Notifier ID3K Sales Presentation (5.0 MB PPT)

advertisement
ID3000
2 to 8 Loop Intelligent
Fire Alarm Panel
Applications
• Medium To Large Single/Multiple
Building Systems
• Retrofit And New Construction
• Standalone Systems
• Networked Systems
Hardware
Overview
Modular Design
Basic
Equipment Kit
Cover(s)
Extension Chassis
(if required)
Backbox(es)
Optional Expansion
Modules (if required)
Power Supply
Key Components
Backbox
Power Supply
& Batteries
Basic Equipment Kit
& Extension Chassis
Covers
Basic Equipment
Kit
Expansion Cards
Processor
PCB
Main
Chassis
Base Card
Display PCB
Basic Equipment
Kit
Extension Options
• Up to 3 Standard Loop
Cards (LIB)
• Up to 3 Enhanced Loop
Cards (E-LIB)
• One RS-232 Card
• One RS-485 Card
• One ID-Net Card
BEK - Inputs &
Outputs
• Outputs
• A/B/C/D - Sounder or Relay programmable
• Sounder - rated @ 1A/30V each
• Dry contact relay - rated @ 1A/30V
• Fault and Fire Relays VF rated @ 1A/30V each
• Auxiliary 26-28Vdc outputs 1 and 2 both rated @ 1A
• Battery charger max 8.6A (130Ah batteries) when used
remotely.
BEK - Inputs &
Outputs
• Inputs
• Mains - 230Vac ± 15% 50/60 Hz
• Two addressable loops - 500mA/Loop
• Tamper switch input (VF dry contact)
• Communications
• RS232 Port 1
• PC Programming, internal printer option
• RS232 Port 2 (optional module)
• RS485 Port (optional module)
Extension Chassis
Options
Extension Chassis
with 64 Zone Display
Module Kit
(with or without Printer)
Double Extension Chassis
with 255 Zone Display
Module Kit
Extension Chassis
with PRN2000
Printer Module Kit
Extension Cover
Blanking Plate
Optional Expansion
Modules
ID-Net
Network Card
Printer
Module Kit
Isolated RS232
Module Kit
Isolated RS485
Module Kit
Dual Loop
Module Kit
Enhanced Dual
Loop Module Kit
Communication
Modules
• RS232 Card Option
•
•
•
•
Isolated port
Third party interface
External printer
UniNet (NION)
connection
• Pager interface
• VDU for terminal
emulation
• RS485 Card Option
•
•
•
•
Isolated
Master/Slave network
Repeaters
Mimics
Standard LIB Vs
E-LIB
• LIB
• E-LIB
• Handles communication
only
• System CPU scans loops
• In case of main CPU
failure
all detection is lost
• Max. 512 devices per
panel (EN54)
• Powerful microprocessor
• Degrade mode
• In case of main CPU
failure the E-LIB will still
activate sounder circuits
1-4 and the Fire Relay
when an alarm is
received from the loop
• Full 1584 device count
on the panel (EN54)
Power Supply
Selection
Power Supply Unit Kit
2.5 Amp
Remote Battery/Charger
Enclosure Kit
+
Universal PSU Kit
4.5A or 7.0A
(External enclosure
or deep boxes only)
PSU DTP
Booster Kit
(4.5 or 7.0A PSU only)
Power Supply
Options
2.5A PSU
mounts on
the side of
the BEK
DTP Booster
mounts on
the side of
the BEK
4.5A PSU
mounts into
the deep
(extended)
back box
7A PSU
mounts into
the external
charger/
battery
enclosure
Back box Options
Flush Mounting Bezels
Standard
Back Box Kit
Backbox Extension Kit
(available in ‘standard’ and ‘deep’)
Extended Back Box Kit
(available in ‘standard’ and ‘deep’)
Double Extended Backbox Kit
(available in ‘standard’ and ‘deep’)
Backbox Options
12Ah
17Ah
17 Ah
Standard
depth
38Ah
Deep Boxes
Standard
38Ah
Extended
78Ah
Double Extended
External Box
Cover/Door Kits
Security Door Kits
(available for main &
extension covers)
Main Cover Kit
(High Security option)
Extension Cover
Blanking Plate
Extension Cover Kit
(High Security option)
Double Extension Cover Kit
19” Rack
Mounting Option
•
•
•
•
•
•
•
•
•
•
19” Rack Mounting Assembly for Basic
Equipment Kit
6U x 19” Rack Mounting Assembly for 7A PSU
6U x 19” Rack Mounting Assembly for 64 Zone
LED Extension Chassis & Printer Kit
6U x 19” Rack Mounting Assembly for 256 Zone
LED Extension Chassis Kit
6U x 19” Rack Mounting Assembly for Printer
3U x 19” Rack Blank Cover with Mains
Termination Kit
6U x 19” Rack Blank Cover with Mains
