This section addresses Pittco Standard Narrow, Medium, and Wide Stile Aluminum Doors, and
includes aluminum doors and frames and single pane or double pane sealed insulating unit glazed
lites, for exterior or interior applications, shop fabricated, factory pre-finished, including shop or
field glazing. Glass and Glazing is referenced to Section 088000. Door hardware may be specified
in this section or specified in Section 087100; edit text accordingly. Where work of this section
integrates with a glazed wall or other glazed assembly, carefully coordinate both sections to function
together. This section includes performance, proprietary and descriptive type specifications. Edit to
avoid conflicting requirements.
During editing, delete all blue text boxes such as this text box. Also, select one of the options shown in
blue for each section and delete the remaining options. Change the text color to black for the selected
option.
PART 1 - GENERAL
1.1
SECTION INCLUDES
A. Aluminum single and double leaf standard glazed doors.
B.
Single pane and Double pane insulating sealed unit vision glass.
Include the following paragraph if door hardware is specified in Part 2 of this section; delete the
following paragraph if hardware is referenced in Section 087100 – Door Hardware.
C.
Furnish [Pittco Standard Door Hardware] [Custom Door Hardware indicated in Part 2] [Door Hardware
referenced in Section 087100].
D. Perimeter sealant.
E.
1.2
RELATED SECTIONS
Select and edit the paragraphs in this article – delete those that do not apply to the project.
A. Section 079200 – Joint Sealants: Assembly perimeter sealant and back-up materials.
B.
Section 084233 – Revolving Door Entrances
The following paragraph describes automatic door operating hardware.
C.
Section 087400 – Access Control Hardware.
The following paragraph describes Pittco EMS 114 framing assemblies.
Pittco Architectural Metals, Inc.
Pittco Standard Entrance Door
October 1, 2014
081316
Aluminum Door
Page 2
D. Section 084313 – Aluminum single glazed storefront assembly: preparation of frame, including
reinforcement, to receive hardware and Work of this section.
The following paragraph describes Pittco TMS 114, TMS 114 T, TMS 114 UF, TMS 114 TUF, TMS
114 XT framing assemblies.
E.
Section 084313 – Aluminum double glazed storefront assembly: preparation of frame, including
reinforcement, to receive hardware and Work of this section.
The following paragraph describes Pittco TMW 450, TMW 453, 70 Wall, and 70 Wall XT framing
assemblies.
F.
Section 084413 –Glazed Aluminum Curtain Wall assembly with subframe: preparation of subframe,
including reinforcement, to receive hardware and Work of this section.
The following paragraph describes Pittco TMW 450 EFG, TMW 453 EFG, EFG 800, and 70 Wall XT
framing assemblies.
G. Section 084423 –Structural Sealant Glazed Curtain Wall assembly with subframe: preparation of
subframe, including reinforcement, to receive hardware and Work of this section.
The following paragraph describes Pittco Flushlok II , TMW 250, and TMW 250 EFG framing
assemblies.
H. Section 085113 – Aluminum Window assembly: preparation of frame, including reinforcement, to
receive hardware and Work of this section.
Include the following paragraph if hardware is referenced to Section 087100 – Door Hardware.
I.
Section 087100 – Door Hardware: Mortised hardware reinforcement requirements affecting framing
members.
J.
Section 087113 – Automatic Door Equipment.
K.
Section 088000 – Glass and Glazing.
L.
Section 099000 – Painting: Field painting of interior surface of infill panel [and {_______}] surfaces.
M. Section [_______]: Wall fin convectors and support saddles attached to the framing members.
N.
1.3
REFERENCES
List reference standards included within the text of this section. Edit the following as required for
project conditions. Standards with an “M” after the designation are metric versions.
A. AA (Aluminum Association), Designation System for Aluminum Finishes.
Pittco Architectural Metals, Inc.
Pittco Standard Entrance Door
October 1, 2014
081316
Aluminum Door
Page 3
B.
