TDLS Applications

advertisement

INTRODUCTION

OPSIS is a Swedish company which develops, manufactures and supplies total solutions for Ambient Air Quality Monitoring, Stack

Emission Monitoring and software tools for Air Quality Management.

Founded 1985

OPSIS is represented world-wide, with internationally accepted and approved products.

OPSIS PRODUCTS

MAJOR APPLICATION AREAS

QUALITY AND ENVIRONMENTAL

MANAGEMENT

ISO 9001

• Quality

ISO 14001

• Environment

ISO 17025

• Calibration laboratory

• Ackreditation laboratory

OPSIS CEM SOLUTIONS

CEM/PROCESS SOLUTIONS

UV/IR DOAS IN-SITU SYSTEMS

TUNEABLE DIODE LASER IN-SITU SYSTEMS

DILUTION EXTRACTIVE SYSTEMS

LASER DIODE ANALYSER

Features :

• Fast response time (~ 1 sec)

• Multiple paths

• Multiple gases

• Analyser separated from Emitter/Receiver

• Long fibre lengths (< 1 km)

• Low detection limits

SYSTEM OVERVIEW, CEM

LD500

EM060L

Cabinet

Laser fibre optical cable (< 1 km)

Communication cable (< 2 km)

RE060L

Emitter Receiver with detector and A/D converter

SYSTEM DESIGN

Stack Digital signal

LD500 analyser

Ramp generator Diode laser

Internal Detector

Reference cell

Beam switch

”Zero” signal / ”Reference” signal

Wavelength/scanning control signal

Beam splitter CC

Communicatin Interface

”Measurement” signal

PC Processor

LD500

TUNING THE LASER

ΔT Δλ

NIR semiconductor laser

Controlled variations in temperature will ”tune” the diode lasers output wavelength.

The temperature variations are created by applying a sinus shaped drive current with a frequency of 1 kHz, with a temperature accuracy of 0.001 C˚

Absorbance

100%

O

2

HF

ABSORPTION SPECTRUM

Laser is tuned around one or a few absorbtion lines,

Scanned range is typically less than 1 nm

H2O

0 %

1.25 um

1.35 um

LD500

SPECTRA HANDLING

”Zero” signal

”Measurement” signal

Resulting spectrum

The scanned spectra are resolved into 1000 channels

Measurement spectrum is divided with the Zero spectrum to obtain the resulting spectrum and to eliminate noise generated by the laser

I

1

I

2

C =

Ln ( I

1

α

1

/ I

2

– α

2

) x l

+ Line Widening effects due to temperature & partial pressure

EVALUATION

The cross section area of the obtained spectrum is used to calculate the concentration by use of Beer

Lamberts law, compensated for line widening effects

RESULTS

Results are presented as :

Concentration ( typically % (vol) , ppm or mg/m3 )

Standard deviation ( typically ppm or mg/m3) , based on the average standard deviation over the evaluated number of channels in the measured cross section spectrum

Light level, expressed as dB , proportional to the amplification required on the detector.

MEASURING TEMPERATURE

Absorption lines

Temperature can be measured by studying the proportions and relations of the absorption lines, as they change with temperature

HARDWARE

•Central Unit

•Incl.

-Laser Head

-Keyboard

-Modem

-IO 256

-RS 232

-Protocol for PLC

EMITTER

RECEIVER

PERFORMANCE

Gas Typical

Range

Detection limit

( 10 metre)

CO2

CO2

O2

H2O

CO

CO

0-100% 0.01%

0-10000 ppm 0.5 ppm

0-21%

0-100%

0.01%

0.01%

0-100% 0.01%

0-10000 ppm 10 ppm

CH4

CH4

NH3

HCL

0-100%

0-10 000 ppm

0-1000 ppm

0-1000 ppm

HF 0-50 ppm

Temperature 0-1500 ° C

0.01%

0.2 ppm

0.05 ppm

0.05 ppm

0.005 ppm

+/- 5 ° C

CEM/PROCESS EXAMPLE

(maximum 8 paths )

Emitter

Optical fibre cable

Laser Module

Laser Module

Laser Module

LH51n

24 VAC

Multi

Communication fibre cable

SIGNAL LAYOUT

Receiver

A/D

+/-15 VDC

+6 VDC

110/220-240 VAC

RS232

Computer

PC104

Hard Disk

Floppy Disk

LCD

Keyboard

Modem

+/- 15VDC

PM020 CM002

110/220-240 VAC

IM001 OM001

DM016

0-10VDC

0/4-20 mA

0/4-20mA Status

I/O

Ioman Signal Handling System ( Optional)

+/- 12VDC

+5 VDC

LD500 Analyser

110/220-240 VAC

LH 514 Laser Module

Typical Applications:

• Process monitoring

• Tunnel monitoring

• Steel plants

• Cement plants

CO , CO2 , H2S

O2 AND TEMPERATURE

LH 515 Laser Module

Typical Applications:

• Furnace control

• Steel process

• Smelters

• Incinerators

LH 512 Laser Module

Applications:

• Waste Incinerators

• Chemical industry

• Acid Scrubbers

HCL

LH 513 Laser Module

Applications:

• DeNO x

Applications

• Fence-line monitoring

• Fertilizer industry

NH3

IPP-TAIWAN: 20 g/m3 dust , 300 degrees C, 4 metre path

ER60L-Receivers Power supply for detector

ER60L-Emitters

LH 516 Laser Module

Applications:

