Connection CAUTION Settings of connections shall reflect actual state otherwise measurements could not be valid. Connection: LCD navigation MC784 Main menu Settings Measurements General Settings Date & Time Resets Connection SD card Communication Info LCD Installation Security 14.11.2012 16:53:36 Energy Inputs/Outputs Main menu MC7X0 Main menu Settings Measurements General Settings Date & Time Resets Connection MMC card Communication Info LCD Installation Security 14.11.2012 16:53:36 Energy Inputs/Outputs Main menu MC320, MC330 Main menu Settings Measurements General Settings Connection Resets Communication Info LCD Installation Security 14.11.2012 16:53:36 Energy Inputs/Outputs Main menu MC350 Main menu Settings Measurements General Settings Date & Time Resets Info Installation 14.11.2012 Connection Communication LCD 16:53:36 Security Energy Inputs/Outputs Connection mode When connection is selected, load connection and the supported measurements are defined. Setting of current and voltage ratios Before setting current and voltage ratios it is necessary to be familiar with the conditions in which device will be used. All other measurements and calculations depend on these settings. Up to five decimal places can be set (up / down). To set decimal point and prefix (up / down) position the cursor (left /right) to last (empty) place or the decimal point. Aux CT transformer ratios can be set separately from phase CT ratios since Aux CT could differ from phase CTs. Range of CT and VT ratios: Settings range VT primary VT secondary CT, Aux CT primary CT, Aux CT secondary Max value 1638,3 kV 13383 V 1638,3 kA 13383 A Min value 0,1 V 1 mV 0,1 A 1 mA Setting of current and voltage ratios : Primary voltage (V), Secondary voltage (V), Primary current (A), Secondary current (A) Before setting current and voltage ratios it is necessary to be familiar with the conditions in which device will be used. All other measurements and calculations depend on these settings. Up to five decimal places can be set (up / down). To set decimal point and prefix (up / down) position the cursor (left /right) to last (empty) place or the decimal point. Settings range VT primary VT secondary CT, Aux CT primary CT, Aux CT secondary Max value 1638,3 kV 13383 V 1638,3 kA 13383 A Min value 0,1 V 1 mV 0,1 A 1 mA Neutral line Primary/Secondary current (A) Primary /Secondary current of neutral line current transformer. Used voltage/current range (V/A) Setting of the range is connected with all settings of alarms, analogue outputs and a display (calculation) of energy and measurements recording, where 100% represents 500 V. In case of subsequent change of the range, alarms settings shall be correspondingly changed, as well. CAUTION In case of subsequent change of those ranges shall be alarm and analogue output settings correspondingly changed as well. Already recorded values will not be valid after change of used voltage and current range! Frequency nominal value (Hz) Nominal frequency range can be selected from a set of predefined values. A valid frequency measurement is within the range of nominal frequency ±32 Hz. This setting is used for alarms and recorders only. Max. demand current for TDD (A) Select maximum current (CT or fuse rating) at a point of instrument connection for proper TDD calculation. TDD is unlike THD a measure of harmonics relative to fixed value of max. demand current. Therefore TDD is a demand independent measure of current harmonics. Wrong connection warning If all phase currents (active powers) do not have same sign (some are positive and some negative) and/or if phase voltages and phase currents are mixed, the warning will be activated if this setting is set to YES. This warning is seen only on remote display. Energy flow direction This setting allows manual change of energy flow direction (IMPORT to EXPORT or vice versa) in readings tab. It has no influence on readings sent to communication or to memory. CT connection If this setting is set to REVERSED it has the same influence as if CT’s would be reversely connected. All power readings will also change its sign. This setting is useful to correct wrong CT connections. LCD navigation MC784 Main menu Settings Measurements General Settings Date & Time Resets Connection Info Communication Installation LCD 14.5.2015 16:53:36 Security Energy Inputs/Outputs Main menu Main menu > Settings > Connection > Connection mode Main menu > Settings > Connection > VT primary/VT secondary/CT primary/CT secondary