RAILROAD COMMISSION OF TEXAS UIC Completion Reporting Guidance Jim Moore, Engineering Specialist II Injection-Storage Permits & Support PRESENTATION OVERVIEW A few examples of RRC webpage research including UIC webpages then a step-by-step guidance for W-2/G-1 online completions for injection / disposal / storage / brine mining wells. Steps include log in, starting or updating a completion packet, entering data, additional forms, submitting, messaging, and problem resolution. Please ask questions during the presentation. 2 RRC HOMEPAGE RRC Online Log In Oil & Gas link or pull-down menu Data – Online Research Queries 3 RRC WEBPAGE Online Research Queries Injection/Disposal Permit Query Oil & Gas Completion Query Oil & Gas Imaged Records Menu 4 RRC WEBPAGE Oil and Gas Imaged Records Query Menu Oil & Gas Well Records GAU Letters Disposal Permits (W-14) Injection/Disposal Permits (H-1/H-1A) These are links to Neubus 5 OVERVIEW INJECTION PERMIT TYPES • H-1/H-1A – Enhanced Recovery – Oil and Gas Waste Disposal • W-14 – Oil and Gas Waste Disposal • H-2 – Brine Mining • H-4 – Underground Hydrocarbon Storage 6 INJECTION/DISPOSAL PERMIT DETAIL • • • • • • Base of Usable Quality Water Casing Record Injection Interval Tubing/Packer Depth Formation Name(s) Permit Special Conditions 7 IMPORTANT PERMIT DATA • Field Name & Field Number – Matches on Completion (Form W-2/G-1), Drilling Permit (Form W-1) • Well Number – Can be changed/updated with Completion UIC Permit Drilling Permit Completion Report Injection Disposal Well 8 COMPLETION OVERVIEW • Packet Data • Form W-2/G-1 Data • Complete Additional Forms – P-4, W-12, L-1 • Load Attachments – W-15, W-12, GAU Letter (formerly TCEQ ), Log Header, others e.g. SWR13 Exception Letter • Submit 9 ONLINE SYSTEM Select Completions 10 FILING OPTIONS & MESSAGES File a New Completion or Update Existing Completion Packet Check Messages for your User ID, or find all Messages for this Operator 11 UPDATE EXISTING PACKET Packet Status: - Submitted View By options Packet Status: - Work In Progress - Pending Operator Update - Hard Copy 12 FILE A NEW COMPLETION PACKET Enter Drilling Permit No. or API No. Click Search 13 FILE A NEW COMPLETION PACKET Multiple Field Names Allowed on Drilling Permit New Packet 14 CHOOSE THE CORRECT DRILLING PERMIT o Multiple Drilling Permits may be populated when searching with API o Drilling Permit’s can have multiple field names o Choosing the Correct Drilling Permit is very Important! 15 PACKET DATA Recommended sequence Definitions for Purpose of Filing Purpose of Filing Type of Completion Well Type Wellbore Profile Packet Type 16 PACKET DATA 17 PACKET DATA 18 PACKET DATA (For WSW, Water Supply Wells) 19 PACKET DATA Wellbore Profile is autopopulated from Drilling Permit, Form W-1 20 PACKET DATA 21 PACKET DATA Tracking Number 3 gets assigned 2 Click Create Packet tab Purpose of Filing Type of Completion Well Type Vertical Profile Packet Type 1 Done 22 PACKET DATA Change Packet Description Save Fill in Well Data Recompletion/Reclass Table 23 PACKET DATA New data fields 01/2014 Enter Permit No. & Date Search for Field & Reservoir Prior Service Type 24 PACKET DATA Search for Field & Reservoir 1 result Select 25 W-2/G-1 PAGE 1 Select W-2 to continue Save, Select Page # Page 1: Potential Test Data 26 W-2/G-1 PAGE 2 System responds with red text warnings if critical data is missing on this page. Save Fill In Well Data 27 W-2/G-1 PAGE 3 New data fields 01/2014 28 W-2/G-1 PAGE 4 New data fields 01/2014 Type of Casing (pull-down) Conductor Surface Intermediate Conventional Production Tapered Production Other Top of Cement Determined By (pull-down) Calculation Temperature Survey Cement Evaluation Log Circulated 29 W-2/G-1 PAGE 4 Active UIC: Tubing & Packer Set Possible exceptions - Brine mining - Hydrocarbon storage - Permit exception 30 Perforations and Packer Depth o Insure Packer, Perforations and Plug Back depth all agree Needs to be less than 100’ unless permitted packer depth allows it Injection Interval Permitted Interval 31 Example Permit o Permitted Interval: 5577-6468’ o Actual Packer depth: 5800’ 32 Example of Inaccurate Reporting o If the permitted interval is reported instead of the completed interval, there is an obvious discrepancy 5577 5800 6468 Actual Perforations: 6000-6150 33 W-2/G-1 PAGE 5 Can be “Yes” for Shut-In UIC Injection/Disposal Interval is within Permitted Interval This table is required for Well Type: Active UIC 34 W-2/G-1 PAGE 5 New data fields 01/2014 List all Work Chronologically, attach Form W-15 for new CIBP, Cement Squeeze, Squeeze Perfs, etc. Process (pull-down) Acid Fracture Cement Squeeze Cast Iron Bridge Plug* Retainer Other 35 W-2/G-1 PAGE 5 When to mark “Encountered”, “Isolated” New data fields 01/2014 36 RRC WEBPAGE Quick recommendation!! Oil & Gas page Compliance & Enforcement Revised SWR 13 – Casing, Cementing, Drilling, Well Control, and Completion Requirements 37 RRC WEBPAGE Compliance & Enforcement page Rule 13 – Geologic Formation Information 38 EXAMPLE FORMATION TOPS 39 W-2/G-1 PAGE 6 Red text warnings if critical data is missing on W-2/G-1. Certify (or Re-certify) Electronic Signature 40 COMPLETE ADDITIONAL FORMS Determine All Required Forms Additional Forms Attachments Select P-4 Certificate of Compliance and Transportation Authority 41 ADDITIONAL FORM: P-4 RRC Gas ID or Oil Lease No. is blank/zero Service Well, Yes Gatherers and/or Purchasers info left blank.