Concentrated efficiency in a minimum size! Phaseo ABL4 Regulated switch mode power supplies, 85 to 960 W - Compact In need of space in your cabinets Schneider Electric - Industry Business – OEM – September 2010 2 50% surface savings with the new ABL4 regulated switch mode power supplies Schneider Electric - Industry Business – OEM – September 2010 Designed for industrial machines, they provide an output of 3,5 A to 40 A and usable in single-phase and three-phase installations. 3 Introducing the new Phaseo ABL4 RS/WS power supplies ● The new Phaseo power supplies provide 3.5A to 40A output and are suitable for single-phase and three-phase power supplies. They easily mount inside automation system enclosures due their small size, and they meet the most demanding automation system requirements. ● The new Phaseo ABL4 range completely replaces the previous family of Phaseo power supplies, the ABL8 RP/WP, and when used in conjunction with Phaseo ABL8 function modules, they assure users of continuity of service in the event of a power outage or circuit overload. Schneider Electric - Industry Business – OEM – September 2010 4 Why a product substitution Schneider Electric - Industry Business – OEM – September 2010 5 Gaining in compactness & performances ABL4RS/WP benefits > Up to -50% on size compared to existing ABL8RP/WP > The only one 30A 3 phases power supply on the market. > Integrated redundancy on 20A single phase version > Removable terminals up to 240W Output current ( 24VDC ) 3,5 5 10 20 30 40 Single phase 120…230V to 24V Single phase 120/230V to 24V 3 phases 400…500V to 24V Schneider Electric - Industry Business – OEM – September 2010 480W single phase 6 Main technical differences with the ABL8 RP/WP power supplies n Phaseo ABL8RE Phaseo ABL4 Phaseo ABL8RP/WP Input range single phase 100-240VAC (110-220V DC) 120-230V AC (100-370V DC)* 100-500V AC No DC compatible Input range 3 phases NA 400-500V AC 380-500V AC Boost NO Mini 1,5In / 5s 1,5In / 4s Output overload behaviour Undervoltage protection, auto restart Auto restart Auto or Manual restart ( selectable ) Diagnosis contact NO Yes, closed if Uout>21,6V Yes, closed if out>21,6V Compatibility with functional modules Compatibility with functional modules Yes Yes * Only 85W and 120W Schneider Electric - Industry Business – OEM – September 2010 7 Substitution of Phaseo ABL8RP/WP by Phaseo ABL4 Equivalent ABL8 and ABL4 Power supplies Points to be checked related to the application Installation differences ABL 8RPS24030 Input voltage limits: Input and output terminals reversed ABL 4RSM24035 ● ABL4: 90..264 V ● ABL4: 90..264 V ABL 8RPS24050 ABL 4RSM24050 Resetting of protection: ● ABL4: automatic ● ABL8: selectable, automatic or manual ABL 8RPS24100 ABL 4RSM24100 Input voltage limits: ● ABL4: 90..264 V ● ABL8: 85..550 V Resetting of protection: 120/230 V voltage selection ●ABL4: by link ●ABL8: by terminal ● ABL4: automatic ● ABL8: selectable, automatic or manual ABL 8RPM24200 ABL 4RSM24200 ABL 8WPS24200 ABL 4WSR24200 ABL 8WPS24400 ABL 4WSR24400 ABL4 does not conform to IEC 61000-3-2 (1) Resetting of protection: ●ABL4: automatic ●ABL8: selectable, automatic or manual ●Input and output terminals reversed ●120/230 V voltage selection ●ABL4: by link ●ABL8: by terminal Input and output terminals reversed (1) Standard IEC/EN 61000-3-2 defines the harmonic limits of the input current that can be produced by equipment such as regulated switch mode power supplies ABL4 or ABL8. This standard is only applicable to electrical or electronic devices that are intended for connection to low voltage public distribution systems. This is rarely the case for power supplies higher than or equal to 480 W. Schneider Electric - Industry Business – OEM – September 2010 8 Why select the new Phaseo ABL4 Schneider Electric - Industry Business – Machine Solutions – September 2010 9 Concentrated efficiency in a minimum size 1 2 3 Simplify the maintenance of your installations The diagnostic LED provides instant identification of any system problems. Suitable for your application Voltage adjustment compensates for voltage drops due to cable length. Speed up maintenance work Using plug-in terminals (up to and including the 240 W model. 