Kia Training Material

advertisement
Hi-Scan Pro Application
Hi-Scan Pro Application
CONTENTS
1. Kia Vehicle Diagnosis
2. Vehicle Scope meter
3. System Setup
4. Optional Items
5. PC-Scan
Hi-Scan Pro Application
1. Kia Vehicle Diagnosis
1.1 DIAGNOSIS TROUBLE CODE
1.2 FREEZE FRAME DATA
1.3 CURRENT DATA
1.4 MONITERING TEST RESULT
1.5 EVAP. LEAKAGE TEST
1.6 FLIGHT RECORD
1.7 DUAL DISPLAY
1.8 SIMU-SCAN
Hi-Scan Pro Application
1.1 DIAGNOSIS TROUBLE CODE ( 1/5)
To get started. Following procedures are within KIA VEHICLE DIAGNOSIS mode
On the Hi-Scan Pro keyboard;
•Press “ON/OFF” button to turn on the Hi-Scan Pro
•Keep on press “Enter” button until Initial screen come up.
•Make sure DLC cable is properly connected.
ENTER

FIRST : SELECT VEHICLE
DIAGNOSIS
ENTER
ENTER

SECOND : SELECT VEHICLE

THIRD : SELECT SYSTEM

FOURTH : SELECT VEHICLE
YEAR
Hi-Scan Pro Application
1.1 DIAGNOSIS TROUBLE CODE (2/5)
To view Diagnostic Trouble code.
ENTER
ENTER
OR

After Selecting the vehicle model
year, go through the Diagnostic
Trouble Code and Current data to
diagnose the vehicle.

If ECM or communication WIRE
has problem, Hi-Scan Pro cannot
communicate with vehicle and
display the message as shown in
picture.
Hi-Scan Pro Application
1.1 DIAGNOSIS TROUBLE CODE (3/5)
To check Diagnostic Trouble Code
ENTER
ENTER
OR

If ECM has no trouble code with
engine system, Hi-Scan Pro display
on the screen
“NO TROUBLE CODE”

If ECM has trouble code with engine
system, Hi-Scan Pro display
“TROBLE CODE WITH ITEM”
Hi-Scan Pro Application
1.1 DIAGNOSIS TROUBLE CODE (4/5)
To get information about DTC and delete DTC

HELP : Basic & Major information to help understand
each trouble code and item

ERAS : Erase Trouble Code(Follow the instruction
carefully)
F1 HELP
F2 ERAS
Hi-Scan Pro Application
1.1 DIAGNOSIS TROUBLE CODE (5/5)
To check the data of sensor with DTC when DTC is occurred.
 FREZ : Display the data of items with DTC at the situation
when trouble is occurred.
 Hi - Scan display “FRZE” data only when ECM support
this function.
 PART : Precise diagnosis for each sensor(Oscilloscope)
F3 FRZE
F6 PART
Hi-Scan Pro Application
1.2 FREEZE FRAME DATA
To check the data of sensor with DTC when DTC is occurred.
Previous menu
ENTER
ENTER
ENTER
Press “ENTER” with the cursor on “02.
FREEZE FRAME DATA” in “1. KIA
VEHICLE DIAGNOSIS” mode.
ENTER
In this case, connect with vehicle via DLC cable.
 FREZ : Display the data of items
ENTER
with DTC at the situation
when trouble is occurred.
 Hi - Scan display “FREZ” data
only when ECM support
this function.
Hi-Scan Pro Application
1.3 CURRENT DATA (1/2)
To view the sensor and actuator data.
Select “CURRENT DATA” in “KIA VEHICLE
DIAGNOSIS” mode.
In this case, connect with vehicle via DLC cable.
ENTER

FIX
: Fix current data and display
on the top of the screen

PART : Precise diagnosis for sensor
with inverted letters(Oscilloscope)

F1 FIX
F2 PART
FULL : Display full 22 items’ data
F3 FULL
Hi-Scan Pro Application
1.3 CURRENT DATA (2/2)
To view the sensor and actuator data.
F4 HELP
F5 GRPH

HELP : Provide reference data

GRPH : Waveform graph display

RCRD : Record sensor data
F6 RCRD
Hi-Scan Pro Application
1.3 CURRENT DATA - PART
To analyze part precisely.
Previous menu
ENTER
ENTER
ENTER
Connect a probe to “CH A” of Hi-Scan Pro
ENTER
•Go through the appropriate mode and press
“ENTER” on “03. CURRENT DATA”.
ENTER
•Press “F2” button to operate “PART”
function.
F2 PART
 PART : Place a box, in which
letters are inverted, and press
“PART” for precise part analysis.
 Connect a Test Probe to Channel
A of Hi-Scan Pro.
 Oscilloscope mode begin as
shown in the picture.
Hi-Scan Pro Application
1.3 CURRENT DATA - GRAPH
Previous menu
To view the pattern of sensor or actuator data
ENTER
ENTER
ENTER
On a “CURRENT DATA” mode, press
“F1” to fix the items and “F5” to view the
graph.
F1 FIX
ENTER
ENTER

FIX : Select the sensors to view “GRAPH”

GRPH : Waveform graph display

FIX : Select the sensors to fix at
the top of the screen.
You can change the sensor by
F5 GRPH
pressing FIX button again.
You can scroll up and down
without moving fixed sensor.
Hi-Scan Pro Application
1.3 CURRENT DATA - RECORD
Previous menu
To record the sensor or actuator data.
ENTER
ENTER
ENTER
ENTER
On a “CURRENT DATA” mode, press
“F6” to record a data.
ENTER

RCRD : Move to “RECORD” mode,
in which select trigger type.

