SECTION 07 27 26 LIQUID APPLIED VAPOR PERMEABLE AIR/MOISTURE BARRIER SPECIFIER NOTE: This Short Form specification is intended for use by the design professional to assist in developing project specifications for the application of a Liquid Applied Vapor Permeable Air/Moisture Barrier – BEP Blue Barrier Liquid Wrap or BEP Blue Barrier Flash ‘N Wrap RG to vertical above grade concrete, masonry, and sheathed wall construction. BEP Blue Barrier Liquid Wrap and BEP Blue Barrier Flash ‘N Wrap RG are designed for use beneath claddings such as brick veneer with a cavity, vinyl, wood, and fiber cement siding. They can also be used behind Portland cement stucco with code compliant metal lathe and a slip-sheet, typically code approved building paper or felt. BEP Blue Barrier Liquid Flashing or BEP Blue Barrier Flash ‘N Wrap RG and BEP Blue Barrier Joint Filler are to be used in conjunction with BEP Blue Barrier Liquid Wrap per the application guides. It is the responsibility of the Specifier to determine if a product is suitable for its intended use including but not limited to all decisions pertaining to design, detail, structural capability, attachment details, shop drawings and the like. Dominus Innovations has prepared guidelines in the form of specifications, typical application details, and product bulletins to facilitate the design process only. Dominus Innovations is not liable for any errors or omissions in design, detail, structural capability, attachment details, shop drawings or the like, whether based upon the information provided by Dominus Innovations or otherwise, or for any changes which the purchasers, specifiers, designers or their appointed representatives may make to the manufacturers comments. Please note that any joints or gaps between adjoining components as well as mechanical penetrations, etc. are of primary importance to maintain continuity of an air/moisture barrier system and must be considered by the design professional in the overall wall assembly design. Stucco claddings require the use of a slip-sheet installed. Rev 07/22/2013 Air/Moisture Barrier 07 27 26 Short Form SECTION 07 27 26 LIQUID APPLIED VAPOR PERMEABLE AIR/MOISTURE BARRIER PART 1 - GENERAL RELATED DOCUMENTS NOTE: Delete or revise coordination of project general conditions. General Conditions vary from project to project and method of construction. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. SUMMARY A. This Section includes the following: NOTE: Add or Delete paragraphs or sub-paragraphs list below to suit Project. 1. B. Liquid Applied Vapor Permeable Air/Moisture Barrier System: Vapor permeable, liquid applied system located in non-accessible part of assembly. Related Sections include the following: NOTE: Delete or revise coordination of related bridge materials related to this section or that flashing section stands alone. 1. Division 07 Section “Liquid Applied Window and Door Flashing” for scope of work that requires this section. 2. Division 07 Section “Liquid Applied Vapor Permeable Air/Moisture Bridge” for scope of work that requires this section. DEFINITIONS A. Liquid Applied Vapor Permeable Air/Moisture Barrier Assembly: Collection of liquid applied air/moisture barrier materials and auxiliary materials applied to an opaque wall, including joints and junctions to abutting construction, to control air and moisture movement through building assemble. Rev 07/22/2013 Page 1 of 5 Air/Moisture Barrier 07 27 26 Short Form SUBMITTALS A. Product Data: Include manufacturer's written application guide instructions, technical data sheets and tested physical and performance properties of air/ moisture barrier. QUALITY ASSURANCE A. Applicator Qualifications: A firm experienced in applying air/moisture barrier materials similar in material, design, and extent to those indicated for this Project. NOTE: Add Mock-up paragraph below if additional items, location, size, components required. B. Mockups: Before beginning installation of air/moisture barrier, build mockups of exterior wall assembly. DELIVERY, STORAGE, AND HANDLING NOTE: Add more specific items to paragraph below location, covering off-site protection. A. Storage: Deliver and store materials in original undamaged packages in clean, dry, protected location within temperature range required by air/moisture barrier manufacturer’s Technical Data Sheets. PROJECT CONDITIONS NOTE: Add or Delete paragraph below for other climate conditions and storage availability or off-site storage. A. Environmental Limitations: Apply liquid applied