SG-CE Series 60-120kVA S1

advertisement
SG-CE Series 60-120 kVA
®
PurePulse
Sales presentation
TYPICAL
APPLICATIONS
2
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
Typical applications
Designed for mission critical applications, with highest levels of protection and
reliability
Transportation
Finance institution
Security system
Medical equipments
& healthcare facilities
SG-CE Series Pure
Pulse®
Data centers
Infrastructure
3
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
CHARACTERISTICS
&
PERFORMANCES
4
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
Product range
CE Marked, 3x380/400/415V In & Out, 50/60Hz
UPS SG-CE Series 60kVA PurePulse® 54kW
UPS SG-CE Series 80kVA PurePulse®
IGBT
72kW rectifier
60 – 80 kVA
UPS SG-CE Series 100kVA PurePulse® 90kW
IGBT
rectifier
®
UPS SG-CE Series 120kVA PurePulse 108kW
100 – 120 kVA
5
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
Double conversion technology
Designed for Mission Critical Applications
Bypass
supply
True On-Line Double Conversion
 VFI technology
Voltage and Frequency Independent
 Inverter output transformer for load
galvanic separation
Rectifier
Rectifier
supply
AC
Inverter
DC
Load
AC
DC
Battery bank
SG CE classification: VFI – SSS – 111
VFI
Static bypass
Voltage & Frequency Independent
Frequency Converter operation available
Class 1
SS
Output voltage THD < 8% for all loads
THDv < 1.5%
linear loads
THDv < 3%
non-linear loads
111
Class 1 performance
Exceeding Class 1
‘’Best in Class’’ dynamic response:
+/- 3% at load step: 0-100%-0
+/- 2% at load step: 0-50%-0
SG-CE
Series
6
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
UPS configuration
Double conversion with inverter output isolation transformer
Q2
MANUAL BYPASS
SSM
K6
Q4
RECTIFIER
INVERTER
Q1
K7
LOADS
INPUT MAINS
AUTOMATIC BYPASS
INVERTER
TRANSFORMER
K3
BATTERY




Double conversion (VFI) technology with output isolation transformer
Automatic bypass for overloads, short circuit and UPS disturbances conditions
Manual bypass for UPS maintenance operations without load interruption
Protection safety devices integrated
- back feed protection K6 standard
- battery contactor K3 standard
SG-CE Series 60-120 kVA PurePulse®
7
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
Compact design
True front access for operation and maintenance, saving installation space
Reduced footprint
 Compact design saving space in installation
- 60-80 kVA:
650 x 850 x 1900 mm
-100-120 kVA:
835 x 850 x 1900 mm
- EMI cabinet:
350 x 850 x 1900 mm
 Easier to handle in narrow space
1900
850
True front access
 Installation against a wall
 More space available for other equipments
650-835
UPS
850
1.600
Reduced weight
 Easier to handle into installation site
(e.g. transportation through floors by lift)
 Reduced installation time and cost
8
154 W/
154 kW/m2
835
Footprint SG-CE 120kVA
UPS
: 0.835 x 0.850 = 0.70 sqm
Operational : 0.835 x 1.600 = 1.33 sqm
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
Highest UPS output power capability
Capability to supply Inductive, Resistive and Capacitive loads
Full range power capability
 Designed to supply real power for any
type of application
- inductive loads
- resistive loads
- capacitive loads
I.e. SG-CE 120kVA load capabilities:
Inductive load PF=0.9 108 kW / 120 kVA
Resistive load PF=1
108 kW / 108 kVA
Capacitive load PF=0.9 108 kW / 120 kVA
 No over-sizing required to supply
resistive and capacitive loads
 Suitable for modern power supply
application with unit or capacitive
power factor (e.g. new servers
generation), crest factor up to 3:1
9
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
Input rectifier performances
Wide input window to preserve battery autonomy and lifetime
Input window
Wide input voltage and frequency
windows
 Limited use of battery
 Preserve battery autonomy for real
input mains failures
 Increase battery lifetime
Input
frequency
+10%
50 Hz
-10%
-15%
400V
+15%
Input voltage
Soft start
 Rectifier can be activated gradually,
controlling the input current
 Preventing instable situation for GenSet
 Avoids false trip of upfront protection
devices
 Sequential softstart for parallel UPS
10
Soft start
UPS input current
UPS 1
100%
UPS 2
0%
time
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
Backfeed protection
IEC 62040-1 : ……“For fixed installation UPS, backfeed protection may be
provided internally or externally to the UPS in the a.c. input line”
Standard feature inside UPS cabinet
 No additional cost required
 No addition installation required
Backfeed contactor
static bypass
Fully compliant with IEC 62040-1
 Compliance to UPS installation safety
requirements
Input
mains
Rectifier
Inverter
DC
AC
DC
Safer operating condition
 Safer operation for end users and
service engineers
Load
AC
Battery bank
preventing feedback to the mains from the
inverter in case of mains failure and a fault
in the bypass circuit
11
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
IGBT technology for clean input
Pure Pulse® configuration for highest input performances
