Excel Life Safety Honeywell XLS 80e 2 to 8 Loop Intelligent Control Panel Excel Life Safety XLS80e 2 to 8 Loop Intelligent Control Panel Excel Life Safety XLS80e Intelligent Repeater Panel Excel XLS80e - Network Life Safety • Peer-to-peer network – ArcNet based – Re-transmission and isolation between nodes (1 km btw. nodes) – Error checking and correction at each node – Message routing – Up to 100 network nodes – Up to 158,400 devices – Up to 25,500 zones – Up to 700A PSU – Network alarm response less than 10 seconds 4 Excel Master/Slave or “Peer to Peer” Life Safety IONISATION SENSOR BREAK GLASS MCP CONTROL RELAY MODULE MCP PRESS HERE THERMAL SENSOR ISOLATOR MODULE DOOR HOLDER CONTROL MODULE ISOLATOR MODULE EXTERNALLY POWERED SOUNDER CONVENTIONAL DEVICES BREAK GLASS PRESS HERE PHOTO SENSOR CONVENTIONAL DETECTOR INTERFACE MODULE BEAM DETECTOR DUCT HOUSING AND SENSOR THERMAL SENSOR LOOP-POWERED BASE SOUNDER CONVENTIONAL ZONE LOOP-POWERED SOUNDER 5 Excel Life Safety System Goals Life Safety • Greater fire detection accuracy with elimination of nuisance alarms • Faster response • Greater flexibility in alarm system design and application • Lower installed cost • Lower operating and maintenance cost 6 Excel Global Market Offering Life Safety • Compliant with EN54 • • • • • Large graphic LCD Multi-lingual capability Modular design Site configurable Application software flexibility 7 Excel XLS80e Applications (1) Life Safety An advanced life safety system designed for large single site and multi-site applications • • • • • Office towers Airports Hospitals Universities Manufacturing complexes • Military bases • Government buildings 8 Excel XLS80e Applications (2) Life Safety • Retrofit and new construction • Medium to large multiple building systems • Standalone systems • Networked systems 9 Excel ID3000 Technical Advances Life Safety • • • • • • • • Modular design Surface mount technology Fully automated test equipment User friendly interface Peripheral options Advanced software features Easy programming Multiple language options 10 Excel Traditional Fire Alarm Functions Life Safety • Smoke and fire detection • Sprinkler system supervision • Automatic and manual system operation Added Value Options • Advanced detection products – Filtrex™, Multi-criteria, loop powered sounders and beam detectors • Enhanced loop interface board (E-LIB) • Active and passive repeaters • Graphic annunciator driver 11 Excel Key Terms Life Safety • • • • • • • • • • Basic Equipment Kit Extension Chassis Kit LIB - Loop Interface Board E-LIB - Enhanced Loop I/F Board DTP - Dual Transmission Path Booster I/F Kit PSU - Power Supply Unit Node - A system panel in a network LCD - Liquid Crystal Display CBE - Control by Event Matrix Mimic (Graphic Annuciator) Driver Kit 12 Excel Life Safety Hardware Overview Excel Modular Design Life Safety Basic Configuration Installation/Commissioning Kit Basic Equipment Kit Cover(s) Extension Chassis (if required) Optional Expansion Modules (if required) Backbox(es) Power Supply 14 Excel ID3000 Key Components Life Safety Backbox Power Supply & Batteries Basic Equipment Kit & Extension Chassis Covers 15 Excel Modular Design Life Safety • Modular design offers: – flexibility – ease of expansion – lower service cost 16 Excel Basic Equipment Kit Life Safety Expansion Cards Processor PCB Main Chassis Base Card Display PCB 17 Excel Basic Equipment Kit Life Safety • Can be extended with: – Up to 3 Standard Loop Cards (LIB) – Up to 3 Enhanced Loop Cards (E-LIB) – One RS-232 Card – One RS-485 Card – One ID-Net Card (*) – Panel Printer 18 Excel Basic Equipment Kit Life Safety 19 Excel BEK - Inputs & Outputs Life Safety • Outputs: – A/B/C/D - Sounder or Relay programmable • Sounder - rated @ 1A/30V each • Dry contact relay - rated @ 1A/30V • Two can be programmed for German UE interface – Fault and Fire Relays • rated @ 1A/30V each – Auxiliary 26-28Vdc outputs 1 and 2 • both rated @ 1A – Battery charger max. 8.6A (130Ah batteries) 20 Excel BEK - Inputs & Outputs Life Safety • Inputs: – Mains - 230Vac ± 15% 50/60 Hz – Two addressable loops - 500mA – Tamper switch input (VF dry contact) • Serial Ports: – RS232 Port 1 • PC Programming, internal printer option – RS232 Port 2 (optional module) – RS485 Port (optional module) 21 Excel Modular Design Life Safety Extension Chassis Options Extension Chassis with 64 Zone Display Module Kit (with or without Printer) Double Extension Chassis with 255 Zone Display Module Kit Extension Chassis with PRN2000 Printer Module Kit Extension Cover Blanking Plate 22 Excel Extension Options Life Safety Extended Backbox 64/128 Zone LED’s and Panel Printer 255 Zone LED’s External Printer Support 23 Excel Modular Design Life Safety Optional Expansion Modules Printer Module Kit ID-Net Network Card Isolated RS232 Module Kit Isolated RS485 Module Kit Dual Loop Module Kit Enhanced Dual Loop Module Kit 24 Excel Standard LIB v’s. E-LIB Life Safety • E-LIB • LIB – Handles communication only – System CPU scans loops • In case of main CPU failure all detection is lost – CPU always busy – Max. 512 devices per panel – Powerful microprocessor – Degrade mode • In case of main CPU failure the E-LIB will still activate sounder circuits 1-4 and the Fire Relay when an alarm is received from the loop – CPU available for other tasks – Full device count on the panel 25 Excel Serial Communication Life Safety • RS232 Option – Isolated port – Third party interface – External printer – UniNet (NION) connection – Pager interface – VDU for terminal emulation • RS485 Option – Isolated – Master/Slave network – Multi-drop – Repeaters – Graphic annunciators 26 Excel Expansion Modules Life Safety 27 Excel Modular Design Life Safety Power Supply Selection Power Supply Unit Kit 2.5 Amp Remote Battery/Charger Enclosure Kit Universal PSU Kit 4.5A or 7.0A (External enclosure or deep boxes only) PSU DTP Booster Kit (4.5 or 7.0A PSU only) 28 Excel Power Supply Options Life Safety 2.5A PSU mounts on the side of the BEK DTP Booster mounts on the side of the BEK 4.5A PSU mounts into the deep (extended) back box 7A PSU mounts into the external charger/ battery enclosure 29 Excel Life Safety PSU with Dual Transmission Path Booster Kit • Temperature compensated battery charger • DTP required by EN54-4 for external PSU application • Maintains constant loop voltage over a wide range of mains and battery voltages • Fault monitoring on the power supply, mains and the batteries • Inhibits charger in case of an alarm 30 Excel Power Supply Options Life Safety PSU Size Typical number of loops Available auxiliary power (Total) Battery Charger 2.5A 4 1A 1.9A max. 38Ah Batteries 4.5A 6 2A 2.7A max. 42Ah Batteries 7.0A 8 2A 8.6A max. 130Ah Batteries • 7A PSU Status Indication LEDs (for use in the Remote Enclosure) 31 Excel Modular Design Life Safety Backbox Options Flush Mounting Bezels Standard Back Box Kit Backbox Extension Kit (available in ‘standard’ and ‘deep’) Extended Back Box Kit (available in ‘standard’ and ‘deep’) Double Extended Backbox Kit (available in ‘standard’ and ‘deep’) 32 Excel Back-box Options Life Safety 12Ah 17Ah 17 Ah Standard depth 38Ah 38Ah 78Ah Deep Boxes Standard Extended Double Extended External Box 33 Excel Life Safety Modular Design Cover/Door Kits Security Door Kits (available for main & extension covers) Main Cover Kit (High Security option) Extension Cover Blanking Plate Extension Cover Kit (High Security option) Double Extension Cover Kit 34 Excel Cover Options Life Safety • All covers are available in: – Black/Grey (standard) matching backbox and bezel – Red matching backbox and bezel – NEXTEL Grey - matching bezel – Stainless Steel- matching bezel 35 Excel 19” Rack Mounting Option Life Safety 36 Excel 19” Rack Mounting Option Life Safety • • • • • • • • • • 19” Rack Mounting Assembly for Basic Equipment Kit 6U x 19” Rack Mounting Assembly for 7A PSU 6U x 19” Rack Mounting Assembly for 64 Zone LED Extension Chassis & Printer Kit 6U x 19” Rack Mounting Assembly for 256 Zone LED Extension Chassis Kit 6U x 19” Rack Mounting Assembly for Printer 3U x 19” Rack Blank Cover with Mains Termination Kit 6U x 19” Rack Blank Cover with Mains Termination Kit 3U x 19” Rack Mounting Assembly for Mimic Driver Kit 6U x 19” Rack Blank Cover 3U x 19” Rack Blank Cover All available in the standard black/grey colour 37 Excel Take