PowerWave 33 continuos power protection availability 10 November 2011 Unmatched Newave SAPower Performance, Ed. 10.11.2011 1 PowerWave 33 Contents • The range • The performances • Options • Additional info 10 November 2011 Newave SA 2 PowerWave 33 PowerWave 33 Unmatched Power Performances 10 November 2011 Newave SA 3 The full range Technology: On-Line, transformer less Power range: 60-80-100-120-160-200-250-300-400-500 kVA/kW (3/3) Rated at PF = 1 400-500 kW 250-300 kW 120-160-200 kW 60-80-100 kW 10 November 2011 Newave SA 4 The range with battery enclosures Power range: 60-80-100 kVA/kW (3/3) Rated at PF = 0.9 60-80-100 kVA with Battery Enclosure B Up to 120 battery blocks (3 x 40) 60-80-100 kVA with Battery Enclosure A up to 80 battery blocks (2 x 40) 60-80-100 kW 10 November 2011 Newave SA 5 PowerWave 33 • Design • Compactness • Type of ventilation • Battery’s enclosures and enhancement • Input electrical performances Unmatched power performances • Efficiency • Full output active power kVA=kW 10 November 2011 Newave SA 6 The Design of PowerWave 33 Mix & Match IT design 10 November 2011 Newave SA 7 The Design of PowerWave 33 Mix & Match Data Centre & technical room environment 10 November 2011 Newave SA 8 The compactness of PowerWave 33 FEATURES 60-80-100 kW 550 x 1820 x 750 mm From 230 to 245kg Compact size Low weight Full front access only 60-80-100 kVA with BAT-ENC A 970 x 1820 x 750 mm From 250 to 285 kg (w/o batt.) BENEFITS Space costs savings 60-80-100 kVA with BAT-ENC B 1180 x 1820 x 750 mm From 270 to 305 kg (w/o batt.) 10 November 2011 Less transportation costs No need for special floor basement No rear access needed Newave SA 9 The compactness of PowerWave 33 FEATURES 120-160-200 kW 850 x 1820 x 750 mm From 280 to 310 kg Compact size Low weight Front access only 250-300 kW 1100 x 1920 x 750 mm From 390 to 410 kg BENEFITS Space costs savings 400-500 kW 1650 x 1994 x 850 mm From 950 to 1000 kg 10 November 2011 Less transportation costs No need for special floor basement No rear access needed 400-500kVA can be placed against the wall Newave SA 10 The ventilation of PowerWave 33 60-300kW: front - rear 10 November 2011 400-500kW: front - top Newave SA 11 The battery’s enclosures and chargers Battery chargers 60-100kW: 25A battery charger 120-200kW: 50A battery charger 250-300kW: 60A battery charger 400-500kW: 100A battery charger 40 block in each battery side column Battery Encl. A Up to 80 battery blocks of 28Ah 10 November 2011 Battery Encl. B Up to 120 battery blocks of 28Ah Newave SA 12 Battery’s enhancement FEATURES Allowable battery blocks at full power Battery 60-160kW: from 44 to 50 battery blocks 200kW: 50 battery Blocks 250-300kW: from 44 to 50 battery blocks 400-500kW: from 44 to 50 battery blocks Ripple free through battery charger No battery operation during load jump Battery temp. compensation (option) BENEFITS Flexibility for autonomy rating Increase of battery life expectancy 10 November 2011 Newave SA 13 Input electrical performances FEATURES Wide input voltage range: Input 300-460V @ 100 % load (-25%/+15%) 280-460V @ 80% load (-30%/+15%) 240-460V @ <60 % load (-40%/+15%) Wide input frequency range: 35–70 Hz BENEFITS Less need for battery operation Increase of battery expectance life 10 November 2011 Newave SA 14 Input electrical performances Rectifier FEATURES Improved input PFC: >0.99 @ 100% load Low input THDI: <3.5% @ 100% load BENEFITS Smaller cables and fuse size No phase compensation device required No malfuntion and false tripping No extra heating losses in transformers No gen-set oversized Longer plant life Less energy costs 10 November 2011 Newave SA 15 Unmatched power performance Efficiency AC/AC FEATURES Best in class efficiency: up to 96% in on-line mode Up to 99% in eco-mode BENEFITS Energy bill savings Air conditioning cost savings Reduced TCO 10 November 2011 Newave SA 16 The efficiency of PowerWave 33 Do not look only at the initial costs but consider the operating ones for ROI calculation Difference in efficiency Load (kW) 2% 3% 4% 5 years 10 years 5 years 10 years 5 years 10 years 100 13’734 27’469 20’825 41’649 28’069 56’139 500 68’673 137’346 104’123 208’247 140’348 280’696 137’346 274’693 208’247 416’493 280’697 561’394 1000 COST SAVINGS (Euros) • kWh cost = 0.10 Euro • Cooling factor = 0.4 10 November 2011 Newave SA 17 Unmatched power performance Full output active power kVA=kW Inverter FEATURES Voltage tolerance: THDU < 2% with linear load THDU < 3% with non-linear load Voltage regulation: Static +/-1%, Dynamic +/-4% Rated up to a power factor = 1 BENEFITS Excellent voltage quality/stability Compatible with all loads (blade servers) without de-rating 10 November 2011 Newave SA 18 Master your power ≥ 44 batt. blocks (except 200kVA only 50 blocks) 11% more active power than UPS rated at 0.9 25% more active power than UPS rated at 0.8 10 November 2011 Newave SA 19 Master your power * Only with 50 battery blocks 10 November 2011 Newave SA 20 Master your power 10 November 2011 Newave SA 21 Manage your power * Only with 50 battery blocks 10 November 2011 Newave SA 22 Parallelability (optional) Parallel configuration using Static Transfer Switch STS Load • Up to 10 UPS in DPA parallel configuration • Parallel Kit factory mounted only • Synchronisation Kit (only if equipped with parallel kit and only factory mounted) 10 November 2011 Newave SA 23 Customers Interfaces (standard) RS232 on USB port (UPS Protocol) RS232 on D-Sub 9P port (UPS Protocol) Customer Interfaces : Inputs DRY PORT Customer Interfaces : Outputs DRY PORT 1 Remote Shut down 1 GEN-ON 1 Programmable Customer’s Inputs (60-300kVA) , External manual by-pass (400-500kVA) 1 Temp. Sensor for Battery Control 5 voltage free contacts(60-300kVA), 6 voltage free contacts(400-500kVA) For remote signalling and automatic computer shutdown 1 x RS485 on RJ45 port (remote panel) 1 x RS485 on RJ45 port (Multidrop) 1 x SNMP Slot 1 x NWWatch slot 10 November 2011 Newave SA 24 Options Available and structured options • Back feed protection • Parallel kit (one additional PCB + one parallel adapter) • Parallel cables with different lenghts • Synchronization kit (available only with parallel kit) • Connectivity (SNMP,Multidrop,etc.) • Elevation kit • Manual by-pass switch (only for 400-500kVA) On request • I/O transformers • IP 21 Protection (60-300kW only) 10 November 2011 Newave SA 25 400-500kVA front view Optional Output CB Back-feed CB Rectifier SW Customer interface By-pass SW Manual by-pass SW Output SW 10 November 2011 Newave SA 26 Certificate •Electrosuisse certificate Newave will get a performance certificate from ElectroSuisse for a 100–200–300-500kVA (independent institute comparable to TŰV) 10 November 2011 Newave SA 27 Thank you for the attention 10 November 2011 Newave SA 28