LEDA The Multifunctional System

advertisement
LEDA
The Fastest Hair Removal Laser
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Quantel Derma
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
•
Development, Manufacturing, Sales,
Marketing and Service of Lasers and
Light Systems for Dermatology and
Aesthetic
•
Part of the Quantel Group of France
In the Laser business since 1970
•
Most comprehensive portfolio of
products and applications
Product Overview
LBO - KTP
532
308
Excimer
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
550
LED – SCR
Alexandrite
585
755
630
IPL
635
694
Ruby
Nd:YAG
1,064
808
980
Diode
Er:YAG
2,940
1,540
Er:Glass
10,600
CO2
LEDA EPI – Fastest Hair Removal Laser
• Fastest hair removal laser
- 808 nm for all skin types
- 980 nm for darker skin types
• LED technology as an
additional option
• Platform for several energybased technologies in the
future
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
LEDA EPI
The fastest Laser Hair Removal System
• LEDA EPI is the fastest hair removal
laser system in the market
• Entire back can be treated in less than
10 min without any compromise to
fluence and pulse duration
• Special features for the treatment of
sensitive skin like the registered FHR®
Fractional Hair Removal Technology
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Current Hair Removal Technology
Repositioning requires a lot of time
Courtesy of Prof. Dr. Uwe Paasch, Leipzig University, Germany
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
New Scanning Technology for Hair Removal
Result: LEDA is fast and effective!
Courtesy of Prof. Dr. Uwe Paasch, Leipzig University, Germany
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Hair Removal – Spot versus Continuous Scanner
Much faster treatment with linear scanning
Spot
Scanner
Quantel
Derma
approach
Principle
Single shots
Different spots
Scanned along the skin
surface
Duty Cycle (% light on)
< 10 %
30 - 40 %
Light intensity
> 1,500 W/cm2
> 2,500 W/cm2
Required light output
2,900 W (best in class)
300 W
Result: LEDA is fast due to high duty cycle
LEDA is effective due to high light intensity
LEDA is transportable due to low required light output
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Hair Removal – Spot versus Continuous Scanner
As effective as established methods
Scanner
Spot
Quantel
Derma
approach
Position of applicator
Difficult to achieve optimal
overlap
Optimal positioning in large
spot due to scanner
Penetration depth
Depending on spot size
Deep homogeneous heating in
the hair root layer
Treatment time
Long because of many new
positionings
Short because of few new
positionings
Power consumption
weight, size
High, due to high required
light output
Low, due to low required light
output
short pulses possible
No
Yes
Result:
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
LEDA is effective on deep lying hairs due to penetration Depth
LEDA is effective on fine hairs due to possiblity of short pulses
Current Epilation Technology
Time period
between two shots
is much larger than
the shot itself
Laser switchedon for less than
10% of the
treatment time
sufficient fluence
and
penetration depth
High powered
lasers
(> 1 kW) to
generate it
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Slow 
Long
treatment
time
Heavy and
bulky laser
New Epilation Technology
Laser fires during
entire
scanning period
Laser switchedon for more
than 30% of the
treatment time
Fast 
Short
treatment
time
sufficient fluence
and
penetration depth
Small slit only
with pre- and
post scattering
of the light
Small and
portable laser
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
High light intensity with scanning technology
Scanning technology
Current spot by spot technology
L
A
S
E
R
High light intensity due to
focus on small slit
- 2,500 W/cm2
- 300 W required light
output
Courtesy of Prof. Dr. Uwe Paasch, Leipzig University, Germany
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
L
A
S
E
R
Low light intensity due to
spot
- 1,500 W/cm2
- 2,900 W required light
output
Light on time of more than 30%
with scanning technology
Scanning technology
Light on for the entire scan
On-time: complete scan
Off-time: 1 sec repositioning
-> more than 30% on-time and
shorter treatment time
Courtesy of Prof. Dr. Uwe Paasch, Leipzig University, Germany
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Current spot by spot technology
Light off-time > light on-time
On-time: 0,1 sec x 5 = 0,5 sec
Off-time: 0,9 sec x 5 = 5 sec
-> 10% on-time
Best Wavelengths for Hair Removal
Lighter skin: 755 nm to 808 nm due to medium absorption in melanin
755 nm Alexandrite laser
1,064 nm Nd:YAG laser
808 nm Diode laser 980 nm Diode laser
LEDA EPI 808 is optimal for hair removal of lighter skin (like many other
systems for years).
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Best Wavelength for Hair Removal
Darker skin: 980 nm due to low absorption in melanin
755 nm Alexandrite laser
808 nm Diode laser
1,064 nm Nd:YAG laser
980 nm Diode laser
LEDA EPI 980 is optimal for hair removal of darker skin.
1,064: too low absorption in melanin (painful, too high penetration depth)
808:
high absorption for darker skin (risk of side effects)
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
LEDA Hair Removal - Clinical Effect
It works!