AUTO TRIGGER(ANY DTC) :
Triggers with any DTC.

AUTO TRIGGER(SINGLE DTC) :
Trigger with single user specified
DTC.
F6 RCRD

MANUAL TRIGGER : User trigger
the data recording.

FLIGHT RECORD DATA REVIEW :
Fetch recorded data.
Hi-Scan Pro Application
1.3 CURRENT DATA – AUTO TRIGGER (ANY DTC) (1/2)
Record a data using AUTO TRIGGER.
Previous menu
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
After “TRIGGER TYPE” is chosen,
Select memory location using “▲””▼”
buttons and press enter.
TYPE ID
ENTER
AUTO TRIGGER
(ANY DTC)

ENTER : Select the memory
location then press “ENTER” to
type memory ID.

Type “CAR ID”.

ENTER : Go to “DATA
RECORD” select mode.
ENTER
Select the “DATA RECORD” type
and press “ENTER”.
Hi-Scan Pro Application
1.3 CURRENT DATA – AUTO TRIGGER (ANY DTC) (2/2)
Choose items to record: all or custom.
“01” ENTER
 ALL DATA RECORD
: Record all sensor data
USER SELECT DATA RECORD.
: Record user defined sensor data.
 FIX : Select sensors to record in ‘USER
SELECT DATA RECORD”.
“02” ENTER
 ENTER : Start “RECORDING”
 ESC :”STOP” recording
Hi-Scan Pro Application
1.3 CURRENT DATA – AUTO TRIGGER (SINGLE DTC)
Enter specific DTC which will be used as trigger.
 AUTO TRIGGER(SINGLE DTC)
: Record user defined single DTC.
 Type specific “DTC CODE” and
press “ENTER”.
 Rest of procedures are same as
“AUTO TRIGGER (ANY DTC)”
ENTER
Type DTC CODE
and press ENTER
Hi-Scan Pro Application
1.3 CURRENT DATA – MANUAL TRIGGER (1/2)
User triggers the record data.
 MANUAL TRIGGER
: Place a mark on a recorded data where “ENTER” button
is pressed while recording.
This mark is displayed as vertical line in “GRAPH” mode.
 Next procedures are same as “AUTO TRIGGER”.
 Select “DATA RECORD” type.
ENTER
ENTER
TYPE ID
ENTER
Hi-Scan Pro Application
1.3 CURRENT DATA – MANUAL TRIGGER (2/2)
Choose items to record: all or custom.
“01” ENTER
 ALL DATA RECORD
: Record all sensor data
 ENTER : Place a mark on a data where
“ ENTER” is pressed while
recording.
USER SELECT DATA RECORD.
: Record user defined sensor data.
 FIX : Select sensors to record and press
“02” ENTER
“F1”.
 ENTER : Start “RECORDING”.
 ENTER : Start “TRIGGERING”.
 ESC :”STOP” recording.
Hi-Scan Pro Application
1.3 CURRENT DATA –FLIGHT RECORD VIEW (1/2)
Review recorded data
 FLIGHT RECORD DATA REVIEW
: Review recorded data.
 Select the memory location, then press
“ENTER”.
ENTER
 Press “ENTER” to review recorded data.
Select the memory location
and press “ENTER”
Hi-Scan Pro Application
1.3 CURRENT DATA –FLIGHT RECORD VIEW (2/2)
Select review type.
 GRAP : Covert the “LIST” screen into “GRAPH”.
 LIST : Covert the “GRAPH” screen into “LIST”.
 HOME : Place the triggered position, displayed as
vertical line, at the middle of the screen.
 FIX : You can scroll up and down without moving
fixed item. If you press “FIX” again, you can change
the item to fix.
ENTER
F1 “GRAP”
F1 “LIST”
Hi-Scan Pro Application
1.4 MONITORING RESULTS
To monitor emission related operations
Previous menu
ENTER
ENTER
ENTER
Select “MONITORING TEST RESULT”
in “KIA VEHICLE DIAGNOSIS” mode.
ENTER
In this case, connect with vehicle via
DLC cable.
 MONITORING TEST RESULT
: This function provides 3 tests,
ENTER
which are
1) READINESS TEST
2) HO2S MONITERING TEST
3) OBD2 MONITERING TEST
Hi-Scan Pro Application
1.4 MONITORING RESULTS – READNESS TEST
To monitor emission related operations


ENTER
ENTER
READINESS TEST : Displays vehicle’s onboard monitoring.
: Emission-related operations are monitored.
Test result accurately reflect vehicles’
condition of emission related components.
Hi-Scan Pro Application
1.4 MONITORING RESULTS – HO2S MONITORING TEST
To monitor Oxygen sensor test result.
ENTER



HO2S MONITERING TEST
: display the results of the
Heated Oxygen Sensor
testing performed by the ECM
Hi – Scan pro also displays
test result by converting ECM
data.
The test result is valid only
after ECM’s H2OS monitoring
is finished.
ENTER
ENTER
Hi-Scan Pro Application
1.4 MONITORING RESULTS – OBD2 MONITORING TEST
To monitor OBD2 test.

