Dardo Communication Module Dardo Communication Module Characteristics Configuration and connection Web Server FAQ Schneider Electric - BU Quality Emergency Lighting - Mauro Grilli 2 Characteristics Schneider Electric - BU Quality Emergency Lighting - Mauro Grilli 3 Dardo Communication Module DCM Characteristics ● Characteristics: ● Supervision of the products, using: ● ● ● ● Ethernet. Serial Line RS232. Serial Line RS485. GSM Modem or Analog Modem. ● Devices checked: ● Dardo Plus. Schneider Electric - BU Quality Emergency Lighting - Mauro Grilli 4 Dardo Communication Module DCM Characteristics ● Characteristics ● Mains 24 V DC +/- 10% 100 mA. ● DCM Configuration using PC connected directly to DCM with Ethernet crossing cable (Ethernet crossing cable not included). ● Dardo Plus connection with RS485 Serial Line. ● Lithium internal battery only for the calendar memory. Schneider Electric - BU Quality Emergency Lighting - Mauro Grilli 5 Dardo Communication Module DCM Ethernet Characteristics PC (cross ethernet) LAN Dardo Plus DCM slave Reboot/Reset button PC Lite (RJ45-DB9 adapter) PC Map (RJ45-DB9 adapter) Analog modem GSM modem RS485 USB RS232 (RJ45) Not used Schneider Electric - BU Quality Emergency Lighting - Mauro Grilli 6 Configuration and connection Schneider Electric - BU Quality Emergency Lighting - Mauro Grilli 7 Dardo Communication Module DCM Configuration ● Configuration - Dardo Plus connected with RS485 Serial Line Supervision with RS232 PC connection DCM RS485 Dardo Plus RS485 1 2 3 4 5 1 DCM RS232 1 2 3 4 5 6 7 8 6 5 4 3 2 1 PC RS232 1 5 3 2 1 ● DCM ● Set-up the Central unit connected to the System - Max 32. ● Set-up RS232 “transparent”. ● Up to 32 products connected to RS485 Serial Line. ● RS485 Line: up to 1200 mt. ● RS232 Line: up to 15 mt. Schneider Electric - BU Quality Emergency Lighting - Mauro Grilli 8 Configuration Dardo Communication Module DCM ● Configuration - Dardo Plus connected with RS485 Serial Line Supervision with Ethernet connection ● DCM ● Set-up the Central unit connected to the System - Up to 32. ● Set-up RS232 “transparent”. LAN ● Up to 32 products connected to RS485 Serial Line. ● RS485 Line: up to 1200 mt. ● RS232 Line: up to 15 mt. DCM RS485 1 2 3 4 5 ACL – Dardo Plus RS485 1 Schneider Electric - BU Quality Emergency Lighting - Mauro Grilli 6 5 4 3 2 1 PC communication not at the same time 1 2 3 4 5 6 7 8 DCM RS232 PC RS232 1 5 3 2 1 9 Dardo Communication Module DCM Configuration ● Configuration - Dardo Plus connected with RS485 Serial Line Supervision with Analogic Modem DCM RS485 1 2 3 4 5 ACL – Dardo Plus RS485 1 1 6 5 4 3 2 1 3 4 5 6 7 8 1 1 ● DCM ● Set-up the Central unit connected to the System Up to 32. ● Set-up RS232 Analogic Modem. Schneider Electric - BU Quality Emergency Lighting - Mauro Grilli 10 5 4 8 3 7 2 6 Dardo Communication Module DCM Configuration ● Configuration - Dardo Plus connected with RS485 Serial Line Supervision with GSM Modem (Compatibility: Zelio 920399 SR2 Mod 02) ACL - Dardo Plus RS485 DCM A RS485 1 2 3 4 5 1 6 5 4 3 2 1 ● DCM ● Set-up the Central unit connected to the System Up to 32. ● Set-up RS232 GSM Modem. DCM RS232 1 3 4 5 6 7 8 Schneider Electric - BU Quality Emergency Lighting - Mauro Grilli DB9 Female soldier view RS232 Modem 1 1 5 4 8 3 7 2 6 11 Web Server Schneider Electric - BU Quality Emergency Lighting - Mauro Grilli 12 Dardo Communication Module DCM Web Server ● Web Server ● Supervision of the Dardo Plus Units with DCM Web Server software. ● Web server is opened with standard Browser (Egg: Explorer). ● DCM Default IP Address: ● 192.168.1.2 ● 255.255.0.0 Schneider Electric - BU Quality Emergency Lighting - Mauro Grilli 13 Dardo Communication Module DCM Web Server ● Web Server ● Serial Port configuration. ● Ethernet parameter configuration. ● Products connected Configuration. ● Commands to Dardo Plus connected. ● Check of the Luminaires state connected to the Dardo Plus. ● SMS or Email notification. ● Log event file of the Dardo Plus connected to DCM when the DCM is not online with other supervisor (PC - Modem). ● Log event file download with PC Lite/MAP software. Schneider Electric - BU Quality Emergency Lighting - Mauro Grilli 14 Dardo Communication Module DCM Web Server ● Web Server - Configuration ● 32 Dardo Plus control units. ● 10 Mobile numbers for notifications. ● 4 E-mail for notifications. Schneider Electric - BU Quality Emergency Lighting - Mauro Grilli 15 FAQ Schneider Electric - BU Quality Emergency Lighting - Mauro Grilli 16 Dardo Communication Module DCM FAQ ● Change language package ● There are 2 language packages: ●Italian English French Spanish. ●English Norwegian Danish Finnish German. 