Your Pick! Life Safety 38 Excel Life Safety User Interface Excel Main User Interface Life Safety 6 Line x 40 Character Graphic LCD Main Control Switches System Status Indicators • Numeric Data Entry & Enter/Cancel • Navigation Keypad • Key switch Access Level 2 40 Excel Main User Interface Life Safety • Fully EN54 compliant • Simple tabbed menu navigation • Prioritised event display (Automatically displays highest priority event) • User in control/has choice of what is displayed • Simple lights and switches for common controls • Top level info displayed 41 Excel Graphic Display Life Safety • Large 240 x 64 pixel LCD 6 lines x40 characters • Short-cuts for test & disablement • Selection by direct addressing • Displays: – Time and Date – Active Point Count for each event – Event type, index and actions – Panel, Zone and Device descriptors 42 Excel Graphic Display Life Safety System Information on Windows Style Tabbed Screens 43 Excel Graphic Display Life Safety Highest Priority FIRE PRE-A EVENT TYPES AND TAB DISPLAY PRIORITIES FAULT DISAB TEST EVAC Lowest Priority AUX USER If there is insufficient room to display all 8 tabs, then the lowest (on the right) are omitted. 44 Excel Virtual Keyboard Life Safety Panel and Zone Text up to 32 Characters via Keyboard to Navigate and to Select 45 Excel Fire Alarm Display Life Safety Example - 3 Zones in Alarm: 2 Devices Alarmed in Zone 2 1 Device Alarmed in Zone 1 1 other zone in Alarm - Press “Zones in Alarm” to view others Use Navigation keys 46 to scroll through zones and display other devices, date/time of event and device % value, etc. Short-cut key selects either device or zone disablement. 46 Excel Pre-Alarm Display Life Safety PRE-ALM DISPLAY REQUIRED????? FROM P21 OF OPERATING MANUAL 3 Zones are in Pre-Alarm with 4 events in the system 2 Pre-Alarms are currently in Zone 8. Use to scroll through zones &for device selection. 47 Excel Life Safety Fault Display 3 Zones are in FAULT with 4 events in the system. Use to scroll through zones and to display device, type, value, etc. 48 Excel Life Safety Disablement Display Life Safety Excel 142 Devices Disabled in 3 input zones. 12 devices are disabled in Zone 2 (all input devices). No outputs are disabled. Use to scroll through zone list and to see device details. 49 Excel Main Control Switches Life Safety Activate 2nd Silence & Stage Delay Re-start (if in Day Mode) Sounders Silence Panel Override Delays Panel Reset & Buzzer Operate Sounders Show User Menu Toggle User Menus Toggle between Day Accept Non-Fire and Night Modes Alarm Disable Fire Relay (German VdS and Fire Output Mode) (if Configured) Show Fire Info & Scroll through Zones in Fire Accept Fire Alarm 50 Excel System Status Indicators Life Safety Fire condition exists Fault condition exists Pre-Alarm condition exists System/CPU failure Sounder O/P fault or disabled Fire relay disabled, or fire O/P disabled/in fault Fire relay or fire O/P is active 51 Excel System Status Indicators - 2 Life Safety One or more devices disabled Test mode active (Walk-Test, etc.) Mains or battery power OK Day mode active (pushbutton operated) Programmed delays enabled A Non-Fire (AUX) device activated Spare for future features Spare for future features 52 Excel Life Safety Navigation & Numeric Keys Text Edit Short-Cuts Disable/Enable Menu Select Up (Next) Left (Back) Down (Previous) Numeric Data Entry Right (Forward) Accept/Enter Cancel/Escape 53 Excel Life Safety Zone Status Indicators • FIRE and FAULT/DISABLED/TEST Indication 64 Zone LED Display Module (Single Extension Chassis) Two Variants: Zones 1 to 64 or Zones 65 to 128 255 Zone LED Display Module (Double Extension Chassis) 54 Excel Language Options Life Safety Easy translation/customisation using “Slide-In” type text labels 55 Excel Life Safety Main Features • Approved to EN54 Parts 2 and 4 • Degraded mode of operation – Enhanced LIB (parallel CPUs) • Support for: – Advanced detection devices (VIEW™, HARSH™, MULTI) – Loop powered sounders (ABS4, IBS3, ANS4, AWS3) – Loop powered beam detectors (LPB-500, LPB620) • Menu driven point/data access • Multi-level operator password control • Multiple language options – English, German, Spanish, Icelandic, Dutch/French (*) 56 Excel Life Safety • • • • • • • • Key Functions 10 sensitivity levels for Fire & Pre-alarm Adjustable alarm & fault verification delay Two-stage alarm operation Alarm silence/re-sound Sound general alarm (Evacuate) Day and Night modes Fire output(s) inhibit Internal and external printer options 57 Excel Key Functions (continued) Life Safety • • • • • • • • Powerful Control-by-Event (CBE) Auto-Learn or PC programming Duplicate address detection One-man Walk Test with counter Output device test Daily high test 2 pulse rates for outputs Time of day functions 58 System Capacity Stand-Alone Excel Life Safety • • • • • • • • Up to 8 loops 198 (99+99) devices per loop Up to 99 VIEW™ per loop Up to 1584 devices Up to 255 zones Up to 7A PSU Up to 31 repeaters Graphic annunciators (Mimic) – Up to 512 LEDs per controller • 600 event history log 59 Excel Life Safety System Capacity Stand-Alone (continued) • Four sounder circuits (NACs) – rated @ 1A each – Two programmable as VF relays rated @ 30Vdc/1A • Two 24Vdc auxiliary outputs – rated at 1A each • Two programmable inputs • SPDT Fault and Fire relays – rated @ 30Vdc/1A • Two loops as standard • One isolated RS232 port (optional) • One isolated RS485 port (optional) 60 Excel Life Safety System Capacity Networked - I • Master/Slave network – Up to 32 network nodes – Maximum 8 panels – Remainder repeaters and graphic annunciators – Up to 64 loops – Up to 12,672 devices – Up to 2040 zones – Up to 56A PSU – Max. RS485 bus length of 3000m 61 Excel Master/Slave Network Life Safety • Functionality supported across the network: – – – – – – – – Reset Silence/Re-sound Mute Evacuate Point/Zone Isolate Walk Test Zone Event Broadcast Control by Event (CBE) 62 Excel Life Safety Bldg.2 Bldg.1 Bldg.3 System Capacity Networked - II • Peer-to-peer network – ArcNet based – Re-transmission and isolation between nodes (1 km btw. nodes) – Error checking and correction at each node – Message routing – Up to 100 network nodes – Up to 158,400 devices – Up to 25,500 zones – Up to 700A PSU – Network alarm response less than 10 seconds Bldg.4 63 Excel Off-Line Configuration Tool Life Safety • Stand-alone and Master/Slave network – DOS based – Individual panel programming – Manual software authentication – Same format as ID1000 and ID2000 – Minimum training required – No special hardware requirement – Windows based Loop & Battery Calculator tool • Peer-to-peer network – Windows based – System-wide programming 64 Excel Life Safety Off-Line Configuration Tool Windows version • Windows 95/98/ME/NT4/2000 Operating Systems • Windows XP under consideration • Standard Windows editing features (cut, copy, paste, etc) • On-line error checking • Easy report printouts • On-Line Help menu 65 Excel On-Site Configuration Life Safety • Multi-level password/key-switch access – Level 2: Code 1/Keyswitch - Panel controls & menus – Level 3: Code 2 - Level 2 + Configuration menus – Level 3A: Code 3 - Level 3 + Advanced Configuration • Panel settings • Auto-learn facility • Loop/Device configuration • Text Editor (Virtual keyboard) • Control matrix editor (512 lines) • Network configuration 66 Excel User Menu Life Safety C o n f i g u r a t i o n (E n t e r L e v e l 3 P a s s c o d e) 67 Excel Easy-to-use Test Mode Life Safety FIRE BREAK GLA SS PRESS HERE 1 sec ON or follow me LED ON for 5sec Use to scroll through inputs currently under walk-test. Either Tested or Not Tested is highlighted for that device. Use to scroll through device descriptions. 68 Excel User Menu - Examples Life Safety Lamp Test checks all panel LED’s, Buzzer, L.C.D. & Contrast adjustment 69 Excel User Menu - Examples Life Safety Lamp Test also displays Panel & LIB software versions 70 Excel Configuration Menu Life Safety Level 3 Access Configuration: 1: Loop Device Configuration (auto-learn) 2: Zone Text Editor 3: Panel Text Editor 4: Control Matrix Configuration (512 lines) 5: Network Configuration 6: Panel Settings 71 Excel Configuration Menu - 2 Life Safety Loop Device Configuration 72 Excel Configuration Menu - 3 Life Safety 73 Excel Configuration Menu - 4 Life Safety Network Configuration 74