Sales Presentation Powerwave 60-500kw

advertisement
PowerWave 33
continuos power protection availability
10 November 2011
Unmatched
Newave SAPower Performance, Ed. 10.11.2011
1
PowerWave 33
Contents
•
The range
•
The performances
•
Options
•
Additional info
10 November 2011
Newave SA
2
PowerWave 33
PowerWave 33
Unmatched Power Performances
10 November 2011
Newave SA
3
The full range
Technology: On-Line, transformer less
Power range: 60-80-100-120-160-200-250-300-400-500 kVA/kW (3/3)
Rated at PF = 1
400-500 kW
250-300 kW
120-160-200 kW
60-80-100 kW
10 November 2011
Newave SA
4
The range with battery enclosures
Power range: 60-80-100 kVA/kW (3/3)
Rated at PF = 0.9
60-80-100 kVA
with Battery Enclosure B
Up to 120 battery blocks (3 x 40)
60-80-100 kVA
with Battery Enclosure A
up to 80 battery blocks (2 x 40)
60-80-100 kW
10 November 2011
Newave SA
5
PowerWave 33
•
Design
•
Compactness
•
Type of ventilation
•
Battery’s enclosures and enhancement
•
Input electrical performances
Unmatched power performances
•
Efficiency
•
Full output active power kVA=kW
10 November 2011
Newave SA
6
The Design of PowerWave 33
Mix & Match
IT design
10 November 2011
Newave SA
7
The Design of PowerWave 33
Mix & Match Data Centre & technical room environment
10 November 2011
Newave SA
8
The compactness of PowerWave 33
FEATURES
60-80-100 kW
550 x 1820 x 750 mm
From 230 to 245kg
Compact size
Low weight
Full front access only
60-80-100 kVA with BAT-ENC A
970 x 1820 x 750 mm
From 250 to 285 kg (w/o batt.)
BENEFITS
Space costs savings
60-80-100 kVA with BAT-ENC B
1180 x 1820 x 750 mm
From 270 to 305 kg (w/o batt.)
10 November 2011
Less transportation costs
No need for special floor basement
No rear access needed
Newave SA
9
The compactness of PowerWave 33
FEATURES
120-160-200 kW
850 x 1820 x 750 mm
From 280 to 310 kg
Compact size
Low weight
Front access only
250-300 kW
1100 x 1920 x 750 mm
From 390 to 410 kg
BENEFITS
Space costs savings
400-500 kW
1650 x 1994 x 850 mm
From 950 to 1000 kg
10 November 2011
Less transportation costs
No need for special floor basement
No rear access needed
400-500kVA can be placed against the wall
Newave SA
10
The ventilation of PowerWave 33
60-300kW: front - rear
10 November 2011
400-500kW: front - top
Newave SA
11
The battery’s enclosures and chargers
Battery chargers
60-100kW: 25A battery charger
120-200kW: 50A battery charger
250-300kW: 60A battery charger
400-500kW: 100A battery charger
40 block in each
battery side
column
Battery Encl. A
Up to 80
battery blocks
of 28Ah
10 November 2011
Battery Encl. B
Up to 120
battery blocks
of 28Ah
Newave SA
12
Battery’s enhancement
FEATURES
Allowable battery blocks at full power
Battery
60-160kW: from 44 to 50 battery blocks
200kW:
50 battery Blocks
250-300kW: from 44 to 50 battery blocks
400-500kW: from 44 to 50 battery blocks
Ripple free through battery charger
No battery operation during load jump
Battery temp. compensation (option)
BENEFITS
Flexibility for autonomy rating
Increase of battery life expectancy
10 November 2011
Newave SA
13
Input electrical performances
FEATURES
Wide input voltage range:
Input
300-460V @ 100 % load (-25%/+15%)
280-460V @ 80% load (-30%/+15%)
240-460V @ <60 % load (-40%/+15%)
Wide input frequency range:
35–70 Hz
BENEFITS
Less need for battery operation
Increase of battery expectance life
10 November 2011
Newave SA
14
Input electrical performances
Rectifier
FEATURES
Improved input PFC:
>0.99 @ 100% load
Low input THDI:
<3.5% @ 100% load
BENEFITS
Smaller cables and fuse size
No phase compensation device required
No malfuntion and false tripping
No extra heating losses in transformers
No gen-set oversized
Longer plant life
Less energy costs
10 November 2011
Newave SA
15
Unmatched power performance
Efficiency
AC/AC
FEATURES
Best in class efficiency:
up to 96% in on-line mode
Up to 99% in eco-mode
BENEFITS
Energy bill savings
Air conditioning cost savings
Reduced TCO
10 November 2011
Newave SA
16
The efficiency of PowerWave 33
Do not look only at the initial costs
but consider the operating ones
for ROI calculation
Difference in
efficiency
Load (kW)
2%
3%
4%
5 years
10 years
5 years
10 years
5 years
10 years
100
13’734
27’469
20’825
41’649
28’069
56’139
500
68’673
137’346
104’123
208’247
140’348
280’696
137’346
274’693
208’247
416’493
280’697
561’394
1000
COST SAVINGS (Euros)
• kWh cost = 0.10 Euro
• Cooling factor = 0.4
10 November 2011
Newave SA
17
Unmatched power performance
Full output active power kVA=kW
Inverter
FEATURES
Voltage tolerance:
THDU < 2% with linear load
THDU < 3% with non-linear load
Voltage regulation:
Static +/-1%, Dynamic +/-4%
Rated up to a power factor = 1
BENEFITS
Excellent voltage quality/stability
Compatible with all loads (blade servers)
without de-rating
10 November 2011
Newave SA
18
Master your power
≥ 44 batt. blocks (except 200kVA only 50 blocks)
11% more active power than UPS rated at 0.9
25% more active power than UPS rated at 0.8
10 November 2011
Newave SA
19
Master your power
* Only with 50 battery blocks
10 November 2011
Newave SA
20
Master your power
10 November 2011
Newave SA
21
Manage your power
* Only with 50 battery blocks
10 November 2011
Newave SA
22
Parallelability (optional)
Parallel configuration using
Static Transfer Switch
STS
Load
•
Up to 10 UPS in DPA parallel configuration
•
Parallel Kit factory mounted only
•
Synchronisation Kit (only if equipped with parallel kit and
only factory mounted)
10 November 2011
Newave SA
23
Customers Interfaces (standard)
RS232 on USB port (UPS Protocol)
RS232 on D-Sub 9P port (UPS Protocol)
Customer Interfaces : Inputs
DRY PORT
Customer Interfaces :
Outputs
DRY PORT
1 Remote Shut down
1 GEN-ON
1 Programmable Customer’s Inputs (60-300kVA) , External manual by-pass (400-500kVA)
1 Temp. Sensor for Battery Control
5 voltage free contacts(60-300kVA), 6 voltage free contacts(400-500kVA)
For remote signalling and automatic computer shutdown
1 x RS485 on RJ45 port (remote panel)
1 x RS485 on RJ45 port (Multidrop)
1 x SNMP Slot
1 x NWWatch slot
10 November 2011
Newave SA
24
Options
Available and structured options
• Back feed protection
• Parallel kit (one additional PCB + one parallel adapter)
• Parallel cables with different lenghts
• Synchronization kit (available only with parallel kit)
• Connectivity (SNMP,Multidrop,etc.)
• Elevation kit
• Manual by-pass switch (only for 400-500kVA)
On request
• I/O transformers
• IP 21 Protection (60-300kW only)
10 November 2011
Newave SA
25
400-500kVA front view
Optional
Output CB
Back-feed CB
Rectifier SW
Customer interface
By-pass SW
Manual by-pass SW
Output SW
10 November 2011
Newave SA
26
Certificate
•Electrosuisse certificate
Newave will get a performance certificate from ElectroSuisse for a 100–200–300-500kVA
(independent institute comparable to TŰV)
10 November 2011
Newave SA
27
Thank you for the attention
10 November 2011
Newave SA
28