AAMA SFM-1-87, Aluminum Storefront and Entrance Manual.
C.
AAMA 501.1-05, Standard Test Method for Water Penetration of Windows, Curtain Walls and doors
using Dynamic Pressure.
D. AAMA 501.2-09, Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts,
Curtain Walls, and Sloped Glazing Systems.
E.
AAMA 503-08, Voluntary Specification for Field Testing of Newly Installed Fenestration Products
F.
AAMA 609/610-09, Cleaning and Maintenance Guide for Architecturally Finished Aluminum.
G. AAMA 611-12, Voluntary Specifications for Anodized Architectural Aluminum.
H. AAMA 1503-09, Voluntary Test Method for Thermal Transmittance and Condensation Resistance of
Windows, Doors, and Glazed Wall Sections.
I.
AAMA 2604-10, Voluntary Specification, Performance Requirements and Test Procedures for High
Performance Organic Coatings on Aluminum Extrusions and Panels.
J.
AAMA 2605-11, Voluntary Specification, Performance Requirements and Test Procedures for Superior
Performing Organic Coatings on Aluminum Extrusions and Panels.
K.
ASTM A 123/A 123M, Zinc (Hot Dip Galvanized) Coatings on Iron and Steel Products.
L.
ASTM A 653/A 653M, Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated
(Galvanized) by the Hot-Dip Process.
M. ASTM B 209/B 209M, Aluminum and Aluminum-Alloy Sheet and Plate.
N. ASTM B 221/B 221M, Aluminum and Aluminum-Alloy Extruded Bar, Rod, Wire, Shape and Tube.
O. ASTM E 283, Rate of Air Leakage Through Exterior Windows, Skylights, Curtain Walls, and Doors.
P.
ASTM E 330, Test Method for Structural Performance of Exterior Windows, Skylights, Curtain Walls, and
Doors by Uniform Static Air Pressure Difference.
Q. ASTM E 331, Test Method for Water Penetration of Exterior Windows, Skylights, Curtain Walls, and
Doors by Uniform Static Air Pressure Difference.
R.
1.4
SYSTEM DESCRIPTION
Use this article carefully; restrict statements to describe components used to assemble the system. Do
not repeat statements made if the Section includes article in Part 1, Section 1.1.
A. Aluminum doors include tubular aluminum sections with supplementary internal tensioned-rod support
framing, interlocking rigid corners, shop fabricated, factory finished, vision glass, anchorage and
attachment devices.
B. Door and Frame Assembly: Factory assembled.
C.
1.5
PERFORMANCE REQUIREMENTS
Use this article carefully; restrict statements to identify system performance requirements or
functional criteria only. Delete paragraphs not appropriate to project. Performance specifying
permits system manufacturers the latitude to adjust proprietary systems to achieve specified
requirements. Rely on this article as the basis for entrance criteria specifying and minimize the
material and component statements so not to conflict with performance criteria. The following
paragraphs represent a suggested listing of criteria. If more stringent criteria are being considered,
refer to AAMA and ASTM test methods and associated documents for guidance.
Pittco Architectural Metals, Inc.
Pittco Standard Entrance Door
October 1, 2014
081316
Aluminum Door
Page 4
A. Assembly Design: Design and size components to withstand dead and live loads caused by positive and
negative wind pressure acting normal to the plane of the wall as calculated in accordance with the
applicable code.
B.
Assembly: Accommodate without damage to components or deterioration of seals, movement
between system and peripheral construction, dynamic loading and release of loads, deflection of
structural support framing.
C.
Structural Performance – Deflection: Limit mullion deflection to [flexural limit of glass,] [L/175] [_____]
[L/240 + 1/4” for spans greater than 13’-6”] as measured in accordance with ASTM E 330 at [_____] psf
([_____] Pa); with full recovery of members.