ENTER

OBD2 MONITORING TEST
: User can access to the on-board
diagnostic monitoring test result of
specific component /system that are not
continuously monitored.
List of OBD monitor applicable for RIO
- Three-way catalyst converter.
- HO2S monitoring.
- EVAP. EM monitoring.
-Thermostat monitoring.
- HO2S heater(B1S1).
- HO2S heater(B1S2).
- ECT Plausibility.
ENTER
ENTER
Hi-Scan Pro Application
Previous menu
1.5 EVAP. LEAKAGE TEST (1/4)
ENTER
ENTER
To inspect EVAP leakage.
ENTER
ENTER
ENTER
Select “EVAP LEAKAGE TEST” in
“KAI VEHICLE DIAGNOSIS”
mode.
In this case, connect with vehicle via
DLC cable.

EVAP. LEAK TEST MODE
: The EVAP. Leakage Test is
based on the diagnosis
F6 HELP
DOWN
module for tank leakage
detection uses an electrically
driven vane pump.

Please follow the Hi-Scan
Pro EVAP. LEAKAGE TEST
process like picture.
Hi-Scan Pro Application
1.5 EVAP. LEAKAGE TEST (2/4)
To inspect EVAP leakage.
ENTER

NORMAL CONDITION OF
EVAP. SYS
:If evap. Sys of vehicle had being
normal, Hi-Scan Pro display O.K of
the test results.
Hi-Scan Pro Application
1.5 EVAP. LEAKAGE TEST (3/4)
To inspect EVAP leakage.
ENTER

ABNORMAL CONDITION OF EVAP. SYS
:If evap. Sys of vehicle had being abnormal,
Hi-Scan Pro display ACTIVATION IS NOT
POSSIIBLE.
ENTER

Please check the vehicle condition according
to Hi-Scan Pro process.
DOWN
Hi-Scan Pro Application
1.5 EVAP. LEAKAGE TEST (4/4)
To inspect EVAP leakage.
ENTER

ABNORMAL CONDITION OF EVAP.
SYS:If you retry EVAP. Leakage test
with-in 5 minutes had finished EVAP.
Leakage test, Hi-Scan Pro will display
NOT NECESSRRY.
Hi-Scan Pro Application
1.6 FLIGHT RECORD – AUTO TRIGGER (1/2)
To record sensor or actuator data.
Previous menu
ENTER
ENTER
ENTER
ENTER
Select “FLIGHT RECORD” in “KIA
VEHICLE DIAGNOSIS” mode.
ENTER
In this case, connect with vehicle with
DLC cable.
AUTO TRIGGER
(ANY DTC)
ENTER
TYPE ID

ENTER : Select the memory
location then press “ENTER” to
type memory ID.

Type “CAR ID”.

ENTER : Go to “DATA
RECORD” select mode.
Select the “DATA RECORD” type
and press “ENTER”.
Hi-Scan Pro Application
1.6 FLIGHT RECORD – AUTO TRIGGER (2/2)
Choose items to record: all or custom.
 ALL DATA RECORD
“01” ENTER
: Record all sensor data
USER SELECT DATA RECORD.
: Record user defined sensor data.
 FIX : Select sensors to record in ‘USER
SELECT DATA RECORD”.
 ENTER : Start “RECORDING”
“02” ENTER
 ESC :”STOP” recording
Hi-Scan Pro Application
1.6 FLIGHT RECORD – AUTO TRIGGER (SINGLE DTC)
Enter specific DTC which will be used as trigger.
 AUTO TRIGGER(SINGLE DTC)
: Record user defined single DTC.
 Type specific “DTC CODE”
and press “ENTER”.
 Rest of procedures are same as
“AUTO TRIGGER (ANY DTC)”
ENTER
Type DTC CODE
and press ENTER
Hi-Scan Pro Application
1.6 FLIGHT RECORD – MANUAL TRIGGER (1/2)
User triggers the record data.
 MANUAL TRIGGER
: Place a mark on a recorded data where
“ENTER” button is pressed while recording.
This mark is displayed as vertical line in “GRAPH” mode.
 Next procedures are same as “AUTO TRIGGER”.
 Select “DATA RECORD” type.
Same procedure as
“AUTO TRIGGER”
Hi-Scan Pro Application
1.6 FLIGHT RECORD– MANUAL TRIGGER (2/2)
Choose items to record: all or custom.
 ALL DATA RECORD
: Record all sensor data
 ENTER : Place a mark on a data where
“01” ENTER
“ ENTER” is pressed while
recording.
USER SELECT DATA RECORD.
: Record user defined sensor data.
 FIX : Select sensors to record and press
“F1”.
 ENTER : Start “RECORDING”.
“02” ENTER
 ENTER : Start “TRIGGERING”.
 ESC :”STOP” recording.
Hi-Scan Pro Application
1.6 FLIGHT RECORD –FLIGHT RECORD VIEW (1/2)
Review recorded data.
 FLIGHT RECORD DATA REVIEW
: Review recorded data.
 Select the memory location,
then press “ENTER”.
 Press “ENTER” to review recorded data.
ENTER
Select the memory location
and press “ENTER”
Hi-Scan Pro Application
1.6 FLIGHT RECORD –FLIGHT RECORD VIEW (2/2)
Select review type.
 GRAP : Covert the “LIST” screen into
“GRAPH”.
 LIST : Covert the “GRAPH” screen into
“LIST”.
 HOME : Place the triggered position,
displayed as vertical line,
middle of the screen.
at the
 FIX : You can scroll up and down without
moving fixed item.
If you press “FIX” again, you can
change the item to fix.
ENTER
F1 “GRAP”
F1 “LIST”
Hi-Scan Pro Application
1.7 DUAL DISPLAY
Inspect the sensor or actuator data and DTC
Previous menu
ENTER
ENTER
ENTER
ENTER
ENTER
Select “DUAL DISPLAY” in “KIA
VEHICLE DIAGNOSIS” mode.
In this case, connect with vehicle via
DLC cable.

