Designing to Prevent Disasters: Mechanical System Failures and Physical Plant Design Bill Zavatkay PE, LEED AP BD+C – HDR Mechanical Engineering Section Manager Introduction Disasters A Regulatory Requirements Physical Plant By definition, a disaster is, "an occurrence causing widespread destruction and distress, a grave misfortune, a total failure..." A disaster is often further defined as being either a man-made or natural event that results in death, injury, and property damage which cannot be managed through normal, routine channels. (Source: Google…Author not indicated). 2014 ACLAM FORUM: Coeur d’Alene, Idaho Introduction Disasters B Regulatory Requirements Physical Plant What we typically think of as a Disaster? 2014 ACLAM FORUM: Coeur d’Alene, Idaho Widespread flooding from levee breaches and storm surge 2014 ACLAM FORUM: Coeur d’Alene, Idaho Widespread flooding from levee breaches and storm surge 2014 ACLAM FORUM: Coeur d’Alene, Idaho Wind and flood damage 2014 ACLAM FORUM: Coeur d’Alene, Idaho Wind damage to buildings 2014 ACLAM FORUM: Coeur d’Alene, Idaho Tree damage to buildings 2014 ACLAM FORUM: Coeur d’Alene, Idaho Impassable roads 2014 ACLAM FORUM: Coeur d’Alene, Idaho Natural disasters occur and make big headlines, but more likely events include: • Facility Failures • Operational Issues • Power Outages 2014 ACLAM FORUM: Coeur d’Alene, Idaho Fires Failed Equipment Broken Pipes 2014 ACLAM FORUM: Coeur d’Alene, Idaho Introduction Disasters C Regulatory Requirements Physical Plant R E G U L ATO RY R E Q U I R E M E N T S Green / Sustainable / LEED / Energy Star / ASHRAE 90.1 = “SAVE THE PLANET” Building codes / GUIDE / BMBL / WHO / NIH DRM / AALAC / USDA = “Safety” • • • • Safety for building occupants as well as “the public” Minimum exhaust stack velocities (vs energy savings) Redundant equipment (increased electrical load) Spare capacity (effects on operation energy use) Combined equals your Project 2014 ACLAM FORUM: Coeur d’Alene, Idaho T H E G U I D E – B A S I C H VA C R E Q U I R E M E N T S » Performance Based Approach • Temperature and humidity control to minimize variations. • Pressurization Control – Directional Airflow • HVAC system to be designed for reliability, ease of maintenance and energy conservation. • Temperature: 68-79 deg F, maintain +\- 2 degrees F (varies based on species) • Maintain Humidity 30-70% year round. • Redundancy • Temperature control for each holding space. • Emergency power for critical services (HVAC, freezers, ventilated racks, isolators) 2014 ACLAM FORUM: Coeur d’Alene, Idaho N I H D R M - B A S I C H VA C R E Q U I R E M E N T S » Prescriptive Based Approach • Animal Facilities shall meet the requirements of “The Guide” • Laboratory Spaces shall meet the requirements of the BMBL. • Design conditions: ASHRAE 0.4% summer, 99.6% winter • Equipment sized for 20% future expansion. • 15 ACH Small Animal Static Rack/Large Animal • 10 ACH Small Animal Ventilated Rack • Exhaust fans on emergency power. • Dedicated Air Systems » Non-Research Function » Animal Areas » Lab General Research. • N+1 Redundancy Required. • Emergency Power Required; AHU’s, EF, chillers, boilers, pumps, etc. 2014 ACLAM FORUM: Coeur d’Alene, Idaho T H E G U I D E – PA G E 3 5 Animal facilities may be subject to unexpected conditions that result in the catastrophic failure of critical systems or significant personnel absenteeism, or other unexpected events that severely compromise ongoing animal care and well-being (ILAR 2010). Facilities have a disaster plan. must therefore The plan should define the actions necessary to prevent animal pain, distress, and deaths due to loss of systems such as those that control ventilation, cooling, heating, or provision of potable water. If possible the plan should describe how the facility will preserve animals that are necessary for critical research activities or the irreplaceable. Knowledge of the geographic locale may provide guidance as to the probability of a particular type of disaster. 2014 ACLAM FORUM: Coeur d’Alene, Idaho NIH GUIDELINES » “Spare” • • • • • Capacity Issues Different than redundancy or reliability Owner driven (program revisions) NIH DRM requirements for 20% spare capacity Process loads (large % of total load) Major equipment turndown Issues » Chillers » Boilers n+1 + 20% » AHU Components • • • • • Coils Filters Fans Humidifiers Airflow Stations » Exhaust fans = Potential Loss of Efficiency Until Used 2014 ACLAM FORUM: Coeur d’Alene, Idaho Introduction Disaster Preparedness D Regulatory Requirements Physical Plant “ S I N G L E P O I N T O F FA I L U R E ” • Every system will fail at the least opportunistic time. • Design, plan, educate and train to eliminate or provide redundancy for every critical system. 