interval table Field Description Field Name Type [size] Details Foreign Key and 1/3 text [9] of Primary Key About CEDS Fields (Mandatory) The Well record must exist to be available/selected WPI_WEL_NUM from this list to complete and save the Interval record. dHFeatureClass Well Number WELLNO Boreline Interval Type (Mandatory) Select H for hole, 1/3 of C for casing, G NTERVL_TYP text [1] Primary for Grout/Gravel WPI_INTERVAL_TYP Key (describe in comments) or S for screen. Boreline Interval Number Interval numbers are assigned sequentially with 1 being the interval for each 1/3 of type nearest to NTERVL_NUM text [3] Primary the surface. WPI_INTERVAL_NUM Key Interval numbers for a well do not repeat for an interval type. For example, a well with two screen Boreline intervals (one at bottom) would have at least C1, C2, S1 and S2 intervals. Top Interval Bottom Interval Diameter Screen Size Comments number n/a [double] The top of the interval in feet below ground surface. WPI_INTERVAL_TOP Boreline NTERVL_BOT number n/a [double] The bottom of the interval in feet below ground surface. WPI_INTERVAL_BOT Boreline DIAMETER number n/a [double] The diameter of the interval in inches. WPI_DIAMETER Boreline number n/a [double] For screen intervals only – enter 20 for WPI_SCREEN_SIZE 0.020 slot, 30 for 0.030 slot, etc. Boreline memo Enter free form comments about the interval record including your initials and WPI_COMMENTS the date of entry. Screen intervals should include documentation of the source for the Boreline NTERVL_TOP SCREEN_SIZ INT_COMNT n/a aquifer pick. Grout/Gravel intervals should specify type. Casing intervals should state casing material where specified. Columbia Aquifer Upper YorktownEastover Aquifer aq10 aq9u boolean n/a Check if screen interval intersects the Columbia aquifer. This indication will WPI_AQ10 represent OGWC aquifer pick for dhydro management system. boolean n/a Check if screen interval intersects the Upper Yorktown aquifer. The separation of the Yorktown WPI_AQ9U aquifer into three units is primarily for wells on the Eastern Shore. If a mainland well screen interval is simply Boreline Boreline specified as “YorktownEastover” then all three Yorktown aquifer boxes should be checked. This indication will represent OGWC aquifer pick for dhydro management system. Middle YorktownEastover Aquifer aq9m boolean n/a Check if screen interval intersects the Middle Yorktown aquifer. The separation of the Yorktown aquifer into three units is primarily for wells on the WPI_AQ9M Eastern Shore. If a mainland well screen interval is simply specified as “YorktownEastover” then all three Yorktown Boreline aquifer boxes should be checked. This indication will represent OGWC aquifer pick for dhydro management system. Lower YorktownEastover Aquifer aq9l boolean n/a Check if screen interval intersects the Lower Yorktown aquifer. The separation of the Yorktown aquifer into three units is primarily for wells on the Eastern Shore. If a mainland well WPI_AQ9L screen interval is simply specified as “YorktownEastover” then all three Yorktown aquifer boxes should be checked. This indication will represent OGWC Boreline aquifer pick for dhydro management system. St. Mary’sChoptank Aquifer aq8 ChickahominyPiney Point aq7 Aquifer Aquia Aquifer aq6 boolean n/a Check if screen interval intersects the St. Mary’sChoptank aquifer. This indication will WPI_AQ8 represent OGWC aquifer pick for dhydro management system. Boreline boolean n/a Check if screen interval intersects the ChickahominyPiney Point aquifer. This WPI_AQ7 indication will represent OGWC aquifer pick for dhydro management system. Boreline boolean n/a Check if screen interval intersects WPI_AQ6 the Aquia aquifer. Boreline Pee Dee Aquifer aq5 Virginia Beach aq4 Aquifer boolean n/a Check if screen interval intersects the Pee Dee aquifer. This indication will WPI_AQ5 represent OGWC aquifer pick for dhydro management system. Boreline boolean n/a Check if screen interval intersects the Virginia Beach aquifer. This indication WPI_AQ4 will represent OGWC aquifer pick for dhydro management system. Boreline Boreline Boreline BrightseatUpper Potomac Aquifer aq3 boolean n/a Check if screen interval intersects the Upper Potomac aquifer. This indication WPI_AQ3 will represent OGWC aquifer pick for dhydro management system. Middle Potomac aq2 boolean n/a Check if screen WPI_AQ2 interval intersects Aquifer Lower Potomac Aquifer Last Update Last Update By the Middle Potomac aquifer. This indication will represent OGWC aquifer pick for dhydro management system. aq1 iupdate iupdateby Check if screen interval intersects the Lower Potomac aquifer. This indication WPI_AQ1 will represent OGWC aquifer pick for dhydro management system. Boreline read only The most recent date changes were saved to the record. Boreline n/a The Username of the person who last saved changes to the record. Boreline boolean n/a date text [25]