F1 FIX
F2 CURR
F3 DTC




Hi-Scan Pro can display both
DTC and sensor data
simultaneously.
Use can check the sensor data
which with DTC.
FIX
: Fix sensor data
CURR : Activate current data
DTC : Activate DTC data
Hi-Scan Pro Application
1.8 SIMU-SCAN (1/4)
Simulate and scan sensor or actuator simultaneously
Previous menu
ENTER
ENTER
ENTER
ENTER
Select “SIMU-SCAM” in “KIA
VEHICLE DIAGNOSIS” mode.
ENTER
In this case, connect with vehicle via
DLC cable and test probe.
F1 METER
F2 SIML

METER : voltage, frequency, duty,
current, temperature and pressure
meter

SIMUL : voltage, frequency, duty,
simulation
Hi-Scan Pro Application
1.8 SIMU-SCAN (2/4)
To measure the sensor data and compare with scan data
F1 METER

METER MODE
: One of the most powerful feature of
Hi-Scan Pro is SIMU-SCAN, in
which sensor output data is measured
and current data is displayed
simultaneously that user can compare
actual data and ECM data.
PRESS “1” BUTTON ON KEY PAD

: This figure is an example of SIMUSCAN screen for ECT sensor.
Hi-Scan Pro Application
1.8 SIMU-SCAN (3/4)
To measure the sensor data and compare with scan data
F1 METER
PRESS “2” BUTTON
ON KEY PAD
PRESS “5” BUTTON
ON KEY PAD

METER MODE
: This is an example of
SIMU-SCAN screen for
ISC on time.
Hi-Scan Pro Application
1.8 SIMU-SCAN (4/4)
To measure the sensor data and compare with scan data
F2 SIML
 SIMU MODE
:This is an example of SIMUSELECT NUMBER “1”
OF KEY PAD
SCAN screen for TPS sensor
with generated voltage 2V.
 NOTICE
: SIMU MODE activate on
channel B only.
Hi-Scan Pro Application
2. VEHICLE SCOPEMETER
2.1 Part analysis
- Engine : 17 items
- Auto T/A : 9 items
2.2 Manual scope
2.3 Meter(V,F,R,A,T,P)
2.4 Actuator driving
2.5 Sensor simulator
Hi-Scan Pro Application
2.1 PART ANALYSIS (1/2)
Analyze part precisely in pre-set oscilloscope mode
Select “VEHICLE
SCOPEMETER” in “INITIAL
SCREEN” and select “KIA
VEHICLE AUTO SCOPE”.

Connect a test probe to “CH A”
of Hi-Scan Pro and tap probe pin
into appropriate signal wire of
sensor or actuator.

ENTER




Provides easier component
inspection and more effective with
pre-set DB support and reference
waveform.
KIA VEHICLE AUTO SCOPE
: Pre-set oscilloscope for KIA
vehicles.
MANUAL SCOPE : Oscilloscope
mode.
METER : Multi-meter mode.
ACTUATOR DRIVING
: Test drive “ACTUATOR”.
SENSOR SIMULATOR
: Send dummy data to inspect
status of sensors.
Hi-Scan Pro Application
2.1 PART ANALYSIS (2/2)
Analyze part precisely in pre-set oscilloscope mode
ENTER
ENTER
ENTER

ENGINE : 17 items.

A/T : 9 items
Hi-Scan Pro Application
2.1 PART ANALYSIS ---- ENGINE : SENSOR (1/2)
Analyze part precisely in pre-set oscilloscope mode
PREVIOUS MENU
ENTER
ENTER
ENTER
ENTER


Engine sensor mode has
17 pre-set items.
User have to connect test
probe to “CH A”, and
prick probe pin to sensor
signal wire.
Hi-Scan Pro Application
2.1 PART ANALYSIS ---- ENGINE : SENSOR (2/2)
Analyze part precisely in pre-set oscilloscope mode
PREVIOUS MENU
ENTER
ENTER
ENTER
ENTER
ENTER
WAVE
 CKP SENSOR



TIP
TIPS : Sensor information.
WAVE : Reference waveform
of sensor.
AUTO SET DB SUPPORT
- Voltage, Time, Trigger Level.
Hi-Scan Pro Application
2.1 PART ANALYSIS ---- ENGINE : ACTUATORS
Analyze part precisely in pre-set oscilloscope mode
PREVIOUS MENU
ENTER
ENTER
ENTER
ENTER
WAVE
ENTER
 INJECTOR

TIPS
: Actuator Information.