D. Air Infiltration: Limit air leakage between door and supporting frame assembly to [0.50] [_____]
cfm/ft2 ([12.5] [_____] L/m2•s) for single door leaves and [1.0] [_____] cfm/ft2 ([25] [_____] L/m2•s) for
pairs of leaves, measured at a reference differential pressure across the assembly of [1.57] psf (75 Pa)
as measured in accordance with ASTM E 283.
E.
Condensation Resistance Factor (CRF): [CRF 27 with 1” Insulated clear glass unit] [CRF 27 with 1” Low E
insulated glass unit] [CRF 27 with 1” Low E insulated glass unit and argon fill] [_____] when measured in
accordance with AAMA 1503.
F.
Thermal Transmittance (U Factor): [U value 0.87 with 1” insulated clear glass unit] [U value 0.80 with 1”
Low E insulated glass unit] [u value 0.78 with 1” Low E insulated glass unit and argon fill] [_____]
BTU/hr• ft2•degree F when measured in accordance with AAMA 1503.
G. Air and Vapor Seal: Maintain continuous air barrier and vapor seal throughout assembly, primarily in
line with lite of glass.
H. Expansion/Contraction: Provide for expansion and contraction within assembly components caused by
ambient cycling temperature range of [170] [_____] degrees F ([77] [_____] degrees C) over a twelve
(12) hour period based on a metal installation temperature of 85 degrees F (29 degrees C), without
causing detrimental effect to assembly components and anchorage.
I.
System Internal Drainage: Drain water entering joints, condensation occurring in glazing channels, or
migrating moisture occurring within system, to the exterior by a weep drainage network.
J.
1.6
SUBMITTALS FOR REVIEW
Do not request submittals if drawings sufficiently describe the products of this section or if
proprietary specifying techniques are used. The review of submittals increases the possibility of
unintended variations to drawings, thereby increasing the Specifier’s liability. The following
submittals are intended for review and approval or other action by the Specifying Authority.
A. Section [013300:] [_______:] Submission Procedures.
B. Product Data: Provide component dimensions; describe components within assembly, anchorage and
fasteners, glass, [door hardware,] internal drainage details and [_______].
Pittco Architectural Metals, Inc.
Pittco Standard Entrance Door
October 1, 2014
081316
Aluminum Door
Page 5
C. Design Data: Provide framing member structural and physical characteristics, [calculations,]
dimensional limitations.
D. Shop Drawings: Indicate system dimensions, framed opening requirements and tolerances, affected
related work and expansion and contraction joint location and details.
Use the following paragraph(s) for submission of physical samples for selection of finish, color,
texture, etc.
E.
Submit [two] [_____] samples [1-3/4 x 4 inch] [_____ x _____] inch [45 x 100 mm] [_____ x _____] mm
in size illustrating finished aluminum surface.
F.
Submit [two] [_____] samples [12 x 12 inch] [_____ x _____] inch [305 x 305 mm] [_____ x _____] mm
in size illustrating glass infill, glazing materials.
G.
1.7
SUBMITTALS FOR INFORMATION
The following submittals are informational; responsive action by the Specifying Authority is not
required.
A. Section [0133000:] [_______:] Submission procedures.
B.
Manufacturer’s Certificate: Certify that [Products] [_____] meet or exceed [specified requirements.]
[_______.]
C.
1.8
SUBMITTALS FOR PROJECT CLOSEOUT
The following submittals are for project close-out purposes.
A. Section [017000:] [_______:] Submission Procedures.
B.
Submit manufacturer warranty and ensure forms have been completed in Owner’s name and registered
with manufacturer.
C.
1.9
QUALITY ASSURANCE
Only include this article if the specified system is extensive and warrants special design attention. The
subsequent paragraph is to address requirements for the handicapped.
A. Design and fabricate according to AAMA SFM-1.
B.
Manufacturer [and Installer]: Company specializing in manufacturing aluminum glazing systems with
minimum [three] [_____] years [documented] experience.
Pittco Architectural Metals, Inc.
Pittco Standard Entrance Door
October 1, 2014
C.