vapor permeable air/moisture barrier within the range of ambient and substrate temperatures recommended by air/moisture barrier manufacturer’s Installation and Application Guide. WARRANTY A. Warranty: Provide manufacturers material warranty. Rev 07/22/2013 Page 2 of 5 Air/Moisture Barrier 07 27 26 Short Form PART 2 - PRODUCTS LIQUID APPLIED VAPOR PERMEABLE AIR/MOISTURE BARRIER NOTE: Add more specific data requirements that reinforce the performance of the air/moisture barrier including ASTM and ABAA requirements. A. Liquid Applied Vapor Permeable Air/Moisture Barrier: Components and accessories obtained as a single source from liquid applied vapor permeable air/moisture barrier manufacturer to ensure total assembly compatibility and integrity. B. Material: Single-stage application, seamless, proprietary modified (STPE) Silyl Terminated polyether technology, cold applied liquid, vapor permeable, mold resistant, air/moisture membrane. C. Manufacturer: Dominus Innovations LLC 2202 North West Shore Boulevard Suite 200 Tampa, FL 33607 Telephone Number 1 813 279 1902 Website: BEPproducts.com AUXILIARY MATERIALS NOTE: Add more specific data requirements that reinforce auxiliary product performance of the air/moisture barrier and add/delete auxiliary requirements required for the project. A. General: Auxiliary materials recommended by liquid applied vapor permeable air/moisture barrier manufacturer for intended use and compatible with liquid applied vapor permeable air/moisture barrier membrane. B. Primer: No primer required. C. Liquid Flashing: “BEP Blue Barrier Liquid Flashing 2100” or “BEP Flash ‘N Wrap RG 2400” D. Substrate Patching: Closed cell backer rod and/or closed cell expanding foam as recommended in manufacturer’s Installation and Application Guide. E. Joint Filler: “BEP Blue Barrier Joint Filler 2200”. Rev 07/22/2013 Page 3 of 5 Air/Moisture Barrier 07 27 26 Short Form PART 3 - EXECUTION EXAMINATION A. Examination: Examine substrates, areas, and conditions, with installer present, for compliance with manufacturer’s Installation and Application Guide requirements and other conditions affecting performance. NOTE: Add more specific requirements that will benefit the preparation required for the project. SURFACE PREPARATION A. Preparation: Clean and prepare substrate according to manufacturer's Installation and Application Guide. JOINT TREATMENT A. Treatment: Prepare, rout, and fill joints and cracks in substrate according to ASTM C 1193 and air/moisture barrier manufacturer's Installation and Application Guide. FLASHING INSTALLATION A. Installation: Flash heads, sills and bridge terminations at perimeter frame surfaces of windows, curtain walls, storefronts, and doors, and miscellaneous penetrations with liquid flashing or flash ‘n wrap rg in conjunction with joint filler material as recommended by manufacturer for a complete watertight construction. B. Preparation for Additional Coats: Wipe down air/moisture barrier with approved solvent and bring back to tacky per manufacturer’s Installation and Application Guide. LIQUID APPLIED VAPOR PERMEABLE AIR/MOISTURE BARRIER INSTALLATION NOTE: Add more specific requirements for special installation requirements including procedure for wet, applicator requirements, overlapping, and inspection. A. Application: Apply liquid applied vapor permeable air/moisture barrier within manufacturer's recommended application temperature ranges. Substrate may be damp to the touch in accordance with manufacturer’s Installation and Application Guide. Rev 07/22/2013 Page 4 of 5 Air/Moisture Barrier 07 27 26 Short Form B. Installation: Apply continuous unbroken liquid applied vapor permeable air/moisture barrier with approved spray or roller equipment to substrates according to the following minimum thickness. Apply membrane in full contact around protrusions: C. Liquid Applied Vapor Permeable Air/Moisture Barrier: 15-20 mil wet film thickness using crosshatch spray pattern when spraying as recommended by manufacturer or roll to an even coat of 15-20 mil wet film thickness as recommended by manufacturer. CLEANING AND PROTECTION A. Protection: Protect liquid applied vapor permeable air/moisture barrier system from damage during remainder of construction period. B. Cleaning: Clean spills, stains, and soiling from construction that would be exposed in the completed work using cleaning agents and procedures recommended by manufacturer of affected construction. END OF SECTION 07 26 26 Rev 07/22/2013 Page 5 of 5 Air/Moisture Barrier 07 27 26 Short Form