SAFLOK™ 700 CONCEALED-FIX SHEETING
(* refer to table indicated)
The roof sheeting shall be double-interlocking concealed-fix SAFINTRA SAFLOK™ 700 profile rollformed in continuous lengths and cut to length by a pneumatic cut-off process from certified
*material. All sheeting is to be clearly marked on the reverse side at one-metre intervals indicating
thickness, material quality, coating thickness and paint system. A certificate verifying material
compliance shall be issued by the manufacturer.
The profile shall be roll formed with 4 ribs of 41.5 mm depth, centres not exceeding 233 mm and a
cover width not exceeding 700 mm. The male rib is to include spurs to ensure a double interlocking
action with adjacent sheets. Two stiffening ribs shall be incorporated in each pan.
Patented and marked SAFLOK™ 700 clips shall be used to secure the sheet, fixed to (timber/steel)
purlins or rails at spacings in accordance with the manufacturer’s recommendations. The clip shall
be fixed with SAFINTRA FIXTITE™ or other approved fasteners in accordance with the manufacturer’s
recommendations and material warranty requirements.
Safintra approved flashings and accessories shall be used in accordance with the manufacturer’s
recommendations and material warranty requirements.
Note to specifier: Requiring that a vapour barrier be installed below the sheet is considered best practice for all metal roofing, but is
imperative in high condensation regions.
SAFLOK™ 410 CONCEALED-FIX SHEETING
(* refer to table indicated below)
The roof sheeting shall be double-interlocking concealed-fix SAFINTRA SAFLOK™ 410 profile rollformed in continuous lengths and cut to length by a pneumatic cut-off process from certified
*material. All sheeting is to be clearly marked on the reverse side at one-metre intervals indicating
thickness, material quality, coating thickness and paint system. A certificate verifying material
compliance shall be issued by the manufacturer.
The profile shall be roll formed with 3 ribs of 41 mm depth, at centres not exceeding 205 mm and a
cover width not exceeding 410 mm. The male rib is to include spurs to ensure a double interlocking
action with adjacent sheets. Two stiffening ribs shall be incorporated in each pan.
Patented and marked SAFLOK™ 410 clips shall be used to secure the sheet, fixed to (timber/steel)
purlins or rails at spacings in accordance with the manufacturer’s recommendations. The clip shall
be fixed with SAFINTRA FIXTITE™ or other approved fasteners in accordance with the manufacturer’s
recommendations and material warranty requirements.
Safintra approved flashings and accessories shall be used in accordance with the manufacturer’s
recommendations and material warranty requirements.
Note to specifier: Requiring that a vapour barrier be installed below the sheet is considered best practice for all metal roofing, but is
imperative in high condensation regions.
1
Specifications version updated May 2015
NEWLOK™ STANDING SEAM SHEETING - SNAPPED
(* refer to table indicated below)
The roof sheeting shall be snap locked SAFINTRA NEWLOK™ profile roll-formed in continuous lengths
and cut to length by a pneumatic cut-off process from certified *material. All sheeting is to be clearly
marked on the reverse side at one-metre intervals indicating thickness, material quality, coating
thickness and paint system. A certificate verifying material compliance shall be issued by the
manufacturer.
The profile shall be roll formed with 2 ribs of 50.8mm depth, centres and cover width not exceeding
445mm. The female rib is snapped into position over the male rib. Two stiffening ribs shall be
incorporated in the pan.
Patented and marked NEWLOK™ clips shall be used to secure the sheets, fixed to (timber/steel)
purlins or rails at spacings in accordance with the manufacturer’s recommendations. The clip shall be
fixed with SAFINTRA FIXTITE™ or other approved fasteners in accordance with the manufacturer’s
recommendations and material warranty requirements.
Safintra approved flashings and accessories shall be used in accordance with the manufacturer’s
recommendations and material warranty requirements.
Note to specifier: Requiring that a vapour barrier be installed below the sheet is considered best practice for all metal roofing, but is
imperative in high condensation regions.
NEWLOK™ STANDING SEAM SHEETING - SEAMED
(* refer to table indicated below)
The roof sheeting shall be snap locked and seamed SAFINTRA NEWLOK™ profile roll-formed in
continuous lengths and cut to length by a pneumatic cut-off process from certified *material. All
sheeting is to be clearly marked on the reverse side at one-metre intervals indicating thickness,
material quality, coating thickness and paint system. A certificate verifying material compliance shall
be issued by the manufacturer.
The profile shall be roll formed with 2 ribs of 50.8mm depth, centres and cover width not exceeding
445mm. The female rib is snapped into position over the male rib and then seamed. Two stiffening
ribs shall be incorporated in the pan.
Patented and marked NEWLOK™ clips shall be used to secure the sheets, fixed to (timber/steel)
purlins or rails at spacings in accordance with the manufacturer’s recommendations. The clip shall be
fixed with SAFINTRA FIXTITE™ or other approved fasteners in accordance with the manufacturer’s
recommendations and material warranty requirements.
Safintra approved flashings and accessories shall be used in accordance with the manufacturer’s
recommendations and material warranty requirements.
