GC-MSD Introducing the new 7890B/5977A Badr Astiphan GCMS Product Sales Specialist 1-866-524-7936 302-290-5631 cell badr_astiphan@agilent.com 1 Agilent Confidential January 8, 2013 We are First in GC Continuously innovating 7000 GC Triple Quad Units Installed >250,000 GC >60,000 MS 7200 GC QTOF Low Thermal Mass Technology Multi-Mode Inlet Retention Time Locking 2nd Gen Linear Electron Capture Detector Electronic Pneumatic Control 6890 GC Capillary Flow Technology Inert MS Ion Source Hyperbolic Gold Quad 5970 MSD Fused Silica Capillary Column 5890 GC AutoInjection 5840 GC Microprocessor Control 2 5880 GC Agilent Confidential January 8, 2013 7890A/5975C GC/MSD: The Most Popular GC/MS in the World The industry standard GCMS Over 20,000 5975 systems since 2005 3 Agilent Confidential January 8, 2013 Agilent 5977 MSD 4 Agilent Confidential January 8, 2013 Proven Technologies Improving the Industry Standards for GC/SQ Gold Quartz Quad Triple Axis Detector High Temperature Inert Source Unique Entrance Lens Design All of 5975’s features also built in 5977, such as “Gold Quad”, SIM/Scan, Gain tuning, Triple-Axis Detector, Trace Ion Detection, Auto CI, etc.. 5 Agilent Confidential January 8, 2013 High Temperature Ion Source 350°C 325°C Solid inert material – not a coating – Not damaged by multiple cleanings Programmable to 350ºC Improved response for many compounds – More robust operation for “dirty” samples – Better response for “sticky” compounds – Sharper peaks for high boilers (late eluters) 300°C 275°C 230°C Polyaromatic Hydrocarbon (PAH) … more performance for a wide range of applications 6 Agilent Confidential January 8, 2013 Unique Entrance Lens Eliminates Pre-filter New, improved lens 7 Agilent Confidential January 8, 2013 Unique Entrance Lens Eliminates Pre-filter Fringe fields 8 Agilent Confidential January 8, 2013 Quartz – Gold – Hyperbolic and Beautiful! Why quartz? Much more than just a beautiful piece of glass – Low coefficient of linear expansion (expansivity; α) • dL = α L0 dt [t = ºC; dL = change in length (m); L0 = length at 0 ºC] Why gold? – Inert material with excellent electrical properties for high voltage Why hyperbolic? – Ideal electrical field is generated by hyperbolic surfaces (NOT ROUND) 9 Round Quad Agilent Confidential January 8, 2013 Triple-Axis Detector With a combination of three axes and appropriate shielding, noise from secondary particles can be reduced to a minimum Offset Z Y ion beam X 10 Agilent Confidential January 8, 2013 Triple Channel EM Exit of the triple channels Triple channels improve signal amplification – Lower initial EM voltage required Triple channels increase life – Lower cost of operation Collector removed to show exit passages Collector 11 Agilent Confidential January 8, 2013 Expanded Capabilities: 7890B/5977A Improving the Industry Standards for GC/SQ Save Time & Energy Higher Ion Count •Sequence Scheduler • Extractor EI source • Increased ion count • S/N > 1500:1 • IDL < 10 fg (industry first) • Improved thermal profile • “Standby” post run • “Ready to run” from standby • “Bake Mode” as needed • Factory backflush option • Fast Vent capability • DS42i rough pump“standby” power reduction Better Vacuum by Agilent Pump • New Agilent V304 Turbo • TwisTorr Faster Scanning • 20,000 u/s • But never equal to the 7200 Q- • Molecular Drag technology • Improved pumping light gases • H2 (220 L/s); He (255 L/s) • Agilent Floating Suspension • Longer life • Quiet operation TOF speed or ‘scan’ sensitivity Safety/Protection • Vacuum failure Shut off gas (He or H2) 7890B GC “Direct Communications Features • EMF, calculator, etc. 12 Agilent Confidential January 8, 2013 New Extractor Ion Source for 5977 Why the Extractor EI Source? Increase in ion count True increase in sensitivity Better trace level precision Lower IDL and MDL Proven sensitivity increase demonstrated with over 1500 7000 Series GC/TQ! Page 13 Agilent Confidential January 8, 2013 Comparison of Inert and Extractor Ion Source Repeller (Push) Ionization area Ions Drawout Plate Extractor Lens (Pull) Ion Focus Lens Entrance Lens Mass Filter Inert Ion Source Extractor Source More ions to Mass Filter Agilent Confidential Page 14 January 8, 2013 Extractor Source “Etune” Sensitivity Increase Blue – Extractor 40ppb solution (SVOC) Red – Standard 40ppb solution (SVOC) 15 Agilent Confidential January 6, 2013 More improvements on 5977’s Extractor Ion Source: Improved Thermal Profile Why is this important? Better performance of high boilers i.e. PAH even at lower concentration! Good repeatability of PAH even at the trace level (5ppb)!! 