WAVE : Reference Waveform
of sensor.

AUTO SET DB SUPPORT –
Voltage, Time, Trigger Level.
TIP
Hi-Scan Pro Application
2.1 PART ANALYSIS ---- ENGINE : IGNITION
Analyze part precisely in pre-set oscilloscope mode
PREVIOUS MENU
ENTER
ENTER
ENTER
ENTER
ENTER


WAVE

1’ST IGNATION WAVE
WAVE : Standard waveform
of sensor
AUTO SET DB SUPPORT Voltage, Time, Trigger Level.
Hi-Scan Pro Application
2.1 PART ANALYSIS ---- Automatic Transmission
Analyze part precisely in pre-set oscilloscope mode
ENTER
ENTER

Automatic Transaxle
mode has 9 pre-set items.
Hi-Scan Pro Application
2.2 MANUAL SCOPE
User defined oscilloscope.
Select “VEHICLE SCOPEMETER” in “INITIAL
SCREEN” and select “VEHICLE SCOPEMETER”.
Connect a test probe to “CH A” or “CH B” of HiScan Pro and tap into signal wire of sensor or
actuator.
ENTER
Hi-Scan Pro Application
2.2 MANUAL SCOPE (1/3)
User defined oscilloscope.
PREVIOUS MENU
ENTER
ENTER

2 Channel digital scope

Sampling speed : 1MHz / Sec

Time division

Voltage division : 0.5V ~ 50V

Adjustable GND level

Waveform zoom function
(1x, 2x, 5x)

Cursor data display
: 20㎲ ~ 50S
Hi-Scan Pro Application
2.2 MANUAL SCOPE (2/3)
User defined oscilloscope.
PREVIOUS MENU
ENTER
ENTER
Selectable data “ON / OFF” by ◁,▷ KEY

Selectable grid line /dot by ◁,▷KEY

Selectable trigger mode by ◁,▷KEY
- MODE : “Repeat”, “Single”, “Auto”
- SOURCE : A↑A↓B↑B↓
- LEVEL : 0 ~ 100%
- DELAY : 0 ~ 100%

Hi-Scan Pro Application
2.2 MANUAL SCOPE (3/3)
User defined oscilloscope.
PREVIOUS MENU
ENTER





Larger record space - 128KB continuous sampling
Video replay view
Trend view function
(AVERAGE, MIN-MAX,FREQUENCY, DUTY)
Cursor data display
Waveform zoom function
(1x, 2x, 5x)
Hi-Scan Pro Application
PREVIOUS MENU
2.2 MANUAL SCOPE – HOLD (1/7)
How to use “HOLD” function.
ENTER
HOLD




ZOOM
CURS
HOLD : Screen hold.
Function key will be changed
after “HOLD” button is pressed.
ZOOM : Zoom “IN” or “OUT”
screen. - X1, X2, X5.
CURSOR : Display numerical
value of waveform.
RECORD : Record waveform.
RECD
Hi-Scan Pro Application
2.2 MANUAL SCOPE – HOLD (2/7) : ZOOM
How to use “ZOOM” function.
PREVIOUS MENU
ENTER
ENTER
ZOOM

ZOOM

User can zoom “IN” or “OUT” by pressing
“▲” or “▼” button respectively.
User can scroll “LEFT” to “RIGHT” by
pressing “◀” or “▶” button respectively.

Hi-Scan Pro Application
2.2 MANUAL SCOPE – HOLD (3/7) : CURSOR
How to use “CURSUR” function.
PREVIOUS MENU
ENTER
ENTER

CURS





CURSOR
Cursor is used to display numerical value of waveform.
Press “CURS” to display two “CURSORS”.
Move left cursor-straight lined- by pressing “◀” or “
▶” button.
Press “CURS” button again to activate Right cursordashed line.
Cursor will be converted from “dash” to “straight”.
Press “CURS” button once again, to move both cursors
together.
All the values will be displayed at the top of the screen.
Hi-Scan Pro Application
2.2 MANUAL SCOPE – HOLD (4/7) : RECORD
How to use record function.
PREVIOUS MENU
ENTER
ENTER
RECD



RECORD : Records for 1 second
FLIGHT RECORD REVIEW
: Review previously recorded data.
NEW FLIGHT RECORD
: Record new data-New data; overwrite on
previous record.
Hi-Scan Pro Application
2.2 MANUAL SCOPE – HOLD (5/7) : FLIGHT RECORD VIEW(1/2)
How to view “FLIGHT RECORD”.
PREVIOUS MENU
ENTER





ENTER

HOLD : Screen hold.
PLAY : Play recorded data.
ZOOM : Zoom IN or OUT screen.
CURS : Display numerical value of waveform.
VIEW : AVERAGE & MIN-MAX TREND
FREQUENCY & DUTY TREND
FLIGHT RECORDED WAVEFORM
EXIT : Return to “HOLD” mode.
HOLD
Hi-Scan Pro Application
2.2 MANUAL SCOPE – HOLD (6/7) : FLIGHT RECORD VIEW(2/2)
How to view “FLIGHT RECORD”.
VIEW