Note to specifier: Requiring that a vapour barrier be installed below the sheet is considered best practice for all metal roofing, but is
imperative in high condensation regions.
2
Specifications version updated May 2015
CLASSICORR™ CORRUGATED PIERCED-FIX SHEETING
(* refer to table indicated below)
The roof sheeting shall be SAFINTRA CLASSICORR™ CORRUGATED roof sheeting roll-formed and cut
to length by a pneumatic cut-off process from certified *material. All sheeting is to be clearly marked
on the reverse side at one-metre intervals indicating thickness, material quality, coating thickness
and paint system. A certificate verifying material compliance shall be issued by the manufacturer.
The profile shall be formed with the rib height of 17.5mm and 10.5 corrugations at 76mm centers
and a nett cover width of 762mm when lapped. The sheet shall be secured to (timber/steel) purlins
or rails at spacings in accordance with the manufacturer’s recommendations.
CLASSICORR™ CORRUGATED sheets shall be fixed through the crests of alternate ribs with 3
fasteners per sheet per purlin, with side laps to be stitched at 500mm centers between purlins. They
shall be fixed with SAFINTRA FIXTITE™ or other approved fasteners in accordance with the
manufacturer’s recommendations and material warranty requirements.
Safintra approved flashings and accessories shall be used in accordance with the manufacturer’s
recommendations and material warranty requirements.
Note to specifier: Requiring that a vapour barrier be installed below the sheet is considered best practice for all metal roofing, but is
imperative in high condensation regions.
TUFDEK™ IBR PIERCED-FIX SHEETING
(* refer to table indicated below)
The roof sheeting shall be SAFINTRA TUFDEK™ IBR roll-formed and cut to length by a pneumatic cutoff process from certified *material. All sheeting is to be clearly marked on the reverse side at onemetre intervals indicating thickness, material quality, coating thickness and paint system. A
certificate verifying material compliance shall be issued by the manufacturer.
The profile shall be formed with 5 trapezoidal ribs each 36,5mm high, at 171.5mm centers with a
nett cover width of 686mm when lapped. The sheet shall be secured to (timber/steel) purlins or
rails at spacings in accordance with the manufacturer’s recommendations.
SAFINTRA TUFDEK™ IBR sheets shall be fixed through the crests at every second crest, at
intermediate purlins and at every crest at eaves purlins, with side laps to be stitched at 500mm
centers between purlins. They shall be fixed with SAFINTRA FIXTITE™ or other approved fasteners in
accordance with the manufacturer’s recommendations and material warranty requirements.
Safintra approved flashings and accessories shall be used in accordance with the manufacturer’s
recommendations and material warranty requirements.
Note to specifier: Requiring that a vapour barrier be installed below the sheet is considered best practice for all metal roofing, but is
imperative in high condensation regions.
3
Specifications version updated May 2015
WIDEDEK™ PIERCED-FIX SHEETING
(* refer to table indicated below)
The roof sheeting shall be SAFINTRA WIDEDEK™ roll-formed and cut to length by a pneumatic cut-off
process from certified *material. All sheeting is to be clearly marked on the reverse side at onemetre intervals indicating thickness, material quality, coating thickness and paint system. A
certificate verifying material compliance shall be issued by the manufacturer.
The profile shall be formed with 5 trapezoidal ribs each 29 mm high, at 191mm centers, and a nett
cover width of 760 mm when lapped. The sheet shall be secured to (timber/steel) purlins or rails at
spacings in accordance with the manufacturer’s recommendations.
SAFINTRA WIDEDEK™ sheets shall be fixed through the crests at every second crest, at intermediate
purlins and at every crest at eaves purlins, with side laps to be stitched at 500mm centers between
purlins. They shall be fixed with SAFINTRA FIXTITE™ or other approved fasteners in accordance with
the manufacturer’s recommendations and material warranty requirements.
Safintra approved flashings and accessories shall be used in accordance with the manufacturer’s
recommendations and material warranty requirements.
Note to specifier: Requiring that a vapour barrier be installed below the sheet is considered best practice for all metal roofing, but is
imperative in high condensation regions.
FLUTELINE™ PIERCED-FIX SHEETING
(* refer to table indicated below)
The roof sheeting shall be the SAFINTRA FLUTELINE™ Industrial 7 profile roll-formed and cut to
length by a pneumatic cut-off process from certified *material. All sheeting is to be clearly marked on
the reverse side at one-metre intervals indicating thickness, material quality, coating thickness and
paint system. A certificate verifying material compliance shall be issued by the manufacturer.
The profile shall be formed with 8 trapezoidal ribs each 38 mm high, at 127 mm centers, and a nett
cover width of 889 mm when lapped. The sheet shall be secured to (timber/steel) purlins or rails at
spacings in accordance with the manufacturer’s recommendations.
SAFINTRA FLUTELINE™ Industrial 7 sheets shall be fixed through the crests at first, third, fourth and
sixth crest of each sheet and at every crest at eaves purlins, with side laps to be stitched at 500mm
centers between purlins. They shall be fixed with SAFINTRA FIXTITE™ or other approved fasteners in
accordance with the manufacturer’s recommendations and material warranty requirements.
