SECTION 02829 ELECTRIC GATE OPERATORS Display hidden notes to specifier by using “Tools”/“Options”/“Display”/“Hidden Text”. Copyright 2006-2014 ARCAT, Inc. - All rights reserved. PART 1 GENERAL 1.1 SECTION INCLUDES A. Electric Gate Operators: 1. Residential/Light Commercial DC Linear Actuator (LiftMaster Model LA500DC). 2. Residential DC Linear Actuator (LiftMaster Model LA400DC). 3. Solar Residential DC Linear Actuator (LiftMaster Model LA412DC). 4. Residential underground swing gate operators (CAME by LiftMaster Model FROG). 5. Residential column-mount swing gate operators (CAME by LiftMaster Model FERNI). 6. Commercial High Traffic DC Swing Gate Operator (LiftMaster Model CSW24VDC). 7. Residential/Light Commercial DC Swing Gate Operator (LiftMaster Model RSW12VDC). 8. Commercial AC swing gate operators (LiftMaster Model CSW200UL Series). a. High-traffic commercial swing gate operators (LiftMaster Model CSW200UL). b. High-traffic commercial swing gate operators (LiftMaster Model CSW200ULST). c. Heavy-duty, one-horsepower commercial swing gate operators (LiftMaster Model CSW200UL1HP). d. High-traffic/high-temperature commercial swing gate operators (LiftMaster Model CSW200ULDM). 9. Light-duty commercial swing gate operators (LiftMaster Model SW490). 10. Commercial High Traffic DC Slide Gate Operator (LiftMaster Model CSL24VDC). 11. Residential/Light Commercial DC Slide Gate Operator (LiftMaster Model RSL12VDC). 12. Residential slide gate operators (CAME by LiftMaster Model BX-243 Series). 13. Commercial AC slide gate operators (LiftMaster Model SL3000UL Series). a. High-traffic commercial slide gate operators (LiftMaster Model SL3000UL). b. Dual-motor/high-temperature commercial slide gate operators (LiftMaster Model SL3000ULDM). c. Heavy-duty, 1HP commercial slide gate operators (LiftMaster Model SL3000UL1HP). 14. Heavy-duty, industrial, gear-driven slide gate operators (LiftMaster Model SL595). 15. Heavy-duty, industrial, gear-driven slide gate operators (LiftMaster Model SL585). 16. Heavy-duty hydraulic slide gate operators (LiftMaster Model HS670 Series). a. Hydraulic slide gate operators (LiftMaster Model HS670GC). b. Hydraulic slide gate operators (LiftMaster Model HS670GI). 17. High-performance commercial DC barrier gate operators with built-in Battery Backup (LiftMaster Model MA Series). 18. High-speed commercial DC barrier gate operators with built-in Battery Backup (LiftMaster Model MAS Series High Speed). 19. Heavy-duty industrial barrier gate operators (LiftMaster Model BG770). 20. Heavy-duty industrial barrier gate operators (LiftMaster Model BG790). 21. Commercial overhead door and gate operators (LiftMaster Model HCT Series). a. Overhead door and gate operators (LiftMaster Model HCT501103-8). b. Overhead door and gate operators (LiftMaster Model HCT501103-10). 02829-1 c. B. 1.2 1.3 1.4 1.5 1.6 Overhead door and gate operators (LiftMaster Model HCT501103-12). Monitored Retro-Reflective Photo Eye (LiftMaster Model CPS-RPEN4GM). RELATED SECTIONS A. Section 02820 - Fences and Gates: Adjoining fences and gates. B. Section 03300 - Cast-in-Place Concrete: Concrete mounting pads. C. Section 11150 - Parking control equipment. D. Division 16 - Requirements for electrical connections. REFERENCES A. National Electrical Manufacturers Association (NEMA): NEMA ICS 6 - Industrial Control and Systems: Enclosures. B. Underwriters Laboratories (UL): UL 325 - Standard for Safety for Door, Drapery, Gate, Louver, and Window Operators and Systems. C. Underwriters Laboratories (UL): UL 991 - Standard for Tests for Safety-Related Controls Employing Solid-State Devices. D. International Organization for Standardization: ISO 9001 - Quality Management Systems. SUBMITTALS A. Submit under provisions of Section 01300. B. Product Data: Equipment list, system description, electrical wiring diagrams for installation, and manufacturer’s data sheets on each product to be used, including: 1. Preparation instructions and recommendations. 2. Storage and handling requirements and recommendations. 3. Installation methods. C. Shop Drawings: Submit shop drawings showing layout, profiles, and product components, including anchorage, edge conditions, and accessories. 1. Operation, installation, and maintenance manuals including wiring diagrams. 2. Risers, layouts, and special wiring diagrams showing any changes to standard drawings. DELIVERY, STORAGE, AND HANDLING A. Deliver, store, and handle materials and products in strict compliance with manufacturer’s instructions and industry standards. B. Store products indoors in manufacturer’s original containers and packaging, with labels clearly identifying product name and manufacturer. Protect from damage. QUALITY ASSURANCE A. Manufacturer Qualifications: ISO 9001 Certified Manufacturer. 02829-2 B. 1.7 Installer Qualifications: Installation performed by factory authorized contractor specifically trained in gate operation systems of the type found within this section. 1. Provide documentation of maintenance and repair service availability for emergency conditions. 2. Provide quarterly maintenance for one year following Substantial Completion of the Project. WARRANTY A. Manufacturer’s Standard Limited Warranty: 1. Warranty Period: 2 years. 2. Warranty Period: 2 years for operator, 10 years for operator framed. 3. Warranty Period: 3 years for residential applications. 4. Warranty Period: 5 years. 5. Warranty Period: 5 years for commercial applications, 7 years for single home applications. PART 2 PRODUCTS 2.1 2.2 MANUFACTURERS A. Acceptable Manufacturer: LiftMaster; 845 Larch Avenue; Elmhurst, IL 60126-1196. ASD. Toll-Free: 800.282.6225. Email: specs@LiftMaster.com. Web: LiftMaster.com. B. Substitutions: Not permitted. C. Requests for substitutions will be considered in accordance with provisions of Section 01600. GATE OPERATORS A. Gate Operators: LiftMaster LA500DC Residential/Light Commercial DC Linear Actuator. 1. LiftMaster LA500DC Single Actuator Arm. a. Full length commercial housing corrosion resistant aluminum. b. Molecular bonded self-lubricating drive screw. 2. LiftMaster LA500CONTDC Control Box for single or master/second application. 3. LiftMaster LA500DCS Second Actuator Arm with junction box and 40-foot (12.2 m) direct burial cable for primary/secondary applications. 4. LiftMaster LA500CONTXLMDC Alternate Control Box for single or master/second applications desiring more room for accessories or two 33 Ah batteries for solar applications. 5. Compliance: UL listed; compliant with UL 325 and CSA C22.2 No. 247 standards. a. Ratings: Class I. b. Ratings: Class II. c. Ratings: Class III. d. Ratings: Class IV. 6. Electrical Power Requirements: 120V AC, single phase 7. Electrical Power Requirements: 240V AC, single phase. 8. Motor: 24V DC, with soft start/stop operation. a. Duty cycle: Continuous. 9. Capacity: 12-foot (3658 mm) gate at 1,200 pounds (554 kg) or 18-foot (5486 mm) gate at 600 pounds (272 kg). 10. Recommended Cycles per Day: 300. 11. Gate Travel Speed: 90-degree opening in 15 to 17 seconds. 12. Warranty: 2 years. 02829-3 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. Wormgear Reduction: Precision machined metal gears contained in lubrication housing. Battery Backup: Power Management system draws 14.8 mA when gate is idle. Provides 500 cycles on Battery Backup with two 7 Ah batteries with remote controls programmed. Standby Time: Provides up to 24 days of standby power in the event of a power loss (excluding accessories). Solar Capable: See daily solar cycle chart. Accessory Electrical Power Requirements: 24V DC 500 mA output, switched and unswitched power. Receiver: Security+ 2.0, holds 50 remote controls, HomeLink compatible a. Transmits 310 MHz, 315 MHz, 390 MHz. Electronic Limits: Maintains accurate limit position throughout travel, even after using the manual release handle. Dual-gate operation capabilities to allow 2 separate gate operators to operate in unison at a single entrance. Standard control box compatible with single or dual gates with no extra parts. Bi-Part Delay: Selectable feature for dual-gate applications. Firmware monitors speed and position of each gate and adjusts speed as necessary to ensure primary gate closes last, avoiding potential damage to the gate. Synchronized Close: Selectable feature for dual-gate applications with curved driveways. Monitors the speed and position of each gate and adjusts speed as necessary to ensure both the gates close at the same time. Only available if two control boxes are used. Programmable Auxiliary Relays: 2 programmable relays with 6 settings each a. Pre-warning or gate-in-motion sounder. b. Switch on/off devices at open or close limits or while gate is in motion. c. Quick-close, anti-tailgate. d. Tamper detection if gate is pushed off Close limit. e. Cycle quantity feedback. Plug-in loop detector inputs with 8 settings. Alarm Reset Button: Instantly resets the built-in safety alarm siren. Fire Department Compliant: Selectable settings allow gate to auto open on power failure or battery depletion. Surge Suppression: Industrial strength on high and low voltage outputs. Emergency Release: Simple-to-use keyed release handle allows gate to be operated manually and maintain limit position once re-engaged. Chassis: Commercial-duty die cast aluminum housing. Operating Temperature Range: -40 degrees F (-40 degrees C) to 140 degrees F (60 degrees C) MyQ Enabled Accessories: a. LiftMaster 828LM Internet Gateway: Allows remote monitoring from Internetenabled computer or smartphone. b. LiftMaster 829LM Garage and Gate Monitor: Allows remote monitoring and operation. c. LiftMaster 823LM Remote Light Switch: Controls light remotely. d. LiftMaster 825LM Remote Light Control: Allows remote monitoring and operation. Accessories: Provide the optional accessories listed below. a. LiftMaster EL25 Private and Multi-Tenant Telephone Entry System. b. LiftMaster KPR2000 Single Entry Access Control Keypad and Proximity Reader. c. LiftMaster LOOPDETLM Plug-in Loop Detector. d. LiftMaster CPS-UN4 Thru-Beam Photo Eyes. e. LiftMaster CPS-RPEN4GM Monitored Retro-Reflective Photo Eye. f. LiftMaster SOLPNL10W12V 10 Watt Solar Panel. 