UPS input performances
 Total Current Harmonic Distortion THDi=2%
 UPS input power factor: 0.99
PurePulse® technology for IGBT
rectifier
Constant behavior at all loads
 Negligible harmonics contents at full and
partial loads
Total Input Harmonic Distortion
5%
4%
THDi
Benefit on input mains
 Saving in the sizing of upfront equipments
e.g. GenSet, cablings, circuit breakers, …
 No disturbances to nearby equipment
 Saving cost due to additional filters
3%
2%
1%
0%
0%
12
20%
40%
60%
Load
80%
100%
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
Perfect integration with GenSet
No GenSet oversizing required
GenSet integration
Compatible with GenSet design
Saving GenSet size
(suggested GenSet vs. UPS ratio ~ 1.1)
Reducing GenSet installation space
Saving GenSet investment
GenSet system integration
GenSet integration via Customer Interface
(dedicated auxiliary contact)
Programmable functions based on GenSet
working condition (Gen on/off)
Example
Load
UPS
120 kVA; PF=0.8; 96 kW
SG 120 kVA Pure Pulse®;
input PF = 0.99
GenSet data reactance subtr. X“d=12%
GenSet size min. size required 132 kVA
GenSet/UPS = 132/120 =
1.1
SG-CE Series 60-120 kVA PurePulse®
13
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
Superior Battery Management
Safe and protected battery management to preserve investment and UPS
reliability
Charging voltage = f (battery temperature)
2.36
2.33
Volt per cell
Flexible applications
 Different battery technologies applicable:
PB sealed (VRLA) - PB vented – NiCd
 Wide autonomy range: few minutes …...
hours
2.30
2.27
2.24
2.21
2.18
User friendly information
 Prediction of true back-up time, based
on load status
 Alarm for “stop operation” to prevent
any unknown shut-down
0
5
10
15
20
25
30
35
40
Battery tem perature [°C]
Voltage temperature compensation
Monitoring and control
 Battery test (programmable or manual) ;
preserve UPS system reliability
 Battery earth fault detection; safer
operation
for service engineer & end
user
14
V
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
No output voltage distortion
Best in class inoutput dynamic stiffness
Output voltage with linear + non-linear
load
No output voltage distortion with linear and
non-linear loads
 Voltage distortion
- linear loads:
THDv <1.5%
- non-linear loads:
THDv < 3%
Enhanced customer productivity
 Improved quality of application, reducing
stress for loads supplied
 Increased uptime and MTBF of customer
 Reduced service intervention
(e.g. medical applications: ~60% labor
hour &
spare parts reduction)
15
output voltage
current
Output voltage with non-linear load
output voltage
current
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
Output Dynamic Stiffness
Best in class inoutput dynamic stiffness
Medical scanner - dynamic current
absorbtion
Best in class in output voltage variation with
load steps:
Static
: < + 1%
Dynamic at load steps 0-50-0%
: < + 2%
Dynamic at load steps 0-100-0% : < + 3%
Enhanced customer unit productivity
Improved quality of application
(i.e. medical images)
Capability to supply critical loads with high and
fast loads steps (pulsating loads)
Increased uptime and MTBF of customer
Reduced service intervention
1
ms
Voltage variation at 0–100% load step
load step 0-100%
output voltage
16
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
Control panel
Easy and intuitive interface
Back lit Graphic Display (LCD)
 Multilanguage communication interface:
English, German, Italian, Spanish, French,
Finnish, Polish, Portuguese, Czech,
Slovakian, Chinese, Swedish, Russian and
Dutch
 Synoptic diagram indicating UPS status
 Command keys and parameters setting
 UPS status control LED
LED - red
Stop
Operation
LED - yellow
Alarm
LED - green
Operation
17
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
EFFICIENCY
18
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
High Efficiency at all loads
Reduced customer operation costs and cost saving in air conditioning design
High efficiency performances at any load
High efficiency at full and partial loads for
real benefit in operating conditions
SG CE PurePulse® rectifier –
Efficiency
100%
92%
80%
Efficiency %
Energy cost saving
Reduced cost of customer equipment
operation at all loads
Air conditioning cost saving
Reducing size and cost of air condition
system
Reducing consumption and related
operating cost
60%
Typical
Operation
40%
20%
0%
10%
25%
50%
75%
100%
Load
19
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
Super Eco Mode - functionality
Improving UPS efficiency
Normal mode
Normal mode
The output voltage is newly generated,
independently from the input voltage
Heat losses are present in rectifier and
inverter
Bypass
supply
Static bypass
Rectifier
Rectifier
supply
AC
Inverter
DC
Load
AC
DC
Battery bank
Super Eco Mode
Load is supplied via the bypass
UPS rectifier keeps the battery
charged
UPS inverter switched off
(no heat losses)
Super Eco Mode
Bypass
supply
Static bypass
Rectifier
Rectifier
supply
AC
Inverter
DC
DC
Transf.
