SG-CE Series 60-120 kVA ® PurePulse Sales presentation TYPICAL APPLICATIONS 2 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt Typical applications Designed for mission critical applications, with highest levels of protection and reliability Transportation Finance institution Security system Medical equipments & healthcare facilities SG-CE Series Pure Pulse® Data centers Infrastructure 3 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt CHARACTERISTICS & PERFORMANCES 4 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt Product range CE Marked, 3x380/400/415V In & Out, 50/60Hz UPS SG-CE Series 60kVA PurePulse® 54kW UPS SG-CE Series 80kVA PurePulse® IGBT 72kW rectifier 60 – 80 kVA UPS SG-CE Series 100kVA PurePulse® 90kW IGBT rectifier ® UPS SG-CE Series 120kVA PurePulse 108kW 100 – 120 kVA 5 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt Double conversion technology Designed for Mission Critical Applications Bypass supply True On-Line Double Conversion VFI technology Voltage and Frequency Independent Inverter output transformer for load galvanic separation Rectifier Rectifier supply AC Inverter DC Load AC DC Battery bank SG CE classification: VFI – SSS – 111 VFI Static bypass Voltage & Frequency Independent Frequency Converter operation available Class 1 SS Output voltage THD < 8% for all loads THDv < 1.5% linear loads THDv < 3% non-linear loads 111 Class 1 performance Exceeding Class 1 ‘’Best in Class’’ dynamic response: +/- 3% at load step: 0-100%-0 +/- 2% at load step: 0-50%-0 SG-CE Series 6 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt UPS configuration Double conversion with inverter output isolation transformer Q2 MANUAL BYPASS SSM K6 Q4 RECTIFIER INVERTER Q1 K7 LOADS INPUT MAINS AUTOMATIC BYPASS INVERTER TRANSFORMER K3 BATTERY Double conversion (VFI) technology with output isolation transformer Automatic bypass for overloads, short circuit and UPS disturbances conditions Manual bypass for UPS maintenance operations without load interruption Protection safety devices integrated - back feed protection K6 standard - battery contactor K3 standard SG-CE Series 60-120 kVA PurePulse® 7 Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt Compact design True front access for operation and maintenance, saving installation space Reduced footprint Compact design saving space in installation - 60-80 kVA: 650 x 850 x 1900 mm -100-120 kVA: 835 x 850 x 1900 mm - EMI cabinet: 350 x 850 x 1900 mm Easier to handle in narrow space 1900 850 True front access Installation against a wall More space available for other equipments 650-835 UPS 850 1.600 Reduced weight Easier to handle into installation site (e.g. transportation through floors by lift) Reduced installation time and cost 8 154 W/ 154 kW/m2 835 Footprint SG-CE 120kVA UPS : 0.835 x 0.850 = 0.70 sqm Operational : 0.835 x 1.600 = 1.33 sqm SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt Highest UPS output power capability Capability to supply Inductive, Resistive and Capacitive loads Full range power capability Designed to supply real power for any type of application - inductive loads - resistive loads - capacitive loads I.e. SG-CE 120kVA load capabilities: Inductive load PF=0.9 108 kW / 120 kVA Resistive load PF=1 108 kW / 108 kVA Capacitive load PF=0.9 108 kW / 120 kVA No over-sizing required to supply resistive and capacitive loads Suitable for modern power supply application with unit or capacitive power factor (e.g. new servers generation), crest factor up to 3:1 9 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt Input rectifier performances Wide input window to preserve battery autonomy and lifetime Input window Wide input voltage and frequency windows Limited use of battery Preserve battery autonomy for real input mains failures Increase battery lifetime Input frequency +10% 50 Hz -10% -15% 400V +15% Input voltage Soft start Rectifier can be activated gradually, controlling the input current Preventing instable situation for GenSet Avoids false trip of upfront protection devices Sequential softstart for parallel UPS 10 Soft start UPS input current UPS 1 100% UPS 2 0% time SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt Backfeed protection IEC 62040-1 : ……“For fixed installation UPS, backfeed protection may be provided internally or externally to the UPS in the a.c. input line” Standard feature inside UPS cabinet No additional cost required No addition installation required Backfeed contactor static bypass Fully compliant with IEC 62040-1 Compliance to UPS installation safety requirements Input mains Rectifier Inverter DC AC DC Safer operating condition Safer operation for end users and service engineers Load AC Battery bank preventing feedback to the mains from the inverter in case of mains failure and a fault in the bypass circuit 11 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt IGBT technology for clean input Pure Pulse® configuration for highest input performances UPS input performances Total Current Harmonic Distortion THDi=2% UPS input power factor: 0.99 PurePulse® technology for IGBT rectifier