02829-4 g. h. i. j. k. l. m. n. B. LiftMaster SOLPNL20W12V 20 Watt Solar Panel. LiftMaster LA500CONTXLMDC Metal Control Box. LiftMaster MG1300 Maglock. 1,300 lb (590 kg) holding force. LiftMaster G65ME120C5 Sensing Edges. LiftMaster 811LM 1-Button Encrypted DIP Remote Control. LiftMaster 813LM 3-Button Encrypted DIP Remote Control. LiftMaster 892LT Security+ 2.0 Remote. HomeLink compatible. LiftMaster 894LT Security+ 2.0 Remote. HomeLink compatible. Gate Operators: LiftMaster LA400DC Residential DC Linear Actuator. 1. LiftMaster LA400DC Single Actuator Arm. a. Cast aluminum corrosion-resistant body, stainless steel piston. 2. LiftMaster LA400CONTDC Control Box for single or master/second application. 3. LiftMaster LA400DCS Second Actuator Arm with junction box and 40-foot (12.2 m) direct burial cable for primary/secondary applications. 4. Compliance: UL listed; compliant with UL 325 and CSA C22.2 No. 247 standards. a. Ratings: Class I. b. Ratings: Class II. c. Ratings: Class III. d. Ratings: Class IV. 5. Electrical Power Requirements: 120V AC, single phase 6. Motor: 24V DC, with soft start/stop operation. a. Duty cycle: Continuous. 7. Capacity: 16-foot (4877 mm) gate at 550 pounds (249 kg). 8. Recommended Cycles per Day: 100. 9. Gate Travel Speed: 90-degree opening in 15 to 17 seconds. 10. Warranty: 2 years. 11. Wormgear Reduction: Precision machined metal gears contained in lubrication housing. 12. Battery Backup: Power Management system draws 3.7 mA when gate is idle with remote controls programmed. Provides 400 cycles on Battery Backup with two 7 Ah batteries. 13. Standby Time: Provides up to 97 days of standby power in the event of a power loss (excluding accessories). 14. Solar Capable: See daily solar cycle chart. 15. Accessory Electrical Power Requirements: 24V DC 500 mA output, switched and unswitched power. 16. Receiver: Security+ 2.0, holds 50 remote controls, HomeLink compatible a. Transmits 310 MHz, 315 MHz, 390 MHz. 17. Electronic Limits: Maintains accurate limit position throughout travel, even after using the manual release handle. 18. Dual-gate operation capabilities to allow 2 separate gate operators to operate in unison at a single entrance. Standard control box compatible with single or dual gates with no extra parts. 19. Bi-Part Delay: Selectable feature for dual-gate applications. Firmware monitors speed and position of each gate and adjusts speed as necessary to ensure primary gate closes last, avoiding potential damage to the gate. 20. Synchronized Close: Selectable feature for dual-gate applications with curved driveways. Monitors the speed and position of each gate and adjusts speed as necessary to ensure both the gates close at the same time. Only available if two control boxes are used. 21. Plug-in loop detector inputs with 8 settings. 22. Alarm Reset Button: Instantly resets the built-in safety alarm siren. 23. Fire Department Compliant: Selectable settings allow gate to auto open on power failure or battery depletion. 24. Surge Suppression: Industrial strength on high and low voltage outputs. 02829-5 25. 26. 27. 28. 29. C. Emergency Release: Simple-to-use keyed release handle allows gate to be operated manually and maintain limit position once re-engaged. Chassis: Commercial-duty die cast aluminum housing. Operating Temperature Range: -40 degrees F (-40 degrees C) to 140 degrees F (60 degrees C) MyQ Enabled Accessories: a. LiftMaster 828LM Internet Gateway: Allows remote monitoring from Internetenabled computer or smartphone. b. LiftMaster 829LM Garage and Gate Monitor: Allows remote monitoring and operation. c. LiftMaster 823LM Remote Light Switch: Controls light remotely. d. LiftMaster 825LM Remote Light Control: Allows remote monitoring and operation. Accessories: Provide the optional accessories listed below. a. LiftMaster EL25 Private and Multi-tenant Telephone Entry System. b. LiftMaster KPR2000 Single Entry Access Control Keypad and Proximity Reader. c. LiftMaster 50-DSP7LP Low-Power Loop Detector. d. LiftMaster CPS-UN4 Thru-Beam Photo Eyes. e. LiftMaster CPS-RPEN4GM Monitored Retro-Reflective Photo Eye. f. LiftMaster SOLPNL10W12V 10 Watt Solar Panel. g. LiftMaster SOLPNL20W12V 20 Watt Solar Panel. h. LiftMaster MG1300 Maglock. 1,300 lb (590 kg) holding force. i. LiftMaster G65ME120C5 Sensing Edges. j. LiftMaster 811LM 1-Button Encrypted DIP Remote Control. k. LiftMaster 813LM 3-Button Encrypted DIP Remote Control. l. LiftMaster 892LT Security+ 2.0 Remote. HomeLink compatible. m. LiftMaster 894LT Security+ 2.0 Remote. HomeLink compatible. n. LiftMaster K1D8080-1CC Expansion Board. Gate Operators: LiftMaster LA412DC Solar Residential DC Linear Actuator. 1. LiftMaster LA412DC Single Actuator Arm. a. Cast aluminum corrosion-resistant body, stainless steel piston. 2. LiftMaster LA412CONTDC Control Box for single or master/second application. 3. LiftMaster LA412DCS Second Actuator Arm with junction box and 40-foot (12.2 m) direct burial cable for primary/secondary applications. 4. LiftMaster XLSOLARCONTDC Alternate Control Box for single or master/second applications desiring more room for accessories or two 33 Ah batteries for solar applications. 5. Compliance: UL listed; compliant with UL 325 and CSA C22.2 No. 247 standards. a. Ratings: Class I. b. Ratings: Class II. c. Ratings: Class III. d. Ratings: Class IV. 6. Electrical Power Requirements: 120V AC, single phase. 7. Motor: 12V DC, with soft start/stop operation. 8. Capacity: 16-foot (4877 mm) gate at 550 pounds (249 kg). 9. Recommended Cycles per Day: 50. 10. Gate Travel Speed: 90-degree opening in 15 to 17 seconds. 11. Warranty: 2 years. 12. Wormgear Reduction: Precision machined metal gears contained in lubrication housing. 13. Solar Power Management system draws 5.7 mA when gate is idle. Provides 1160 cycles with two 7 Ah batteries. 14. Standby Time: Provides up to 126 days of standby power in the event of no sun or loss of AC power. 02829-6 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. D. Solar Capable: See daily solar cycle chart. Accessory Electrical Power Requirements: 24V DC 500 mA output, switched and unswitched power. Receiver: Security+ 2.0, holds 50 remote controls, HomeLink compatible a. Transmits 310 MHz, 315 MHz, 390 MHz. Electronic Limits: Maintains accurate limit position throughout travel, even after using the manual release handle. Dual-gate operation capabilities to allow 2 separate gate operators to operate in unison at a single entrance. Standard control box compatible with single or dual gates with no extra parts. Bi-Part Delay: Selectable feature for dual-gate applications. Firmware monitors speed and position of each gate and adjusts speed as necessary to ensure primary gate closes last, avoiding potential damage to the gate. Synchronized Close: Selectable feature for dual-gate applications with curved driveways. Monitors the speed and position of each gate and adjusts speed as necessary to ensure both the gates close at the same time. Only available if two control boxes are used. Plug-in loop detector inputs with 8 settings. Alarm Reset Button: Instantly resets the built-in safety alarm siren. Fire Department Compliant: Selectable settings allow gate to auto open on power failure or battery depletion. Surge Suppression: Industrial strength on high and low voltage outputs. Emergency Release: Simple-to-use keyed release handle allows gate to be operated manually and maintain limit position once re-engaged. Chassis: Commercial-duty die cast aluminum housing. Operating Temperature Range: -40 degrees F (-40 degrees C) to 140 degrees F (60 degrees C) MyQ Enabled Accessories: a. LiftMaster 828LM Internet Gateway: Allows remote monitoring from Internetenabled computer or smartphone. b. LiftMaster 829LM Garage and Gate Monitor: Allows remote monitoring and operation. c. LiftMaster 823LM Remote Light Switch: Controls light remotely. d. LiftMaster 825LM Remote Light Control: Allows remote monitoring and operation. Accessories: Provide the optional accessories listed below. a. LiftMaster KPR2000 Single Entry Access Control Keypad and Proximity Reader. b. LiftMaster 50-DSP7LP Low-Power Loop Detector. c. LiftMaster CPS-UN4 Thru-Beam Photo Eyes. d. LiftMaster CPS-RPEN4GM Monitored Retro-Reflective Photo Eye. e. LiftMaster SOLPNL10W12V 10 Watt Solar Panel. f. LiftMaster SOLPNL20W12V 20 Watt Solar Panel. g. LiftMaster XLSOLARCONTDC XL Control Box. h. LiftMaster SGLOCK12V Solenoid Lock.. i. LiftMaster G65ME120C5 Sensing Edges. j. LiftMaster 811LM 1-Button Encrypted DIP Remote Control. k. LiftMaster 813LM 3-Button Encrypted DIP Remote Control. l. LiftMaster 892LT Security+ 2.0 Remote. HomeLink compatible. m. LiftMaster 894LT Security+ 2.0 Remote. HomeLink compatible. n. LiftMaster K1D8080-1CC Expansion Board. Gate Operators: CAME by LiftMaster FROG Residential Underground Swing Gate Operator. 1. Compliance: ETL listed; compliant with UL 325 and CSA C22.2 No. 247 standards. a. Ratings: Class I. b. Ratings: Class II. 02829-7 E. c. Ratings: Class III. d. Ratings: Class IV. 2. Operation: a. Soft stop, precise adjustable speed control. b. Manual disconnect for emergency operation. c. Timer-to-Close automatically closes the gate after preset time. d. Programmable for both single and dual-gate applications. 3. Capacity: 11-1/2 foot (3505 mm) gate at 880 pounds (399 kg) or 6-1/2 foot (1981 mm) gate at 1,770 pounds (802 kg). 4. Warranty: 2 years. 5. Cover: Galvanized steel. 6. In-Ground Casing: Coated steel. 7. Electrical Power Requirements: 120V AC, single phase. 8. Motor Electrical Power Requirements: 24V DC, continuous duty. 9. Accessory Power Output: 24V AC, 2A. 10. Receiver: Security+ 2.0, holds 50 remote controls. 11. Surge Suppression: On high and low voltage inputs. 12. Operator Duty Cycle Rating: 25 cycles per day. 13. Gate Travel Speed: 90-degree opening adjustable in 16 to 45 seconds. 