Safintra approved flashings and accessories shall be used in accordance with the manufacturer’s
recommendations and material warranty requirements.
Note to specifier: Requiring that a vapour barrier be installed below the sheet is considered best practice for all metal roofing, but is
imperative in high condensation regions.
4
Specifications version updated May 2015
TRIMFLUTE™ PIERCED-FIX SHEETING
(* refer to table indicated below)
The roof sheeting shall be the SAFINTRA TRIMFLUTE ™ profile roll-formed and cut to length by a
pneumatic cut-off process from *material. All sheeting is to be clearly marked on the reverse side at
one-metre intervals indicating thickness, material quality, coating thickness and paint system. A
certificate verifying material compliance shall be issued by the manufacturer.
The profile shall be formed with 6 trapezoidal ribs each 26.5 mm high, at 203 mm centers, and a nett
cover width of 1015 mm when lapped. The sheet shall be secured to (timber/steel) purlins or rails
at spacings in accordance with the manufacturer’s recommendations.
SAFINTRA TRIMFLUTE ™ sheets shall be fixed through the crests at every second crest, at every crest
at eaves purlins, and with side laps to be stitched at 500mm centers between purlins. They shall be
fixed with SAFINTRA FIXTITE™ or other approved fasteners in accordance with the manufacturer’s
recommendations and material warranty requirements.
Safintra approved flashings and accessories shall be used in accordance with the manufacturer’s
recommendations and material warranty requirements.
Note to specifier: Requiring that a vapour barrier be installed below the sheet is considered best practice for all metal roofing, but is
imperative in high condensation regions.
VERSATILE™ PIERCED-FIX SHEETING
(* refer to table indicated below)
The roof sheeting shall be the SAFINTRA VERSATILE ™ profile roll-formed and cut to length by a
pneumatic cut-off process from certified *material. All sheeting is to be clearly marked on the
reverse side at one-metre intervals indicating thickness, material quality, coating thickness and paint
system. A certificate verifying material compliance shall be issued by the manufacturer.
The profile shall be roll-formed with 4 large corrugations at 185mm centers with a rib height of
25.5mm giving a nett cover of 740mm when lapped. The sheet shall be secured to (timber/steel)
purlins or rails at spacings in accordance with the manufacturer’s recommendations.
SAFINTRA VERSATILE ™ sheets shall have a tile depth of 300mm, and shall be fixed through the
crests at every second crest (600mm intervals), at every crest at eaves purlins, and with side laps to
be stitched at 500mm centers between purlins. They shall be fixed with SAFINTRA FIXTITE™ or other
approved fasteners in accordance with the manufacturer’s recommendations and material warranty
requirements.
Safintra approved flashings and accessories shall be used in accordance with the manufacturer’s
recommendations and material warranty requirements.
Note to specifier: Requiring that a vapour barrier be installed below the sheet is considered best practice for all metal roofing, but is
imperative in high condensation regions.
5
Specifications version updated May 2015
* MATERIAL AND FINISH FOR SAFINTRA ROOF SHEETING
Select from below:
Coated
Steel
Grade
Thickness






0.47mm
0.5mm
0.53mm
0.55mm
0.58mm
0.60mm
0.47mm
0.5mm
0.53mm
0.55mm
0.58mm
0.60mm
ZINCAL
AZ150
Inland / non
corrosive
conditions
ZINCAL
AZ200
Coastal /
corrosive
conditions
 G550
 G275






ZINCALUME
AZ150
 G550
 G300
 0.47mm
 0.53mm
ZINCALUME
AZ200
 G550
 G300
 0.47mm
 0.53mm
Aluminium
Aluminium
 3004
 9017
 0.7mm
 0.8mm
 G550
 G275
Finishes
 ZINCAL Mill finish.
 COLORPLUS colour coated finish to one side
with Cool Grey backing coat.
 COLORPLUS colour coated to two sides (Not
standard, by special request only)
 ZINCAL Mill finish.
 COLORPLUS ULTIMA colour coated finish to
one side with Cool Grey backing coat.
 COLORPLUS ULTIMA colour coated to two
sides (Not standard, by special request
only)
 ZINCALUME Mill finish.
 COLORBOND colour coated finish to one
side with Shadow Grey backing coat.
 COLORBOND colour coated to two sides
(Not standard, by special request only)
 ZINCALUME Mill finish.
 COLORBOND ULTRA colour coated finish to
one side with Shadow Grey backing coat.
 COLORBOND ULTRA colour coated to two
sides (Not standard, by special request
only)
 MILLTECH Mill finish.
 COLORTECH G4 colour coated finish to one
side with a standard colour backing coat.
 COLORTECH G4 colour coated to two sides
(Not standard, by special request only)
Care has been taken to ensure that the information provided is accurate. SAFINTRA does not assume responsibility for
inaccuracies or misinterpretations of this data.
SAFINTRA is continuously engaged in product development; please ensure that you have the most recent issue of
information from SAFINTRA.
Any questions regarding this specification can be directed to Safintra for clarification, or emailed to
marketing@safintra.co.za.