Constant behavior at all loads Negligible harmonics contents at full and partial loads Total Input Harmonic Distortion 5% 4% THDi Benefit on input mains Saving in the sizing of upfront equipments e.g. GenSet, cablings, circuit breakers, … No disturbances to nearby equipment Saving cost due to additional filters 3% 2% 1% 0% 0% 12 20% 40% 60% Load 80% 100% SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt Perfect integration with GenSet No GenSet oversizing required GenSet integration Compatible with GenSet design Saving GenSet size (suggested GenSet vs. UPS ratio ~ 1.1) Reducing GenSet installation space Saving GenSet investment GenSet system integration GenSet integration via Customer Interface (dedicated auxiliary contact) Programmable functions based on GenSet working condition (Gen on/off) Example Load UPS 120 kVA; PF=0.8; 96 kW SG 120 kVA Pure Pulse®; input PF = 0.99 GenSet data reactance subtr. X“d=12% GenSet size min. size required 132 kVA GenSet/UPS = 132/120 = 1.1 SG-CE Series 60-120 kVA PurePulse® 13 Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt Superior Battery Management Safe and protected battery management to preserve investment and UPS reliability Charging voltage = f (battery temperature) 2.36 2.33 Volt per cell Flexible applications Different battery technologies applicable: PB sealed (VRLA) - PB vented – NiCd Wide autonomy range: few minutes …... hours 2.30 2.27 2.24 2.21 2.18 User friendly information Prediction of true back-up time, based on load status Alarm for “stop operation” to prevent any unknown shut-down 0 5 10 15 20 25 30 35 40 Battery tem perature [°C] Voltage temperature compensation Monitoring and control Battery test (programmable or manual) ; preserve UPS system reliability Battery earth fault detection; safer operation for service engineer & end user 14 V SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt No output voltage distortion Best in class inoutput dynamic stiffness Output voltage with linear + non-linear load No output voltage distortion with linear and non-linear loads Voltage distortion - linear loads: THDv <1.5% - non-linear loads: THDv < 3% Enhanced customer productivity Improved quality of application, reducing stress for loads supplied Increased uptime and MTBF of customer Reduced service intervention (e.g. medical applications: ~60% labor hour & spare parts reduction) 15 output voltage current Output voltage with non-linear load output voltage current SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt Output Dynamic Stiffness Best in class inoutput dynamic stiffness Medical scanner - dynamic current absorbtion Best in class in output voltage variation with load steps: Static : < + 1% Dynamic at load steps 0-50-0% : < + 2% Dynamic at load steps 0-100-0% : < + 3% Enhanced customer unit productivity Improved quality of application (i.e. medical images) Capability to supply critical loads with high and fast loads steps (pulsating loads) Increased uptime and MTBF of customer Reduced service intervention 1 ms Voltage variation at 0–100% load step load step 0-100% output voltage 16 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt Control panel Easy and intuitive interface Back lit Graphic Display (LCD) Multilanguage communication interface: English, German, Italian, Spanish, French, Finnish, Polish, Portuguese, Czech, Slovakian, Chinese, Swedish, Russian and Dutch Synoptic diagram indicating UPS status Command keys and parameters setting UPS status control LED LED - red Stop Operation LED - yellow Alarm LED - green Operation 17 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt EFFICIENCY 18 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt High Efficiency at all loads Reduced customer operation costs and cost saving in air conditioning design High efficiency performances at any load High efficiency at full and partial loads for real benefit in operating conditions SG CE PurePulse® rectifier – Efficiency 100% 92% 80% Efficiency % Energy cost saving Reduced cost of customer equipment operation at all loads Air conditioning cost saving Reducing size and cost of air condition system Reducing consumption and related operating cost 60% Typical Operation 40% 20% 0% 10% 25% 50% 75% 100% Load 19 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt Super Eco Mode - functionality Improving UPS efficiency Normal mode Normal mode The output voltage is newly generated, independently from the input voltage Heat losses are present in rectifier and inverter Bypass supply Static bypass Rectifier Rectifier supply AC Inverter DC Load AC DC Battery bank Super Eco Mode Load is supplied via the bypass UPS rectifier keeps the battery charged UPS inverter switched off (no heat losses) Super Eco Mode Bypass supply Static bypass Rectifier Rectifier supply AC Inverter DC DC Transf. Load AC Battery bank 20 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt Super Eco Mode - benefit High efficiency, preserving protection to critical load < 2ms High efficiency: 98% prevents heat losses saving customer utility bill Fast transfer time to inverter: <2 ms Guaranteed