14. Operating Temperature Range: -4 degrees F (-20 degrees C) to 131 degrees F (55 degrees C). 15. Accessories: Provide the optional accessories listed below. a. CAME by LiftMaster DIR10M Thru-Beam Photo Eyes, 32-4/5 foot (9774 mm) sensing distance, NC contact. b. CAME by LiftMaster DIRL Extruded 16-1/2 inch (419 mm) Aluminum Photo Eye Mounting Post with Base. c. CAME by LiftMaster DIRZ Photo Eye Aluminum Alloy Impact Cover. d. LiftMaster LD7LP Low-Power Loop Detector. e. LiftMaster 893MAX 3-Button Remote Control. f. LiftMaster 890MAX 3-Button Mini Remote Control. g. LiftMaster TAC1 Single Tenant Telephone Entry System. h. LiftMaster EL25 Single/Multi-Tenant Telephone Entry System. Gate Operators: CAME by LiftMaster FERNI Residential Column-Mount Gate Operator. 1. Compliance: ETL listed; compliant with UL 325 and CSA C22.2 No. 247 standards. a. Ratings: Class I. b. Ratings: Class II. c. Ratings: Class III. d. Ratings: Class IV. 2. Operation: a. Soft stop, precise adjustable speed control. b. Simple manual disconnect for emergency operation. c. Timer-to-Close automatically closes the gate after preset time. 3. Capacity: 13-foot (3962 mm) gate at 880 pounds (400 kg) or 6-1/2 foot (1981 mm) gate at 1,770 pounds (802 kg). 4. Warranty: 3 years for residential applications. 5. Mounting: Designed to attach to column or fence post, can be mounted at top, middle or bottom of gate. 6. Cover: UV-resistant plastic. 7. Operator Motor Casing: Aluminum. 8. Electrical Power Requirements: 120V AC, single phase. 9. Motor: 24V DC, continuous duty. 10. Accessory Power Output: 24V AC, 2A. 11. Receiver: Security+ 2.0, holds 50 transmitters. 12. Surge Suppression: On high and low voltage inputs. 13. Operator Duty Cycle Rating: 25 cycles per day. 02829-8 14. 15. 16. F. Gate Travel Speed: 90-degree opening adjustable in 12 to 45 seconds. Operating Temperature Range: -4 degrees F (-20 degrees C) to 131 degrees F (55 degrees C). Accessories: Provide the optional accessories listed below. a. CAME by LiftMaster DIR10M Thru-Beam Photo Eyes, 32-4/5 foot (9774 mm) sensing distance, NC contact. b. CAME by LiftMaster DIRL Extruded 16-1/2 inch (419 mm) Aluminum Photo Eye Mounting Post with Base. c. CAME by LiftMaster DIRZ Photo Eye Aluminum Alloy Impact Cover. d. LiftMaster LD7LP Low-Power Loop Detector. e. LiftMaster 893MAX 3-Button Remote Control. f. LiftMaster 890MAX 3-Button Mini Remote Control. g. LiftMaster TAC1 Single Tenant Telephone Entry System. h. LiftMaster EL25 Single/Multi-Tenant Telephone Entry System. Gate Operators: LiftMaster CSW24VDC Commercial High Traffic DC Swing Gate Operator. 1. LiftMaster CSW24VDC Swing Gate Operator. 2. Compliance: UL listed; compliant with UL 325 and CSA C22.2 No. 247 standards. a. Ratings: Class I. b. Ratings: Class II. c. Ratings: Class III. d. Ratings: Class IV. 3. Electrical Power Requirements: 120V AC, single phase 4. Electrical Power Requirements: 240V AC, single phase. 5. Motor: 24V DC, with soft start/stop operation. a. Duty cycle: continuous. 6. Capacity: 12-foot (3658 mm) gate at 1,200 pounds (554 kg) or 18-foot (5486 mm) gate at 600 pounds (272 kg). 7. Recommended Cycles per Day: Continuous duty. 8. Gate Travel Speed: 90-degree opening in 13 to 15 seconds. 9. Warranty: 5 years for commercial applications, 7 years for single-home applications. 10. Wormgear Reduction: 2 commercial oil bath gearboxes with 900:1 wormgear reduction running in synthetic oil bath. 11. Battery Backup: Power Management system draws 14.8 mA when gate is idle with remote controls programmed. Provides 146 cycles on Battery Backup with two 7 Ah batteries or 876 cycles with two 33 Ah batteries. 12. Standby Time: Provides up to 24 days of standby power in the event of a power loss with two 7 Ah batteries or 105 days with two 33 Ah batteries (excluding accessories). 13. Solar Capable: See daily solar cycle chart. 14. Accessory Electrical Power Requirements: 24V DC 500 mA output, switched and unswitched power. 15. Receiver: Security+ 2.0, holds 50 remote controls, HomeLink compatible a. Transmits 310 MHz, 315 MHz, 390 MHz. 16. Electronic Limits: Maintains accurate limit position throughout travel, even after using the manual release handle. 17. Dual-gate operation capabilities to allow 2 separate gate operators to operate in unison at a single entrance. 18. Wireless Dual-Gate Operation: Built-in wireless communication will operate primary and secondary operator without having to run a communication wire. 19. Bi-Part Delay: Selectable feature for dual-gate applications. Firmware monitors speed and position of each gate and adjusts speed as necessary to ensure primary gate closes last, avoiding potential damage to the gate. 20. Synchronized Close: Selectable feature for dual-gate applications with curved driveways. Monitors the speed and position of each gate and adjusts speed as necessary to ensure both the gates close at the same time. 21. Programmable Auxiliary Relays: 2 programmable relays with 6 settings each 02829-9 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. G. a. Pre-warning or gate-in-motion sounder. b. Switch on/off devices at open or close limits or while gate is in motion. c. Quick-close, anti-tailgate. d. Tamper detection if gate is pushed off Close limit. e. Cycle quantity feedback. Plug-in loop detector inputs with 8 settings. Alarm Reset Button: Instantly resets the built-in safety alarm siren. Fire Department Compliant: Selectable settings allow gate to auto open on power failure or battery depletion. Surge Suppression: Industrial strength on high and low voltage outputs. Emergency Release: Simple-to-use keyed release handle allows gate to be operated manually and maintain limit position once re-engaged. Chassis: Constructed with 1/4-inch (6 mm) gold zinc-plated steel for rust prevention. Cover: High-density, UV-resitant polycarbonate two-piece cover. Operating Temperature Range: -40 degrees F (-40 degrees C) to 140 degrees F (60 degrees C) MyQ Enabled Accessories: a. LiftMaster 828LM Internet Gateway: Allows remote monitoring from Internetenabled computer or smartphone. b. LiftMaster 829LM Garage and Gate Monitor: Allows remote monitoring and operation. c. LiftMaster 823LM Remote Light Switch: Controls light remotely. d. LiftMaster 825LM Remote Light Control: Allows remote monitoring and operation. Accessories: Provide the optional accessories listed below. a. LiftMaster EL25 Private and Multi-tenant Telephone Entry System. b. LiftMaster KPR2000 Single Entry Access Control Keypad and Proximity Reader. c. LiftMaster LOOPDETLM Plug-in Loop Detector. d. LiftMaster CPS-UN4 Thru-Beam Photo Eyes. e. LiftMaster CPS-RPEN4GM Monitored Retro-Reflective Photo Eye. f. LiftMaster SOLPNL10W12V 10 Watt Solar Panel. g. LiftMaster SOLPNL20W12V 20 Watt Solar Panel. h. LiftMaster MG1300 Maglock. 1,300 lb (590 kg) holding force. i. LiftMaster G65ME120C5 Sensing Edges. j. LiftMaster 811LM 1-Button Encrypted DIP Remote Control. k. LiftMaster 813LM 3-Button Encrypted DIP Remote Control. l. LiftMaster 892LT Security+ 2.0 Remote. HomeLink compatible. m. LiftMaster 894LT Security+ 2.0 Remote. HomeLink compatible. n. LiftMaster GHTRKITRSW Heater Kit. o. LiftMaster STAR1000 Commercial Access Control Receiver. p. LiftMaster PPWR Passport Receive with Security+ 2.0 Technology. q. LiftMaster IPAC Internet Protocol Access Control. Gate Operators: LiftMaster RSW12VDC Residential/Light Commercial DC Swing Gate Operator. 1. LiftMaster RSW12VDC Swing Gate Operator. 2. Compliance: UL listed; compliant with UL 325 and CSA C22.2 No. 247 standards. a. Ratings: Class I. b. Ratings: Class II. c. Ratings: Class III. d. Ratings: Class IV. 3. Electrical Power Requirements: 120V AC, single phase. 4. Motor: 12V DC, with soft start/stop operation. 5. Capacity: 12-foot (3658 mm) gate at 600 pounds (272 kg) or 16-foot (4900 mm) gate at 400 pounds (181 kg). 02829-10 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. Recommended Cycles per Day: 250. Gate Travel Speed: 90-degree opening in 15 to 17 seconds. Warranty: 3 years. Wormgear Reduction: 2 commercial oil bath gearboxes with 30:1 wormgear reduction running in synthetic oil bath. Battery Backup: Power Management system draws 5.7 mA when gate is idle with remote controls programmed. Provides 354 cycles on Battery Backup with two 7 Ah batteries. Standby Time: Provides up to 126 days of standby power in the event of a power loss (excluding accessories). Solar Capable: See daily solar cycle chart. Accessory Electrical Power Requirements: 24V DC 500 mA output, switched and unswitched power. Receiver: Security+ 2.0, holds 50 remote controls, HomeLink compatible a. Transmits 310 MHz, 315 MHz, 390 MHz. Electronic Limits: Maintains accurate limit position throughout travel, even after using the manual release handle. Dual-gate operation capabilities to allow 2 separate gate operators to operate in unison at a single entrance. Bi-Part Delay: Selectable feature for dual-gate applications. Firmware monitors speed and position of each gate and adjusts speed as necessary to ensure primary gate closes last, avoiding potential damage to the gate. Synchronized Close: Selectable feature for dual-gate applications with curved driveways. Monitors the speed and position of each gate and adjusts speed as necessary to ensure both the gates close at the same time. Programmable Auxiliary Relays: 2 programmable relays with 6 settings each a. Pre-warning or gate-in-motion sounder. b. Switch on/off devices at open or close limits or while gate is in motion. c. Quick-close, anti-tailgate. d. Tamper detection if gate is pushed off Close limit. e. Cycle quantity feedback. Plug-in loop detector inputs with 8 settings. Alarm Reset Button: Instantly resets the built-in safety alarm siren. Fire Department Compliant: Selectable settings allow gate to auto open on power failure or battery depletion. Surge Suppression: Industrial strength on high and low voltage outputs. Emergency Release: Simple-to-use keyed release handle allows gate to be operated manually and maintain limit position once re-engaged. Chassis: Constructed with 1/4-inch (6 mm) gold zinc-plated steel for rust prevention Cover: High-density, UV-resistant polyethylene cover with stainless steel access door. Operating Temperature Range: -40 degrees F (-40 degrees C) to 140 degrees F (60 degrees C) MyQ Enabled Accessories: a. LiftMaster 828LM Internet Gateway: Allows remote monitoring from Internetenabled computer or smartphone. b. LiftMaster 829LM Garage and Gate Monitor: Allows remote monitoring and operation. LiftMaster 825LM Remote Light Control: Allows remote monitoring and operation. Accessories: Provide the optional accessories listed below. a. LiftMaster EL25 Private and Multi-tenant Telephone Entry System. b. LiftMaster KPR2000 Single Entry Access Control Keypad and Proximity Reader. c. LiftMaster 50-DSP7LP Low-Power Loop Detector. d. LiftMaster CPS-UN4 Thru-Beam Photo Eyes. 02829-11 e. f. g. h. i. j. k. l. m. n. o. p. H. LiftMaster CPS-RPEN4GM Monitored Retro-Reflective Photo Eye. LiftMaster SOLPNL10W12V 10 Watt Solar Panel. LiftMaster SOLPNL20W12V 20 Watt Solar Panel. LiftMaster MG1300 Maglock. 