PowerLogic EGX300 Training Integrated gateway-server for entry-level system monitoring EGX300 Overview View device data through a simple browser – no software needed EGX300 web page Trend plots Data log files EGX100 EGX300 Pull information into web pages from other PowerLogic gateways (PM8ECC, EGX100) ION 6200 Schneider Electric - Division - Name – Date PM800 Micrologic Sepam 2 Outline Training ● Minimum System Requirements ● Physical Characteristic ● Ethernet ● Serial ● Exterior ● TRe ● Setup ●AutoDiscovery ●Data Export ● Monitor ●Single Device Page ●Summary Pages ●Logging ●Custom Pages ● Documentation ● Control ●Resets ● Diagnostic ● Maintenance Schneider Electric - Division - Name – Date ● Advance Feature ● Remote Device connection ● Custom Logo ● Supported Devices ● Application Architecture ● Obsolescence Plan ● Legacy Solutions ● Language File Customization ● Accessory Kits ● FAQ ● Appendix ● Changes in red denotes Phase 2 functions 3 Minimum System Requirements Although there is NO need to install any software, the computer accessing EGX300 will need to have a browser installed. We support: ● Microsoft Internet Explorer 6.0 or higher Schneider Electric - Division - Name – Date 4 Physical Characteristic: Ethernet ● Ethernet ● 10/100BaseTx ● Media Type: ●10T/100Tx Auto ●10BaseT-HD ●10BaseT-FD ●100BaseTx-HD ●100BaseTx-FD ● Framing: Ethernet II & 802.3 (SNAP) ● IP Parameters: Address, Subnet Mask, & Default Gateway ● Protocols: HTTP, ModbusTCP/IP, FTP, SNMP (MIB II), SNTP, SMTP ● Connector: RJ45 ● Pinout: Industry standard ● Supports 48 concurrent ModbusTCP/IP connections ● Duplicate IP address detection (FDR basic) Schneider Electric - Division - Name – Date 5 Physical Characteristic: Serial ● Serial Line ● ● ● ● ● ● ● All lines optically isolated Physical interface: RS485 4-wire, RS485 2-wire, RS232 Protocols: ModbusRTU, POWERLOGIC (SY/MAX), ModbusASCII, Jbus Baud: 2400–38400bps (RS485); 2400-57600bps (RS232 ASCII) Parity: None, Even, & Odd Response timeout: 0.1 to 10 seconds (default = 3 seconds) Connector: ●RS485 5 position plugable screw-terminal ●RS232 RJ45 ● Pinout: ●RS232 Industry standard EIA561 for RJ45 ● Note: EGX300 is internally connected: no need to physically connect the EGX300 for two wire mode. Schneider Electric - Division - Name – Date 6 Physical Characteristic: Exterior Control power (screw terminal connector) RJ45 Ethernet port (IEEE802.3af) LED indicator for power & status Recessed reset button LED indicators for Ethernet and serial communications Schneider Electric - Division - Name – Date 7 Physical Characteristic: Exterior RS485 serial port (screw terminal connector) Bias, Termination, and 2-wire / 4-wire jumper switches Schneider Electric - Division - Name – Date RS232 serial port (RJ45 connector) 8 Transparent Ready {TRe} ● Embedded web server provides real-time tabular data views for all supported device types ●Single Device Basic Readings - Includes Analog Meters view with -Three-phase Current - Real, Reactive, and Apparent Power - Line-line phase Voltage - Line-neutral phase Voltage ●Summary Device Views – Circuit Summary – Load Current Summary – Demand Current Summary – Power Summary – Energy Summary ●Real-time Trending Graph view (multi-device, multi-topic) – Includes a running table of min/max/avg values – Includes a tabular view of trended data ● Advanced users can create custom web views Schneider Electric - Division - Name – Date 9 TRe: Setup ● Ethernet & TCP/IP ● Serial Port ● Remote Device Connections ● Device List ● Device Logging ● Device Log Export ● Date and Time ● SNMP Parameters ● Modbus TCP/IP Filtering ● Documentation Links ● User Accounts ● Web Page Access ● Preferences Schneider Electric - Division - Name – Date 10 TRe: Setup => Auto Discovery ● EGX300 features the ability to “Auto Discover” devices in its daisy chain ● The EGX300 will not find remote devices; the user will need to define a locate address and remote address ● Look under the device list and scroll to the bottom