safe energy for the application Output voltage Bypass on/off Inverter current Configurable according to load requirement Adjustable bypass supply tolerance - voltage: +/- 10% (adjustable) - frequency: +/- 5% (adjustable) Inverte r control 21 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt RPA 22 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt Redundant Parallel Architecture True redundancy with no single point of failure Modular design Future system expansion Saving investment Input mains rectifier AC True redundancy No single point of failure Decentralized bypass Distributed parallel management system bypass rectifier AC DC battery DC battery DC DC AC Increased system reliability Safe and reliable power supply for “mission critical applications” Increase productivity True redundancy with no single point of failure 23 bypass AC critical load SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt Redundant Parallel Architecture Increase system reliability for Mission Critical Applications Configurable up to 6 units in parallel Future expansion Safe and reliable power supply Redundant Communication Bus Easy to install and maintain Easy system upgrade/downgrade Maintenance operation without load interruption utility supply redundant communication buses 24 critical load SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt EMC 25 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt EMC - Electro Magnetic Compatibility IEC 62040-2 standard defines the limits of maximum allowable levels of emission of electromagnetic disturbances for UPS systems Emission Any electronic devices emits electromagnetic disturbances - radio frequency waves - through: - cables (CE: conducted emissions) - air (RE: radiated emissions) Immunity All electronic equipment is sensitive for electromagnetic waves. These waves can disturb the functions of these equipments Electro Magnetic Compatibility Disturbances tolerance among different types of equipment when running in the same environment. 26 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt EMC - Immunity Immunity SG-CE products design exceed IEC 62040-2 C3 level for immunity, i.e. can withstand possible disturbances and noise without affecting standard working conditions Immunity SG-CE immunity level IEC requirements ESD 15kV (air) 8kV (contact) 8kV (air) 4kV (contact) Surge 2kV line to line 4kV line to earth 1kV line to line 2kV line to earth Burst 4kV @5kHz 2kV @5kHz RF common mode (1kHz) 10V 10V Surge suppressors mounted standard in UPS cabinet 27 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt EMC Category C2 (Class A), optional feature* Compensation of radio-frequency emission to avoid distrurbances on nearby equipments No interference with other equipments Avoid any interferences with critical applications sensitive to radio frequency emission (e.g. telecom, broadcasting, …) No additional investment required for EMC investigation. Standard limit Measurement data Protected unit quality enhancement Increased quality and productivity (e.g. Image quality in medical application) SGSE_1 Standard limit 00-120_ S1_UPS +EMC_G E_02 Measurement data *Additional EMC cabinet required 28 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt SERVICEABILITY 29 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt Designed for serviceability Saving time and cost in service Easy maintenance interventention Reducing time and cost on maintenance intervention Reducing down-time, increasing availability Easy access to inverter/rectifier/bypass bridge 30 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt POWER QUALITY SYSTEMS 31 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt Power Quality Systems Integretion with other Power Quality euipments for Mission Critical Applications UPS: Uninterruptible Power Supply ISM: Intelligent Synchronization Module STS: Static Transfer Switch BatteryB BatteryA ISM_Cabinet_GE_01 ISM UPS-B TM UPS-A STS-B STS-A Load-B Load-A 32 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt INTEGRATION WITH BMS 33 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt Customer interface Easy integration with Building Management System (BMS) Customer interface UPS supervision capability 1x RS232 Serial Communication Port 6 programmable potential free alarm contacts: - D plug - Terminals blocks 1x Emergency Power OFF contact 1x Gen-ON Input contact 1x Control Input contact Additional interface: SNMP Interface Card (10/100Mbps auto-select) MODBUS RTU Interface (RS232 or RS485) 34 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt CONNECTIVITY 35 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt GE Power Diagnostics Remote monitoring and diagnostics solution SNMP/Modem/GPRS topologies available Flexible, safe and customer-friendly solution for remote monitoring Secure communication via: e-mail, SMS, fax GPRS Web/PDA Data Acquisition Communication Medium 36 IRIS Infrastructure User Interface SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt 37 SG-CE Series 60-120 kVA PurePulse® Sales presentation SAP_SGS_XCE_60K_M12_1GB_V010.ppt