• Petrochemical plants

• Coke ovens

• Landfill

CH4

LH 511 Laser Module

Applications:

• Aluminium smelters

• Fence line monitoring

• Chemical industry

HF

POTROOM MONITORING

EXAMPLE , HF DATA

Pot activities

CALIBRATION

Calibration cell

Standard gas

Emitter Calibration bench

Receiver

Analyser

LD500

CALIBRATION EQUIPMENT

Rotameter

(flow control)

Calibration gas

LD500

Receiver

Emitter

Calibration bench Gas valves

COMMUNICATION ALTERNATIVES

Plant DSC/PLC

RS232, Alternative 4 ( Cactus, ABDH, ModBus, Siemens 3964R, Comli)

Enviman ComVisioner

Analyser

RS232, Alternative 3 LAN

RS232, Alternative 1

RS232

RS232, Alternative 2 +3

+/- 15VDC CM

IM001 OM001 DM016

110/220-240 VAC

0-10VDC

0/4-20 mA

0/4-20mA Status

I/O

Ioman Signal Handling System ( Optional)

STEEL PLANT APPLICATIONS

EMISSION MONITORING

Vizag steel plant Visakhapatnam,

India,using Opsis analysers for monitoring NOx and SO2 in 15 stacks

REHEATING FURNACE

Purpose

Used by all steel processing plants to heat material before treatment

Often crucial to meet right temperature

Can replace soaking pit

Operation

Oil- or gas burners heat the oven compartment

Desire to use natural- or waste gas

Comparably low dust level

REHEATING FURNACE

Measurements of interest

Oxygen : decrease level to reduce fuel consumption and oxidation but keep sufficient levels for effective combustion

Carbon Monoxide: as indicator of incomplete combustion

Temperature: Important for correct process

Problems to overcome

Tendency of smoke formation at low oxygen levels

Hot environment

MONITORING AFTER REHEATING FURNACE

TAIL GAS DUCT

SLABS

REHEATING FURNACE

AR600 ( NO,NO2,NH3)

LD500 ( O2)

CORUS STEEL installation in European Plant

Installed early 2007

Measuring NO,NO2,NH3,O2

Temperature is approx. 450 degrees C

CORUS STEEL MEASUREMENT DATA

CORUS STEEL MEASUREMENT DATA

POSCO STEEL, SLAB REHEATING

FURNACE

= measurement location for Oxygen d

SLAB

1100 ° C 1200 - 1300 ° C 1100 ° C

Charging zone Preheating zone Heating zone Soaking zone d

: Open-path height from SLAB surface 30 – 40mm

Cross section = 13 metre

MODIFICATIONS MADE FOR REHEATING

FURNACE APPLICATION

Wall

Laser beam

Max 85 degrees C

Max temperature , 40 degrees C

RC101L+ PS

RE060L-T

Furnace duct

1300 degrees C

LD500

CF120, max 1000 metre

Room temperature ( 15-30 degrees C)

Max 50 metre cable

50mm diam hole

Instrument air

New modifications:

1.Moved out electronic cards from RE060L, to a separate enclosure that can be installed at a distance up to 50 metre

2. Improved laser with 3 mW output compared to old laser with 0.1 mW, allows better light levels and handling of high dust levels

3.Opsis R&D department has installed a high temp heated measurement chamber which allows test environments up to 1300 degrees C .This has resulted in improved spectra handling and evaluations

MONITORING CO AND HYDROCARBONS

Unknown compounds, most probably hydrocarbons.

Can be presented as unknown compound X,Y,Z etc , if of any interest for the user.

CO spectrum ( blue) recorded in reheating furnace, compared with factory spectrum( red/blue)

Absorption is too a large extension covered by unknown absorption lines, most probably hydrocarbons , making it difficult to reach very low detection limits for CO ( which also have weak absorption due to temperature induced line widening effects)

R&D is ongoing to overcome the problems and to reach better performance for CO

OTHER POSSIBLE APPLICATIONS

Blast furnace off gases ( CO,CO2)

LD converter off gases (CO,CO2,O2)

Coke oven off gas/leaks ( CH4,CO,O2,BTX)

Sinter plant off gas/waste gas ( H2O,HF,HCL)

Technical comparison

Paths

Up to 8 paths OPSIS

LD500

Principle

Separate TDL

Optical cable

Multiple TDL (4)

Switching TDL

TDL in the emitter Only 1 path NEO

SIEMENS Separate TDL

Optical cable

Up to 3 paths

Signal handling Comments (+/-)

I/O up to

255channels

RS232 with several ind.protocols

Modem

+Multiple path (max 8)

+Multiple gas ( max 4)

+Also includes logger (IO256)

+Built-in cal.check

I/O

RS232

I/O

RS232

+/-Simple system

- Limit in distance

-TDL on the duct

-Only one path

+Multiple paths

+Built-in cal.check

BOREAL Separate TDL

Optical cable

Up to 8 paths I/O

RS232

+Multiple paths

CONCLUSIONS

Opsis LD500 TDL system features:

• Fast response time (~ 1-10 seconds)

• Semiconductor laser = reliable, long life time

• Multiplexing of up to 8 paths ( = cost effective solutions)

• Multiple gases ( HF,CO, CO2, H2O ,HCL,NH3, CH4…..)

• Up to 4 different gas compounds in the same analyser

• Long fibre cable lengths (< 1 km)

• Low detection limits

• Can operate in high dust environment

• Can operate in high temperature environment

• A minimum of maintenance

Download