Errata for Foo (2012)

advertisement
Foo, D. C. Y. (2012). Process Integration for Resource Conservation, CRC Press, Boca
Raton, Florida, US.
ERRATA
(Last updated: 1 September 2015)
Page
s
xviii
Errors
Corrections
13
Line 2 from
bottom
Figure 1.12
… RCNet (with user guide; Process Safety & Environmental Protection,
92(6): 917-928).
There is a typo in the diagram:
13
Figure 1.13
There is a typo in the diagram:
14
Figure 1.14
There is a typo in the diagram:
14
Figure 1.15
The revised diagram:
92
Eq. 4.1
The correct equation should be:
FR, k 
111
Cum. mk
( qk  q R )
.. (chlorine) content of 20 mg/L…
115
Problem 4.9,
last line.
Fig. 4.3
129
Fig. 6.2
There is a typo in the diagram (after step 4b):
138
Line 8 from
bottom
Solution
section for
Example 7.3:
line 8 from
top (solution
section)
Hence, Equation 6.2 determines…
168
There are typos in the labelling of sources. The corrected figure is given as
follows.
… requirement of SK1 (50 t/h) in the FWR. From…
…the second criteria, i.e., FSK3 ≥ FSR2, and hence…
195
Solution
section for
Example 7.4
(line 5 from
Fig 7.21)
Line 8 from
bottom
Problem 7.2,
part (a), line 4
Fig. 8.3
219
Table 9.1
There are typos in the table:
237
Fig 10.4 (a)
Sinks, SKj FSKj (t/h) CSKj (ppm)
SK1
4
10
SK2
1
20
SK3
2
30
SK4
1
40
There are typos in the figure:
240
Line 6 below
Figure 10.6
177
177
183
… a new SK2–SR3 match…
… and 8.2 kg/s, respectively.
There are typos in the diagram:
WW3 has a flowrate of 25 t/h (= 60 – 35 t/h)
241
247
251
270
270
280
301
Line 9 from
top
Line 14 after
Table 10.8
Line 7 from
bottom
Title for
reference of
Bandyopadhy
ay et al.
(2010),
Title for
references of
Chew et al.
(2010a,
2010b)
Table 11.6
Table 11.9
The segments of SR5 and SK6
…flowrate of 47.38 t/h (FWW2 in Table 10.8) and concentration…
WW3 (400 ppm), and WW6
The correct title is: Segregated Targeting for Multiple Resource Networks
Using Decomposition Algorithm
The correct titles are: Flowrate Targeting Algorithm for Interplant Resource
Conservation Network…
There are two typos: FA, HPR should be FA, HQR ; FA, LPR should be FA, LQR
There are typos in the table:
SKj
SK1
SK2
SRi
SR1
SR2
285
Table 11.11
293
Figure 11.8:
x-axis caption
Example
14.3, line just
before
question (1).
Figure
16.10(a)
402
508
510
Line 11 from
top
FSKj (kg/h)
8
3
FSRi (kg/h)
6
2
pH (SKj)
7.2
7.35
pH (SRi)
9
7.7
TSTT (h)
5
7
STT
T (h)
0
3
TEND (h)
6
8
END
T
(h)
1
4
The first entry for the concentration column should be 20 ppm (CRout), rather
than 0 ppm.
The correct caption should be “Flow (ton)”
… and reject streams for the following cases:
The revised figure:
252.16 (0.0556) + 447.84 (0.125) = 700 (0.1) t/h MΩ.m
515
552
553
Problem 16.8,
line 8 from
bottom
Figure 17.3(a)
and (b)
… recovery recovery factor of 0.95 (see Equations 14.18 or 14.22).
Figure 17.3(c)
and (d)
The revised figures:
The revised figures:
Download