081316
Aluminum Door
Page 6
Design structural support framing components under direct supervision of a Professional Structural
Engineer experienced in design of this work and licensed at the place where the Project is located.
D.
1.10 PRE-INSTALLATION MEETING
A. Section [013000:] [_______:] Pre-installation meeting.
B.
Convene [one] [_____] week before starting work on this section.
C.
1.11 DELIVERY, STORAGE, AND PROTECTION
A. Section [016600:] [_______:] Transport, handle, store, and protect products.
Only include the following paragraph if the specified system is extensive and warrants special
handling.
B.
Handle products of this section in accordance with AAMA – SFM-1.
C.
Protect finished aluminum surfaces with [wrapping] [removable protective material]. Do not use
adhesive papers or sprayed coatings which bond when exposed to sunlight or weather.
D.
1.12 PROJECT CONDITIONS
A.
1.13 ENVIRONMENTAL REQUIREMENTS
A. Section [013500:] [_______:] Environmental conditions affecting products on site.
If dry glazing methods are utilized, delete this article.
B. Do not install sealants when ambient temperature is less than [40] [_____] degrees F ([5] [_____]
degrees C) during and [48] [_____] hours after installation.
C.
1.14 WARRANTY
Improper specifying of warranty and correction period extensions may limit the statutory rights of the
owner and the ability to enforce claims under the contractor’s contractual warranty. Consult legal
counsel before editing this article.
A. Section [017000:] [_______:] Warranties.
The following paragraph extends the correction period beyond one year. An extended correction
period adds to the construction cost and may not be enforceable.
Pittco Architectural Metals, Inc.
Pittco Standard Entrance Door
October 1, 2014
081316
Aluminum Door
Page 7
B.
Correct defective work within a [one (1)] [five (5)] year period after substantial completion.
C.
Warranty: Include coverage for complete system for failure to meet specified requirements.
The following paragraph requests a manufacturer warranty; the request may not be effective as the
manufacturer is outside the jurisdiction of the Owner/Contractor contract. Coordinate this
paragraph with the Submittals at Project Closeout article. Manufacturer’s warranty for glass is
described in Section 088000.
D. Provide [five (5)] [_____] year manufacturer warranty for glazed units.
E.
PART 2 - PRODUCTS
2.1
MANUFACTURERS
The following manufacturer and their product should be used for the creation of drawing details and
door schedules. Specify the following paragraph alone or add the second paragraph indicating other
manufacturers who are also permitted to bid, providing their product conforms to or exceeds these
specification requirements.
A. Base Product: Pittco Architectural Metals, Inc., ________ - ________. Phone 800-992-7488, Fax 847593-9946, Internet web site at http://www.pittcometals.com.
Edit the following paragraphs and other descriptive specification requirements elsewhere in this
section to eliminate any conflict with the following “other” manufacturer’s products.
B.
Other acceptable manufacturers conforming to specified requirements:
C.
1.
[______________________________].
2.
[______________________________].
Substitutions: Not permitted.
D.
2.2
MATERIALS
A.
B.
C.
D.
E.
2.3
Extruded Aluminum: [ASTM B 221,] [ASTM B 221M,] 6063 alloy of [T5] [T6] temper.
Sheet Aluminum: [ASTM B 209.] [ASTM B 209M.] [_______.]
Sheet Steel: [ASTM A 653/ASTM A 653M] [_______]; galvanized in accordance with [_______].
Fasteners: [Stainless] [Galvanized] steel.
COMPONENTS
The following paragraph identifies the nominal dimensions of the primary framing members. If
performance specifying, ensure no conflict exists.
Pittco Architectural Metals, Inc.
Pittco Standard Entrance Door
October 1, 2014
081316
Aluminum Door
Page 8
A. Frame:
1.
Exposed to view Nominal Width: [2 inch (50 mm)] [1 inch 925 mm)] [].
2.
Nominal Depth: 4 1/2 inch (114 mm).