AVERAGE & MIN-MAX
TREND
AVERAGE & MIN-MAN TREND
: Display average, minimum, and maximum
value of waveform.
FREQUENCY & DUTY TREND
: Display frequency and duty of waveform.
FLIGHT RECORDED WAVEFORM
: Return to “HOLD” mode.
Scroll left or right by “◀” or “▶” respectively and the
cursor data is displayed in the box at the left.
FREQUENCY & DUTY
TREND
FLIGHT RECORDED
WAVEFORM
Hi-Scan Pro Application
2.2 MANUAL SCOPE – HOLD (7/7) : NEW FLIGHT RECORD
How to record a “FLIGHT RECORD”.


RECD

HIT ANY KEY
NEW FLIGHT RECORD
: Overwrite new data on previous data.
Press any button to start recording.
Replay start after recording is finished.
Hi-Scan Pro Application
2.2 MANUAL SCOPE – MENU : DATA
What is “DATA” function.
PREVIOUS MENU
ENTER
ON


OFF


DATA
ON : Following data will be displayed at the top of the screen.
1) MIN : Minimum Voltage.
2) AVE : Average Voltage.
3) MAX : Maximum Voltage.
4) FREQ : Frequency of Waveform.
5) DUTY : Duty cycle of Waveform.
OFF : “DATA” will disappear.
NOTE : If the “TIME” is set as “20us”, “DATA” function will
not be supported and only one channel is available-“Ch A” or
“Ch B” due to fast sampling load.
Hi-Scan Pro Application
2.2 MANUAL SCOPE – MENU : GRID
What is “GRID”.
PREVIOUS MENU
ENTER


GRID
User can change the “GRID” from “DOT” or “LINE” to
“LINE” or “DOT” respectively.
DOT
LINE
Hi-Scan Pro Application
2.2 MANUAL SCOPE – MENU : TRIGGER (1/2)
What is “TRIGGER” type.
PREVIOUS MENU
ENTER




MODE
AUTO : Display all the waveform regardless of trigger level.
REPEAT : Screen is refreshed whenever waveform is above the
trigger level.
SINGLE : If waveform is above the trigger level, the screen
will be fixed with triggered waveform.
Hi-Scan Pro Application
2.2 MANUAL SCOPE – MENU : TRIGGER (2/2)
How to set and use “TRIGGER”.
PREVIOUS MENU
ENTER
SOURCE

A↑, B↑
: “Rising edge” of waveform will be displayed at the
delay level.

A↓, B↓
: “Falling edge” of waveform will be displayed at the
delay level.

LEVEL : Waveform will be displayed if it is above
this “Trigger level”.

DELAY : Horizontal position of “Triggered place”.

Hi-Scan Pro Application
2.3 MULTI METER
What is “MULTIMETER”.
Connect a test probe from “CH A”
or “CH B”, or both channel and
to desired Actuator or Sensor.
Enter after select “3. Meter”
PREVIOUS MENU
ENTER






2 channel multi meter
Volt meter : max 500VDC
Frequency meter : 0 ~ 100KHz
Duty meter : 0 ~ 100%
Ohm meter : 0 ~ 10㏁
Automatic unit conversion (CURRENT METER /
TEMPERATUE / PRESSUR METER)
Hi-Scan Pro Application
2.4 ACTUATOR DRIVING
How to drive an actuator.
Enter after select “4. Actuator”
PREVIOUS MENU
ENTER
Connect a test probe from “CH
A” and to desired Actuator.


Actuator Driving Mode enables to operate
actuator forcibly driven by Hi-Scan pro
Actuator driving is operated only on “CH A”.

Warning) Do not use this mode when Engine Is
running

DRIV => Start Driving

STOP => Stop Driving

◁ ▷ => Select the Items

△▽ => Chang the Selected Items Level
Hi-Scan Pro Application
2.5 SENSOR SIMULATOR
How to simulate a sensor.
Enter after select “5. Sensor simulator”
PREVIOUS MENU
ENTER
Connect a test probe to “CH B”
and to desired Sensor.




Sensor simulation is operated only on “CH B”
User can simulate a sensor in this mode.
VOLT-Simulate a sensor with specific “VOLTAGE”
FREQ-Simulate a sensor with specific “FREQUENCY”
In “FREQ” mode, user can switch from the ‘Frequency’
to ‘Duty’ and vice versa by pressing “SLCT” button.
In “FREQ” mode, user can change the value of
‘Frequency’ and ‘Duty’ using “+” and “-” button.
Hi-Scan Pro Application
3. SYSTEM SETUP
Setup system.
ENTER
ENTER





Hold Last Screen => Determines whether the last screen
in vehicle diagnosis or oscilloscope mode is saved before
power shut down
Language =>Determine whether to use “Beep” sound
when the buttons are pressed.
Language => Determines whether local language is used
Unit Conversion => Selects the measuring units of HiScan pro.
Self Test => Determines whether self test is performed at
each power up
Hi-Scan Pro Application
4. OPTIONAL ITEMS
4.1 Current pick up(1A ~ 600A)
4.2 Current pick up(50mA ~ 100A)
CURRENT PICK UP (1~600A)

Compression pressure test

Cold cranking ampere test

Etc
CURRENT PICK UP (1~600A)(1/2)
PREVIOUS MENU
To perform compression pressure test.




