Benefits of L-3000 HPLC 1 Pump 1.1 The maximum operating pressure: 8000PSI The way we achieve 8000 psi: We design liquid path in accordance with UHPLC standard, and seal can withstand 15000psi. L-3000 HPLC system can continuously work a longer time, and delivery liquid more than 240L at 10000 psi. The benefits of 8000 psi: Provide a wide selection of column Can do rapid analysis, improve efficiency 7 times, and reduce solvent consumption 4 times. Test Sudan dyes 1.2 Higher gradient precision, accuracy and repeatability We repeated test six times, and the gradient precision, accuracy and repeatability is very good. Condition: A:0.1%Isopropyl alcohol solution B:Add 0.1% acetone into phase A Wavelength:254nm Flow rate:1.0mL/min The way we achieve higher gradient precision, accuracy and repeatability. We adopt a unique pressure pulseless technology shown as following: Patented design integrated mixer and damper. Withstand higher pressure and more reliable than diaphragm damper. Two pumps housed in one room largely reduces delay volume Benefits of pressure pulseless Before the pressure pulseless After pressure pulseless 1.3 Higher stability and longer lifetime L-3000 HPLC system can continuously work a longer time, and delivery liquid more than 240L at 10000 psi. The way that we achieve higher stability and longer lifetime: Rigol adopts a unique design to improve the stability and lifetime. Dual-ball check valve provides double security which ensures more stable pressure and more accurate flow rate. Standard configuration: On-line seal wash system 2 UV-Vis Detector 2.1 Patented lamp power design leads to lower dynamic noise and drift. Noise Drift 2.2 Wider linear range: 2.5AU More accurate results of high concentration sample. Simultaneously analysis high concentration sample and trace components. 2.3 Higher sampling rate: 100Hz Compare table of peak 2 3 Solvent organizer On-line seal wash system built in solvent organizer largely extends the service life of seal. An optional on-line vacuum degasser built in it reduces space occupation. Teflon AF degassing membrane efficient, 50 times the normal PTFE material degassing efficiency and greatly reduce the volume of lines and degassing chamber. Vacuum degree: 50mmHg ± 5mmHg 4 Column Oven Intelligent PID temperature control algorithm, the temperature is more accurate: ± 0.1 ℃ 5 Auto sampler PASA Pressure –Assisted Sample Aspiration As low as 0.05% cross contamination Higher repeatability and accuracy Variety of plates for user’s selection. Automatically Mix & Dilute PASA Plates 6 Software 6.1 Better applicability of regulations Fully comply with GLP/GMP, FDA 21 CFR Part 11. No need to re-verify method for conventional analysis Each module complies with GLP Ensure the analytical result traceable and reliable User account management Digital signature 6.2 Easily operate Operation interface 6.3 More powerful data processing ability and customization features Sampling settings interface Method editing interface Real-time acquisition interface Spectrum processing interface Calibration interface Report printing interface Data import and export Batch processing of data Summary • Better durability and stability The Maximum operating pressure:8000 PSI • Better usability and flexibility Low noise:±0.5×10-5AU(254nm, Methanol) Limit of detection:5×10-9g/ml Linear range:2.5AU Gradient accuracy:better ± 1% High sampling rate:100Hz • Easily use and operate RIGOL Chromatography workstation • Longer service life and easy maintenance • Flexible configuration to meet different customer’s REPRESENTANTE DCtech Instrumentação Ltda. Rua Benedita Cardoso Madeira, 825 13295-000 - Itupeva, SP PABX: 11 4591-2813 e-mail: dctech@globallab.com.br / 4496-5165