Automation and Drives AS-i Extension Plug Low Voltage Switchgear Now 200m instead of 100m !!! Technical Data Master Configuration Safety at Work AS-i SIGNUM Extension Extension PlugPlug K60 ATEX Duplication of the length per AS-Interface segment from 100 to 200 meters Considerable reduction of the costs for the network infrastructure for large networks Allows in combination with repeater a max. AS-Interface network up to 600m (if the master is located in the middle of the network) Extension of the range of applications and greater freedom in plant design by doubling the AS-Interface segment Easy monitoring by integrated under voltage detection Analogue modules Analyser Order-Nr.: Extension Plug:3RK1901-1MX00 M12 branch: 3RX9801-0AA00 Start of delivery: SIMATIC Practice Week Atlanta August 2004 05/2004 Burns 08.2004 1 Automation and Drives AS-i Extension Plug Low Voltage Switchgear Technical Data Master Configuration Safety at Work Function of the Extension Plug To build a AS-Interface segment longer than 100 m up to 200 m install the extension plug at that point in the network which is most distant to the AS-Interface power supply. It is not necessary to locate this point exactly, as it is sufficient to install the extension plug close to this point (approx. 10 m). Using the extension plug you may build AS-Interface networks in any topology (line, star,tree). You always need just one extension plug per segment even if you use star or tree structure. Depending on the length of a AS-Interface segment and the needed current (depending on the number of connected slaves) you have to consider the voltage drop along the AS-Interface cable. The extension plug is equipped with a under voltage detection for easy monitoring of the AS-Interface voltage. A green LED flashes if the AS-Interface voltage is too low. AS-i SIGNUM Extension Extension PlugPlug K60 ATEX Analogue modules Ordering data Analyser The extension plug has a M12 connection and can be easily connected via the AS-Interface M12 branch 3RX9801-0AA00 in degree of protection IP67. SIMATIC Practice Week Atlanta August 2004 Burns 08.2004 2 Automation and Drives AS-i Extension Plug Low Voltage Switchgear 200m AS-Interface network with Extension Plug Technical Data Master Configuration Safety at Work AS-i SIGNUM Extension Extension PlugPlug K60 ATEX Analogue modules Analyser Easy and cost-effective configuration of AS-Interface segments up to 200 m Larger dimension without repeater and additional power supply (= reduction of the costs for the network infrastructure) Configuration in any topology (star, tree, line) SIMATIC Practice Week Atlanta August 2004 Burns 08.2004 3 Automation and Drives AS-i Extension Plug Low Voltage Switchgear Maximum net expansion with combination of Extension Plug und Repeater Technical Data Master Configuration Safety at Work AS-i SIGNUM Extension Extension PlugPlug The maximum possible network dimension can be extended by using repeater in combination with the extension plug Please note that if using the repeater in combination with the extension plug it is not allowed to connect repeaters in series. Therefore, the maximum distance Master Slave is 400 m and the absolute maximum distance is 600 m (if the master is located in the middle of the network). It is possible to connect repeaters in parallel to realize a star topology, each branch with up to 200 m K60 ATEX Analogue modules Analyser SIMATIC Practice Week Atlanta August 2004 Burns 08.2004 4 Automation and Drives Compact Module K60 for use in explosive atmosphere (ATEX) Low Voltage Switchgear Technical Data There are two types of K60 available to use in explosive environment in zone 22 according to classification II 3D (dust atmosphere, non-conductive dust) Type 4 Inputs/4 Outputs Identification II 3D T75°C IP65X Type 4 Inputs Identification II 3D T60°C IP65X There are special conditions to consider for safe operation !!! Master Configuration Safety at Work AS-i SIGNUM Extension Plug K60 ATEX K60 ATEX Analogue modules Particularly the module has to be protected against mechanical damage by means of suitable protective measures. Further conditions see next page under „special conditions for safe operation“. Analyser Order-Nr.: 4E/4A: 4E: 3RK1400-1DQ05-0AA3 3RK1200-0CQ05-0AA3 SIMATIC Practice Week Atlanta August 2004 Burns 08.2004 5 Automation and Drives Compact Module K60 for use in explosive atmosphere (ATEX) Low Voltage Switchgear Technical Data The following safety and commissioning instructions must be observed: Manufacturer: Siemens AG A&D CD, Werner-von-Siemens-Str. 48, D-92220 Amberg, Germany Conformance with the 94/9/EG (ATEX) guidelines is proved by compliance with the EN 50281-1-1 und EN 60947-5-2 standards. Intended application: Application in explosive environment zone 22 in accordance with device group II, category 3D (dust atmosphere, non-conductive dust) Shock resistance: 1 Joule Master Configuration Safety at Work AS-i SIGNUM Extension Plug K60 ATEX K60 ATEX Analogue modules Analyser Special conditions for safe operation: The module must be protected against mechanical damage by means of suitable protective measures. All M12 connecters are to be secured