5 weeks after first treatment
With insufficient overlap
Pictures: Courtesy of Prof. Paasch, Leipzig, Germany
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
LEDA Hair Removal – Treatment Examples
LEDA EPI 980 for dark skin
Before
Before 3rd session
LEDA EPI 980
treatment parameters:
Energy: 24 J/cm2
Pulse duration: 30 ms
Photographs: Courtesy from Dr. Chandrashekar, Bengaluru, India
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
LEDA Hair Removal – Treatment Examples
Black hair is gone, only white/grey hair stays
Before
Before 5th session
LEDA EPI 980
treatment parameters:
Energy: 24 J/cm2
Pulse duration: 30 ms
Photographs: Courtesy from Dr. Chandrashekar, Bengaluru, India
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Proven Clinical Results
Presented at
ASLMS 2009*
Study with 31 patients
and 6 month follow-up
after last treatment
As effective as
Alexandrite Laser
Presented at
EADV 2009**
Study with 18 Patients
and 6 month follow-up
after last treatment
As effective as
established Diode Laser
* Bodendorf et. Al: Hair removal with a continuous laser
** Slouka and Voltr: Efficacy and safety of a linear scanning
808 nm diode laser for hair removal
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
LEDA EPI 808 nm – Clinical Trial in Leipzig
Full scale clinical trial to compare LEDA to Alexandrite
• Epilation of axillary hair of 31 patients
 Right axilla:
Alexandrite (ARION)
25 J/cm² 30 ms*
 Left axilla:
LEDA Epi 808 nm
24 J/cm² 12 ms*
• 6 treatment sessions
 Final results with 6 months follow-up presented at 29th ASLMS,
National Harbor 2009 (now 18 months follow-up)
* Parameter of first treatment session
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Hair removal with a continuous wave laser
Marc Oliver Bodendorf, Sonja Grunewald, Monica Illes,
Jan-Christoph Simon, Uwe Paasch
Division of Lasers and Aesthetics, Department of Dermatology
University of Leipzig, Germany
29th ASLMS Annual Conference, National Harbor, Maryland
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Material and
methods
Subjects enrolled into the study n = 31 (♂
= 3; ♀ = 28)
Skin type I-IV
brown-dark axillary hair
Exclusion criteria
 Pigmentary disorder
 Pregnancy and Lactation
 Infection
 Pre-treatment axillary laser
hair removal
Hair counting Trichoscan™
right axilla
Alexandrite 755 nm
spot scan
Trichoscan ™
6
x
6
x
Treatment 1- 6
Trichoscan ™
Treatment 1- 6
25-30 J/cm² 30-40 ms
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
left axilla
Diode 808 nm
continuous
scan
24-30 J/cm² 12 ms
Follow-up after 6 months
Hair reduction: Trichoscan (haircount per 0.651 cm²)
LEDA is as
effective as the
gold standard
= Alexandrite
also for FINE
hairs
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Clinical pictures
Before treatment
Photographs courtesy of Prof. Paasch, Leipzig, Germany
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
4 weeks after 4th Tx
LEDA EPI 808 nm – Clinical Trial in Leipzig
Pain assessment
• Directly after treatment
 How painful was the treatment?
(0 = not at all, 10 = like a nettle-contact)
Similar pain as
Alexandrite
4,4
• One hour post treatment
 How painful is the treated area now?
(0 = not at all, 10 = like a nettle-contact)
0,2
 How itchy is the treated area now?
(0 = not at all, 10 = like 5 insect bites)
0,2
 How is the redness of the treated ares now?
(0 = not at all, 10 = like a strong sunburn)
0,2
 Are you restricted in your physical activities?
(0 = not at all, 10 = need rest in bed)
0,0
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
LEDA EPI 808 nm – Clinical Trial in Plzen
Second trial to compare LEDA with standard diode laser (LightSheer)
• Epilation of axillary hair of 18 patients
 Right axilla: Diode Laser LightSheer 810 nm
 Left axilla: Diode Laser LEDA EPI 808 nm
• 6 Treatment Sessions
 Treatments included pain assessment
 Presented with 6 months follow at EADV, Berlin 2009
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Efficacy and safety of a linear
scanning 808 nm diode laser system
for hair removal
•David Slouka |
•Jiri Voltr |
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Charles University, Medical School Plzen, Czech Republic
VS LASERA Laser Centre Plzen, Czech Republic
Results
LEDA
LightSheer
100%
LEDA is as
effective as
LightSheer but
much faster
100%
-50%
-54%
-69%
-63%
-65%
-75%
TS = Treatment session
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
LEDA EPI 808 nm – Clinical Trial in Plzen
Clinical pictures
Axilla treatment LEDA Epi 808 nm
Before
Photos: Courtesy of Dr. David Slouka, Plzen Czech Republic
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
After 2nd treatment with LEDA
LEDA EPI 808 nm – Clinical Trial in Plzen
Clinical pictures
Axilla treatment LEDA Epi 808 nm
Before
Photos: Courtesy of Dr. David Slouka, Plzen Czech Republic
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
After 2nd treatment with LEDA
Biology:
What causes the pain?