of the page ● The user needs to setup the right baud rate and settings for this ability to work. Press to Discover Schneider Electric - Division - Name – Date 11 Note: Device List ● Devices can either be manually entered or auto discovered. ● You can manually enter a device and not have it present; however, you will not have a page created for the device until the device is connected. ● There should not be a problem for communication because the EGX300 will not detect the device. Schneider Electric - Division - Name – Date 12 TRe: Setup => Data Export ● Users have four options ● Disable ● Export via FTP ● Export via HTTP ● Export via E-mail ● Users will have to setup logging first before choosing either options ● Uses can now only send “incremental” data versus ALL data with the EGX400 ● Data can be push incrementally ● For Equipment Plants, the option is usually disable by default. Schneider Electric - Division - Name – Date 13 TRe: Monitor => Single Device Page ● The EGX300 has the ability to display real time readings from devices. ● The devices can be selected individually ● All data displayed has been scaled and set at factory ● Any unique requests will have to be done as a custom page ● Analog Meter Display is Available Schneider Electric - Division - Name – Date 14 TRe: Monitor => Summary Pages Summary Pages are standard with TRe level 2 support. Users can select ALL or individual pages to be displayed the summary pages. Pages to be displayed: ● Circuit Summary ● Load Current ● Demand Current ● Power ● Energy Schneider Electric - Division - Name – Date 15 TRe: Monitoring => Logging ● Embedded web server provides user selectable topics per device ● Provides logging function to store data from serial devices on 5, 10,15, 20, 30, or 60 minute intervals ● Embedded web server provides a graphical view of stored data logs ● Provides Simple Mail Transfer Protocol (SMTP) to E-mail stored device data logs on user defined intervals ● Provides File Transfer Protocol (FTP) server to access device data logs ● Provides the ability to send data logs manually with the click of a button Schneider Electric - Division - Name – Date 16 Logging File: example.csv Schneider Electric - Division - Name – Date 17 TRe: Monitoring => Real Time Trending ● Real Time Trending with devices through web interface ● Can choose multiple topics Schneider Electric - Division - Name – Date 18 Monitor: Trend Plots through log files Schneider Electric - Division - Name – Date 19 TRe: Monitoring => Custom Pages ● EGX300 will allow users to transfer their own custom pages ● Custom pages will allow users to have the flexibility to create their own custom solution Schneider Electric - Division - Name – Date 20 TRe: Documentation ● As part of TRe, users can transfer documentation or create documentation links ● Users can store up to 512 Mb ● The documentation can link to other devices that have web server capabilities Schneider Electric - Division - Name – Date 21 Control ● On the Control page, users can reset the values of their individual devices. Schneider Electric - Division - Name – Date 22 Diagnostic ● Users can: ● Look at stats for the EGX300 ● Read devices on this page ● Check Communication Connection ● The stats information will be used by design and tech support to analyze the system situation Schneider Electric - Division - Name – Date 23 Diagnostic: Accumulative Connections ● Users can click accumulative connections and displayed previous connections ● This is valuable in terms of security to keep track of users who have logged on before. Schneider Electric - Division - Name – Date 24 Maintenance Log ● EGX300 provides the ability to record maintenance log files. ● Typical users can record simple text information about system or challenges. Schneider Electric - Division - Name – Date 25 Advance Features: Remote Connection ● Under Remote Device Connection, users can setup logging remotely and access devices remotely Schneider Electric - Division - Name – Date 26 Custom Logo Logo ● Users can customize splash screen, logo, color, and favicon ● Please refer to the white paper for detail specifications ● This will allow Integrators to add more value for their services Favicon Splash Screen Schneider Electric - Division - Name – Date 27 Viewable Device Type ● Ability to hide un needed device type from the device list Schneider Electric - Division - Name – Date 28 Device Types for Support => Refer to next slides for level of support ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● BCM BCPM A/B/C CM100/200 CM2000 Series Meters CM3000 Series Meters CM4000 Series Meters DM6200 E5600 Enercept Energy Meter ION6200 ION7300 ION7650 MCM Micrologic A Micrologic H Micrologic P MicrologicA+CCM MicrologicH+CCM MicrologicP+CCM Model98 Schneider Electric - Division - Name – Date ● ● ● ● ● ● ● ● ● ● ● ● Motorlogic Plus Motorlogic Plus II MVSS/RVSS PM210 PM600 Series Meters PM700 Series Meters PM800 Series Meters PM1200 Sepam 2000 Sepam Series 10 Sepam Series 20 Sepam Series 40 ● Sepam Series 80 29 Level of Support through EGX300 TRe Compatibility View Data ION E Compatibility Transfer Datalog Waveform Captures Device Based Alarms SMS Compatibility Transfer Datalog Waveform Captures Device Based Alarms CM100/200 x x x CM2000 Series x x x CM3000 Series x x x CM4000 Series x x x Enercept Meters x x x Energy Meters x x x PM210 x x x PM600 Series x x x PM700 Series x x x PM800 Series x x x Schneider Electric - Division - Name – Date 30 Level of Support through EGX300 TRe Compatibility View Data ION E Compatibility Transfer Datalog Waveform Captures Device Based Alarms SMS Compatibility Transfer Datalog Waveform Captures Device Based Alarms ION 6200* x ION 7300* x ION 7650* x SEPAM 2000 x x x SEPAM Series 20 x x x SEPAM Series 40 x x x SEPAM Series 80 x x x x *ION E can not be supported through the EGX300 with full capabilities due to no support of ION protocol Schneider Electric - Division - Name – Date 31 Level of Support through EGX300 TRe Compatibility View Data ION E Compatibility Transfer Datalog Waveform Captures Device Based Alarms SMS Compatibility Transfer Datalog Waveform Captures Device Based Alarms Model 98 x x x Micrologic Plus x x x Micrologic Plus II x x x MVSS/RVSS x x x Micrologic A x x x Micrologic H x x x Micrologic P x x x Micrologic A+CCM x x x Micrologic H+CCM x x x Micrologic P+CCM x x x Schneider Electric - Division - Name – Date 32 Application Architecture ● How to address the following situations: ● Two and Four Wire Systems ● Remote Access to Other Gateways Schneider Electric - Division - Name – Date 33 Two and Four Wire Systems Ethernet Network RS-485 (4 Wire) RS-485 (2 Wire) N < 32 Up to 64 Devices can be view by one EGX300 EGX300 can remotely connect to other gateways Schneider Electric - Division - Name – Date 34 Remote Access to Other Gateways Ethernet EGX300 EGX100 EGX300 can poll EGX100 through Ethernet Schneider Electric - Division - Name – Date 35 Obsolescence Plan ● EGX300 will be introduced by Q1 2009 ● We will stop selling EGX400 by Q1 2010 ● We will have stock to replace existing EGX400 for warranty/repair purposes for about three years Schneider Electric - Division - Name – Date ● Special Substitution Use Cases (refer to following slides after): ● Second Serial Port ● Older Systems 36 Second Serial Port Ethernet EGX100 EGX300 N <= 32 N <= 32 Up to 64 Devices can be viewed by one EGX300 EGX300 can remotely connect to other gateways Schneider Electric - Division - Name – Date 37 Legacy Systems Ethernet EGX300 CNV100 2 wire System 4 wire System Schneider Electric - Division - Name – Date 38 Accessory Kit ● Allows configuration via RS232 serial or Ethernet port ● Kit Contents ● RJ45 to DB9F adapter ● CAT5 Crossover cable, 3-meters (10-feet), orange ● Instruction sheet ● Ordering Information ● TCSEAK0100 ● Market Price (average) ● $50 (USD) Schneider Electric - Division - Name – Date 39 Configuration Kit Schneider Electric - Division - Name – Date IF USB