CODE COMPLIANCE REVIEW Building Code of The City Of New York Campus/Facility: Client: (Address) Building Name(s): Building Numbers: Project Title: Architect/Engineer: JDE # Estimated Project Cost: Code Enforcement Jurisdiction: DASNY Occupancy Classification(s): A: High Hazard B-1: Storage (Moderate Hazard) B-2: Storage (Low Hazard) C: Mercantile D-1: Industrial (Moderate Hazard) D-2: Industrial (Low Hazard) E: Business F-1a: Assembly (Theater) F-1b: F-2: F-3: F-4: G: H-1: H-2: J-1: Other: Assembly (Churches, Concert Halls) Assembly (Outdoors) Assembly (Museums) Assembly (Restaurants) Education Institutional (Restrained) Institutional (Incapacitated) Residential (Hotels) Variance Requested: J-2: J-2: J-3: K: Yes No Residential (Apartment Houses) Three Family Dwelling Residential (1 & 2 Family Houses) Miscellaneous Other: Construction Classification: (Code Section 27-269) I-A: I-B: I-C: I-D: Non- Combustible 4 Hour Protected 3 Hour Protected 2 Hour Protected 1 Hour Protected Project Type: Check all that apply. Work Involved: Check all that apply. II-A: II-B: II-C: II-D: II-E: Combustible Heavy Timber Protected Wood Joist Unprotected Wood Joist Protected Wood Frame Unprotected Wood Frame New Building Repair Renovation Alteration General Construction Roofing Asbestos Abatement/Environmental Fire Alarm 1: 2: 3: 4: 5 6: Old Code Fireproof Structures Fire-protected Structures Non-fireproofed Structures Wood Frame Structures Metal Structures Heavy Timber Structures Reconstruction Change of Occupancy Addition Historic Building Structural Mechanical Plumbing Electrical Site Work Sprinkler Elevators Other A/E DESIGN ANALYSIS AND CODE CHECKLIST LEGEND: FPC: Fire Prevention Code, NA: Not Applicable, NR: Not Required, NP: Not Permitted RS: Ref. Standards, P: Plumbing No. Topic Code Section Required Actual Comment 1 Energy Conservation: 27-122 Heating/Combustion Equip. 27-848.04(e) 2 Occupancy Classification: 27-237 3 Building Access: 27-291 Fire Department Access 27-291 Facilities People Having 27-292.1 (RS4-6 Physical Disabilities ANSI A117.1-1986) 4 Area Limitations: 27-301 Height Limitations 27-305 General Projection 27-307 Rev. 2005 Page 1 5 6 7 8 9 10 11 Limitations Prevention of Exterior Fire Spread: Protection of Opening Parapet Walls Roof Coverings Finishes: Exterior Interior Finished Flooring And Floor Covering Fire Protection Construction Requirements: Fire Resistance Requirements Protection of Structural Members Elevators Lintels Ceilings Fire Retardant Treated Wood Opening Protectives Slow Burning Plastic Prevention of Interior Fire Spread: Fire Divisions Fire Separation Shaft/Stair Venting Firestopping Elevators & Escalators (Vestibules) Stairs (Impact Resistance – Group E Spaces) Elevator Lobby (Impact Resistance – Group E Spaces) Means of Egress: Travel Distance Number (One exit permitted) Dead End Corridor Corridor Width Smoke Stops Door Width Enclosure Panic Hardware Supplemental Vertical Exits Interior Stairs Handrails Openings in Stairs Photoluminescent Material Exit Signs Exterior Stairs Ceiling Height Requirements: Corridors Exit Passageway Doors Interior Stairs Atriums: Construction Enclosures Fire Protection Means of Egress Smoke Control Rev. 2005 27-331 27-331(b) 27-333 27-337 27-331 27-348 27-351 27-318 27-323 27-324 27-325 27-326 27-327 27-328 27-329 27-330 27-339 27-340 27-341 27-344 27-345 27-353.1 27-353.2 27-375(i)(6) 27-987(c)(2) 27-354 27-360 27-365 27-366 27-369(d) 27-369(a) Table 6-1 27-369(c) 27-371(e) Table 6-1 27-271 Table 3-4 27-371(k) 27-374 27-375 27-375(f) 27-375(i) 27-383(b) 27-389 27-376 27-368 27-369(b) 27-370(c) 27-371(f) 27-375(c) 27-521.1 27-521.3 27-521.3 27-521.4 27-521.5 27.521.8 Page 2 12 13 14 15 16 17 18 19 20 21 Fire Protection Special Hazards/Systems: Public Assembly 27-522 Emergency Ventilation 27-546(b)(8) (Places of Assembly). Kitchen Exhaust Hood 27-777(d) Fan Shutdown 27-777(1) Elevator Emergency 27-989 Operation (Elevator in Readiness) List Other Special Systems Below and Provide Required Information. Structural Design 27-580 Requirements: Design Loads 27-550 Floor 27-557 Snow 27-561(a)(3) Wind 27-569 Storm Drainage P110.4 Foundation 27-652 Glass Panels: 27-643 Standards For Light: Natural 27-732 Artificial 27-735 Mechanical Ventilation, Air 27-771 Conditioning, and Refrigeration Systems: General Requirements 27-776 Construction 27-777 Smoke Control Requirements 27-777(1) Heating and Combustion 27-787 Equipment: Enclosure 27-419 Prohibited Locations 27-792 Air Supply 27-807 Safety and relief valves RS16 - P107.26(e) Chimneys / Flues / Gas 27-849 Vents: Outlet Locations 27-859 Prohibited Use 27-861(d) Plumbing: 27-896 Fixtures RS16 - P104.0 Materials RS16 - P102 Hot Water Supply RS16 - P107.26 Fire Protection General: 27-923 Coordinated Fire Safety 27-929.1 (Retroactive Requirements For Office Buildings 100’ Or More In Height.) Standpipe System 27-932 Siamese Connections 27-940 Yard Hydrant System 27-948 Sprinkler System 27-954 Fire Alarm System 27-968 Automatic Vents 27-972(f)(9) Smoke Detection System 27-978 Carbon Monoxide Detectors 27-981.2 Electrical: 27-3024 - 2002 NEC Emergency Power 27-396.4 Fire Pump 27-396.4 Elevator 27-396.4 Lighting 27-396.4 Emergency Lighting 27-542 Exit Lights 27-540 Rev. 2005 Page 3 Inspection Agency 27-3018 ADDITIONAL COMMENTS: Rev. 2005 Page 4