SAT 450 INTRODUCTION SAT 450 fully automatic random access analyzer improved cost efficiency, reduced rerun manual handling while delivering high quality results. TECHNICAL CHARACTERISTICS and SPECIFICATIONS DESCRIPTION: Fully Automatic, random access, continuous loading, benchtop open analyzer for Clinical Chemistry and Immunoturbidimetric assays. ASSAY TIPE: End point, Kinetic, Differential, Fixed time, Bichromatic and Immunoturbidimetric; up to 999 tests, all user programmable. ON LINE REAGENTS: Up to 72 reagents can be loaded into the refrigerated compartment and distributed on: - 4 removable racks with 16 position each (25 ml containers) - 8 extra positions for 25 ml containers SAMPLES LOADING: - 4 universal racks for continuous loading of samples, calibrators and controls - each rack contains up to 15 cups and/or tubes 10-16 mm diam., 40-100 mm height - 8 extra positions for urgent samples, calibrators and controls Urgent sample execution is allowed at any time TRHOUGHPUT: Up to 450 test/hour including I.S.E. module WORKING TEMPERATURE: 37 °C READING SYSTEM: - Direct reading, dual channel photometer - 200 µl minimum reading volume Wavelenght: 9 narrow band interferential filters Light Source: halogen lamp 6V/10W Optical Path: 6 mm. Linear Range: 0.0001 ÷ 4.200 Abs High Resolution: 0.0001 Abs SAMPLING ARM: One mechanical arm performs all sampling operation with: - capacitive liquid level sensing - reagent pre warming at 37 °C - automatic probe washing - sample volume range 2.0-50 µl (0.25 µl increment) - reagent 1 volume range 3.0-330 µl (1 µl increment) - reagent 2 volume range 3.0-330 µl (1 µl increment) - reagent 3 volume range 3.0-330 µl (1 µl increment) - sample predilution - sample rerun with or without dilution REACTION PLATE Holds 80 cuvettes divided into 4 racks with 20 cuvettes each and performs the following operations: - automatic cuvette washing - continuous monitoring of cuvette quality - incubation temperature control at 37 °C +/- 0.3 OPTIONS - ISE Module for Na+, K+, Cl- - Positive Barcode readers for reagents and sample (code 128, codabar, code 2 of 5 interleaved, code 39) INSTALLATION REQUIREMENTS - Power Supply 100-230 VAC, 47-63 Hz - Electric Consumption 386 Watt DIMENSIONS, WEIGHT & ENVIRONMENT Analytical Module - Height: 50 cm - Width: 70 cm - Lenght: 90 cm - Weight: 35 Kg Room Temperature: 18-30 °C Relative Humidity: 20% - 85% VEGASYS (NEW) INTRODUCTION The VEGASYS is an Open, Fully Automatic, Counter Top, Batch Analyzer for VET and Clinical Laboratory. It runs immunoturbidimetric, clinical chemistry analyses using single or double reagent methodologies. TECHNICAL CHARACTERISTICS and SPECIFICATIONS SAMPLES AND REAGENTS The VEGASYS holds 40 samples (four segments with 10 sample cups each) plus 1 segment for 6 Standards and 2 Controls. Removable reagent tray with 18 reagent containers (25 ml. each). OPERATION The VEGASYS runs all clinical chemistry and immnoturbidimetric tests: End Points, Fixed Time, Kinetics, Bichromatics and Differential methods with or without Reagent Blank correction, against Factor or Standard. Samples can be loaded by single test or Profile. It is programmed for 7 different calculation algorithms for non-linear analysis, automatic flagging for system and results anomalies, abnormal values, enzymes substrate depletion, Rbl out of range. OPEN SYSTEM Wide choice of methods and reagents. The User can programme more than 300 clinical chemistry and immunoturbidimetric applications. THROUGHPUT Up to 200 colorimetric tests/hr. PHOTOMETER Multi wavelength photometer with narrow band interference filters, 340, 405, 492, 510, 546, 578, 620 nm. Halogen lamp. Linear range up 2.5 OD – resolution