BERKER B.IQ
DESIGN & VERSIONS
CONSTRUCTION & DIMENSIONS
STRUCTURE OF THE DISPLAY
PARAMETER
TECHNICAL DATA
08.2013 Ze
Bekrer B.IQ
2
B.IQ
DESIGN
 Frameless KNX pushbutton
 4 different Materials

Glass
■ Polarwhite
■ Black

Aluminium
 Plastic
 Stainless steel
08.2013 Ze
Bekrer B.IQ
3
B.IQ
VERISONS
The Berker B.IQ is available in
different verions:
 1gang
 2gang
 3gang
 4gang
 3gang with RTR
 4gang with RTR
 5gang with RTR
08.2013 Ze
Bekrer B.IQ
4
B.IQ
DESIGN & VERSIONS
B.IQ push button 1- 4
gang
B.IQ push button with RTR and
display 3 - 5gang
Uniform installation height
08.2013 Ze
Bekrer B.IQ
5
B.IQ
DESIGN & VERSIONS
Uniform
installation height
B.IQ push button
with RTR and
display 3gang
(also 4gang
and 5gang)
B.IQ push
button 4gang
B.IQ push
button 1gang
08.2013 Ze
Bekrer B.IQ
6
B.IQ
1- 4GANG STANDARD
 Productname:
B.IQ Pushbutton, X-gang
 Order No:
08.2013 Ze
Bekrer B.IQ
7516 x0 9x
7
B.IQ
1- 4GANG STANDARD
 with anti-dismantling protection
 with blue operation LED and white
status LEDs
 for switch, push-button, dimmer and
shutter functions
 dimming / position value transmitter 1
byte
 extension unit for light scene pushbutton
08.2013 Ze
Bekrer B.IQ
8
B.IQ
1- 4GANG KOMFORT
 Productname:
B.IQ Pushbutton, X-gang comfort
 Order No:
08.2013 Ze
Bekrer B.IQ
7516 x5 9x
9
B.IQ
1- 4GANG KOMFORT
Standard functions plus:
 value transmitter for dimming,
position, brightness and temperature
values 1 and 2 byte
 cyclic transmission can also be
started via switching object
 alarm telegram after disconnection
from bus coupling unit 1 bit or 1 byte
 single and two push-button operation
parameterisable
 one push-button operation for
switching, pushing, shutters and
dimming
 activation of second user level via
object
08.2013 Ze
Bekrer B.IQ
10
B.IQ
3- 5 GANG WITH RTR
 Productname:
B.IQ Pushbutton, X-gang with
thermostat and display
 Order No:
08.2013 Ze
Bekrer B.IQ
7566 x5 9x
11
B.IQ
3- 5 GANG WITH RTR
 with anti-dismantling protection
 With blue operation LED and white
status LEDs
 LC display with symbols and
illumination, switchable via object
 display of operating mode, controller
lockout, room/outside temperature,
time (clock required)
 text display (ASCII-format)
 with 2 additional display buttons
 end customer display scope
parameterisable
08.2013 Ze
Bekrer B.IQ
12
B.IQ
3- 5 GANG WITH RTR
 for switch, push-button, dimmer,
shutter and room thermostat
functions
 value transmitter for dimming,
position, brightness and temperature
values 1 and 2 byte
 extension unit for light scene pushbutton
 single and two push-button operation
parameterisable
 one push-button operation for
switching, pushing, shutters and
dimming
08.2013 Ze
Bekrer B.IQ
13
B.IQ
3- 5 GANG WITH RTR
 area dimming
 shutter operation concept short-longshort and long-short parameterisable
 alarm telegram after disconnection
from bus coupling unit 1 bit, 1 or 2
byte
 with room temperature timer and 2week timer functions
 For individual single room
temperature control
 controller operating modes: comfort,
standby, night and frost/heat
protection mode
08.2013 Ze
Bekrer B.IQ
14
B.IQ
3- 5 GANG WITH RTR
 for heating and/or cooling mode
with/without auxiliary step
 control parameter for heating /
cooling unit pre-set
 temperature measurement via
internal and/or external sensor with
mean value formation
 separate window contact object
 indicator objects for heating and
cooling
 with valve protection function
 object for controller status
 with flash-controller technology
08.2013 Ze
Bekrer B.IQ
15
DESIGN & VERSIONS
CONSTRUCTION & DIMENSIONS
STRUCTURE OF THE DISPLAY
PARAMETER
TECHNICAL DATA
08.2013 Ze
Bekrer B.IQ
16
B.IQ
CONSTRUCTION & DIMENSIONS
08.2013 Ze
Bekrer B.IQ

Labelling field (optional)

Spacer plate for
the display (only required if
the labelling field is used)

Base plate with display

Transparent protective cover
for the electronics
(do not remove or paint over)

Design cover
(only to be fitted once all
installation work has been
completed)
17
B.IQ
CONSTRUCTION & DIMENSIONS
08.2013 Ze
Bekrer B.IQ

Base plate with display

Guide pins

Securing screws for base
plate / bus coupling unit
supporting ring.

