Stenbråtlia Recommended adjustments (House type B) For the floor heating system and the solar system Menu Main menu Advanced menu Menu choices Zone 1 (Hall downstairs) Zone 2 (Bath downstairs) Zone 3 (Living room) Zone 4 (Sleeping room) Zone 5 (Bath upstairs) Vacation (Temperature decreases to 15 °C). Stop Zone 1 Stop Zone 2 Stop Zone 3 Stop Zone 4 Stop Zone 5 D Min 1 D Min 2 D Min 3 D Min 4 D Min 5 DT, T0 DT, d Adjustment 22 25 22 19 25 Amount of days. 17 °C 25 °C 17 °C 12 °C 25 °C 6% 8% 6% 3% 8% 28 0,50 SOL, Start SOL, Stopp MAX FLOW 6 °C 3 °C 70 °C 21 l/min. PAS TID, Hours TID, Minutes 45 °C Free of choice Free of choice 1 Explanation Adjustments of desired indoor temperature. (Must not be confused with actual indoor temperature). Adjustment of the outdoor temperature where the heat in the chosen zone is turned off. (This is a measured temperature). Adjustment of the least desired heat supply to the chosen zone. Adjustments of the basic parameters on the Dynamic Thermostat, which determines the temperature level in the heat tank. Adjustments of the start and stop values on the solar system. Adjustment of the maximum temperature in the heat tank. Adjustment of water flow (l/min) through the solar collector for calculations of the gained solar energy. Safety adjustments for the floor heating system. Clock adjustments. Correct time settings has no importance for the remaining heat regulations. Expert menu Outlet 1 Outlet 2 Outlet 3 Outlet 4 Outlet 5 Outlet 6 A A A A A A Outlet 7 A Outlet 8 A Outlet 9 UFloor 1 UFloor 2 UFloor 3 UFloor 4 UFloor 5 URoom 1 URoom 2 URoom 3 URoom 4 URoom 5 0 1,8 2,5 1,7 2,0 1,5 0,7 0,7 0,7 0,7 0,7 2 Stop/Start/Auto Zone 1 Stop/Start/Auto Zone 2 Stop/Start/Auto Zone 3 Stop/Start/Auto Zone 4 Stop/Start/Auto Zone 5 Stop/Start/Auto electrical heating element Stop/Start/Auto pump to floor heating Stop/Start/Auto pump to solar collector This outlet is not in use. U-value for the floor in Zone 1 U-value for the floor in Zone 2 U-value for the floor in Zone 3 U-value for the floor in Zone 4 U-value for the floor in Zone 5 U-value for the building Zone 1 U-value for the building Zone 2 U-value for the building Zone 3 U-value for the building Zone 4 U-value for the building Zone 5