Key Sales Features






2
Simple to Use with Full Text Menu
Graphical User Interface
Proximity Arm / Part Arm / Disarm
Zone, User, Output, Schedule, Holiday &
Reader Text
SMS Enabled
Appearance and Simplicity
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
Key Hardware Features





3
1 Amp Continuous Power Without
Heatsink
PTC Fused Power SIREN – LAN - AUX
Status LED’s Red = Dialler, Green
= Power
Flash Upgradeable
BOSCH 3 Year Warranty (Return To Base)
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
Key Keypad Features







4
Graphical and Icon mixture with pop
up windows
Adjustable Backlight, Contrast,
Volume
Single-Multiple-Master Partition
all in 1 Keypad
Dedicated ON / OFF / PART keys
Real Time Clock and Temperature
Display
Up to 8 keypads per system
Optional prox-readers built into
keypads.
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
Key Input Features – Solution 64 & 16
Plus
8 Zones + Tamper per Zone on Base
Panel
16 Zones Split EOL 3k3 / 6k8 on
Base Panel
Expandable to 64 Zones Hardwired or
RF (Sol 64)
- 8 Partitions/Areas.
16 Zones Hardwired or RF (Sol 16+)
- 4 Partitions/Areas




Inverted Seal for N/O on Split
 Selectable
EOL
EOL Resistor Values

5
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
Keypad Display Features
Our unique graphical text interface
provides intuitive text prompts for all
users and installers, greatly reducing
end user training and virtually
eliminating the need for an Installation
6
Manual
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
Key Output Features






7
3 Onboard High Power 1amp Outputs +
Relay
Over Current Protected +
Reporting
Selectable Event Type / Polarity
/ Time
2 Horn Speaker Outputs Sound / Speed /
Volume
Monitored Device Missing +
Reporting
Operated Via Scheduled
Timers/Command/Event
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
Key Communication Features






8
CID, GSM, SMS and DOMESTIC
Line Fault and Service Tone
Detection
DTMF Tone Decoder
Area/System arm/disarm, Output control.
CLI Caller Line Identification
2400Baud Upload/Download
Compatible with Commercial Modems
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
Key Access Control Features






9
Proximity Readers Built into Keypads
(8)
External Proximity Readers (6)
(Sol 64 Only)
Timer Schedules (8)
Holiday Lists (8)
Easy Enrolment of Tags
Simple and Cost Effective Access
Solution
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
Key RPS Features






10
RPS Windows based program
SQL Server - Single or Multi User
Based
Summary and Detail Data View
Live Interactive Mode
PDF Formatted Reports
Layout Identical to Panel
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
Key Diagnostic Features