1,300 lb (590 kg) holding force. LiftMaster G65ME120C5 Sensing Edges. LiftMaster 811LM 1-Button Encrypted DIP Remote Control. LiftMaster 813LM 3-Button Encrypted DIP Remote Control. LiftMaster 892LT Security+ 2.0 Remote. HomeLink compatible. LiftMaster 894LT Security+ 2.0 Remote. HomeLink compatible. LiftMaster GHTRKITRSW Heater Kit. LiftMaster STAR1000 Commercial Access Control Receiver. LiftMaster PPWR Passport Receiver with Security+ 2.0 Technology. Gate Operators: LiftMaster CSW200UL Series Commercial Swing Gate Operators. 1. LiftMaster CSW200UL Commercial Swing Gate Operator for high-traffic areas. a. Cover: 1/4-inch (6 mm) thick, unbreakable polyethylene cover. b. Recommended Cycles per Hour: 75. 2. LiftMaster CSW200ULST Commercial Swing Gate Operator for high-traffic areas. a. Cover: Heavy-duty, 16-gauge stainless steel cover finished with an embossed architectural design. b. Recommended Cycles per Hour: 75. 3. LiftMaster CSW200UL1HP Commercial Swing Gate Operator with 1 HP capacity for heavy-duty applications. a. Description: Two 1/2 HP motors and a heavy-duty, 900:1 double transmission; designed for large, heavy wrought-iron gates. 250 pounds (113.4 kg) of pulling torque. b. Recommended Cycles per Hour: 60. 4. LiftMaster CSW200ULDM Commercial Swing Gate Operator for high-traffic/hightemperature application. a. Description: Patented dual-motor drive system designed for superior performance in hot weather climates such as desert environments. Engineered to perform without overheating; one motor opens gate and other closes it. b. Recommended Cycles per Hour: Continuous. 5. Compliance: ETL listed; compliant with UL 325 and CSA C22.2 No. 247 standards. a. Ratings: Class I. b. Ratings: Class II. c. Ratings: Class III. d. Ratings: Class IV. e. OmniControl board provides performance meeting or exceeding UL 325 and UL 991 specifications. 6. Operation: a. Soft stop operation. b. Intelligent master/second; precise, synchronized movement and communication between 2 gate operators. c. Plug-in Loop Detectors: Programmed inputs for shadow, interrupt and exit. d. Operator arms designed not to cross. 7. Warranty: 5 years for commercial applications, 7 years for single-home applications. 8. Electrical Power Requirements: 110V, single phase. 9. Wormgear Reduction: 2 commercial oil bath gearboxes with 900:1 wormgear reduction. 10. Duty Cycle: Continuous. 11. Receiver: Security+ 2.0, holds 50 remote controls, HomeLink compatible. 12. Gate Traveling Speed: 90-degree opening in 13 to 15 seconds. 13. Chassis: Constructed with 1/4-inch (6 mm) sanded, welded and gold zinc-plated sheet metal. 14. Finishing: Metal parts are gold zinc-plated for rustproof protection. 02829-12 15. 16. 17. 18. 19. 20. 21. I. Covers: High-density UV-resistant polyethylene plastic. Surge/Lightning Protection: Protects against lightning strikes at a 50-foot (15.2 m) radius. Reversing Sensors: Detect obstructions or increased loads. Reverse gate when closing or stop/reverse the gate when opening. Emergency Release: Handle allows gate to be operated manually and maintain limit position once re-engaged. Alarm Reset Button: Instantly resets the built-in safety alarm siren. Operating Temperature Range: -40 degrees F (-40 degrees C) to 140 degrees F (60 degrees C). Accessories: Provide the optional accessories listed below. a. LiftMaster DC2000 Power Backup; provides uninterrupted access during a power outage. b. LiftMaster EL2000 Commercial and Gated Community Telephone Entry System. c. LiftMaster TAC1 Single Tenant Telephone Entry System. d. LiftMaster EL25 Single/Multi-Tenant Telephone Entry System. e. LiftMaster AELD Plug-in Loop Detector. f. LiftMaster CPS UN4 Thru-Beam Photo Eyes. g. LiftMaster G65 MGR20 Sensing Edges. h. LiftMaster G6518 Heater Kit. i. LiftMaster MPEL Post Mount Plate. j. LiftMaster Power Hinges. k. LiftMaster Security+ 2.0 Remote Controls. l. LiftMaster advanced traffic management quick-close option. Gate Operators: LiftMaster SW490 Commercial Swing Gate Operator. 1. Compliance: UL 325 listed, UL 991 and CSA C22.2 No. 247 standards. a. Ratings: Class I. b. Ratings: Class II. c. Ratings: Class III. d. Ratings: Class IV. 2. Operator Speed: 90-degree swing in 12 seconds. 3. Electrical Power Requirements: 115/230V AC, single phase, 60 Hz. 4. Electrical Power Requirements: 208/330/460/575V AC, 3-phase, 60 Hz. 5. Capacity: Supports gate lengths up to 12 feet (3658 mm) at 1,800 pounds (816 kg) or 22 feet (6706 mm) at 1,000 pounds (453 kg). 6. Warranty: 2 years. 7. Cycles per Hour: 10. 8. Accessory Power: One, 24V AC. 9. Gear Reduction: 30:1 wormgear in oil. 10. Motor: 1 HP, high-starting torque. 11. Metal Frame: Pre-galvanized steel. 12. Enclosure: Weather-resistant 14-gauge powder-coated, pre-galvanized steel. 13. Built-in Receiver: Single remote control solution for gate access, extra access points. 14. Inherent Obstruction Sensing: Internal obstruction sensing system offers a single force adjustment for both the open and closed directions. If gate strikes obstruction, a closing gate will reverse to open and an opening gate will reverse to close. 15. External Obstruction Sensing: Input connections are provided for external contact and non-contact sensors, such as photo eyes and edge devices. 16. Advanced Dual-Gate Operation: 2-wire system allows operation of 2 separate gate operators in unison at single entrance; accessories can connect to either operator. 17. Sequenced Access Management: Capable of sequentially controlling the operator in tandem with a barrier gate. 18. Digital Logic Control: Supports long-distance control wiring runs of over 1,000 feet (305 m). 02829-13 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. J. LED Indicators: Operator input, status and diagnostic LEDs. Control Inputs: Control inputs allow the connection of optional external devices like loop detectors, telephone entry systems, access control systems and radio receivers. Warning Device: UL 325 compliant entrapment warning alarm can be set for preoperation warning. Provides 3-second warning prior to and during gate movement. Loop Detector Inputs: A range of inputs are available to support exit, shadow and interrupt loop detectors. Timer-to-Close: Adjustable timer can be set from 1 to 180 seconds. The unit will automatically reset upon receiving any additional open commands. Maximum Run Timer: Protects against damage to the gate and operator by limiting the unit’s run time to 120 seconds. Maglock Control: A dedicated control relay is provided to activate and deactivate an optional magnetic lock for securing the gate. Limit Settings: Driven limit cams are fully adjustable. Surge and Spike Protection: Circuitry designed to provide protection from external spikes or surges. Manual Disconnect: Ensures that manual operation is possible during emergencies and maintenance work. Removable Access Control Panel: Removable access door incorporated into design. Accessories: Provide the optional accessories listed below. a. Self-regulating heater, factory installed. b. Auxiliary contact blocks. c. Auxiliary limit switches. d. Remote antenna mounting kit. e. Quick-release manual disconnect system. Gate Operators: LiftMaster CSL24VDC Commercial High Traffic DC Slide Gate Operator. 1. LiftMaster CSL24VDC Slide Gate Operator. 2. Compliance: UL listed; compliant with UL 325 and CSA C22.2 No. 247 standards. a. Ratings: Class I. b. Ratings: Class II. c. Ratings: Class III. d. Ratings: Class IV. 3. Electrical Power Requirements: 120V AC, single phase 4. Electrical Power Requirements: 240V AC, single phase. 5. Motor: 24V DC, with soft start/stop operation. a. Duty cycle: Continuous. 6. Capacity: 50-foot (15200 mm) gate at 1,500 pounds (680 kg). 7. Recommended Cycles per Day: Continuous duty. 8. Gate Travel Speed: 12 inches (304 mm) per second. 9. Warranty: 5 years for commercial applications, 7 years for single-home applications. 10. Wormgear Reduction: Commercial oil bath gearbox with 30:1 wormgear reduction running in synthetic oil bath. 11. Battery Backup: Power Management system draws 14.8 mA when gate is idle with remote controls programmed. Provides 208 cycles on Battery Backup with two 7 Ah batteries or 1179 cycles with two 33 Ah batteries. 12. Standby Time: Provides up to 24 days of standby power in the event of a power loss with two 7 Ah batteries or 105 days with two 33 Ah batteries (excluding accessories). 13. Solar Capable: See daily solar cycle chart. 14. Accessory Electrical Power Requirements: 24V DC 500 mA output, switched and unswitched power. 15. Receiver: Security+ 2.0, holds 50 remote controls, HomeLink compatible a. Transmits 310 MHz, 315 MHz, 390 MHz. 16. Electronic Limits: Maintains accurate limit position throughout travel, even after using the manual disconnect. 