3.
Frame Assembly with [non-thermal] [thermal] design.
4.
Intermediate and Sill Horizontal Members.
5.
Mounting and Attachments from the head or sill.
6.
Flush, snap in glazing stops.
7.
Drainage Holes: Concealed internal weep drainage network.
B.
Reinforced Mullion: Extruded aluminum section with internal reinforcement of steel channel-shaped
section, tubular steel section or extruded aluminum section.
C.
Narrow Stile Doors: Specified in Section [08121.] [08123.]
1.
Leaf thickness: 1 3/4 inch (44 mm).
2.
Top Rail: 2 1/2 inch (63 mm).
3.
Bottom Rail: [3 7/16 inch (87 mm)] [ADA 9 1/2 inch (241 mm)] [______].
4.
Stiles: 2 1/16 inch (52 mm).
D. Medium Stile Doors: Specified in Section [08121.] [08123.]
E.
1.
Leaf thickness: 1 3/4 inch (44 mm).
2.
Top Rail: 3 7/16 inch (87 mm).
3.
Bottom Rail: [6 7/16 inch (164 mm)] [ADA 9 1/2 inch (241 mm)] [______] .
4.
Stiles: 3 7/16 inch (52 mm).
Wide Stile Doors: Specified in Section [08121.] [08123.]
1.
Leaf thickness: 1 3/4 inch (44 mm).
2.
Top Rail: 4 13/16 inch (122 mm).
3.
Bottom Rail: [6 7/16 inch (164 mm)] [ADA 9 1/2 (241mm) ] [______] .
4.
Stiles: 4 13/16 inch (52 mm).
Glazing Stops: Square – 1/2 inch (12 mm) for 1/4 inch (6 mm) glazing, 3/4 inch (19 mm) for 1 inch (25
mm) glazing.
F.
Door Hardware: Specified in Section [087100.] [_______.]
G.
2.4
GLASS AND GLAZING MATERIALS
Incorporate glass or plastic glazing materials by direct reference to Section 088000. The following
paragraphs only describe glass or plastic types; coordinate with a schedule in Section 088000.
A. Glass: Specified in Section 088000, of type described below:
1.
Outer Lite: [Float] [Heat-Strengthened], [Tempered], [_______], [Clear.], [Low E], [_______.]
Pittco Architectural Metals, Inc.
Pittco Standard Entrance Door
October 1, 2014
B.
081316
Aluminum Door
Page 9
2.
Space: [Dry Air.] [Argon Gas.]
3.
Inner Lite: [Float] [Heat-Strengthened], [Tempered], [_______], [Clear.], [Low E Coating on #3
Surface.] [_______.]
4.
Nominal Unit Thickness: [1] [_____] inch ([25] [_____] mm).
5.
U-Factor for center of glass: [_____] BTU/hr•ft2•degree F
Glazing Materials: Dense EPDM wedge type gasket exterior and interior, to suit applications and
achieve weather, moisture and air infiltration requirements.
C.
2.5
HARDWARE
Select one of the following three options: the first paragraph for door manufacturer’s hardware; the
second paragraph for hardware to be included in the hardware schedule or select and specify
hardware in the subsequent paragraphs.
A. Door Hardware: Weatherstripping, thresholds, [butt hinges] [offset pivots] [center pivots], {push/pull
handles] [closer] [and] [______]; manufacturer’s standard type to suit application.
[OR]
B.
Door Hardware specified in Section [087100} [______].
[OR]
C.
Hinges:
1.
[Butt Hinges (2)] [ Intermediate Butt Hinge,] [______].
2.
[Offset Pivots (2)] [Intermediate Offset Pivot] [______].
3.
[Center Pivots (2)].
Include Panic Device where required by code.
D. Panic Device:
1.
Single Door: Pittco Standard [Rim Mounted] [______].
2.
Double Door: Pittco Standard [Concealed Vertical Rod] [______] on each door leaf.
E.
