Presentazione standard di PowerPoint

advertisement
Project 2000 University
12600 - Product Training
Privileged & Confidential
1
Bed Lifting System series12579
Electronic device to vary the height of the bed
With this system, it is possible to electrically lift up and down
the bed. The system is positioned completely below the bed
with the maximum flexibility of assembly
• Range of approx 68cm.
• Maximum stability at every height with needing additional
blockage
• Integrated system with guides to stabilize the bed.
• Absorption of the whole device with a weight of di 80/100
kg. : approx 9 A
• Belts fixing on the wall trough a specif support
• Manual system in case of breakdown
• Speed: approx 15 mm/sec.
• Liftable weight: max 100 kg.
• Capacity: kg. 400 static
• Weight: about 16 kg. (the actual weight may vary
depending on the requested configuration)
Privileged & Confidential
2
Bed Lifting System series12600
Electronic device to vary the height of the bed
• Unlimited Range
• Sophisticated motor with a great power and mechanical
resistance, with integrated encoder
• Belts fixing on the wall trough a specif support
The system is positioned completely below the bed with the
maximum flexibility of assembly
• Manual system in case of breakdown
• Supplied complete with installation cable
• Absorption limited to 16 A
• Speed: about 60 mm/sec.
• Liftable weight: max 60 kg.
• Capacity: kg. 400 static
• Weight: about 8,6 kg. (the actual weight may vary depending
on the requested configuration)
Privileged & Confidential
3
Serie 12600 Diiagnostiics and ProbllemSollviing
RESET
SPIA ALLARME SPIA PROGRAMMAZIONE
Encoder Ellectroniic TopLiineBedLiifftiing controll panell
In the encoder electronic ProBedLifting are present the
following characteristics:
·Warning light (triangle)
·Warning light for entering in the programming mode
(universal key)
·Reset button (present starting form March 2011)
Serie 12600 Diiagnostiics and ProbllemSollviing
Typollogy off ffaullts:: LIIMIIT SWIITCH FAULT
the red warning light flashing with a lower frequency (flashing
frequency is two seconds on and two seconds off). The protection
system indicates such a fault in case the control unit does not
receive the standard information from the limit switch.
The cable connecting the limit switch sensor
to the
control unit is loose.
The user lowers the bed with the safety belt
fastened (the safety belt uses to disconnect
directly power distribution from the control
unit)
The user has erased the pre-set parameters by
mistake. The user has entered in the programming
mode resetting the system (or disconnected the
power distribution) or he has exited with any
programming. So the bed can no more operate.
The bed keeps in alarm condition (slow flashing)
also after resetting the system.
Disconnect the 8 pole connector on the
control unit
and check continuity between the yellow
cable and
the orange one
Disengage the safety belt; move the bed to the
initial position until the moment it stops and
then
lower it. Now the bed will operate again.
The control unit has to be programmed with
pre-set
stop positions.
Serie 12600 Diiagnostiics e ProbllemSollviing
Typology of faults: ENGINE PROTECTION FAULT
The red warning light flashes with a higher frequency (flashing frequency is half a
second on and half a second off). The protection system indicates such a fault in case
of an excessive engine effort compared to its standard working. Once the preset limit
s exceeded, the protection system starts and arrests the device working to allow the
user to remove the cause of the excessive engine effort, without damaging it.
Fault found
The user raises the bed leaving an object
on the bed which is
compressed against the roof.
The user raises the bed leaving a too weight
object on the
bed.
Release procedure
Press the reset button (if old version, without reset button,
remove the power distribution from the control panel); once
the red warning light stops flashing (please note during the
time that the red warning light flashes, the bed cannot be
used), switch on the control panel (keep pressed the arrowup
shaped button for 2 seconds) lower the bed and remove
the object left on the bed in order to reset the system and
let it operate again.
Press the reset button (if old version, without reset button,
remove the power distribution from the control panel); once
the red warning light stops flashing (please note during the
time that the red warning light flashes, the bed cannot be
used), switch on the control panel (keep pressed the arrowup
shaped button for 2 seconds) lower the
bed and remove the too weight object left on the bed, in
order to reset the system and let it operate again.
Serie 12600 Diiagnostiics and ProbllemSollviing
Typology of faults: ENGINE PROTECTION FAULT (to be continued)
Fault found
The user raises the bed when the charge
battery is under 11
volts.
Fault on the encoder or on the cable. To recognize such a
fault please follow the next procedure: reset the bed using
the specific button (if old version, without reset button,
remove the power distribution from the control panel); once
the control panel has been reactivated, raise or lower the
bed. If the bed stops again after 10 cm stroke, without
reason or without having found any pre-set stop position,
this is the case.
Release procedure
Press the reset button (if old version, without reset button,
remove the power distribution from the control panel); once
the red warning light stops flashing (please note during the
time that the red warning light flashes, the bed cannot be
used), start the vehicle’s engine, switch on the control panel
(keep pressed the arrow-up shaped button for 2 seconds)
and bring the vehicle in its end-stoke position (upper
position) to reset the system and let it operate again.
Once the procedure to identify the fault has
been repeated,
if the bed gives the same fault after only 10
cm stroke,
please bring the vehicle to a service centre
or contact us to
solve the matter.
Privileged & Confidential
7
Download