02829-14 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. K. Dual-gate operation capabilities to allow 2 separate gate operators to operate in unison at a single entrance. Wireless Dual-Gate Operation: Built-in wireless communication will operate primary and secondary operator without having to run a communication wire. Synchronized Close: Selectable feature for dual-gate applications. Monitors the speed and position of each gate and adjusts speed as necessary to ensure both the gates close at the same time. Programmable Auxiliary Relays: 2 programmable relays with 6 settings each. a. Pre-warning or gate-in-motion sounder. b. Switch on/off devices at open or close limits or while gate is in motion. c. Quick-close, anti-tailgate. d. Tamper detection if gate is pushed off Close limit. e. Cycle quantity feedback. Plug-in loop detector inputs with 8 settings. Alarm Reset Button: Instantly resets the built-in safety alarm siren. Fire Department Compliant: Selectable settings allow gate to auto open on power failure or battery depletion. Surge Suppression: Industrial strength on high and low voltage outputs. Keyed Manual Disconnect: Simple-to-use disconnect allows gate to be operated manually and maintain limit position once re-engaged. Chassis: Constructed with 1/4-inch (6 mm) gold zinc-plated steel for rust prevention. Cover: High-density, UV-resistant polycarbonate two-piece cover. Operating Temperature Range: -40 degrees F (-40 degrees C) to 140 degrees F (60 degrees C) MyQ Enabled Accessories: a. LiftMaster 828LM Internet Gateway: Allows remote monitoring from Internetenabled computer or smartphone. b. LiftMaster 829LM Garage and Gate Monitor: Allows remote monitoring and operation. c. LiftMaster 823LM Remote Light Switch: Controls light remotely. d. LiftMaster 825LM Remote Light Control: Allows remote monitoring and operation. Accessories: Provide the optional accessories listed below. a. LiftMaster EL25 Private and Multi-tenant Telephone Entry System. b. LiftMaster KPR2000 Single Entry Access Control Keypad and Proximity Reader. c. LiftMaster LOOPDETLM Plug-in Loop Detector. d. LiftMaster CPS-UN4 Thru-Beam Photo Eyes. e. LiftMaster CPS-RPEN4GM Monitored Retro-Reflective Photo Eye. f. LiftMaster SOLPNL10W12V 10 Watt Solar Panel. g. LiftMaster SOLPNL20W12V 20 Watt Solar Panel. h. LiftMaster G65ME120C5 Sensing Edges. i. LiftMaster 811LM 1-Button Encrypted DIP Remote Control. j. LiftMaster 813LM 3-Button Encrypted DIP Remote Control. k. LiftMaster 892LT Security+ 2.0 Remote. HomeLink compatible. l. LiftMaster 894LT Security+ 2.0 Remote. HomeLink compatible. m. LiftMaster GHTRKITCSL Heater Kit. n. LiftMaster STAR1000 Commercial Access Control Receiver. o. LiftMaster PPWR Passport Receiver with Security+ 2.0 Technology. p. LiftMaster IPAC Internet Protocol Access Control. Gate Operators: LiftMaster RSL12VDC Residential/Light Commercial DC Slide Gate Operator. 1. LiftMaster RSL12VDC Slide Gate Operator. 2. Compliance: UL listed; compliant with UL 325 and CSA C22.2 No. 247 standards. a. Ratings: Class I. 02829-15 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. b. Ratings: Class II. c. Ratings: Class III. d. Ratings: Class IV. Electrical Power Requirements: 120V AC, single phase Motor: 12V DC, with soft start/stop operation. Capacity: 25-foot (7600 mm) gate at 800 pounds (363 kg). Recommended Cycles per Day: 120. Gate Travel Speed: 10 inches (254 mm) per second. Warranty: 3 years. Wormgear Reduction: 10:1 wormgrear reduction runningin synthetic oil bath. Battery Backup: Power Management system draws 5.7 mA when gate is idle with remote controls programmed. Provides 281 cycles on Battery Backup with two 7 Ah batteries. Standby Time: Provides up to 126 days of standby power in the event of a power loss (excluding accessories). Solar Capable: See daily solar cycle chart. Accessory Electrical Power Requirements: 24V DC 500 mA output, switched and unswitched power. Receiver: Security+ 2.0, holds 50 remote controls, HomeLink compatible a. Transmits 310 MHz, 315 MHz, 390 MHz. Electronic Limits: Maintains accurate limit position throughout travel, even after using the manual disconnect. Dual-gate operation capabilities to allow 2 separate gate operators to operate in unison at a single entrance. Synchronized Close: Selectable feature for dual-gate applications. Monitors the speed and position of each gate and adjusts speed as necessary to ensure both the gates close at the same time. Programmable Auxiliary Relays: 2 programmable relays with 6 settings each. a. Pre-warning or gate-in-motion sounder. b. Switch on/off devices at open or close limits or while gate is in motion. c. Quick-close, anti-tailgate. d. Tamper detection if gate is pushed off Close limit. e. Cycle quantity feedback. Plug-in loop detector inputs with 8 settings. Alarm Reset Button: Instantly resets the built-in safety alarm siren. Fire Department Compliant: Selectable settings allow gate to auto open on power failure or battery depletion. Surge Suppression: Industrial strength on high and low voltage outputs. Manual Disconnect: Simple-to-use disconnect allows gate to be operated manually and maintain limit position once re-engaged. Chassis: Constructed with 1/4-inch (6 mm) gold zinc-placed steel for rust prevention. Cover: High-density, UV-resistant polyethylene cover. Operating Temperature Range: -40 degrees F (-40 degrees C) to 140 degrees F (60 degrees C) MyQ Enabled Accessories: a. LiftMaster 828LM Internet Gateway: Allows remote monitoring from Internetenabled computer or smartphone. b. LiftMaster 829LM Garage and Gate Monitor: Allows remote monitoring and operation. c. LiftMaster 823LM Remote Light Switch: Controls light remotely. d. LiftMaster 825LM Remote Light Control: Allows remote monitoring and operation. Accessories: Provide the optional accessories listed below. a. LiftMaster EL25 Private and Multi-tenant Telephone Entry System. b. LiftMaster KPR2000 Single Entry Access Control Keypad and Proximity Reader. 02829-16 c. d. e. f. g. h. i. j. k. l. m. n. o. L. LiftMaster 50-DSP7LP Low-Power Loop Detector. LiftMaster CPS-UN4 Thru-Beam Photo Eyes. LiftMaster CPS-RPEN4GM Monitored Retro-Reflective Photo Eye. LiftMaster SOLPNL10W12V 10 Watt Solar Panel. LiftMaster SOLPNL20W12V 20 Watt Solar Panel. LiftMaster G65ME120C5 Sensing Edges. LiftMaster 811LM 1-Button Encrypted DIP Remote Control. LiftMaster 813LM 3-Button Encrypted DIP Remote Control. LiftMaster 892LT Security+ 2.0 Remote. HomeLink compatible. LiftMaster 894LT Security+ 2.0 Remote. HomeLink compatible. LiftMaster GHTRKITRSL Heater Kit. LiftMaster STAR1000 Commercial Access Control Receiver. LiftMaster PPWR Passport Receiver with Security+ 2.0 Technology. Gate Operators: CAME by LiftMaster BX-243 Series Residential Slide Gate Operators. 1. CAME by LiftMaster BX-243C Chain Drive Operator, 28-foot (8534 mm) zinc steel coil chain, lubrication not required. 2. CAME by LiftMaster BX-243R Rack and Pinion Drive Operators, rack in polyamidecovered steel sections. 3. CAME by LiftMaster BX-243R Rack and Pinion Drive Operators, rack in steel sections. 4. Compliance: ETL listed; compliant with UL 325 and CSA C22.2 No. 247 standards. a. Ratings: Class I. b. Ratings: Class II. c. Ratings: Class III. d. Ratings: Class IV. 5. Operation: a. Soft stop. b. Partial opening feature for motorcycle access. c. Simple manual disconnect for emergency operation. d. Timer-to-Close automatically closes the gate after preset time. 6. Capacity: Up to a 25-foot (7620 mm) gate at 660 pounds (300 kg). 7. Warranty: 3 years for residential applications. 8. Operator Chassis: Cast aluminum. 9. Pan Mounting Plate: Galvanized steel. 10. Electrical Power Requirements: 120V AC, single phase. 11. Motor Electrical Power Requirements: 24V DC, continuous duty. 12. Accessory Power Output: 24V AC, 1.5A. 13. Receiver: Security+ 2.0, holds 50 remote controls. 14. Surge Suppression: On high and low voltage inputs. 15. Operator Duty Cycle Rating: 25 cycles per day. 16. Gate Travel Speed: 7-1/2 inches (190 mm) per second. 17. Operating Temperature Range: -4 degrees F (-20 degrees C) to 131 degrees F (55 degrees C). 18. Accessories: Provide the optional accessories listed below. a. CAME by LiftMaster DIR10M Thru-Beam Photo Eyes, 32-4/5 foot (9774 mm) sensing distance, NC contact. b. CAME by LiftMaster DIRL Extruded 16-1/2 inch (419 mm) Aluminum Photo Eye Mounting Post with Base. c. CAME by LiftMaster DIRZ Photo Eye Aluminum Alloy Impact Cover. d. LiftMaster LD7LP Low-Power Loop Detector. e. LiftMaster 893MAX 3- Button Remote Control. f. LiftMaster 890MAX 3- Button Mini Remote Control. g. LiftMaster TAC1 Single Tenant Telephone Entry System. h. LiftMaster EL25 Single/Multi-Tenant Telephone Entry System. 02829-17 M. Gate Operators: LiftMaster SL3000UL Series Commercial Slide Gate Operators. 1. LiftMaster SL3000UL Commercial Slide Gate Operator for high-traffic applications. a. Maximum Gate Weight (Pounds): 1,000 (305 m). b. Maximum Gate Length (Feet): 37 (11.2 m). c. Recommended Cycles/Hour: Continuous. 2. LiftMaster SL3000ULDM Commercial Slide Gate Operator with dual motor for hightraffic/high-demand applications. a. Description: Features patented dual-motor drive system for superior performance in hot weather climates such as desert environments. Engineered for high-traffic commercial applications, the unit is designed to operate without overheating, using one motor to open the gate and the other to close it. b. Maximum Gate Weight (Pounds): 800 (363 kg). c. Maximum Gate Length (Feet): 37 (11.2 m). d. Recommended Cycles/Hour: Continuous. 3. LiftMaster SL3000UL1HP Commercial Slide Gate Operator with 1 HP capacity for heavy-duty applications. a. Description: Two 1/2 HP motors and a heavy-duty transmission, designer for large, heavy wrought-iron gates. b. Pulling Torque: 210 pounds (95.2 kg) of pulling torque. c. Maximum Gate Weight (Pounds): 2,000 (907.2 kg). d. Maximum Gate Length (Feet): 37 (11.3 m). e. Recommended Cycles/Hour: 35. 4. Warranty: 5 years for commercial applications, 7 years for single-home applications. 