2014 ACLAM FORUM: Coeur d’Alene, Idaho “ S I N G L E P O I N T O F FA I L U R E ” Identify all Critical systems: MEP Systems: • • • • • • • Air Handling Units Exhaust Fans Cooling Heating Controls Potable Water Power 2014 ACLAM FORUM: Coeur d’Alene, Idaho “ S I N G L E P O I N T O F FA I L U R E ” MEP Critical systems: • • • Need Redundancy Need Spare Parts Need Maintenance Staff to Install Spare Parts 2014 ACLAM FORUM: Coeur d’Alene, Idaho PHYSICAL PLANT Reliability is a measure of probability that the environmental systems will be operational at the time that it is required. Redundancy is a subset of reliability and can be achieved by the engineering systems, or a combination of engineering systems and protocols 2 at 50% 3 at 33% 4 at 25% 2014 ACLAM FORUM: Coeur d’Alene, Idaho PHYSICAL PLANT No redundancy Scenario One AHU and one EF serves each zone Lab Zone Lab Zone 2014 ACLAM FORUM: Coeur d’Alene, Idaho PHYSICAL PLANT Partial Redundancy Scenario Requires ductwork and control dampers to allow interconnection of air systems Requires extensive ceiling space Reduces quantity of equipment to provide redundancy Lab Zone Lab Zone 2014 ACLAM FORUM: Coeur d’Alene, Idaho PHYSICAL PLANT Fully Redundant Scenario – 2N or 2@50% Greater equipment requirements Automatic Operation Less dependency upon other systems Lab Zone Lab Zone 2014 ACLAM FORUM: Coeur d’Alene, Idaho PHYSICAL PLANT Reliability & Redundancy • independent systems • N+1 (100%) back-up capability desirable • Less than N+1 with load shedding • consider utilizing systems adjacent to vivarium spaces as an alternate means to provide redundancy 2014 ACLAM FORUM: Coeur d’Alene, Idaho PHYSICAL PLANT AHU fan redundancy options Fan Wall Dual Fans 2014 ACLAM FORUM: Coeur d’Alene, Idaho PHYSICAL PLANT Failure Protection - Automation • normal operation • exhaust failure – supply reacts • supply failure – exhaust reacts • BAS controls & interlocks • maintain directional airflow (positive or negative pressurization) • consider ‘load shedding’ strategies 2014 ACLAM FORUM: Coeur d’Alene, Idaho PHYSICAL PLANT Central Utilities (Campus ScenarioIssues) • Large Chiller Plants typically not on emergency power backup • Large Boiler Plants typically not on emergency power backup 2014 ACLAM FORUM: Coeur d’Alene, Idaho PHYSICAL PLANT Central Utilities (Campus ScenarioResolutions) • Consider providing small backup air cooled chiller and pumps for critical cooling. • Consider providing small backup boiler and pumps for critical heating 2014 ACLAM FORUM: Coeur d’Alene, Idaho PHYSICAL PLANT Potable Water • Consider providing potable water backup storage tank if water outage typical. • Provide maintenance staff on hand to repair pipe leaks. • Ensure shut-off valves are in place in case of emergency. • Periodically exercise valves to ensure they will be operational when required. 2014 ACLAM FORUM: Coeur d’Alene, Idaho PHYSICAL PLANT - POWER Normal Power • Redundant Feeders to a double ended substation •Redundancy and independent electric services •Should come from two separate utility generating stations (Or from two separate substations on a campus configuration) •Feeders should be in separate duct banks and routing. • Provides redundancy in feeders and in services to building. 2014 ACLAM FORUM: Coeur d’Alene, Idaho PHYSICAL PLANT - POWER EM Power • Generators • Serve critical equipment •Supply air handlers •Exhaust fans •Caging systems (IVCs) •Heating & Cooling systems •Distribution pumps •BAS system controllers UPS • BAS control panels to keep from resetting controls to minimize downtime under any failure scenario 2014 ACLAM FORUM: Coeur d’Alene, Idaho PHYSICAL PLANT… Locate vivarium above flood elevation levels – New facilities » Flood gates or retaining walls around existing facilities Locate physical plant above flood elevation levels Locate electrical switchgear above floor elevation levels 2014 ACLAM FORUM: Coeur d’Alene, Idaho PHYSICAL PLANT… Provide adequate level of redundancy Provide automated control Provide Emergency Power Backup Locate generators above flood elevation level Provide “enough” fuel capacity for sustained duration for outage based on risk assessment 2014 ACLAM FORUM: Coeur d’Alene, Idaho PHYSICAL PLANT… Fail closed reheat coil valves Fail open AHU preheat valve Fail open AHU cooling coil valves Interlock AHU’s with EF’s Interlock supply and exhaust air valves Security systems to prevent unwanted entry Seismic reinforcement 2014 ACLAM FORUM: Coeur d’Alene, Idaho PHYSICAL PLANT… Snowfall issues and AHU shutdowns 2014 ACLAM FORUM: Coeur d’Alene, Idaho PHYSICAL PLANT… Provide snow melt device such as MISTOP Snostop Provide bypass damper across filters that opens on high filter delta P Remove AHU pre-filters before snow occurrences 2014 ACLAM FORUM: Coeur d’Alene, Idaho PHYSICAL PLANT – MAINTENANCE • Access Outside Vivarium • Locate Equipment where it is accessible • Routine Inspection • Preventative Maintenance • Minimize Impact on Science • High Tech vs. Low Tech 2014 ACLAM FORUM: Coeur d’Alene, Idaho T H E B I O D E S I G N I N S T I T U T E AT A S U 2014 ACLAM FORUM: Coeur d’Alene, Idaho 2014 ACLAM FORUM: Coeur d’Alene, Idaho PHYSICAL PLANT 2014 ACLAM FORUM: Coeur d’Alene, Idaho PHYSICAL PLANT 2014 ACLAM FORUM: Coeur d’Alene, Idaho PHYSICAL PLANT 2014 ACLAM FORUM: Coeur d’Alene, Idaho PHYSICAL PLANT 2014 ACLAM FORUM: Coeur d’Alene, Idaho PHYSICAL PLANT 2014 ACLAM FORUM: Coeur d’Alene, Idaho Questions? 2014 ACLAM FORUM: Coeur d’Alene, Idaho