Supporting Information Reagents and standards n-Dibutyl phthalate (DBP) and diethylhexyl phthalate (DEHP) were purchased from the Tianjin Chemical Reagent No. 2 Plant (Tianjin, China). Potassium sodium tartrate (KNaC4H4O6·4H2O) was purchased from the Shantou Xilong Chemical Co. (Shantou, China). Sodium dodecyl benzene sulfonate (SDBS) was purchased from the Beijing Chemical Reagents Co. (Beijing, China). Copper (II) sulfate pentahydrate (CuSO4·5H2O) was purchased from Sinopharm Chemical Reagent Co. (Shanghai, China). Nickel (II) chloride hexahydrate (NiCl2·6H2O) was purchased from the Tianjin Guangfu Fine Chemical Research Institute (Tianjin, China). Palladium(II) chloride (PdCl2) and Tin(II) chloride (SnCl2) was purchased from Shengyang Keda Chemical Reagent Co. (Shengyang, China). Anhydrous sodium carbonate (Na2CO3) was obtained from the Shanghai Sanyou Chemical Reagent Co. (Shanghai, China). Sodium hydroxide (NaOH) was purchased from the Shanghai Shanpu Chemical Co. (Shanghai, China). All chemicals were of analytical grade. Analytes were dissolved in ethanol with concentration of 1.0 mg mL-1 and stored at 4 °C for use. Apparatus An Agilent 7890A series gas chromatography (Agilent Technologies, USA) equipped with a flame ionization detector (FID) and splitless inlet was used in the analysis. Chromatographic separation was accomplished with a HP-5 column (30 m × 0.32 mm × 0.25 μm). The injector and detector temperatures were set at 280 and 300 °C, respectively. Ultrapure nitrogen (99.999%) was used as carrier and make-up gas, and the flow rates were set at 1 mL min-1 and 25 mL min-1, respectively. Separation was achieved using temperature programs as follows: the column temperature was initially held at 120 °C, and programmed at 10 °C min-1 to 300 °C. The desorption of the extracted analytes was performed at 280 °C for 3 min. Surface morphological studies were carried out by a scanning electron microscope (SEM, JSM-6701F, JEOL Ltd., Japan) equipped with an energy dispersive X-ray spectroscopy (EDS). EDS analysis of the copper fiber: Element Line Weight% Cnts/s Atomic% ----------------------------------------------Cr Ka 0.72 18.87 0.87 Fe Ka 2.75 62.71 3.10 Ni Ka 3.32 47.42 3.56 Cu Ka 93.22 1016.06 92.47 Effect of content of NaCl on peak area Effect of content of NaCl on peak area. Conditions: extraction time, 40 min; extraction temperature, 30 °C; desorption time 3 min; desorption temperature, 280 °C; concentration of analytes, 50 μg L-1, sample volume, 10 mL.