* Certify (or Re-certify) 42 ADDITIONAL FORM: P-4 Electronic Signature Certify (or Re-certify) 43 ADDITIONAL FORM: W-12 Well Information Shot Point Information Electronic Signature Certify (or Re-certify) 44 ADDITIONAL FORM: L-1 Basic Electric Log Run Option: Confidentiality Attach Log Header Option: Log Attached Mail Log to RRC Austin Attention: Proration or UIC Electronic Signature Certify (or Re-certify) 45 LOAD ATTACHMENTS Determine All Required Forms Additional Forms Attachments Select W-15 Cementing Report 46 LOAD ATTACHMENTS: W-15 Browse to file location such as your Desktop Formats: .pdf or .tif 1 2 3 Upload Current Attachments 47 RRC WEBPAGE Quick recommendation!! Oil & Gas page Forms - Proposed Form Changes 48 RRC WEBPAGE Proposed Form Changes W-15 Cementing Report 49 LOAD ATTACHMENTS: W-12 Pick 1 of 2 ways to initiate the Upload Attachment step Current Attachments 50 LOAD ATTACHMENTS: W-12 Select W-12 Pull-Down/Pull-Up Menu for Attachment Type 51 COMPLETION OVERVIEW • Packet Data • Form W-2/G-1 Data • Complete Additional Forms – P-4, W-12, L-1 • Load Attachments – W-15, W-12, GAU Letter (formerly TCEQ ), Log Header, others e.g. SWR13 Exception Letter • Submit 52 SUBMIT PACKET Form Name Submit Attachments Service Well, Yes 53 SUBMIT PACKET No No Submit 54 SUBMIT FORMS LACKING • Submit with required forms missing or uncertified?: • Submit with required attachments missing?: Answer 1 or both “Yes” If RRC analysts give Final Approval to the Completion Packet with Forms Lacking, then the Operator will need to provide the missing forms or attachments as soon as possible. Warning letter will follow. 55 SUBMIT PACKET … submitted successfully message 56 PROBLEM RESOLUTION • • • • • Respond to RRC messages on packet Provide additional data, forms, attachments Electronic signature & re-certify all forms released Re-submit packet if released Problem resolution – – – – – W-1 Drilling Permit Amendment H-1/H-1A or W-14 Injection/Disposal Permit Amendment UIC Certified Letter UIC Severance Letter Refer to SWR 16 57 REQUIREMENTS • W-1 Drilling Permit – refer to SWR 5 (512) 463-6751 – New Well – Deepening – Re-enter – Plug Back / Re-Completion in a Different Field • W-15 Cementing Report – check with RRC Districts – New Well – Cement (CS)/ Block Squeeze (CS), Squeeze Perfs, Bridge Plug (CIBP), Plug Back – May relate to Injection/Disposal Permit Special Conditions 58 REQUIREMENTS • W-12 Inclination Report – refer to SWR 11 – New Well, Total Depth > 2000 feet – Re-Enter requires new survey if one was not already filed • exception for Enhanced Recovery – Deepening • Directional Survey – New Drill if the Wellbore Profile is Directional or Horizontal – New Drill if the Wellbore Profile is Vertical • and the W-12 violates 11(c)(1)(A) – Applicable to some Re-Entry, or Deepening – Directional Surveys filed/uploaded by the responsible service company – RRC Engineering Unit & Support (512) 463-1126 59 TERMS & DEFINITIONS • UIC : Underground Injection Control • UIC Number : 9 digit number assigned to Well • H-1 Number : Project number – Fluid Injection Permit No. (label on Packet Data) – F- followed by 5 digits • W-14 Number : Permit number – O&G Waste Disposal Permit No. (label on Packet Data) – 5 digits 60 TERMS & DEFINITIONS • • • • • • API Number : 10-digit number assigned to Well Well Number : D or L D D D L L , D=digit L=letter RRC District No. RRC Oil Lease No. : 5 digit Number RRC Gas ID : 6 digit Number Plat : Lease Map, Survey Location 61 TERMS & DEFINITIONS • H-1 Field Name – correlative to injection/disposal Formation(s) – use deepest if more than one Formation – well is on current schedule in one of the proposed Formations, then keep current Field Name • W-14 Field Name – correlative to disposal Formation(s) more than 2 miles away – or to Formation that is source of disposal fluids 62 63 CONTACT INFORMATION • Jim Moore – Injection / Disposal Permitting – UIC Completions • • • • 512-463-6443 (Direct) 512-463-6792 (Main) 512-463-6780 (Fax) Jim.Moore@rrc.state.tx.us 64