4 Maximum safety Thanks to a diagnostic contact to report any output voltage problem. 3 2 1 2 4 3 50% gain in the surface area occupied in your cabinets Schneider Electric - Industry Business – OEM – September 2010 1 4 1 2 4 3 3 10 Reduce your costs ● In machine design and manufacture: • Over sizing of power supplies is no longer necessary, thanks to the new Phaseo range from Schneider Electric™ with its energy reserve • Choose exactly what you need for your installations by using the 30 A version • Create an economical redundant power supply solution thanks to the redundancy diode incorporated in the ABL4RSM24200 model. ● In maintenance: • Advanced diagnostics by LED and relay contact. • Snaps on to the Omega rail. • Plug-in terminals up to and including the 240 W model. Schneider Electric - Industry Business – OEM – September 2010 11 Benefit from better service ● Phaseo is also a complete range of functional modules to ensure peace of mind regarding the correct operation of your applications: • Protection against mains power failures with ABL8B buffer modules and battery back-up. • Service continuity with the ABL8RED redundancy module. • Selectivity of 24 VDC circuits with the ABL8PRP output protection module. The buffer module solution The battery back-up solution Micro-outages of a few seconds Outages > a few seconds Schneider Electric - Industry Business – OEM – September 2010 The redundancy solution The output protection solution 12 Reliability of operation ● No voltage drop for an output overload of less than 5 seconds. ● Continuity of operation if one phase is lost (ABL4W). ● The very high efficiency of our power supplies reduces consumption and component heating. ● Multiple protections against: ● output overloads (automatic re-arming when the fault disappears). ● voltage surges generated on the output by switching inductive loads. ● abnormal rises in ambient temperature. Schneider Electric - Industry Business – OEM – September 2010 13 Phaseo, regulated switch mode power supplies & transformers selection guide Schneider Electric - Industry Business – Machine Solutions – September 2010 14 Power supplies Regulated switch mode power supplies ABL 8MEM, ABL 7RM: 7 to 60 W - Rail mounting ABL 8REM, ABL 7RP: 60 to 144 W - Rail mounting ABL4: 85 to 960 W - Compact - Rail mounting Nominal input voltage 100...240 V AC ; 120...250 V DC 100…230 V AC 120 or 230 VAC 400… 500 V AC 24 V DC Connection to worldwide line supplies United States 120 V (1) ; 240 V (2) Single-phase (N-L1) connection Or 2-phase (L1-L2) connection Single-phase (N-L1) connection Single-phase (N-L1) Connection or 2-phase (L1-L2) connection – – Europe 230 V (1) ; 400 V (2) Single-phase (N-L1) connection – Single-phase (N-L1) connection 3-phase (L1-L2-L3) connection – United States 277 V (1) ; 480 V (2) – – – 3-phase (L1-L2-L3) connection – Undervoltage control Yes No No No – Protection (3) Yes, voltage detection. Automatic reset on elimination of the fault Yes, current limitation, Automatic reset on elimination of the fault Yes, current limitation Diagnostics relay – Yes Yes, depending on model Function modules – Yes with buffer module, battery and battery check modules, redundancy module and discriminating downstream protection module Power reserve (Boost) 1.25 to 1.4 In for 1 minute (for ABL 8MEM) No Depending on model: 1.5 to 1.7 In for 5 to 30 seconds No 5 V DC 48 V DC 24 V DC 5 V DC Output voltage Output current 12 V DC 24 V DC 0.3 A ABL8MEM24003 0.6 A ABL8MEM24006 ABL8MEM12020 2A 7… 12 V DC ABL8DCC12020 2.5 A ABL7RM24025 3A ABL8REM24030 ABL7RP4803 ABL 4RSM24035 3.5 A 5A Yes ABL8MEM24012 1.2 A 4A Yes Function modules ABL 8DCC: converters DC/DC ABL8MEM05040 ABL7RP1205 ABL8REM24050 ABL 4RSM24050 ABL 8DCC05060 6A (4) 10 A ABL 4RSM24100 20 A ABL 4RSM24200 ABL 4WSR24200 30 A ABL 4WSR24300 40 A ABL 4WSR24400 Schneider Electric - Industry Business – OEM – September 2010 (1): phase-to-neutral (2): phase-to-phase (3) Against overloads & short circuits (4) Converter module DC/DC, must be used with Phaseo power supply 15 (4) Make the most of your energy Schneider Electric - Industry Business – OEM – September 2010 16