of 0.001 OD. Micro- flow-cell, 50 µl total volume, temperature controlled at 37 °C ± 0.1°C by Peltier effect. SAMPLING High precision Diluter Module.Sample aspiration from 3 to 99 µl with 1 µl increments. Reagent dispensing from 5 µl to 500 µl. Minimum reaction volume 450 µl. REACTION TRAY 114 disposable reaction cells (6 segments of 19 cells each) temperature controlled at 37 °C. COMPUTER (OPTIONAL) Minimum requirements: • Pentium III, 300 Mhz • RAM Memory: 256 Mb • Hard Disk : 20 Gb • Monitor: SVGA 15” color – Resolution: 1024x768 • Printer: windows compatible • Communication: RS232 USB 1.1/2.0 Full Speed • Operative System: Windows XP SOFTWARE MAIN FEATURES The VEGASYS software runs Under Windows XP and manages, the following functions: • Unlimited work list • Historical patient and calibration database • Quality control • Visualization and print-out of graphs (Levey – Jennings) • Methods programming (open system) • Management of unwanted sequences • Database for reagents, standards and controls • Sample pre-dilution • Normal Values for Human and Vet testing are user’s definable • Samples entry for serum/urine and pets • Multipoint calibration curves and relative graphs • Bidirectional Interface with Host Computer • Auto – Diagnosis program. POWER REQUIREMENT 110 – 240 VAC - 47/63 Hz - 180 W DIMENSION & WEIGHT Height. 32 cmWidth: 45 cmLength: 50 cmWeight: 22 Kg NEPHYS (NEW) INTRODUCTION Designed for clinical laboratories, the NEPHYS™ is an open, random access, counter-top, fully automated ImmunoNephelometric system. TECHNICAL CHARACTERISTICS and SPECIFICATIONS METHODOLOGIES ImmunoNephelometric fixed-time, end point, kinetic and differential 300+ different methods can be programmed. OPERATIVE MODE Profile, batch, selective, STAT THROUGHPUT 180 tests/hr SAMPLE LOADING Continuous loading on 4 separate racks, 8 positions each. STAT samples can be placed at any time in any of the 4 racks and be run immediately SAMPLE CONTAINERS Primary tubes (diameter from 8 to 16 mm; height up to 100 mm). Cups from 1 ml to 4 ml SAMPLING Sample volume: 2.0 to 99 microliters (1 μ increments) Reagent volume: 3.0 to 499 microliters (1 μ increments)Capacitive leve) sensorReagent preheating to 37° CAutomatic sample probe washing (internai and external)Probe wash cycle is operator programmable REAGENTS 24 positions available for reagent containers STANDARDS AND CONTROLS Up to 12 positions MINIMUM REACTION VOLUME 250 microliters READING CUVETTES 120 semi - disposable, optic grade cuvettes divided among 6 racks (20 each) OPTIC MODULE 2 interferential filters: 630 and 660 nm (other wavelengths available on request) FWHM: 10 nm _+ 2 nm 6V-10W halogen bulb Optic path length: 6mm Light scattering: - 630 nm Latex Tests - 660 nm Antisera REACTION TEMPERATURE Air bath at 37° C + 0.2 COMPUTER & SOFTWARE SPECIFICATIONS (Minimum specs) Pentium III, 500 MHz RAM Memory: 256 Mb Hard disk: 20 Gb Monitor SVGA 15" color Printer: Ink Jet Communication: RS232, USB Operative System: WINDOWS XP OPTIONAL ACCESSORIES - Bar code reader (reagents and samples) - Computer table - Instrument table POWER REQUIREMENTS - 90 - 250 VAC - 47/63 Hz - 300 W WATER CONSUMPTION About 3 ml/test DIMENSIONS & WEIGHT - Height: 53 cm - Width: 57 cm - Length: 75 cm - Weight: 35 kg OPERATING ENVIRONMENT REQUIREMENTS Room temperature: 18 to 32° C Relative humidity: 20 to 85% ELLIPSE INTRODUCTION Fully automatic random access benchtop Analyzer for Clinical Chemestries and Immunoturbidimetric assays. TECHNICAL CHARACTERISTICS and SPECIFICATIONS SYSTEM DESCRIPTION: open, random access, counter top instrument for chemical and immunoturbidimetric clinical analysis. METHODOLOGIES: kinetic, fixed time, end point, immunoturbidimetric, differential. 