11
Input Resistance Measured and
Displayed
256 Event Memory Log
Output Current Overload
System Voltages at Panel and
Peripherals
Temperature at Panel and
Peripherals
Version and Revision Number of all
Modules
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
Standard Features
• Country Selectable
• Sensor Watch
• Area Watch
• Line Fault Detection
• Dial and Busy Tone Detection
• Reports in CID, SIA, Email, SMS, Domestic, and
Voice.
• Redundant Reporting
• Dual Reporting
• 32 digit Telco numbers
• Call forward
• SolutionLink RAS software
• CLI Smart Answer mode
• 16 zones with programmable EOL and pulse count
• Burglary and Fire report Delay
• Part Mode entry Timer
• Dual Entry Timers
12
• 3 fully supervised and protected high current
outputs
• 1 change over Form C,
2amp relay
• Graphic Keypad with master area control and LED
backlight
• Proximity Reader built into keypad (Optional)
• 48 users with variable pin lengths 1-8 digits
• 8 Areas Solution 64, 4 Areas Solution 16 Plus
• 8 Graphic Keypads per system with Text Prompting
• Programmable zone, user, output, area text
• In premise wireless compatible
• Service reminder
• User Test Reminder
• Time Executed Functions and Holiday Schedules and
Daylight Savings
• Deadman Timer
• Swinger Siren and Swinger Dialler
• Auto arming and Auto Disarming
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
Component
Details
13
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
Accessory Modules
Current
Accessories
• CM104 - 8/16 Zone Expander
(1 on Sol 16+, 3 on Sol 64)
• CM105 - 16/32 Zone Expander
(1 -
Sol 64 only)
• CM106 - 8/16 Piggy Back Zone Expander
(2 in conjunction with CM105 - Sol 64 only)
• CM110 - 4 Channel Relay Output With 2
Prox Inputs*
(1 on Sol 16+, 3 on Sol 64)
*Prox Inputs inoperable with Sol 16+
14
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
Accessory Modules
Current
Accessories - Continued
• CM120 - 1 Amp Intelligent Power Supply
Module
(1 on Sol 16+, 3 on Sol 64)
• CM195 - Multi RF Receiver Interface
• CM900 - Direct Link Cable
• C900V2 - IP Module
15
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
Graphic Keypads and ICON Keypad (Solution 16i
system)
16
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
Graphic Keypad
Address
Info
Address
Switch
Terminal
s
17
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
Panel Input Outputs
Defaul
t
Switch
Relay
Program
Tamper
Input
18
Serial
Port
Servic
e
Keypad
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
Status
LED’s
16/32 Zone Expander Module
(Sol 64 only)
KEY FEATURES
• Hardwire Zone Expansion 16/32 Zones
• LAN Based Connection To Reduce Cabling
• Ample Terminals For Easy Wiring
• Compatible With CM120 Power Supply Module
• Internal or External Power Supply
Connections
• Dedicated Cabinet Tamper Input
• Compatible With CM106 Piggy-Back
Expander
19
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
• 2 x Enclosure Module Spaces
16/32 Zone Expander
Option
Select
Switch
CM106
Expansion
Board 2
Status
LED’s
20
Zone
Terminal
s
CM106
Expansion
Board 1
(Sol 64 only)
Zone
Power
Select
LAN
Input
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
Tamper
Input
Extern
alPowe
r
Input
8/16 Zone Piggy Back Module
(Sol 64 only)
KEY FEATURES
The CM106 is an 8/16 Piggy-Back Zone Expander provides an additional 8 or 16 hardwired
zone inputs on the Solution-64 panel.
Up to two CM106 boards can be simply plugged
onto the CM105 expander depending on the zone configuration required.
When Alarm and Tamper monitoring is required, two CM106 boards can be fitted providing
48 hardwired zones. When using Split EOL monitoring, simply add one CM106 to provide a
total of 64 hardwired zone inputs. The CM106 also includes 4 additional power
terminals for sensors.
21
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
8/16 Zone Expander Module
(Sol 64 & Sol 16 Plus)
KEY FEATURES
•
•
•
•
22
Hardwire Zone Expansion 8/16 Zones
• Internal or External Power Supply
LAN Based Connection To Reduce Cabling
Connections
Ample Terminals For Easy Wiring
• Dedicated Cabinet Tamper Input
Compatible With CM120 Power Supply Module
• 1 x Enclosure Module Space
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
4 Way Relay Expander Module
(Prox only Sol 64)
KEY FEATURES
• 4 x Relay Outputs in Form C
Configuration
• 2 Amp Contact Rating @ 24VDC
• 2 x Prox Reader Inputs
• Internal / External Reader Power
Selection
• Dedicated Tamper Input
• High Level Lightning Protection
• LAN Monitored
• 4 x Relay Status Indicators
• 1 x Enclosure Module Space
23
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
4 Way Relay Expander Module
Prox
Power
Select
Extern
al
prox
Power
Input
Status
LEDs
Addres
s
Select
Switch
Prox
Power
Outputs
Relay
Terminal
s
24
(Prox only Sol 64)
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
Tamper
Input
Power Supply
KEY FEATURES
• 1 Amp Continuous Rated
• Dual Protected Power Outputs
• Resettable Fuse Protected
• Pulse Battery Charger
• AC Fail Output
• Low Battery Output
• Low Battery Indicator
• Dedicated Tamper Input
• 1 x Enclosure Module Space
25
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
Multi RF Receiver Interface
KEY FEATURES
• 3 x Independent RF Receiver Inputs
• Supports multiple RF vendors including
Bosch
• Inovonics, Ness and Secure Wireless.
• Increases coverage and reliability
• Easy 3 wire connection to panel
• Dedicated Tamper Input
• 1 x Enclosure Module Space
26
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
Remote Programming System
KEY FEATURES
• Built on MS SQL Technology
• Direct, Remote & Ethernet Link
Options
• Online Database / Panel
Synchronization
• Comprehensive User Authority
Levels
• Graphical Schematic Generator
• Remote System Diagnostics
27
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
28
Strictly confidential | Department | MM/DD/YYYY | Filing note | © Robert Bosch GmbH reserves all rights even in the event of industrial
property rights. We reserve all rights of disposal such as copying and passing on to third parties.
Download