User interface (PEI)
18
B.IQ
CONSTRUCTION & DIMENSIONS
Display / display
buttons
Labelling
field
Function
buttons /
rocker
switches
Status
LEDs
Operating
LED
08.2013 Ze
Bekrer B.IQ
19
B.IQ
CONSTRUCTION & DIMENSIONS
08.2013 Ze
Bekrer B.IQ
20
DESIGN & VERSIONS
CONSTRUCTION & DIMENSIONS
STRUCTURE OF THE DISPLAY
PARAMETER
TECHNICAL DATA
08.2013 Ze
Bekrer B.IQ
21
B.IQ
STRUCTURE OF THE DISPLAY
Lower values (left display
button)
Frost / heat protection
Comfort extension
(“Frost / heat protection”
operating mode)
Accept a change into a
sub-menu
“Comfort” operating mode
Switch off room cooling in the
event of condensation on the
cooling unit
“Standby” operating mode
A change made to the required
value using the display buttons
“Night” operating mode
Programming mode
Comfort extension
(“Night” operating mode)
08.2013 Ze
Bekrer B.IQ
Operation of the display buttons
or individual rockers or operation of
the device locked
Timer active or control display in
respective programming
Reserved for future
developments
Heating energy is supplied
or control display in the
programming
Cooling energy is supplied
or control display in the
programming
Change the menu item (right
display button)
Raise the value (right display
button)
22
DESIGN & VERSIONS
CONSTRUCTION & DIMENSIONS
STRUCTURE OF THE DISPLAY
PARAMETER
TECHNICAL DATA
08.2013 Ze
Bekrer B.IQ
23
B.IQ
PARAMETER / ETS CONFIGUTATION
 The standard and the comfort B.IQ‘s can be configured with
Parameters directly in the ETS.
 The B.IQ with Display and temperature control needs a plug-in which
has to be installed. This is available with the Application on
www.berker.com
 The next sheets will show the parametration of a RTR B.IQ
08.2013 Ze
Bekrer B.IQ
24
B.IQ
PARAMETER / ETS CONFIGUTATION
08.2013 Ze
Bekrer B.IQ
25
B.IQ
PARAMETER / ETS CONFIGUTATION
 Gerneral settings
08.2013 Ze
Bekrer B.IQ
26
B.IQ
PARAMETER / ETS CONFIGUTATION
 Display
08.2013 Ze
Bekrer B.IQ
27
B.IQ
PARAMETER / ETS CONFIGUTATION
 Push button function
08.2013 Ze
Bekrer B.IQ
28
B.IQ
PARAMETER / ETS CONFIGUTATION
 Rocker / Push button function
08.2013 Ze
Bekrer B.IQ
29
B.IQ
PARAMETER / ETS CONFIGUTATION
 Status LED
08.2013 Ze
Bekrer B.IQ
30
B.IQ
PARAMETER / ETS CONFIGUTATION
 Addressing by drag & drop
08.2013 Ze
Bekrer B.IQ
31
B.IQ
PARAMETER / ETS CONFIGUTATION
 Addressing
08.2013 Ze
Bekrer B.IQ
32
B.IQ
PARAMETER / ETS CONFIGUTATION
 Room temperature regulation
08.2013 Ze
Bekrer B.IQ
33
B.IQ
PARAMETER / ETS CONFIGUTATION
 Room temperature regulation
08.2013 Ze
Bekrer B.IQ
34
B.IQ
PARAMETER / ETS CONFIGUTATION
 Temperature measuring
08.2013 Ze
Bekrer B.IQ
35
B.IQ
PARAMETER / ETS CONFIGUTATION
 Room temperature regulation
08.2013 Ze
Bekrer B.IQ
36
DESIGN & VERSIONS
CONSTRUCTION & DIMENSIONS
STRUCTURE OF THE DISPLAY
PARAMETER
TECHNICAL DATA
08.2013 Ze
Bekrer B.IQ
37
B.IQ
TECHNICAL DATA
Supply
Voltage (via bus line):
21–32 V DC
Power consumption (via bus line):
typically 360 mW
Rockers (buttons)
3-5 (6-10)
Graphics display with 2 display buttons
Two lines with symbol bar
Measuring range
0° C to 40° C
Resolution
0.1 K
Air humidity
0% to 95% (non-condensing)
Resolution
1 minute
Gang variation
max. 8 minutes a day (use external
clock!; update every hour over the bus)
Connections
Flush-mounted bus coupling unit plus
(7504 00 03)
User interface: 2 x 5-pin male connector
Index of protection
IP 20
Ambient temperature range
Mode
-5 to +45°C
Storage / transportation
-20 to +60 °C (storage at over +45°C will
reduce the working life)
Controls and displays
Internal temperature sensor
Internal clock
Assembly
Plug into flush-mounted bus coupling unit
Mounting orientation
any
Dimensions (W x H x D)
depending on design
08.2013 Ze
Bekrer B.IQ
see dimensional drawings