5. Compliance: ETL listed; compliant with UL 325 and CSA C22.2 No. 247 standards. a. Ratings: Class I. b. Ratings: Class II. c. Ratings: Class III. d. Ratings: Class IV. e. OmniControl board provides performance meeting or exceeding UL 325 and UL 991 specifications. 6. Operation: a. Electronic Motor Disconnect: Prevents activation of the motor while under manual operation. b. Intelligent master/second; precise, synchronized movement and communication between 2 gate operators. c. Plug-in Loop Detectors: Programmed inputs for shadow, interrupt and exit. 7. Electrical Power Requirements: 110V, single phase. 8. Wormgear Reduction: 2 commercial oil bath gearboxes, 30:1 wormgear reduction. 9. Receiver: Security+ 2.0, holds 50 remote controls, HomeLink compatible. 10. Gate Traveling Speed: 12 inches (305 mm) per second. 11. Chassis: Constructed with 1/4-inch (6 mm) sanded, welded and gold zinc-plated sheet metal. 12. Finishing: Metal parts are gold zinc-plated for rustproof protection. 13. Covers: High-density UV-resistant polyethylene plastic. 14. Surge/Lightning Protection: Protects against lightning strikes at a 50-foot (15.2 m) radius. 15. Reversing Sensors: Detect obstructions or increased loads. Reverse gate when closing or stop/reverse the gate when opening. 16. Manual disconnect allows gate to be operated manually and maintain limit position once re-engaged. 17. Operating Temperature Range: -40 degrees F (-40 degrees C) to 140 degrees F (60 degrees C). 18. Accessories: Provide the optional accessories listed below. a. LiftMaster DC2000 Power Backup: Provides uninterrupted access during a power outage. 02829-18 b. c. d. e. f. g. h. i. j. k. N. LiftMaster EL2000 Commercial and Gated Community Telephone Entry System. LiftMaster TAC1 Single Tenant Telephone Entry System. LiftMaster EL25 Single/Multi-Tenant Telephone Entry System. LiftMaster AELD Plug-in Loop Detector. LiftMaster CPS UN4 Thru-Beam Photo Eyes. LiftMaster G65 MGR20 Sensing Edges. LiftMaster G6518 Heater Kit. LiftMaster MPEL Post Mount Plate. LiftMaster Power Wheels, 4-inch (101 mm) or 6-inch (152 mm) heat-treated wheels. LiftMaster Security+ 2.0 Remote Controls. Gate Operators: LiftMaster SL595 Industrial Gear-Driven Slide Gate Operator. 1. Compliance: UL 325 listed, UL 991 and CSA C22.2 No. 247 standards. a. Ratings: Class I. b. Ratings: Class II. c. Ratings: Class III. d. Ratings: Class IV. 2. Warranty: 2 years. 3. Operator Speed: 12 inches (305 mm) per second. 4. Electrical Power Requirements: 115/208/230V AC, single phase, 60 Hz. 5. Electrical Power Requirements: 208/230/460/575V AC, 3-phase, 60 Hz. 6. Accessory Electrical Power Requirements: 24V AC. 7. Gear Reduction: 20:1 wormgear reducer in synthetic oil bath. 8. Motor: 1 HP, continuous duty. a. Capacity: Supports gate lengths up to 70 feet (21.5 m) and gate weights up to 1,700 pounds(771 kg). b. Recommended Cycles per Hour: 25. 9. Motor: 1-1/2 HP, continuous duty (115/230V, single phase only). a. Capacity: Supports gate lengths up to 80 feet (24.4 m) and gate weights up to 2,100 pounds (953 kg). b. Recommended Cycles per Hour: 25. 10. Motor: 2 HP, continuous duty (208/230/460/575V AC, 3-phase only). a. Capacity: Supports gate lengths up to 90 feet (27.4 m) and gate weights up to 2,500 pounds (1134 kg). b. Recommended Cycles per Hour: 25. 11. Metal Frame: 7-gauge pre-galvanized steel. 12. Chassis: Powder-coated galvanized steel. 13. Enclosure: NEMA 3R enclosure; oil-tight, weatherproof NEMA 3R cabinet lockable. 14. Chain: #50 nickel-plated, 25 feet (7620 mm) supplied with each unit. 15. Gearbox: All-weather. 16. Built-in Receiver: Single remote control solution for gate access, extra access points. 17. Integrated 3-Button Control Station: 3-button control station incorporated into the outside of the control box. 18. Inherent Obstruction Sensing: Offers separate force adjustments for both the open and closed directions. If the gate strikes an obstruction, a closing gate will reverse to open and an opening gate will stop. 19. External Obstruction Sensing: Input connections are provided for external contact and non-contact sensors, such as photo eyes and edge devices. 20. Advanced Dual-Gate Operation: 2-wire system allows the operation of 2 separate gate operators in unison at a single entrance; accessories connect to either operator. 21. Sequenced Access Management: Capable of sequentially controlling the operator in tandem with a barrier gate. 22. LED Indicators: Operator input, status and diagnostic LEDs. 02829-19 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. O. Control Inputs: Allow the connection of optional external devices like loop detectors, access control systems and radio receivers. Digital Logic Control: Supports long-distance control wiring runs of over 1,000 feet (305 m). Surge and Spike Protection: Circuitry designed to provide protection from external spikes or surges. Warning Device: UL 325 compliant entrapment warning alarm has ability to be set for pre-operation warning; provides 3-second warning prior to and during gate movement. Loop Detector Inputs: Compatible with exit, shadow and interrupt loop detectors. External Alarm Reset Button: Allows for quick reset of the gate operator when the alarm has been activated. Timer-to-Close: Adjustable timer can be set from 1 to 180 seconds. Unit automatically resets upon receiving any additional open commands. Maximum Run Timer: Protects against damage to the gate and operator by limiting the unit’s run time to 120 seconds. External Manual Disconnect: Allows gate to be opened in the event of a power loss without removing the operator cover. Mechanical Braking: The mechanical braking system adds substantial gate position control at all points in travel. The solenoid-actuated brake system also prevents the gate from being back-driven. Limit Settings: Driven limit nut switches are fully adjustable. Lockable Hinged Access Door: Weather-resistant, lockable, hinged design allows access to the unit’s electronics for installation or servicing needs. Accessories: Provide the optional accessories listed below. a. LiftMaster G70-416 7NH Plug-in Loop Detectors. b. LiftMaster Thermostatically Controlled Fin-Type Heater. c. LiftMaster Auxiliary Contact Blocks. d. LiftMaster Remote Antenna Mounting Kit. e. LiftMaster EL2000 Commercial and Gated Community Telephone Entry System. f. LiftMaster STAR1000 Commercial Access Control Receiver. g. LiftMaster 811LM 1-Button Encrypted DIP Remote Control. h. LiftMaster 813LM 3-Button Encrypted DIP Remote Control. i. LiftMaster PPWR Passport Receiver with Security+ 2.0 Technology. 1) LiftMaster PPV1 Passport 1-Button Remote. 2) LiftMaster PPK1 Passport 1-Button Mini Remote. j. LiftMaster KPR2000 Single Access Control Keypad and Proximity Reader. k. LiftMaster 361LM 1-Button Remote Control. l. LiftMaster 363LM 3-Button Remote Control. Gate Operators: LiftMaster SL585 Industrial Gear-Driven Slide Gate Operator. 1. Compliance: UL 325 listed, UL 991 and CSA C22.2 No. 247 standards. a. Ratings: Class I. b. Ratings: Class II. c. Ratings: Class III. d. Ratings: Class IV. 2. Warranty: 2 years. 3. Operator Speed: 11 inches (279.4 mm) per second. 4. Electrical Power Requirements: 115/208/230V AC, single phase, 60 Hz. 5. Electrical Power Requirements: 208/230/460/575V AC, 3-phase, 60 Hz. 6. Accessory Electrical Power Requirements: 24V AC. 7. Gear Reduction: 20:1 wormgear reducer in synthetic oil bath. 8. Motor: 1/2 HP, continuous duty. a. Capacity: Supports gate lengths up to 45 feet (13 m) and gate weights up to 1,000 pounds (454 kg). 02829-20 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. b. Recommended Cycles per Hour: 20. Motor: 1 HP, continuous duty. a. Capacity: Supports gate lengths up to 70 feet (21 m) and gate weights up to 1,600 pounds (725 kg). b. Recommended Cycles per Hour: 20. Motor: 1-1/2 HP, continuous duty (115V/230V, single phase only). a. Capacity: Supports gate lengths up to 75 feet (23 m) and gate weights up to 1,900 pounds (862 kg). b. Recommended Cycles per Hour: 20. Metal Frame: 7-gauge pre-galvanized steel. Chassis: Powder-coated galvanized steel. Enclosure: Weather-resistant, lockable, 16-gauge steel cover. Chain: #50 nickel-plated, 25 feet (7620 mm) supplied with each unit. Gearbox: All-weather. Built-in Receiver: Single remote control solution for gate access, extra access points. Integrated 3-Button Control Station: 3-button control station incorporated into the outside of the control box. Inherent Obstruction Sensing: Offers separate force adjustments for both the open and closed directions. If the gate strikes an obstruction, a closing gate will reverse to open and an opening gate will stop. External Obstruction Sensing: Input connections are provided for external contact and non-contact sensors, such as photo eyes and edge devices. Advanced Dual-Gate Operation: 2-wire system allows the operation of 2 separate gate operators in unison at a single entrance; accessories connect to either operator. Sequenced Access Management: Capable of sequentially controlling the operator in tandem with a barrier gate. LED Indicators: Operator input, status and diagnostic LEDs. Control Inputs: Allow the connection of optional external devices like loop detectors, access control systems and radio receivers. Digital Logic Control: Supports long-distance control wiring runs of over 1,000 feet (305 m). Surge and Spike Protection: Circuitry designed to provide protection from external spikes or surges. Warning Device: UL 325 compliant entrapment warning alarm has ability to be set for pre-operation warning; provides 3-second warning prior to and during gate movement. Loop Detector Inputs: Compatible with exit, shadow and interrupt loop detectors. External Alarm Reset Button: Allows for quick reset of the gate operator when the alarm has been activated. Timer-to-Close: Adjustable timer can be set from 1 to 180 seconds. Unit automatically resets upon receiving any additional open commands. Maximum Run Timer: Protects against damage to the gate and operator by limiting the unit’s run time to 120 seconds. External Manual Disconnect: Allows gate to be opened in the event of a power loss without removing the operator cover. Mechanical Braking: The mechanical braking system adds substantial gate position control at all points in travel. The solenoid-actuated brake system also prevents the gate from being back-driven. Limit Settings: Driven limit nut switches are fully adjustable. Lockable Hinged Access Door: Weather-resistant, lockable, hinged design allows access to the unit’s electronics for installation or servicing needs. Accessories: Provide the optional accessories listed below. a. LiftMaster G70-416 7NH Plug-in Loop Detectors. b. LiftMaster Thermostatically Controlled Fin-Type Heater. c. LiftMaster Auxiliary Contact Blocks. d. LiftMaster Remote Antenna Mounting Kit. 02829-21 e. f. g. h. i. j. k. l. P. LiftMaster EL2000 Commercial and Gated Community Telephone Entry System. LiftMaster STAR1000 Commercial Access Control Receiver. LiftMaster 811LM 1-Button Encrypted DIP Remote Control. LiftMaster 813LM 3-Button Encrypted DIP Remote Control. LiftMaster PPWR Passport Receiver with Security+ 2.0 Technology. 