Load
AC
Battery bank
20
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
Super Eco Mode - benefit
High efficiency, preserving protection to critical load
<
2ms
High efficiency: 98%
prevents heat losses
saving customer utility bill
Fast transfer time to inverter: <2 ms
Guaranteed safe energy for the
application
Output voltage
Bypass
on/off
Inverter
current
Configurable according to load
requirement
Adjustable bypass supply tolerance
- voltage: +/- 10% (adjustable)
- frequency: +/- 5% (adjustable)
Inverte
r
control
21
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
RPA
22
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
Redundant Parallel Architecture
True redundancy with no single point of failure
Modular design
Future system expansion
Saving investment
Input mains
rectifier
AC
True redundancy
No single point of failure
Decentralized bypass
Distributed parallel management
system
bypass
rectifier
AC
DC
battery
DC
battery
DC
DC
AC
Increased system reliability
Safe and reliable power supply for
“mission critical applications”
Increase productivity
True redundancy with no single point
of failure
23
bypass
AC
critical load
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
Redundant Parallel Architecture
Increase system reliability for Mission Critical Applications
Configurable up to 6 units in parallel
Future expansion
Safe and reliable power supply
Redundant Communication Bus
Easy to install and maintain
Easy system upgrade/downgrade
Maintenance operation without
load interruption
utility supply
redundant
communication
buses
24
critical load
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
EMC
25
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
EMC - Electro Magnetic Compatibility
IEC 62040-2 standard defines the limits of maximum allowable levels of emission of
electromagnetic disturbances for UPS systems
Emission
Any electronic devices emits electromagnetic
disturbances - radio frequency waves - through:
- cables (CE: conducted emissions)
- air
(RE: radiated emissions)
Immunity
All electronic equipment is sensitive for
electromagnetic waves.
These waves can disturb the functions of these
equipments
Electro Magnetic Compatibility
Disturbances tolerance among different types of
equipment when running in the same
environment.
26
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
EMC - Immunity
Immunity
SG-CE products design exceed IEC 62040-2 C3 level for
immunity, i.e. can withstand possible disturbances and noise
without affecting standard working conditions
Immunity
SG-CE
immunity level
IEC requirements
ESD
15kV (air)
8kV (contact)
8kV (air)
4kV (contact)
Surge
2kV line to line
4kV line to earth
1kV line to line
2kV line to earth
Burst
4kV @5kHz
2kV @5kHz
RF common mode (1kHz)
10V
10V
Surge suppressors mounted standard in UPS cabinet
27
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
EMC Category C2 (Class A), optional feature*
Compensation of radio-frequency emission to avoid distrurbances on nearby equipments
No interference with other equipments
 Avoid any interferences with critical
applications sensitive to radio frequency
emission (e.g. telecom, broadcasting, …)
 No additional investment required for
EMC investigation.
Standard limit
Measurement data
Protected unit quality enhancement
 Increased quality and productivity
(e.g. Image quality in medical application)
SGSE_1
Standard limit
00-120_
S1_UPS
+EMC_G
E_02
Measurement data
*Additional EMC cabinet
required
28
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
SERVICEABILITY
29
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
Designed for serviceability
Saving time and cost in service
Easy maintenance interventention
Reducing time and cost on maintenance intervention
Reducing down-time, increasing availability
Easy access to inverter/rectifier/bypass
bridge
30
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
POWER QUALITY
SYSTEMS
31
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
Power Quality Systems
Integretion with other Power Quality euipments for Mission Critical Applications
UPS: Uninterruptible Power Supply
ISM: Intelligent Synchronization
Module
STS:
Static Transfer Switch
BatteryB
BatteryA
ISM_Cabinet_GE_01
ISM
UPS-B
TM
UPS-A
STS-B
STS-A
Load-B
Load-A
32
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
INTEGRATION WITH BMS
33
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
Customer interface
Easy integration with Building Management System (BMS)
Customer interface
UPS supervision capability
1x RS232 Serial Communication Port
6 programmable potential free alarm
contacts:
- D plug
- Terminals blocks
1x Emergency Power OFF contact
1x Gen-ON Input contact
1x Control Input contact
Additional interface:
SNMP Interface Card
(10/100Mbps auto-select)
MODBUS RTU Interface (RS232 or RS485)
34
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
CONNECTIVITY
35
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
GE Power Diagnostics
Remote monitoring and diagnostics solution
SNMP/Modem/GPRS topologies available
Flexible, safe and customer-friendly solution
for remote monitoring
Secure communication via:
e-mail, SMS, fax
GPRS
Web/PDA
Data
Acquisition
Communication
Medium
36
IRIS
Infrastructure
User
Interface
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
37
SG-CE Series 60-120 kVA PurePulse®
Sales presentation
SAP_SGS_XCE_60K_M12_1GB_V010.ppt
Download