Skin is very sensitive to outside influences due to a high number of
different cutaneous receptors, such as:
• Thermoreceptors
(for heat)
• Mechanoreceptors
(for mechanical stress)
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Pain Reduction at Hair Removal
Pain level is dependent from
Pain reduction can be achieved by
• Level of external nerve
stimuli
• Decreasing the external
nerve stimuli (= less heat!)
• Number of stimulated
nerves at the same time
• Decreasing the influenced area
(= smaller spot size!)
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Principles of Low Fluence Hair Removal
(= less heat) with LEDA EPI
Options for low fluence
treatments
Advantages (+) and
Disadvantages (-)
•
Treatment of skin with
fluence of less than 12 J/cm2
(e.g. Lumenis LightSheer
Duet)
+
+
-
•
Energy is not delivered in
one shot or path but in
several paths
(e.g. IN-Motion™
technology from Alma)
+ Applicable for tanned skin
- Uncontrolled procedure
- Time consuming
Lower pain level
No Cooling required
Bad results on fine hairs
No long-term efficacy proven
Low fluence is a good option for tanned and sensitive skin to remove
thick hairs
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Low Fluence Hair Removal with LEDA EPI
• Low fluence (6 – 12 J/cm2) can be applied with short pulse durations
• Efficacy: multiple spots with low fluence for gentle heating up of the
hair bulb, surrounding tissue can cool down between spots
• Full control of energy and stacking
2
1
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
The Effect of Spot size
LEDA EPI distance holders
Experience by many patients
with sensitive skin
Small spot size is less painful than
large spot size using the same
parameters (fluence and pulse
durations)
Small spot 10 x 12 mm
e.g. for upper lip
Large spot 50 x 12 mm
e.g. for legs and backs
How can the lower pain of the small spot be combined with the high
speed of the large spot?
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
FHR® Fractional Hair Removal Mode
for Sensitive Skin
• Quantel Derma has developed the registered FHR® Fractional Hair
Removal technology
• The large spot size (10 x 50 mm2) is divided into 2 – 4 smaller
treatment areas
FHR® Fractional Hair Removal Mode
Standard mode
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
1
1
3
2
4
1
1
3
2
4
LEDA System: Offering many Options
The LEDA EPI is the only system,
that combines
•Standard Treatment
(either guided or direct input)
•Low Fluence Hair Removal
•FHR® Fractional Hair Removal
User can select the number of
simultaneous treatment areas:
2 “Normal Comfort”
3 “Medium Comfort” or
4 “High Comfort”
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Which mode should I use?
• Standard Hair Removal Mode
+ Fastest mode (10 min for a back)
+ Useful for light skin types
- Can be painful for sensitive or darker skin
• FHR® Fractional Hair Removal Mode
+ As effective as standard mode, but reduced pain
+ Useful for light skin types
- Prolonged treatment time (15 min for a back)
• Low Fluence Hair Removal Mode
+
+
+
-
very low pain
safe treatments
Best for darker skin types especially with 980 nm
Prolonged treatment time (~ 20 min for a back)
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Example of an individualized Treatment Regime
Start of 1.
session
1. – 3.
session
4. – 6.
session
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Quick Treatment Guide
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Parameters of Factory Settings*
High Fluence vs. Low fluence
High Fluence
Low Fluence
2 sub pulses each
6 – 12 J/cm2
*(not US-Version)
** (not included in treatment wizzard)
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
White Paper Low Fluence Hair Removal Mode
by Dr. Adatto, Switzerland
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
LEDA EPI – Software Menu
Treatment wizzard – Skin type
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
LEDA EPI – Software Menu
Treatment wizzard – Hair color
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
LEDA EPI – Software Menu
Treatment wizzard – Hair thickness
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
LEDA EPI – Software Menu
Treatment wizzard – Settings confirmation
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
LEDA EPI – Software Menu
Press OK if everything is correct
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Advantages Contact cooling
1. Homogeneous Cooling
2. Compact design (portable chiller)
3. No noisy air cooler
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Exchangeable Sapphire Glasses
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Two attractive options of an integrated system
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
LEDA EPI – Technical Specifications
EPI 808
EPI 980
Laser type
Diode
Diode
Wavelength
808 nm
980 nm
Spot size
50 x 12 mm / 10 x 12 mm
50 x 12 mm / 10 x 12 mm
Pulse width
6 - 40 ms
6 - 40 ms
Max. Power density
60 J/cm²
60 J/cm²
Skin cooling (opt.)
cold air or contact
cold air or contact
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
LEDA EPI – Summary
LEDA EPI – Revolution in hair removal:
• Effective due to proven wavelengths and large spot size, 50 x 12
mm
• Fast hair removal of complete back in less than 10 min.
• Flexible due to transport allowance, Plug and Play, table top system
• Versatile proven wavelength 808 nm and especially designed
handpiece 980 nm for darker skin types
© Copyright Quantel Derma GmbH 2011
2011-03-14_Master and Sales Presentation LEDA_Rev10
Download