1) LiftMaster PPV1 Passport 1-Button Remote. 2) LiftMaster PPK1 Passport 1-Button Mini Remote. LiftMaster KPR2000 Single Access Control Keypad and Proximity Reader. LiftMaster 361LM 1-Button Remote Control. LiftMaster 363LM 3-Button Remote Control. Gate Operators: LiftMaster HS670 Series Heavy-Duty Hydraulic Slide Gate Operators. 1. LiftMaster GC Hydraulic Slide Gate Operators. a. Compliance: UL 325 listed, UL 991 and CSA C22.2 No. 247. 1) Ratings: Class I. 2) Ratings: Class II. 3) Ratings: Class III. 4) Ratings: Class IV. b. Operator Speed: 12 inches (305 mm) per second. 2. LiftMaster GI Hydraulic Slide Gate Operators. a. Compliance: UL 325 listed, UL 991 and CSA C22.2 No. 247 standards. 1) Ratings: Class I. 2) Ratings: Class II. 3) Ratings: Class III. 4) Ratings: Class IV. b. Operator Speed: 18 inches (457 mm) per second. 3. Warranty: 2 years. 4. Electrical Power Requirements: 115/208/230V AC, single phase, 60 Hz. 5. Electrical Power Requirements: 208/230/460/575V AC, 3-phase, 60 Hz. 6. Motor: 1 HP, continuous duty. a. Capacity: Supports gate lengths up to 80 feet (24.5 m) and gate weights up to 3,000 pounds (1361 kg). 7. Motor: 2 HP, continuous duty. a. Capacity: Supports gate lengths up to 80 feet (24.5 m) and gate weights up to 5,000 pounds (2268 kg). 8. Hydraulic Pump: Maximum 3 gallons per minute. 9. Enclosure: Metal-framed, powder-coated, weatherproof, lockable, 14-gauge pregalvanized steel. 10. Drive Rails: Provide optional drive rails in 8-foot (2438 mm) lengths. 11. Drive Rails: Provide optional drive rails in 20-foot (6096 mm) lengths. 12. Built-in Receiver: Single remote control solution for gate access, extra access points. 13. Integrated 3-Button Control Station: 3-button control station incorporated into the outside of the control box. 14. Inherent Obstruction Sensing: Offers separate force adjustments for both the open and closed directions. If the gate strikes an obstruction, a closing gate will reverse to open and an opening gate will stop. 15. External Obstruction Sensing: Input connections are provided for external contact and non-contact sensors, such as photo eyes and edge devices. 16. Advanced Dual-Gate Operation: 2-wire system allows the operation of 2 separate gate operators in unison at a single entrance; accessories connect to either operator. 17. Sequenced Access Management: Capable of sequentially controlling the operator in tandem with a barrier gate. 18. Limit Settings: NEMA 4, modular and fully adjustable. 19. Maglock Control: Dedicated control relay provided to activate and deactivate locks. 20. LED Indicators: Operator input, status and diagnostic LEDs. 02829-22 21. 22. 23. 24. 25. 26. 27. 28. 29. Q. Control Inputs: Allow the connection of optional external devices like loop detectors, access control systems and radio receivers. Digital Logic Control: Supports long-distance control wiring runs of over 1,000 feet (305 m). Surge and Spike Protection: Circuitry designed to provide protection from external spikes or surges. Warning Device: UL 325 compliant entrapment warning alarm has ability to be set for pre-operation warning; provides 3-second warning prior to and during gate movement. Loop Detector Inputs: Compatible with exit, shadow and interrupt loop detectors. Timer-to-Close: Adjustable timer can be set from 1 to 180 seconds. Unit automatically resets upon receiving any additional open commands. Maximum Run Timer: Protects against damage to the gate and operator by limiting the unit’s run time to 120 seconds. Manual Hydraulic Release: Allows gate to be opened in the event of a power loss without removing the operator cover. Accessories: Provide the optional accessories listed below. a. Plug-in loop detectors. b. Thermostatically controlled fin-type heater. c. Auxiliary contact blocks. d. Remote antenna mounting kit. Gate Operators: LiftMaster MA Series High-Performance Commercial Barrier Gate Operators with Built-in Battery Backup. 1. LiftMaster MA Mega Arm Barrier Gate Operators with plastic cover. 2. LiftMaster MAT Mega Arm Barrier Gate Operators with aluminum cover. 3. Compliance: UL 325 listed, UL 991 and CSA C22.2 No. 247 standards. a. Ratings: Class I. b. Ratings: Class II. c. Ratings: Class III. d. Ratings: Class IV. 4. Warranty: 2 years for operator, 10 years for operator frame. 5. Operation: a. Soft start/stop. b. Universal Controller: 8 inputs right or left-handed operation safety-stop. c. Anti-tailgate, quick-close features. d. Selectable Auto Open: 15 seconds after power failure or upon battery depletion barrier arm can be set to automatically open. 15-second delay helps reduce nuisance callbacks due to short power interruptions or brownouts. 6. Operator Speed: Open or close speed of 2.5 seconds. 7. Gate Arm: Breakaway arm; held in place with breakaway retaining nuts. If arm is hit, it will break away and can be re-installed; can be set up for right or left-hand mount. 8. Gate Arm: Arm one, articulating arm for low headroom environments. 9. Gate Arm: Arm two, yellow. 10. Gate Arm: Arm three, red/white retro-reflectorized DOT tape. a. Gate Arm Length: 12 feet (3658 mm). b. Gate Arm Length: 17 feet (5182 mm). 11. Gate Arms: Arm four, yellow padded arm, 12 feet (3658 mm) and 14 feet (4267 mm) long. 12. Motor: 1/2 HP, 24V DC, 800 RPM motor, 6,000 cycles per day. 13. Electrical Power Requirements: 120/220V AC. 14. Accessory Electrical Power Requirements: 24V DC 500 mA Battery Backup for accessory power. 15. Gear Reduction: 60:1 reducer in synthetic oil bath. 16. Chassis: Powder-coated 1/4-inch (6 mm) aluminum alloy. 17. Drive System: No. 80 gearbox. 02829-23 18. 19. 20. 21. 22. 23. 24. R. Built-in Receiver: Single remote control solution for gate access and additional access points. Ability to add up to 50 remote controls. Magnetic Limit Sensors: Designed for high-cycle applications, contain no moving parts to wear out, provide reliable operation. Surge Protection: Built-in at point of incoming line voltage from power spikes, surges. Auxiliary Outlet: Powers accessories devices. Battery Backup: Provides operation during power outages to maintain traffic flow. Automatically resets to normal operation when power is restored; provides up to 900 full cycles with a 12-foot (3658 mm) arm. Accessories: Provide the optional accessories listed below. a. Clutch: Allows arm to be manually pushed open. Arm automatically resets to normal closed position upon receiving activation. Ideal for areas that are concerned with vandals damaging arm. b. LiftMaster EL2000 Commercial and Gated Community Telephone Entry System. c. LiftMaster STAR1000 Commercial Access Control Receiver. d. LiftMaster 811LM 1-Button Encrypted DIP Remote Control. e. LiftMaster 813LM 3-Button Encrypted DIP Remote Control. f. LiftMaster PPWR Passport Receiver with Security+ 2.0 Technology. 1) LiftMaster PPV1 Passport 1-Button Remote. 2) LiftMaster PPK1 Passport 1-Button Mini Remote. g. LiftMaster KPR2000 Single Access Control Keypad and Proximity Reader. h. LiftMaster LD7LP Low-Power Loop Detector. i. LiftMaster 361LM 1-Button Remote Control. j. LiftMaster 363LM 3-Button Remote Control. Gate Operators: LiftMaster MAS Series High-Speed Commercial Barrier Gate Operators with Built-in Battery Backup. 1. LiftMaster MAS Mega Arm Barrier Gate Operators with plastic cover. 2. LiftMaster MAST Mega Arm Barrier Gate Operators with aluminum cover. 3. Compliance: UL 325 listed, UL 991 and CSA C22.2 No. 247 standards. a. Ratings: Class I. b. Ratings: Class II. c. Ratings: Class III. d. Ratings: Class IV. 4. Warranty: 2 years. 5. Operation: a. Soft start/stop. b. Universal Controller: 8 inputs right or left-handed operation safety-stop. c. Anti-tailgate, quick-close features. d. Selectable Auto Open: 15 seconds after power failure or upon battery depletion barrier arm can be set to automatically open. 15-second delay helps reduce nuisance callbacks due to short power interruptions or brownouts. 6. Operator Speed: Open or close speed of 0.9 second. 7. Gate Arm: Breakaway arm; held in place with breakaway retaining nuts. If arm is hit, it will break away and can be re-installed; can be set up for right or left-hand mount. 8. Gate Arm: Length 8 feet (2438 mm) long, yellow padded arm. 9. Motor: 1/2 HP, 24V DC, 800 RPM motor, 10,000 cycles per day. 10. Electrical Power Requirements: 120/220V AC. 11. Accessory Electrical Power Requirements: 24V DC 500 mA Battery Backup for accessory power. 12. Gear Reduction: 60:1 wormgear reduction in synthetic oil bath. 13. Chassis: Powder-coated 1/4-inch (6.35 mm) T-6 aluminum alloy. 14. Drive System: No. 80 gearbox. 15. Built-in Receiver: Single remote control solution for gate access and additional access points. Ability to add up to 50 remote controls. 02829-24 16. 17. 18. 19. 