against illegal opening through a safety clip in such way that disconnecting the connector is not possible manually but only destroying the safety clip. Suitable safety clips are available from Binder GmbH + Co., Elektrische Bauelemente KG, P.O. Box 1152, 74148 Neckarsulm, Germany, Phone: +49/7132/325-0, Fax +49/7132/325-150, info@binderconnector.de , item no. 16-0977-000. After addressing the module the addressing socket has to be covered with sealing cap 3RK1901-1KA01 (manipulation proof design) in such manner that the cap cannot be removed manually. Addressing of the module by means of 3RK1904-2AB01 addressing device is only permissible outside EX zone 22. K60 4E module ATEX 3RK1200-0CQ05-0AA3 with safety clip and manipulation proof sealing cap SIMATIC Practice Week Atlanta August 2004 Burns 08.2004 6 Automation and Drives New AS-Interface Analog Module (profile 7.3) Analog modules with 4 Inputs Low Voltage Switchgear Technical Data Master Configuration Order-Nr.: current measurement: voltage measurement: thermal resistance: Safety at Work AS-i SIGNUM Extension Plug K60 ATEX Analogue Modules Analogue modules Analyser new modules up to 4 analog Inputs more analog signals can be connected with one single module established K60 housing preprocessing of the analog values by the AS-i master 3RK1207-1BQ44-0AA3 3RK1207-2BQ44-0AA3 3RK1207-3BQ44-0AA3 Fast Analog Value Measurement: modules with two inputs can be changed over to just one used input the change over is done via a M12-bridge-connector using just one input the conversion and transmission time is reduced to one third Order-Nr.: conversion and transmission time current 3RK1207-1BQ40-0AA3 to the AS-I master voltage 3RK1207-2BQ40-0AA3 thermal resistance 3RK1207-3BQ40-0AA3 1 (used) input: 29 ... 95 ms 2 (used) inputs: 136 ... 235 ms M12-bridge-connector 3RK1901-1AA00 SIMATIC Practice Week Atlanta August 2004 Burns 08.2004 7 ASI Diagnostics made easy ASI Analyzer Automation and Drives Low Voltage Switchgear Technical Data Master Configuration Safety at Work AS-i SIGNUM Extension Plug K60 ATEX Analogue modules Analyser SIMATIC Practice Week Atlanta August 2004 Burns 08.2004 8 Automation and Drives Diagnostics with AS-Interface Low Voltage Switchgear Lifetime of Installation Operation / Commissioning Maintenance Technical Data Master Configuration Safety at Work Requirement AS-i SIGNUM Fast fault repair Documentation Verification of function and quality Test protocols for release Preventive diagnostics Identification of failed component Verification of quality Minimisation of service time Fault Fast fault repair Cause of fault Verification of function Documentation Extension Plug Solution K60 ATEX Analogue modules Analyser AS-Interface Analyser System Functions The AS-Interface analyser allows a complete diagnosis of AS-Interface networks during the whole lifetime of the installation. It is the ideal SIMATIC Practice Week Atlanta 2004 diagnostics. Burns 08.2004 supplement forAugust local 9 Automation and Drives Parasitic inductions on AS-interface Low Voltage Switchgear MASTER Technical Data EMC Slave Slave Master Configuration Safety at Work AS-i SIGNUM Extension Plug K60 ATEX FAULT IN COMMISSIONING Analogue modules CONTACTING Slave Analyser Defective Frames can not be detected by analysis of the physical layer High fault tolerance of AS-interface compensates those faults Analyser makes preventive diagnostics possible SIMATIC Practice Week Atlanta August 2004 Burns 08.2004 10 Automation and Drives Principle of function - ANALYSER Low Voltage Switchgear MASTER Slave Technical Data Slave Master Configuration Safety at Work AS-i SIGNUM K60 ATEX Analogue modules Analyser Analyser Extension Plug PC SIMATIC Practice Week Atlanta August 2004 RECORD COMMUNICATION: Interpretation Record Represent Document Observe Slave Burns 08.2004 11 Automation and Drives Modes Low Voltage Switchgear Technical Data Master Configuration Safety at Work STATISTICS TRACE AS-i SIGNUM ONLINE ANALYSIS DETAILED Analysis Extension Plug K60 ATEX Analogue modules Analyser Simple Overview Statistic Analysis of Failures Overview of available Slaves Representation of Slave Data and IDs „Complete Installation does not work correctlyWHAT IS THE REASON?“ SIMATIC Practice Week Atlanta August 2004 Setting trigger conditions Observe Communication on these conditions Start the communication record Detailed Analysis of failures with trace filters „SIMON with sporadic E-STOPS - WHY?