1. Enter with ftp communication with command prompt. 2. Chose the directory where are presents the language package files. 3. Send command “put language file name.lpk”. 4. When the file is uploaded send the command “bye”. Schneider Electric - BU Quality Emergency Lighting - Mauro Grilli 17 Dardo Communication Module DCM FAQ ● How to recover password ● If Password is changed or modified is not possible to recover it, but it will be possible to reset the DCM and restart with the Default Password and configuration. ● Push the front panel Reset button for 30’’. The LED will switch Off/On. ● Be careful because this procedure reset all the parameters and configuration of DCM. ● Make a Back-up of the configuration file during the first set-up and every time is made a new configuration. ● If username was changed, uploading back-up configuration file it will be uploaded also the username present in this file. If the username is forgotten is possible read the username inside the configuration file as text file, whilst password will be default passwords “schneider”. Schneider Electric - BU Quality Emergency Lighting - Mauro Grilli 18 Dardo Communication Module DCM FAQ ● How to recover TCP/IP address 1. Connect serial cable between DCM and PC. 2. Start communication with software as HyperTerminal. 3. Set up communication parameter: 9600/8/none/1/none. 4. Insert Username and Password. 5. Send “tcpip” command and the software will show DCM configuration with all the Ethernet parameters recorded inside the products. Schneider Electric - BU Quality Emergency Lighting - Mauro Grilli 19 Dardo Communication Module DCM FAQ ● Configuration Back-up - file config.ini 1. Open PC Command prompt. 2. Chose the Directory where the configuration file will be saved. 3. Open DCM ftp communication. 4. Command “get config.ini”. 5. Configuration file will be saved in the Directory chosen in step 2. 6. Save the configuration file in case of reset of DCM. 7. Back-up the configuration file every time the configuration is changed. Schneider Electric - BU Quality Emergency Lighting - Mauro Grilli 20 Dardo Communication Module DCM FAQ ● Change configuration file with back-up file - file config.ini If the DCM has been resetted or the configuration is corrupted is possible change the default configuration file with a back-up configuration file, if is present a Back-up configuration file “config.ini”. ●There are 2 methods: ●With Web Server ●With ftp communication Schneider Electric - BU Quality Emergency Lighting - Mauro Grilli 21 Dardo Communication Module DCM FAQ ● Change configuration file with back-up file - file config.ini ● Web Server 1. Enter in DCM Web Server. 2. Menu “Administrator”. 3. Menu “General”. 4. Choose the back-up configuration file “config.ini” in the PC. Schneider Electric - BU Quality Emergency Lighting - Mauro Grilli 22 Dardo Communication Module DCM FAQ ● Change configuration file with back-up file - file config.ini ● ftp communication 1. Enter PC command prompt. 2. Chose the directory where is present the back-up configuration file “config.ini”. 3. Digit ftp “ip address” (DCM Ip Address). 4. User name and password. 5. Send “put config.ini” command. 6. The back-up file will be up-load in the DCM. 7. If the DCM has been resetted also with username and password, with the back-up configuration file the username will be recovered whilst the Password will be the Default password “schneider”. Schneider Electric - BU Quality Emergency Lighting - Mauro Grilli 23 Dardo Communication Module DCM FAQ ● Firmware update ● There are 2 installation files File 1.bin and File 2.bin. ● Is necessary to upgrade before file 1 and after file 2. 1. Enter with ftp communication with command prompt. 2. Chose the directory where are presents the firmware files updated. 3. Send command “put File1.bin”. 4. When the file is uploaded send the command “bye”. 5. Repeat step 1. 6. Send command “put File 2.bin”. 7. When the file is uploaded send the command “bye”. Schneider Electric - BU Quality Emergency Lighting - Mauro Grilli 24