10 Injections 80 min analysis Improvement for better Mass Spectrometer of Gas Chromatograph Page 16 January 15, 2013 Comparing repeatability of 80min Method 5975 result Two years ago 5977 result 5977 result 200ppb PAH 5ppb PAH Phthalates analysis with 5977 GC/MSD Page 17 Oct 2012 Key features of “Direct Communication” between 7890B and 5977A Sleep/Wake mode • Sleep mode saves power (320W 190W) Lower lab operating cost Safety Control • If 5977A MSD pump fail, 7890B will shut off the gas supply Helium carrier gas : gas waste is eliminated Hydrogen carrier gas: risk of explosion is reduced Cool Down MSD Faster (FastVent) • When MSD Vent Cycle started, GC will cool down MSD analyzer at the optimum gas flow to MSD. 40% faster when cooling down from 280C to 100C (< 25 min) Page 18 Agilent Confidential January 8, 2013 Saving Energy and Time 400 350 300 250 200 150 100 50 0 Power saved Time saved using Fast Vent 250 200 Source Temp Power( VA) Power Consumption 5977 150 100 Normal Op Standby Fast Vent 50 Vent 0 0 4 6 Time(min) 19 7 15 20 23 30 35 40 Time saved Better HW Features: Agilent Turbo Pump (V304) Innovation for: •Higher pumping performance • especially for He and H2 •High reliability • lower cost of operation Agilent Quality Standard TwisTorr 304 FS Press release : http://www.agilent.com/about/newsroom/presrel/2012/19dec-ca12077.html Page 20 Agilent Confidential January 8, 2013 TwisTorr 304 FS: Vacuum Design 8 EDM turbo stages (rotor) designed to optimize pumping speed for light gases 8 Turbo stators made by pressed SST sheet technology 3 TwisTorr drag stages (spiral channels) designed for high compression ratio performances Agilent’s new patentpending Floating Suspension for robust, low noise operation 21 Better HW Features: Agilent Rough Pumps New DS42i High performance Energy saving design “Inverter” not compatible with diff pump New IDP-3c High performance Oil-free scroll pump NH3 CI compatible with Agilent Quality Standards Page 22 Agilent Confidential January 8, 2013 Agilent Inert Flow Path … From Injection to Detection …now from a single supplier Ultra Inert Inlet Liner New Ultimetal Inlet Weldment, Shell and Transfer Lines Ultimetal – TCD, FPD, NPD/FID Jets Ultra Inert Gold Seal Ultimetal Capillary Flow Technology Devices, Ultimate Union Ultra Inert GC Column 23 Agilent Confidential January 8, 2013 Programmable Helium Conservation Module Works with Gas Saver function of 7890 based GC Standby Method can be programmed after the sequence ends Analytical methods are unchanged since Helium is still the carrier during the run 5977A GC/MSD IDL Specification IDL is a statistically derived value from the precision (%RSD) of 8 consecutive, splitless injections of 100fg OFN at 99 % confidence level. The more precise instruments (lower %RSD) will generate lower IDLs. The Agilent 7890B/5977A with an ALS or CTC autosampler has the following specifications: Ion Source type High Vacuum pump type IDL of OFN by 8 replicates of ALS* Extractor Source Turbo Pump 10fg Turbo Pump 24fg Diffusion Pump 30fg Inert Source These are installation specification, performed on customer site, immediately after installation and carry a lot more value than a reference specs. *Systems without an Autosampler will have only S/N specification. 