20. S. Magnetic Limit Sensors: Designed for high-cycle applications, contain no moving parts to wear out, provide reliable operation. Surge Protection: Built-in at point of incoming line voltage from power spikes, surges. Auxiliary Outlet: Powers accessories devices. Battery Backup: Provides operation during power outages to maintain traffic flow. Automatically resets to normal operation when power is restored; provides up to 900 full cycles with a 12-foot (3658 mm) arm. Accessories: Provide the optional accessories listed below. a. Clutch: Allows arm to be manually pushed open. Arm automatically resets to normal closed position upon receiving activation. Ideal for areas that are concerned with vandals damaging arm. b. LiftMaster EL2000 Commercial and Gated Community Telephone Entry System. c. LiftMaster STAR1000 Commercial Access Control Receiver. d. LiftMaster 811LM 1-Button Encrypted DIP Remote Control. e. LiftMaster 813LM 3-Button Encrypted DIP Remote Control. f. LiftMaster PPWR Passport Receiver with Security+ 2.0 Technology. 1) LiftMaster PPV1 Passport 1-Button Remote. 2) LiftMaster PPK1 Passport 1-Button Mini Remote. g. LiftMaster KPR2000 Single Access Control Keypad and Proximity Reader. h. LiftMaster LD7LP Low-Power Loop Detector. i. LiftMaster 361LM 1-ButtonRemote Control. j. LiftMaster 363LM 3-Button Remote Control. Gate Operators: LiftMaster BG770 Industrial Barrier Gate Operator. 1. Compliance: UL 325 listed, UL 991 and CSA C22.2 No. 247 standards. a. Ratings: Class I. b. Ratings: Class II. c. Ratings: Class III. d. Ratings: Class IV. 2. Warranty: 2 years. 3. Operator Speed: 90-degrees in 4 seconds. 4. Gate Arms: Standard, 12-foot (3658 mm) wood arms. 5. Gate Arms: Provide optional 10-foot (3048 mm) PVC arms. 6. Gate Arms: Provide optional 15-foot (4572 mm) aluminum arms, square, yellow and black stripes. 7. Electrical Power Requirements: 115/208/230V AC, single phase, 60 Hz. a. Accessory Electrical Power Requirements: One, 115V AC. b. Accessory Electrical Power Requirements: One, 24V AC. 8. Electrical Power Requirements: 208/230/460/575V AC, 3-phase, 60 Hz. a. Accessory Electrical Power Requirements: One, 24V AC. 9. Gear Reduction: 60:1 wormgear reduction in oil bath. 10. Motor: 1/2 HP, continuous duty. 11. Metal Frame: 11-gauge pre-galvanized steel. 12. Enclosure: Powder-coated weather-resistant steel enclosure. 13. Configuration: Standard. 14. Configuration: Reverse cabinet modification: In the event of an obstruction close by the barrier gate the cabinet can be reversed to allow access to cabinet door. 15. Control Inputs: Control inputs allow the connection of optional external devices like loop detectors, photo eyes, telephone entry systems, access control systems and radio receivers. 16. Limit Settings: Driven limit cams are fully adjustable. 17. Accessories: Provide the optional accessories listed below. a. SAMS Limit Switch Modification: Compatible with sequenced access management systems, as a single or pair; compatible with systems with a GL control board. 02829-25 b. c. d. e. f. g. h. Dual-Gate Capability: Supports the operation of 2 separate gate operators in unison at a single entrance, assuring consistent, simultaneous open/close cycle for both operators and is bi-part capable. Timer-to-Close: Programmable module can be set from 1 to 1,024 seconds. The unit will automatically close when programmed time has expired. Plug-in Style Loop Detectors: Operator incorporates 2-harness support system that can accept up to 2 plug-in loop detectors for exit or hold-open functions. Long-Distance Wiring Module: Allows mounting accessories or controls beyond 100 feet (30 m) from the operator. Flex Red Light Strip: 10 feet (3048 mm) long. Thermostatically Controlled Heater: For use in extreme cold environments. Single-Button Radio Modification: Enables radio control to both open and close the barrier arm. T. Gate Operators: LiftMaster BG790 Industrial Barrier Gate Operator. 1. Compliance: UL 325 listed, UL 991 and CSA C22.2 No. 247 standards. a. Ratings: Class I. b. Ratings: Class II. c. Ratings: Class III. d. Ratings: Class IV. 2. Warranty: 2 years. 3. Operator Speed: 11 seconds opening time. 4. Electrical Power Requirements: 115/208/230V AC, single phase, 60 Hz. a. Accessory Electrical Power Requirements: One, 115V AC. b. Accessory Electrical Power Requirements: One, 24V AC. 5. Electrical Power Requirements: 208/230/460/575V AC, 3-phase, 60 Hz. a. Accessory Electrical Power Requirements: One, 24V AC. 6. Gear Reduction: 60:1 wormgear reducer in oil bath. 7. Motor: 1/2 HP, continuous duty. 8. Metal Frame: 11-gauge pre-galvanized steel. 9. Gate Arms: Includes 24-foot (7315 mm) wishbone arm with black and white stripes and 2 counterweights. 10. Enclosure: Powder-coated weather-resistant steel enclosure. 11. Configuration: Standard. 12. Configuration: Reverse cabinet modification: In the event of an obstruction close by the barrier gate the cabinet can be reversed to allow access to cabinet door. 13. Control Inputs: Control inputs allow the connection of optional external devices like loop detectors, photo eyes, telephone entry systems, access control systems and radio receivers. 14. Limit Settings: Driven limit cams are fully adjustable. 15. Accessories: Provide the optional accessories listed below. a. Dual-Gate Capability: Supports the operation of 2 separate gate operators in unison at a single entrance, assuring consistent, simultaneous open/close cycle for both operators and is bi-part capable. b. Timer-to-Close: Programmable module can be set from 1 second to 17 minutes. The unit will automatically close when programmed time has expired. c. Plug-in Style Loop Detectors: Operator incorporates 2-harness support system that can accept up to 2 plug-in loop detectors for exit or hold-open functions. d. Long-Distance Wiring Module: Allows mounting accessories or controls beyond 100 feet (30 m) from the operator. e. Flex Red Light Strip: 10 feet (3048 mm) long. f. Thermostatically Controlled Heater: For use in extreme cold environments. g. Single-Button Radio Modification: Enables radio control to both open and close the barrier arm. U. Gate Operators: LiftMaster HCT Series Heavy-Duty, High-Cycle Trolley Gate Operators. 02829-26 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. V. LiftMaster HCT501103-8 Heavy-Duty, High-Cycle Trolley Gate Operators, 141 inches (3581 mm). LiftMaster HCT501103-10 Heavy-Duty, High-Cycle Trolley Gate Operators,165 inches (4191 mm). LiftMaster HCT501103-12 Heavy-Duty, High-Cycle Trolley Gate Operators, 189 inches (4800 mm). Built-in Radio Receiver: Provides 312 MHz receivers, opens gate and stores up to 31 Security+ remote controls. Built-in Radio Receiver: Provides optional LiftMaster STAR1000 Commercial Access Control Receivers. Compliance: ETL listed; compliant with UL 325 and CSA C22.2 No. 247 standards. a. Ratings: Class I. b. Ratings: Class II. c. Ratings: Class III. d. Ratings: Class IV. Warranty: 5 years. Electrical Power Requirements: 120V AC. Chassis: Zinc-coated steel. Gear Reduction: 40:1 gear reducer. Motor: 1/2 HP, continuous duty. 3-Button Control: On-board, for open, close and stop. Power Input On/Off Switch: Controls input to the board. Safety Alarm: If the door or gate hits an object twice while opening or closing, the system will shut down and the alarm will sound for 5 minutes, after which time the system will reset; manual reset button to reset system within 5-minute window. Timer: Adjustable from 3 to 60 seconds. Trolley Assembly: Trolley operates on 6 UHMW rollers. Key Release: Emergency release in the event of loss of power. Accessories: Provide the optional accessories listed below. a. Photo eye controls. b. Sensing edge. c. Optional OMNI board. d. Plug-in loop detectors. LiftMaster CPS-RPEN4GM Monitored Retro-Reflective Photo Eye. 1. LiftMaster CPS-RPEN4GM Monitored Retro-Reflective Photo Eye: Photo eye assembly, bracket, 3-inch (76 mm) reflector, 6-1/2 foot (1981 mm) cable. 2. LiftMaster CPSR-VALPAK includes: a. LiftMaster CPS-RPEN4GM Monitored Retro-Reflective Photo Eye: Photo eye assembly, bracket, 3-inch (76 mm) reflector, 6-1/2 foot (1981 mm) cable. b. LiftMaster LOOPDETLM Loop Detectors, 2 per unit. c. LiftMaster 893MAX 3-Button Remote Controls, 2 per unit. 3. Compliance: a. Meets UL 325 requirements for gates for secondary entrapment protection. b. Enclosure: IP65, NEMA 4X waterproof enclosure. 4. Installation Design: a. Single-sided, does not require trenching. b. Alignment: LED indicator with visible feedback and adjustable photo eye assembly. 5. Photo Eye Beam: Polarized beam technology sends and receives beam through 2 polarized filters to avoid interference from shiny objects. 6. Sensing Distance: 50 feet (15 m). 7. Operating Temperature Range: -22 degrees F (-30 degrees C) to 140 degrees F (60 degrees C). 8. Power: LiftMaster 2-wire photo eye interface. 9. Operating Current: Greater than or equal to 40 mA. 02829-27 10. 11. 12. 13. Output Versions: Monitored 2-wire. Response time: 30 milliseconds. Wake-up Delay: 500 milliseconds. Connection: 6-1/2 foot (1981 mm) cable, fine stranded with crimp terminals wire size 1 sq. inch (25 sq. mm). PART 3 EXECUTION 3.1 3.2 EXAMINATION AND PREPARATION A. Inspect and prepare substrates using the methods recommended by the manufacturer for achieving best result for the substrates under project conditions. B. Do not proceed with installation until substrates have been prepared using the methods recommended by the manufacturer and deviations from manufacturer’s recommended tolerances are corrected. Commencement of installation constitutes acceptance of conditions. C. If preparation is the responsibility of another installer, notify Architect in writing of deviations from manufacturer’s recommended installation tolerances and conditions. INSTALLATION A. 3.3 Install in accordance with manufacturer’s instructions. Test for proper operation and adjust until satisfactory results are obtained. PROTECTION A. Protect installed products until completion of project. B. Touch up, repair or replace damaged products before Substantial Completion. END OF SECTION 02829-28