“ Burns 08.2004 12 Automation and Drives Statistic mode: network overview Low Voltage Switchgear Technical Data Master Configuration Safety at Work AS-i SIGNUM Extension Plug K60 ATEX Analogue modules Analyser The error rate of available slaves is represented in a simple traffic light function: < 1% Faults per second 1..5 % Faults per second > 5 % Faults per second Slave not projected but present SIMATIC Practice Week Atlanta August 2004 Burns 08.2004 13 Automation and Drives Statistic mode: network overview with hold time Low Voltage Switchgear Technical Data Master Configuration Safety at Work AS-i SIGNUM Extension Plug K60 ATEX Same look and functionality as network overview Adjustable hold time for faults After this hold time, the error rate is evaluated again Changes in the system are immediately visible Analogue modules Analyser SIMATIC Practice Week Atlanta August 2004 Burns 08.2004 14 Automation and Drives Satistic mode: data Low Voltage Switchgear Technical Data Master Configuration Safety at Work AS-i SIGNUM Extension Plug K60 ATEX Analogue modules Analyser All data actually transferred over the network is Representation without PLC/Host possible Outputs displayed as process image or as AS-Interface SIMATIC Practice Week Atlanta August 2004 displayed level Burns 08.2004 15 Automation and Drives Statistic mode: configuration Low Voltage Switchgear Technical Data Master Configuration Safety at Work AS-i SIGNUM Extension Plug K60 ATEX Analogue modules Analyser The I/O- and ID-Codes of the slaves are SIMATIC Practice Week Atlanta August 2004 represented Burns 08.2004 16 Automation and Drives Statistic mode: advanced statistics Low Voltage Switchgear Technical Data Master Configuration Safety at Work AS-i SIGNUM Extension Plug K60 ATEX Analogue modules Analyser The data of the overview function is here. SIMATIC Practice Week Atlanta August 2004 represented numerically Burns 08.2004 17 Automation and Drives TRACE mode: Procedure Low Voltage Switchgear Enter trigger conditions Technical Data Enter Record filter Master Configuration Safety at Work Offline Supervision of the system AS-i SIGNUM Extension Plug RECORDING K60 ATEX Analogue modules Download Trace on PC Analyser Enter View-Filter ANALYSIS SIMATIC Practice Week Atlanta August 2004 Burns 08.2004 18 Automation and Drives Trace mode: trigger conditions Low Voltage Switchgear Trigger Levels Initiating Trigger Protocol Initiating data Technical Data Master Configuration Safety at Work AS-i SIGNUM Extension Plug K60 ATEX Analogue modules Analyser Initiating slave SIMATIC Practice Week Atlanta August 2004 Number of trigger conditions before the next trigger level is activated Burns 08.2004 19 Automation and Drives Trace mode: recording Low Voltage Switchgear Technical Data Master Configuration Safety at Work AS-i SIGNUM Extension Plug K60 ATEX Analogue modules Analyser Recording is started independently from the PC. Recording can be analysed offline exactly with extensive view The trigger position (start of recording) is variable SIMATIC Practice Week Atlanta August 2004 filters. Burns 08.2004 20 Automation and Drives Test Protocols Low Voltage Switchgear All data of the online statistics can be printed out as Test protocol sheets Technical Data The qualitiy of AS-Interface networks can thereby be documented Master Configuration Safety at Work This allows a verification of the system state for releases or maintenance AS-i SIGNUM Extension Plug K60 ATEX Analogue modules Analyser SIMATIC Practice Week Atlanta August 2004 Burns 08.2004 21 Automation and Drives Advantages / Benefits Low Voltage Switchgear Technical Data Master Configuration Safety at Work AS-i SIGNUM Extension Plug K60 ATEX Analogue modules Analyser The AS-interface analyser allows preventive inspections and therefore maintenance time and down time is reduced considerably Fast fault repair is rendered possible by the intuitive representation in the statistical mode Simple and comfortable use makes diagnostics of AS-interface networks possible without a specialist Inspection sheets give a verification of the state and quality of the system for service and release Recorded test protocol sheets make remote diagnostics easier by Technical Assistance. Furthermore, any settings of the analyser can be sent in one file per e-mail, whereby outstanding remote diagnostics are achieved Numerous view filters and trigger functions with physical inputs and outputs make a detailed analysis possible Process Data is visible online and commissionings are thereby accelerated, as it is possible to commission independently of host SIMATIC Practice Week Atlanta August 2004 Burns 08.2004 22 Automation and Drives Technical Data Low Voltage Switchgear Interfaces AS-Interface RS 232 for interconnection with PC Trigger input (24 V) Trigger output (TTL) Displays / LEDs LED green (power) Supply voltage OK LED green (serial active) RS232 interface in operation LED green/red (test) Message buffer 256,000 AS-Interface-messages Technical Data Master Configuration Safety at Work AS-i SIGNUM Extension Plug K60 ATEX Analogue modules Analyser Test mode Rated operational current Rated insulation voltage EMC Ambient air temperature Storage temperature AS-Interface-specification SIMATIC Practice Week Atlanta August 2004 about 70 mA out of AS-Interface > 500 V according to EN50081-2, EN61000-6-2 0°C … +55°C -25°C … +70°C V2.1 Burns 08.2004 23 Automation and Drives Schedule / Ordering data Low Voltage Switchgear Technical Data Master Configuration AS-INTERFACE ANALYSER: RS232-cable for interconnection with PC Diagnostics software (CD-ROM) Safety at Work AS-i SIGNUM Extension Plug K60 ATEX Analogue modules Analyser Order number: List price: $1750.00 3RK1904-3AB00 ACCESSORIES: AS-Interface branch M12 3RX9801-0AA00 List Price: $13.20 Cable plug M12 (5m) 3RX1672 List Price $15.60 SIMATIC Practice Week Atlanta August 2004 Burns 08.2004 24