Lock Cylinder: Specified in Section [087100] [______].
F.
Weatherstripping: Specified in Section [087100] [______].
G. Sill Sweep Strips: Specified in Section [087100] [______].
H. Threshold: Specified in Section [087100] [______].
I.
Closer: Specified in Section [087100] [______].
Pittco Architectural Metals, Inc.
Pittco Standard Entrance Door
October 1, 2014
081316
Aluminum Door
Page 10
J.
Latch Handle: Specified in Section [087100] [______].
K.
Lock: Specified in Section [087100] [______].
L.
Thumb Turn: Specified in Section [087100] [______].
M. Electric Strike: Specified in Section [087100] [______].
N.
2.6
FABRICATION
A. Fabricate components with minimum clearances and shim spacing around perimeter of assembly, yet
enabling installation and dynamic movement of perimeter seal.
B.
Accurately fit and secure joints and corners. Make joints flush, hairline, and weatherproof.
C.
Prepare components to receive anchor devices. Fabricate anchors.
D. Arrange fasteners and attachments to conceal from view.
E.
Prepare components with internal reinforcement for door hardware [and door operator hinge
hardware] [and electric strike hardware].
F.
Reinforce framing members for imposed loads.
G. Factory install hardware using physical hardware and templates provided. [Refer to Section 08710 for
installation and other hardware requirements.]
H. Glazing: Glass shall be [Factory Installed] [Shipped Loose] [Furnished Separately].
I.
2.7
FINISHES
The wide variety of finishes for aluminum preclude listing all of the available options; the following
paragraphs offer the commonly specified finishes, either by reference to AAMA finishes or by generic
or proprietary description. Specify the anodizing color whenever possible, as the color varies
considerably between finishes. The AAMA A41 and A44 class finishes are anodized 0.7mils (0018
mm) thick or greater (termed Architectural Class I); A41 is clear and A44 is anodized in two steps.
The A31 series is thinner and will vary between 0.4 mils (0.010 mm) and 0.7 mils (0.018 mm) (termed
Architectural Class II Clear).
A. Exposed Aluminum Surfaces: AA M10 caustic etch C21 A31, anodized to Class II Clear Color.
[OR]
B.
Exposed Aluminum Surfaces: AA M10 C21 [A41 or A44], anodized to Class I [_______] color.
[OR]
C.
Anodized Coating: [[Standard finish] [#62 Dark Bronze] [#63 Black]] [[Special order finish are available
but may require longer lead times] [#60 Light Bronze] [#61 Medium Bronze][#59 Champagne]].
[OR]
D. Finish of Exposed Aluminum shall be compliant with the performance standards set forth in AAMA
Specification 2604, High Performance Organic Coatings on Aluminum.
Pittco Architectural Metals, Inc.
Pittco Standard Entrance Door
October 1, 2014
081316
Aluminum Door
Page 11
E.
Type: Factory Applied, High Performance, 50% Polyvinylidene Fluoride (PVDF) Coating formulated by a
licensed paint manufacturer, and applied by Paint Manufacturer’s Warranty-Approved Applicator.
F.
Pretreatment: Applicator to pre-treat the aluminum with solutions to remove organic and inorganic
surface soils, remove residual oxides, followed by a Chrome Phosphate or Chromate Coating to ensure
adhesion to the aluminum.
G. Color: {Specifier to insert color code here, e.g., UC 40577 (Duranar Black)}.
[OR]
H. Finish of Exposed Aluminum shall be compliant with the performance standards set forth in AAMA
Specification 2605, Superior Performing Organic Coatings on Aluminum.
I.
Type: Factory Applied, High Performance, 70% Polyvinylidene Fluoride (PVDF) Coating formulated by a
licensed paint manufacturer, and applied by Paint Manufacturer’s Warranty-Approved Applicator.
J.
Pretreatment: Applicator to pre-treat the aluminum with solutions to remove organic and inorganic
surface soils, remove residual oxides, followed by a Chrome Phosphate or Chromate Coating to ensure
adhesion to the aluminum.
