Manuale Kit Ibrido in inglese da completare

advertisement
FV: 2.94 kWp - Thermal: x 4/5
DESCRIPTION OF SYSTEM:
The modules are connected in series with each other so as to form two strings that will be
connected to the one inverter of the implant that has the function of converting the direct
current produced by the modules into alternating current to be fed into the electricity grid.
N N strings modules per string Model Model Inverter Modules
HYBRID PV generator 1 6 BRP6360064 PVI-3.0-245
PV generator 1 6 BRP6360064-245
SYSTEM DIAGRAM:
PARTS LIST:
description quantity
PV module 245 poles 12
inverter PVI-3.0 1
connection set Tyco 2
fixing structure of tiles with threaded rod
(Vertical module) 1
thermal hybrid module 6
set of intermediate link 5
set of connection terminal 1
10lt antifreeze concentrate 1
circulation unit 1 unit on top + 1
fittings 1
expansion vessel 18lt 1
mono glass-lined tank 200lt 1
FV: 5.88 kWp - Thermal: x 6/7
DESCRIPTION OF SYSTEM:
The modules are connected in series with each other so as to form three strings that will
be connected to the inverter 2 of the plant that have the function of converting the direct
current produced by the modules into alternating current to be fed into the electricity grid.
N N strings modules per string Model Model Inverter Modules
HYBRID PV generator 1 6 BRP6360064 PVI-3.0-245
PV generator 1 6 BRP6360064-245
PV generator b 1 12 BRP6360064 PVI-3.0-245
SYSTEM DIAGRAM:
PARTS LIST:
description quantity
PV module 245-pin 24
inverter PVI-3.0 2
connection set Tyco 3
fixing structure of tiles with threaded rod
(Vertical module) 1
thermal hybrid module 6
set of intermediate link 5
set of connection terminal 1
10lt antifreeze concentrate 1
circulation unit 1 unit on top + 1
fittings 1
expansion vessel 18lt 1
mono glass-lined tank 300lt 1
FV: 9.80 kWp - Thermal: x 8/10
DESCRIPTION OF SYSTEM:
The modules are connected in series with each other so as to form 4 strings that will be
connected to the inverter 2 of the plant that have the function of converting the direct
current produced by the modules into alternating current to be fed into the electricity grid.
N N strings modules per string Model Model Inverter Modules
HYBRID PV generator 1 8 BRP6360064 PVI-245-5000
PV generator at 1-245 12 BRP6360064
PV generator b 2 10 BRP6360064 PVI-245-5000
SYSTEM DIAGRAM:
PARTS LIST:
description quantity
PV module poly 245 40
inverter PVI-5000 2
connection set Tyco 4
fixing structure of tiles with threaded rod
(Vertical module) 1
hybrid thermal module 8
set of 6 intermediate link
set of terminal connection 2
10lt antifreeze concentrate 1
circulation unit 1 unit on top + 1
fittings 1
expansion vessel 18lt 1
mono glass-lined tank 400lt 1
Terms of Sale
Delivery: 30 days into our warehouse
Transportation: cost
Packaging: cartons on pallets (to be charged or to make)
VAT: 10% - 21% (in accordance with DPR633/72 et seq. Changes)
Discount: Net Price
Payment: 30% BB order - 70% notice of readiness for shipment
Conditions of Guarantee
PV modules: Product: 11 years from delivery
Power: 5 years on the yield to 95%;
10 years on the yield to 90%;
25-year yield to 80%
Thermal Modules: Product: 5 years from delivery
String Inverters: 5 years, with possibility of extension
Storage tanks: 5 years
Other components: as required by law
Notes:
The above prices are exclusive of VAT and do not include shipping charges, expenses for
loading and unloading goods, charges for authorizations required for its development,
security charges, masonry and civil charges for coverage insurance material in the
pipeline, design, installation, testing.
The electrical installation must be approved by a qualified technician. The property may be
subject to change due to higher specifications and plant layout. The power could be
changed by varying the electrical configuration with the drive available.