MPSEDC Topics • • • • • • Introduction of MPSWAN Structure of MPSWAN POP locations details Network Diagram POP Equipment Details IP Address Allocation MPSEDC Introduction to MPSWAN • MPSWAN is Madhya Pradesh state wide area Network. • MP SWAN will create a vertical connect(backbone):A)-SHQ = 1 B)-CHQ=10 C)-DHQ=39 D)-BHQ=292 • Horizontal- all department will connect. • MPSWAN will carry data, voice and video traffic. MPSEDC Structure of MPSWAN MPSEDC Summery of POP Locations Name of the MPSWAN POP No. of the vertical POPs SHQ 1 1 152 CHQ 10 10 378 DHQ 39 39 594 BHQ 310 282 286 TOTAL 360 332 1410 MPSEDC No. of the vertical POPs Operational No. of the Horizontal connects operational MPSWAN Network • As per the proposed Network Architecture of SWAN, POPs are divided into four groups: A).Tier-1 POP--NMC at Bhopal.: 01 B).Tier-2 POP -- all Divisional HQ: 10 (Excluding State HQ) C).Tier-3 POP -- all District HQ: 39 D).Tier-4 POP -- at Block/Tehsil HQ: 310 . • Apart from this the proposed SWAN network will be divided into two parts namely:A). SWAN Backbone B).User Departments Connectivity • SWAN Backbone will be through conventional lease lines and all MPSWAN backbone lease. MPSEDC MPSWAN Network diagram MPSEDC POP Equipments Details DG UPS Router Switch Modems IP Phone PDU SNMP MPSEDC 1-Disel Generator A). 8KVA capacity B). Fuel consumption check (by dip level or by flow meter ). C).Check fuel tank, battery status 2-UPS A). Types of UPS :1-CHQ/DHQ = 6KVA UPS with 2hours backup. 2- BHQ= 3KVA UPS with 4-5 hours backup. B).As above diagram please ensure all are connected. C).Ensure that all batteries are connected. D).for any UPS complaint :- log to Emerson toll free no :email id. MPSWAN Equipments Details 3-Router: • Router is a device that connects two networks. A).Router used in MPSWAN network: • SHQ=Cisco 7609 series. • DHQ\CHQ=Cisco 7206 series • BHQ=Cisco 2821 series • horizontal offices=Cisco 2801 & Cisco 1841 series MPSEDC Cisco 7206 Router MPSEDC MPSEDC MPSEDC Interface physical position • In Cisco 7206 Six slots are available in Router Front Side. A)-STM Card install in Slot No. 1 and 3 B)-E1 Card install at Slot No. 4 C)-Slot No. 2,5,6 are Vacant for future use. • In Cisco 7206 Back Side 4 Slots are available:A)-In slot 0(zero) three Gigabit interface B)-one fastethernet interface are available. MPSEDC Cisco 2821 Router MPSEDC Interface physical position • In Cisco 2821 two Slots are available A)-In slot zero, two gigabit interface/ B)- Two serial interface is install. Serial interface is used for WAN connectivity. c)-BRI interface D)-In slot one, two G.703 port are available. One G.703 port is used connectivity between DHQ to BHQ pop and one is vacant for future use. MPSEDC 4-Switch:• Switches are used to connect multiple devices on the same network within a building or campus. • The data link layer (layer 2) of the OSI model. • Two types of Switch- A)-Manageable Switch- The switch can be monitored and adjusted locally or remotely to give you control over network traffic. For security we create the VLANs this type of switch. B)-Unmanageable Switch- does not allow you to make changes and Home-networking equipment typically offers unmanaged switches. • We are use the following Cisco switchesA)-NMC-CISCO-6509 B)-POP Room(All)-CISCO 2960 . MPSEDC Cisco 2960 switch Cisco 2960 switch have 48 ports of Fast Ethernet connectivity MPSEDC 5-Modems • A modem is a communication device that converts binary (digital) signal into analog and analog to binary signals. • We use One/Two Pairs modem for connectivity- • How to Connect Modem in NetworkA)-Both end v.35 B)-Both end Ethernet C)-Customer end V.35 and Exchange end G.703 A-Master modem-Install at BSNL or POP end. B-Slave Modem- Install at Customer end. MPSEDC MPSEDC 6-IP Phone • • IP phone is internet protocol phone. full-feature telephone that provides voice communication over the same data network. • When IP phone is registered, phone displaying the Unique no like 1009 or 1008. MPSEDC Cisco 7970 IP phone MPSEDC 7-PDU(Power Distribution Unit • PDU reboot abilities for network access to remote sites and data center equipment the Switched POPS Cabinet . •PDU provides per outlet measurements of current, voltage, power (kW), apparent power, crest factor, and power factor. 8-Simple Network Management Protocol (SNMP) •SNMP is the most widely used network management solution for our networks. •It is an open standard-based framework that is simple but yet flexible enough to manage many different types of devices. o o With the help of this Tool we can Monitor our POP network equipment and Horizontal Client. Fill the IP address of horizontal and also description. Ping Traceroute Show run Show ip int brief Show ip protocol Show ? Ping is a first command to check Network connectivity. If we phase a problem in our Network then we use ping command to check connectivity. First we ping Gateway means ip configure at router gigabit port those are connect to switch. If we get proper response of our gateway means problem is not local end, after that we ping our next hop ip(If we check network from BHQ then next hop ip is DHQ wan ip , if we check network from DHQ then next hop ip is CHQ wan ip and If we check network from CHQ then next hop ip is SHQ wan ip . IP Address Allocation MPSEDC IP address An IP address is a 32-bit number that uniquely identifies a host (computer or other device, such as a printer or router) on a TCP/IP network. IP addresses are normally expressed in dotted-decimal format, with four numbers separated by periods, such as 192.168.123.132. MPSEDC IP Address Classification Class MPSEDC Leftmost bits Start address Finish address A 0xxx 0.0.0.0 127.255.255.255 B 10xx 128.0.0.0 191.255.255.255 C 110x 192.0.0.0 223.255.255.255 D 1110 224.0.0.0 239.255.255.255 E 1111 240.0.0.0 255.255.255.255 We are using two IP pools 10.124.x.x/16 and 10.125.x.x/16 in our network. From these pools ip has been created for all horizontal and verticals location. For ex. Gwalior district block IPs and department IPs has been allotted as follows:- MPSEDC Gwailor DHQ - IP Schema WAN IP WAN IP Subnet PTP Total PTP Tehsil/Sub Subnet Gigaethernet Sr. connecting to Connectivity Network Division/ connecting to port Port IP of No. SHQ/DHQ (E1 for for Block name CHQ/BHQ (E1 Router Link) /30 Horizontal/30 Horizontal Link) /30 10.124.86.2 10.124.86.4 & 10.124.87.0 127 Switch IP address BHQ Off RF/LAN IP address Range allocated /25 10.124.88.2 10.124.88.0/24 1 Gwalior 10.124.86.1 2 Ghatigaon 10.124.89.1 10.124.89.2 10.124.89.4 31 10.124.89.129 10.124.89.130 10.124.89.128 3 Dabra 10.124.90.1 10.124.90.2 10.124.90.4 31 10.124.90.129 10.124.90.130 10.124.90.128 4 Bhitrarwar 10.124.91.1 10.124.91.2 10.124.91.4 31 10.124.91.129 10.124.91.130 10.124.91.128 5 Chinar 10.124.92.1 10.124.92.2 10.124.92.4 31 10.124.92.129 10.124.92.130 10.124.92.128 10.124.88.1 MPSEDC Prepared ByAshish Dhote (MPSWAN) State IT Center Bhopal