Set and used by the progam, not to modify.
3.15 Section [Generali-Bar*]
Set and used by the progam, not to modify.
Download