300+ different methods can be programmed. OPERATIVE MODE: profile, batch, stat. THROUGHPUT: 130 tests/hr SAMPLE LOADING: continuos loading on 4 separate racks, 8 positions each. stat samples can be placed at any time in any of the 4 racks and be run immediately. SAMPLE CONTAINERS: primary tubes (diameter from 6 to 16 mm; height up to 100 mm). cups from 1 ml to 4 ml. SAMPLING: · Sample volume: 2 to 99 µl (1 µl increments) · Reagent volume: 25 to 400 µl (1 µl increments) · Capacity level sensor · Reagent preheating to 37° C · Automatic sample probe washing (internal and external) · Probe wash cycle is operator programmable. REAGENTS: 24 positions available for reagent containers. STANDARDS AND CONTROLS: Up to 12 positions. MINIMUM REACTION VOLUME: 200 µl. READING CUVETTES: 120 semi-disposable, optic grade cuvettes divided among 6 racks (20 each). OPTIC MODULE: . double beam · 8 interferential filters + 1 position available for an optional filter · narrow band filters 340, 380, 405, 492, 510, 546, 578, 620 (± 2) · fwhm: 10nm ± 2nm · 6v - 10w halogen bulb · optic path lenght: 6 mm · resolution: 0,0005 abs · linearity: up to 3,500 abs REACTION TEMPERATURE: Air bath at 37° C ±0.2. COMPUTER & SOFTWARE SPECIFICATIONS: Minimum specs: · Pentium III, 500 Mhz · RAM Memory: 256 Mb · Hard Disk: 20 Gb · Monitor: SVGA 15" color · Printer: Ink jet · Communication: RS232, USB 1.1/2.0 · Operative System: Windows XP. OPTIONAL ACCESSORIES: BARCODE READER (SAMPLES) POWER REQUIREMENTS: · 90 - 230 VAC · 47/63 Hz · 300 W WATER CONSUPTION: About 3 ml/test DIMENSIONS & WEIGHT: · Height:53 cm · Width: 57 cm · Lenght: 75 cm · Weight: 43 Kg OPERATING ENVIRONMENT REQUIREMENTS: Room temperature: 18 to 32° C Relative humidity: 20 to 85% LIASYS INTRODUCTION LIASYS is a fully automatic random access, continuos loading, easy access benchtop Clinical Chemistry and Immunoturbidimetric analyzer. The instrument features primary tubes sampling, capacitive liquid level sensing, positive identification of the samples (optional), and module for ISE (optional). It is therefore suitable to perform the daily routine of low/medium - sized laboratories in a entirely safe and reliable way, providing flexible and cost effecive solutions. The LIASYS multitasking and user friendly software, running under Windows 98, enhances the system's potential and performance. TECHNICAL CHARACTERISTICS and SPECIFICATIONS DESCRIPTION: Fully automatic,random access, continuous loading, benchtop analyzer for Clinical Chemistry and Immunoturbidimetric assays. ASSAY TIPE: End point, Kinetic, Differential, Bichromatic and Immunoturbidimetric; up to 999 tests, all user programmable. ON LINE REAGENTS: 4 racks are provided to hold up to 33 reagents that are divided as follows: - 2 racks cooled by Peltier cells holding up to 20 reagents - 2 racks for 13 reagent positions and 14 standards and controls at room temperature - 2 additional positions for diluents. SAMPLES LOADING: 5 racks for continuous loading of samples split in: - 64 positions for routine samples - 14 positions for STAT samples PRIMARY TUBES SIZE: max 16 mm x 100 mm (height) STAT SAMPLES PROCESSING: Allowed at any time THROUGHPUT: Up to 333 test/hour with ISE (200 without ISE) WORKING TEMPERATURE: 37 °C READING SYSTEM: Direct photometry MINIMUM REACTION VOLUME: 300 µl OPTICS SYSTEM: - Photometer: multi - wavelenght dual channel optic - Wavelenght: 8 narrow band interferential filters - Light Source: halogen lamp 6V/10W - Optical Path: 10 mm. - Linear Range: 0.001 ÷ 2.500 Abs - Resolution: 0.0001 Abs SAMPLING ARM: One mechanical arm performs all sampling operation with: - capacitive liquid level sensing