ENTER
Connect high current measuring device to CH A or B
Set to “10mV/A” in current level selecting switch.
Perform zero adjustment.
Set as 50ms for time-division and 5V for voltagedivision.
CURRENT PICK UP (1~600A)(2/2)
To perform compression pressure test.




When 1st cylinder spark plug is removed
Clamp the “+” or “-” terminal of battery
with current measuring device.
Remove ECU fuse.
Start cranking for about 2 seconds.
Abnormal and normal waveforms are
shown respectively at the bottom.
CURRENT PICK UP (1~600A)(1/2)
To perform cold cranking ampere test.




PREVIOUS MENU
ENTER
Connect high current measuring device to CH A or B
Set to “1mV/A” in current level selecting switch.
Perform zero adjustment.
Set as 50ms for time-division and 0.2V for voltagedivision.
CURRENT PICK UP (1~600A)(2/2)
To perform cold cranking ampere test.






Clamp the “+” or “-” terminal of battery with
current measuring device.
Remove ECU fuse.
Start cranking for about 2 seconds.
Example waveform is shown at the bottom right.
When testing cranking current, read MAX value
for current value as shown in bottom right fig.
Example) Regard MAX : 335,2mV as 335,2A
for cranking current.
Compare with standard value, if it is above 70%
then it is in normal condition.
CURRENT PICK UP (50mA~100A)

Primary ignition current test

Actuators current test

Etc
CURRENT PICK UP (50mA~100A)(1/2)
To perform primary ignition current test.




PREVIOUS MENU
ENTER
Connect low current measuring device to CH A or B
Set to proper level in current level selecting switch.
Perform zero adjustment.
Set time-division and voltage-division.
CURRENT PICK UP (50mA~100A)(2/2)
To perform primary ignition current test.

Clamp the primary ignition signal wire
with low current measuring device.
CURRENT PICK UP (50mA~100A)
PREVIOUS MENU
ENTER
To perform actuators current test.





Connect low current measuring device to CH A or B
Set to proper level in current level selecting switch.
Perform zero adjustment.
Set time-division and voltage-division in Hi-Scan pro.
Clamp any actuator you wish to measure with low
current measuring device.
CURRENT PICK UP (50mA~100A)(1/2)
To measure parasitic current.
PREVIOUS MENU
ENTER



Connect low current measuring device to CH A or B
In ‘METER’ screen, select channel and current level
and press ‘Enter’.
Select current level as assigned in Hi-Scan Pro.
CURRENT PICK UP (50mA~100A)(2/2)
To measure parasitic current.


Perform zero adjustment.
The parasitic current of wire, which is connected
from battery to 60A fuse in fuse box, is measured in
Hyundai Accent as shown at the bottom right figure.
5. PC-SCAN
1) Install PC-Scan
2) SCAN TEST
3) FLIGHT RECORD
4) SCOPE
5) SERVICE INFORMATION
6) SCREEN CAPTURE
7) S/W DOWNLOAD
8) OPTION
1) Installation of PC-SCAN program - 1
 Insert the CD and click “Setup” file, and then follow instruction as
shown in figure 1~5 step by step.
CLICK THE “OK” BUTTON
DOUBLE CLICK THE SETUP
ICON
Installation of PC-SCAN program - 2
CLICK INSTALL BUTTON
CHOOSE INSTALL DIRECTORY
PROGRAM INSTALLING
PROGRAM INSTALL DONE
2) SCAN TEST - 1


This function is to provide all of the
scanning tests on your PC. If you press
'SCAN TEST' button on the menu, the
following "Vehicle Diagnosis" screen will
be displayed for your vehicle/system
selection to test firstly.
Select the vehicle/system to test in order as
follows.
(1) Select proper vehicle model to test on
the upper-left column.
(2) Select proper system name to test on
the upper-right column
(3) Select proper system type on the
lower-left column.
SCAN TEST- 2
(DIAGNOSTICS TROUBLE CODES)






If you press [DIAGNOSTIC TROUBLE
CODES] button on the picture’s Sub Menu
screen, the following screen will be displayed
for DTC testing.
ERASE : Provides to erase the memorized
DTC after repairing the
troubles clearly.
TIP
: Provides relevant service or
repair guides
PRINT
: Provides to print current
screen out.
HELP
: Provides relevant user's
operation guides on the
current screen.
PREVIOUS : Provides to return to the
previous menu screen
SCAN TEST - 3
(CURRENT DATA)







This function is to provide on-line current data analysis
of each sensor transferred through the ECU.
If you press [CURRENT DATA] button on the picture’s
Sub Menu, the following screen will be displayed for
Current Data Analysis.
Select sensor names(maximum 8 items at once) on the
sensor item column by clicking the items. To cancel its
selection, click it again of the selected item.
TEXT : Provides on-line numeric values on the selected
sensors as picture.
PRINT : Provides to print current screen out.
TIPS : Provides diagnostic information for service data
which selected finally.
PREVIOUS : Provides to return to the previous menu
screen.
GRAPH : Provides to analyze on-line current data
values in a graphic waveform as below.
SCAN TEST - 4
(CURRENT DATA)