Termination Kit
3U x 19” Rack Mounting Assembly for Mimic
Driver Kit
6U x 19” Rack Blank Cover
3U x 19” Rack Blank Cover
Main User
Interface
6 Line x 40
Character
Graphic LCD
Main
Control
Switches
Navigation
Keypad
Numeric
Data Entry
&
Enter/Cancel
System
Status
Indicators
Key switch
Access Level 2
Main User
Interface
• Fully EN54 compliant
• Simple tabbed menu navigation
• Prioritised event display
(Automatically displays highest priority event)
• User in control… has choice
of what is displayed
• Simple lights and switches for
common controls
• Top level info displayed
Graphic Display
•
•
•
•
Large 240 x 64 pixel LCD 6 lines x40 characters
Short-cuts for test & disablement
Selection by direct addressing
Displays:
•
•
•
•
Time and Date
Active Point Count for each event
Event type, index and actions
Panel, Zone and Device descriptors
Graphic Display
System Information on Windows Style Tabbed Screens
Virtual Keyboard
Panel and Zone Text up to 32 Characters via Keyboard
 to Navigate and  to Select
Fire Alarm
Display
Example - 3 Zones in Alarm:
2 Devices Alarmed in Zone 2
1 Device Alarmed in Zone 1
1 other zone in Alarm - Press “Zones in Alarm” to view others
Use Navigation keys  to scroll through zones and display other devices, date/time of event and device % value,
etc.
Short-cut key  selects either device or zone disablement.
Fault Display
3 Zones are in FAULT with 4 events in the system.
Use to scroll through zones and  to display
device, type, value, etc.
Disablement
Display
142 Devices Disabled in 3 input zones. 12 devices are disabled in Zone 2 (all
input devices).
No outputs are disabled. Use to scroll through zone list and  to see
device details.
Main Features
• Meets EN54 Parts 2 and 4
• Degraded mode of operation
• Enhanced LIB (parallel CPUs)
• Menu driven point/data access
• Multi-level operator password control
• Multiple language options
Key Functions
•
•
•
•
•
•
•
•
9 sensitivity levels for Fire & Pre-alarm
Adjustable alarm & fault verification delay
Two-stage alarm operation
Alarm silence/re-sound
Sound general alarm (Evacuate)
Day and Night modes
Fire output(s) inhibit
Internal and external printer options
Key Functions
•
•
•
•
•
•
•
•
Powerful Control-by-Event (CBE)
Auto-Learn or PC programming
Duplicate address detection
One-man Walk Test with counter
Output device test
Daily high test
2 pulse rates for outputs
Time of day functions
System Capacity
Stand-Alone
• Up to 8 loops
• 198 (99+99) devices per
loop
• Up to 1584 devices
• Up to 255 zones
• Up to 7A PSU
• Up to 31 repeaters or mimics
• Up to 512 LEDs per
controller
• 600 event history log
System Capacity
Stand-Alone
•
Four sounder circuits (NACs)
•
•
•
Two 24Vdc auxiliary outputs
•
•
•
Rated at 1A each
Two programmable inputs
Fault and Fire relays
•
•
•
•
Rated @ 1A each
Two programmable as VF relays
rated @ 30Vdc/1A
VF rated @ 30Vdc/1A
Two loops as standard
One isolated RS232 port (optional)
One isolated RS485 port (optional)
System Capacity
Interlinked
• Master/Slave interlink
• Up to 32 network nodes
• Maximum 8 panels
• Remainder repeaters and
mimics
• Up to 64 loops in total
• Up to 12,672 devices in total
• Up to 2040 zones in total
• Up to 56A PSU in total
• Max. RS485 bus length of
3000m
Configuration
Tool
•
•
•
•
•
•
•
Windows Operating Systems
Standard Windows features (cut, copy, paste, etc)
On-line error checking
Software protection
EN54 Network functions
Easy report printouts
Multi-lingual operation
On-Site
Configuration
• Multi-level password/key-switch access
• Level 2: Code 1/Keyswitch - Panel controls & menus
• Level 3: Code 2 - Level 2 + Configuration menus
• Level 3A: Code 3 - Level 3 + Advanced Configuration
•
•
•
•
•
•
Panel settings
Auto-learn facility
Loop/Device configuration
Text Editor (Virtual keyboard)
Control matrix editor (512 lines)
Network configuration
Download