25 January 15, 2013 Why IDL specification is useful for the 5977 in SIM? Influence of Noise in S/N specs • In SIM (or MS/MS) when the Noise is too low, such as during acquisition of an OFN standard, S/N results may not give the best characterization • If the noise level is insignificant - varies a lot and too low- the derived value from it (S/N) also becomes insignificant Value of IDL • IDL is derived from reproducibility/precision results, the same metrics most users utilize every day in their work. The IDL statistical process is the same used for Method Detection Limit calculations, and the %RSD values are tools to monitor analytical performance • IDL characterizes the whole system – AS, GC, MS- giving confidence in overall reliability. It is the results of 8 consecutive injections, unlike S/N in a single shut, which can be influenced by many parameters/conditions 26 January 15, 2013 The Influence of the low Noise on S/N values Same Data File, RMS, 5 Second Noise Region A 0.01 min. shift in the noise region resulted a 6000 higher S/N value. When the noise is insignificant (low), the derived S/N value is also insignificant! Noise region: 5.65min - 5.73 min S/N: 10785 S/N Noise region: 5.65min-5.73 min 27 Noise region: 5.66min - 5.74 min S/N: 3335 S/N Noise region: 5.66min-5.74 min January 15, 2013 Market Leading Performance Premium Value: The Best Just Got Better Detector Performance MSD Scan 1500:1 S/N; SIM 10 fg IDL – Best in Class with IDL tested at installation when ALS or Combi available (with Extractor Source) FID <1.4 pg C/sec ECD <4.4 fg/sec FPD <2.5 pg S/sec; <45 fg P/sec SCD <0.5 pg S/sec NPD Best for P, 0.08 pg/sec N beat only by Thermo 0.05 pg/sec– but only using OUR Blos bead! TCD 400 pg/mL No one can now offer a better specification package than Agilent 28 Agilent Confidential January 8, 2013 Market’s Best S/N (SNR) > 1500:1 Market’s Best Scan Rate = 20,000 u/s Market’s ONLY IDL < 10 fg Better from Agilent Statistical confirmation of entire system’s performance Page 29 Agilent Confidential January 8, 2013 Mass Hunter GC/MSD Software MassHunter Qual MH MassHunter Quant CS MassHunter GC/MS Acquisition MSD ChemStation DA And Use Either MassHunter Data Analysis OR MSD ChemStation Data Analysis G1701FA 30 Agilent Confidential January 8, 2013 MSD ChemStation Standard interface Quantitation Macros QEdit Reports Library Searching MSD ChemStation DA 31 Agilent Confidential January 8, 2013 MassHunter WorkStation Qualitative Analysis Chromatogram Results Data Navigator Method Explorer 32 Method Editor Spectrum Results Agilent Confidential January 8, 2013 Mass Hunter Quantitative Analysis The Quant Batch screen looks like this. Results Information for the batch can be displayed. Visual guides highlight specific data that fall outside specific, predefined conditions. Compound Information displays graphical representation of the peak, qualifier information, spectral information, and the ISTD. Visual guides help identify associated data problems. Results Information Compound Information Batch Information (i.e., Calibration Curve) Batch Information provides easy visualization and customization of relevant desired data. 33 Agilent Confidential January 8, 2013 Unknowns Analysis 34 Agilent Confidential January 8, 2013 MassHunter Excel Reporting •Excel Based (Excel 2010 supported) •MassHunter application exports data in XML and graphics files •Templates define report formatting •Over 100 shipping report templates •Reports can be altered for desired information & appearance •Customization using Excel features (function, formatting, code) •Computer Based Training for report customization by users •Some customization available through Agilent 35 Agilent Confidential January 8, 2013 Application Notes 36 Agilent Confidential January 8, 2013 Flexibility: Performance and Budget Balance of Price, GC performance, & MS performance Lowest Price 5977A Turbo MS Performance Meets 5977A Diff MS Method Requirement 7890B GC 5977E Turbo MS Inert source 5977E Diff MS 7820A Stainless source Page 37 Highest GC Performance & MS Performance 5977A EI 5977A EI/CI 7890B GC Extractor source DS42i Maintenance and Support Issues 38 Agilent Confidential January 8, 2013 Q&A Discussion 39 Agilent Confidential January 8, 2013