RECORD : Provides to record current graphic data in a
temporary buffer memory on PC.
MARKING : Provides to indicate location mark during
data recording.
STOP : Provides to stop recording
REC DATA VIEW : Provides to recall a waveform data
from the recorded temporary memory on PC.
SAVE : Provides to save any waveform data in a file form
from the temporary memory data.
PRINT : Provides to print out current screen.
HELP : Provides relevant user's operation guides on the
current screen.
PREVIOUS : Provides to return to the previous Current
Data Main menu screen.
ZOOM BAR : Provides to magnify current screen by using
the arrow buttons up to 10 times.
SCAN TEST- 5
(ACTUATION TEST)

This function mode enables to operate certain actuators
through communication between ECM and Hi-Scan Pro.
So, If the ECM does not provide this function, you can not
use this actuation test mode.

Select any actuator item to test on the left column and click it on.
The test must be performed as per the conditions indicated on
the screen. To cancel the selection, click it on again.

START : Provides to start its testing.
PRINT : Provides to print current screen out.
HELP : Provides relevant user's operation guides on the
current screen.
PREVIOUS : Provides to return to the previous function
menu screen.



3) FLIGHT RECORD

This function is to provide downloading a data to your PC from
the recorded memory of the Hi-Scan Pro, or recalling a data from
the
PC
memory.

LIBRARY : Provides to recall and refer pre-memorized
standard sample data or waveform.
OPEN : Provides to open a recorded flight data file from PC
memory.
SAVE : Provides to save a flight record data in a file form.
LOAD : Provides to download a flight record data from HiScan Pro into your PC.
INFORMATION : Provides to add user's information on the
current data screen.
PRINT : Provides to print current screen out.
HELP : Provides relevant user's operation guides on the
current screen.
PREVIOUS : Provides to return to the main menu screen.







4) SCOPE

This function is to provide downloading a scope data either
from your PC or Hi-Scan Pro memory.

LIBRARY : Provides to recall pre-memorized standard
sample scope waveforms.
OPEN : Provides to open a recorded scope waveform file
from your PC memory.
SAVE : Provides to save a scope waveform in a file form
to your PC.
LOAD : Provides to download a scope waveform from
Hi-Scan Pro into your PC.
INFORMATION : Provides to add user's information on
the current data screen.
NOTE : Provides to add a personal information label on
the current data screen for detailed explanation.
PRINT : Provides to print out current screen.
HELP : Provides relevant user's operation guides on
the current screen.
PREVIOUS : Provides to return to the main menu
screen.








5) SERVICE INFORMATION

This mode provides all of the relevant service and repair
information for each vehicle and system in CD-ROM.

BACK : Provides to return to the previous screen.
FORWARD : Provides to go to the next screen.
E-MAIL : Provides to send an E-Mail message to the
supplier.
PRINT : Provides to print out the current screen.
MAIN : Provides to return to the main menu screen.





Exploring methods and procedures are same as those of
general Internet Web-browser.
* Note : Be sure to insert relevant CD-ROM into your
PC driver before using this mode.
6) SCREEN CAPTUTE














This function is to provide either downloading or saving current
screen onto your PC.
LIBRARY : Recall pre-memorized standard sample data.
OPEN : Open a saved screen capture data file from your PC hard
disk.
SAVE : Save the captured screen in a file form.
LOAD : Download current Hi-scan Pro screen onto your PC.
INFORMATION : Add user's information on the current data.
NOTE : Add notes about current data screen for personal record.
PRINT : Print out current screen.
HELP
: Provides relevant user's operation guides on the
current screen.
PREVIOUS : Return to main menu screen.
TITLE : Input title of captured screen.
MADE BY : Input user's name on the captured screen.
FILENAME : Not accessible by users. It's for program designer's
purpose.
* Use [SAVE] button to input its file name.
COMMENT : Add personal comments.
7) S/W DOWNLOAD - 1
 Get connected
: Connect your PC and Hi-Scan Pro with RS-232C cable
COM1
RS232C Cable
(Standard Item)
S/W DOWNLOAD - 2
 After connect RS-232C cable, go to “OPTION” in Pc-scan main
screen and assign com port 1 or 2.
SELECT COMMPORT 1 OR 2
CLICK “ OPTION” BUTTON
CLICK “OK” BUTTON
Please move “cardall.dat” file into “PcScan.CAB”
S/W DOWNLOAD - 3


Select S/W Download in your PC-Scan Program initial screen as
shown in below figures.
Select “cardall.dat” file at DB folder which is in PcScan.CAB file.
SELECT CARDALL.DAT
 NOTICE
* Assign the file(cardall.dat) path
* Select 56000 for Baud Rate
* Select “Standard Pack” for Data Type
8) OPTION






This function is to set-up communication speed and CD-ROM directory for Service
Information function.
BAUD RATE : Select communication speed between your PC and Hi-Scan Pro from
9,600 up to 56,000 bps.
SERVICE INFORMATION FOLDER (Main.html) : Select the location of
Main.html file.
HELP : Provides relevant user's operation guides on the current screen.
OK : Confirm selection.
CANCEL : Cancel selection and return to the main menu screen.
Download