K.
Color: {Specifier to insert color code here, e.g., UC 40577 (Duranar Black)}.
L.
Apply [one coat] [[____] coats] of bituminous paint to concealed aluminum [and steel] surfaces in
contact with cementitious or dissimilar materials.
M. Concealed Steel Items: [Stainless Steel.] [Galvanized Steel to ASTM A 123/A 123M] to [2.0] [_____]
oz/ft ([610 [_____] g/m).] [Primed with manufacturer’s shop coat primer.]
N. Extent of Finish:
1.
Apply factory coating to all surfaces exposed at complete assemblies.
2.
Apply touch-up materials for field application to minor damage of factory applied finish.
Include the following paragraph if interior and exterior colors differ.
O. Schedule of Differing Finish Colors:
1.
Exterior Surfaces: [________] color.
2.
Interior Surfaces: [________] color.
P.
PART 3 - EXECUTION
3.1
EXAMINATION
A. Section [017100:] [_______:] Verification of existing conditions before starting work.
B.
Verify dimensions, tolerances, and method of attachment with other work.
C.
Verify wall openings and adjoining air and vapor seal materials are ready to receive work of this section.
D.
3.2
INSTALLATION
Pittco Architectural Metals, Inc.
Pittco Standard Entrance Door
October 1, 2014
081316
Aluminum Door
Page 12
A. Attach to structure to permit sufficient adjustment to accommodate construction tolerances and other
irregularities.
B.
Provide alignment attachments and shims to permanently fasten system to building structure.
C.
Align assembly plumb and level, free of warp or twist. Maintain assembly dimensional tolerances,
aligning with adjacent work.
D. Set thresholds in bead of [silicone] [urethane] [butyl] [______] sealant and secure to structure.
E.
Install hardware using physical hardware and templates provided. [Refer to Section 087100 for
installation requirements.]
F.
Install glass in accordance with Section 088000, utilizing glazing method required to achieve
performance criteria.
The following paragraph indicates installation of perimeter sealant materials as part of this section
and references Section 079000 for materials and application.
G. Install Perimeter Sealant:
1.
Utilizing method required to achieve performance criteria.
2.
Use [silicone] [urethane] [______] sealant, required backing materials, and recommended
installation procedures.
3.
According to the requirements of Section 079000.
H.
3.3
ERECTION TOLERANCES
A. Section [014000:] [_______:] Tolerances.
B.
Maximum Variation from Plumb: 1/16 inch every 3 feet (1.5 mm/m) non-cumulative or 1/16 inch per
10 feet (1.5 mm/3 m), whichever is less
C.
Maximum Misalignment of Two Adjoining Members Abutting in Plane: 1/32 inch (0.8 mm).
D.
3.4
FIELD QUALITY CONTROL
Only include this article if special field inspection services will be involved.
A. Section [017500:] [_______:] Field [inspection,] [testing,] [adjusting,] [and] [balancing].
B.
Inspection will monitor quality of installation and glazing.
C.
3.5
ADJUSTING
A. Section [017500:] [_______:] Adjusting installed work.
B.
C.
Adjust operating hardware [and sash] for smooth operation.
Pittco Architectural Metals, Inc.
Pittco Standard Entrance Door
October 1, 2014
3.6 CLEANING
081316
Aluminum Door
Page 13
A. Section [017400:] [_______:] Cleaning installed work.
B.
Remove protective material from pre-finished aluminum surfaces.
C.
Wash down surfaces with a solution of mild detergent in warm water, applied with soft, clean wiping
cloths. Take care to remove dirt from corners. Wipe surfaces clean.
D. Remove excess sealant employing a method acceptable to sealant manufacturer and finish supplier.
E.
3.7
PROTECTION OF FINISHED WORK
A. Section [017600:] [_______:] Protecting installed work.
B.
Protect finished work from damage.
C.
END OF SECTION