ONLY, need converter to serial 40 Accessories - PoE Injector (IEEE 802.3af) ● Active mid-span device with universal power cord ● Contents ● Universal power cord (IEC-60320-C13 & IEC60320-C14, 3-meters (10-feet) ● Plug adapters for Australia, Europe, UK, USA ● Instruction sheet ● Ordering Information ● TCSEAV0100 ● Market Price (average) ● $80 (USD) Schneider Electric - Division - Name – Date 41 PoE Injector Kit Schneider Electric - Division - Name – Date 42 FAQ ● Are we limited to the predefine topics already in the logging section setup? ● No, we can add more topics; however, we are limited to logging 12 topics ● How many languages can the EGX300 support? ● We can support up to 8 languages with 4 default (English, French, Spanish, German) ● What type of file formats are supported? ● Most files formats are supported, e.g. jpeg, swf, doc, xls ● Can divide the network into 2 segments to get faster response? ● Buy one EGX300 and one EGX100 ● Do we support other web browsers? ● Our pages can be viewed in other browsers Schneider Electric - Division - Name – Date 43 FAQ Continuation ● Do we support ION protocol? ● At this time, we do not support ION protocol. ● How much memory does EGX300 support? ● 512 Mb ● How many e-mails will be sent from the EGX300 for logging? ● The number of e-mails sent will be determine by number of devices logged. ● Does EGX300 support SNMP? ● Yes, it supports the standard MIB (II). Schneider Electric - Division - Name – Date 44 For more information … ● Please visit www.PowerLogic.com Schneider Electric - Division - Name – Date 45 Appendix ● User interface following in the next slides Schneider Electric - Division - Name – Date 46 EGX300 user interface – real time data Schneider Electric - Division - Name – Date 47 EGX300 user interface – maintenance Schneider Electric - Division - Name – Date 48 EGX300 user interface – summary device Schneider Electric - Division - Name – Date 49 EGX300 user interface – summary device Schneider Electric - Division - Name – Date 50 EGX300 user interface – summary device Schneider Electric - Division - Name – Date 51 EGX300 user interface – summary device Schneider Electric - Division - Name – Date 52 EGX300 user interface – summary device Schneider Electric - Division - Name – Date 53 EGX300 user interface – diagnostics Schneider Electric - Division - Name – Date 54 EGX300 user interface – setup Schneider Electric - Division - Name – Date 55 EGX300 user interface – setup Schneider Electric - Division - Name – Date 56 EGX300 user interface – setup Schneider Electric - Division - Name – Date 57 EGX300 user interface – setup Automatically detect networked devices • Simplifies initial setup • Promotes easy system expansion Schneider Electric - Division - Name – Date 58 EGX300 user interface – setup Schneider Electric - Division - Name – Date 59 EGX300 user interface – setup Device Logging Choose the logging intervals Choose from a customizable list of logging topics and log up to 10 Schneider Electric - Division - Name – Date 60 EGX300 user interface – setup Schneider Electric - Division - Name – Date 61 EGX300 user interface Choose to receive the most up-to-date data or all data sent via email or ftp Schneider Electric - Division - Name – Date 62 EGX300 user interface – setup Password protection and controlled network access ensures data and system security Replace with Fake user ID Schneider Electric - Division - Name – Date 63 EGX300 user interface – setup Schneider Electric - Division - Name – Date 64 EGX300 user interface – setup Schneider Electric - Division - Name – Date 65 EGX300 user interface – setup Schneider Electric - Division - Name – Date 66 EGX300 user interface – setup Schneider Electric - Division - Name – Date 67 EGX300 user interface – basic readings Schneider Electric - Division - Name – Date 68 EGX300 user interface – accumulated value Schneider Electric - Division - Name – Date 69 EGX300 user interface -- Schneider Electric - Division - Name – Date 70