Why select the new Phaseo ABL4

advertisement
Concentrated efficiency
in a minimum size!
Phaseo ABL4
Regulated switch mode power
supplies, 85 to 960 W - Compact
In need of space
in your cabinets
Schneider Electric - Industry Business – OEM – September 2010
2
50% surface
savings
with the new
ABL4 regulated
switch mode
power supplies
Schneider Electric - Industry Business – OEM – September 2010
Designed for industrial machines, they
provide an output of 3,5 A to 40 A and usable
in single-phase and three-phase installations.
3
Introducing the new Phaseo
ABL4 RS/WS power supplies
● The new Phaseo power supplies provide 3.5A
to 40A output and
are suitable for single-phase and three-phase power
supplies. They easily mount inside automation system enclosures due
their small size, and they meet the most demanding automation
system requirements.
● The new Phaseo
ABL4 range completely replaces the
previous family of Phaseo power supplies, the ABL8 RP/WP,
and when used in conjunction with Phaseo ABL8 function modules,
they assure users of continuity of service in the event of a power
outage or circuit overload.
Schneider Electric - Industry Business – OEM – September 2010
4
Why a
product
substitution
Schneider Electric - Industry Business – OEM – September 2010
5
Gaining in compactness
& performances
ABL4RS/WP benefits
> Up to -50%
on size
compared to existing ABL8RP/WP
> The only one
30A 3 phases
power supply on the market.
> Integrated
redundancy on
20A single phase version
> Removable
terminals up
to 240W
Output current ( 24VDC )
3,5
5
10
20
30
40
Single phase 120…230V to 24V
Single phase 120/230V to 24V
3 phases 400…500V to 24V
Schneider Electric - Industry Business – OEM – September 2010
480W single phase
6
Main technical differences with the
ABL8 RP/WP power supplies
n
Phaseo ABL8RE
Phaseo ABL4
Phaseo ABL8RP/WP
Input range single
phase
100-240VAC
(110-220V DC)
120-230V AC
(100-370V DC)*
100-500V AC
No DC compatible
Input range 3 phases
NA
400-500V AC
380-500V AC
Boost
NO
Mini 1,5In / 5s
1,5In / 4s
Output overload
behaviour
Undervoltage
protection, auto restart
Auto restart
Auto or Manual restart
( selectable )
Diagnosis contact
NO
Yes, closed if
Uout>21,6V
Yes, closed if out>21,6V
Compatibility with
functional modules
Compatibility with
functional modules
Yes
Yes
* Only 85W and 120W
Schneider Electric - Industry Business – OEM – September 2010
7
Substitution of Phaseo ABL8RP/WP
by Phaseo ABL4
Equivalent ABL8 and ABL4
Power supplies
Points to be checked
related to the application
Installation differences
ABL 8RPS24030
Input voltage limits:
Input and output
terminals reversed
ABL 4RSM24035
● ABL4: 90..264 V
● ABL4: 90..264 V
ABL 8RPS24050
ABL 4RSM24050
Resetting of protection:
● ABL4: automatic
● ABL8: selectable, automatic or manual
ABL 8RPS24100
ABL 4RSM24100
Input voltage limits:
● ABL4: 90..264 V
● ABL8: 85..550 V
Resetting of protection:
120/230 V voltage
selection
●ABL4: by link
●ABL8: by terminal
● ABL4: automatic
● ABL8: selectable, automatic or manual
ABL 8RPM24200
ABL 4RSM24200
ABL 8WPS24200
ABL 4WSR24200
ABL 8WPS24400
ABL 4WSR24400
ABL4 does not conform
to IEC 61000-3-2 (1)
Resetting of protection:
●ABL4: automatic
●ABL8: selectable, automatic or manual
●Input and output terminals
reversed
●120/230 V voltage selection
●ABL4: by link
●ABL8: by terminal
Input and output
terminals reversed
(1) Standard IEC/EN 61000-3-2 defines the harmonic limits of the input current that can be produced by equipment such as regulated switch mode power supplies ABL4 or ABL8.
This standard is only applicable to electrical or electronic devices that are intended for connection to
low voltage public distribution systems. This is rarely the case for power supplies higher than or equal to 480 W.
Schneider Electric - Industry Business – OEM – September 2010
8
Why select
the new
Phaseo
ABL4
Schneider Electric - Industry Business – Machine Solutions – September 2010
9
Concentrated efficiency
in a minimum size
1
2
3
Simplify the
maintenance of
your installations
The diagnostic
LED provides
instant
identification of
any system
problems.
Suitable for
your application
Voltage
adjustment
compensates for
voltage drops
due to cable
length.
Speed up
maintenance
work
Using plug-in
terminals
(up to and
including the
240 W model.
4
Maximum
safety
Thanks to a
diagnostic
contact to
report any
output voltage
problem.
3
2
1
2
4
3
50% gain in the surface area
occupied in your cabinets
Schneider Electric - Industry Business – OEM – September 2010
1
4
1
2
4
3
3
10
Reduce your costs
● In machine design and manufacture:
• Over sizing of power supplies is no longer
necessary, thanks to the new Phaseo range
from Schneider Electric™ with its energy
reserve
• Choose exactly what you need for your
installations by using the 30 A version
• Create an economical redundant power supply
solution thanks to the redundancy diode
incorporated in the ABL4RSM24200 model.
● In maintenance:
• Advanced diagnostics by LED and relay contact.
• Snaps on to the Omega rail.
• Plug-in terminals up to and including the 240 W
model.
Schneider Electric - Industry Business – OEM – September 2010
11
Benefit from better service
● Phaseo is also a complete range of functional modules to ensure peace
of mind regarding the correct operation of your applications:
• Protection against mains power failures with ABL8B buffer modules and
battery back-up.
• Service continuity with the ABL8RED redundancy module.
• Selectivity of 24 VDC circuits with the ABL8PRP output protection module.
The buffer
module solution
The battery
back-up solution
Micro-outages of a
few seconds
Outages > a few seconds
Schneider Electric - Industry Business – OEM – September 2010
The redundancy
solution
The output
protection solution
12
Reliability of operation
●
No voltage drop for an output overload of less
than 5 seconds.
●
Continuity of operation if one phase is lost
(ABL4W).
● The very high efficiency of our power supplies
reduces consumption and component heating.
● Multiple protections against:
●
output overloads (automatic re-arming
when the fault disappears).
●
voltage surges generated on the output by
switching inductive loads.
●
abnormal rises in ambient temperature.
Schneider Electric - Industry Business – OEM – September 2010
13
Phaseo,
regulated switch
mode power supplies
& transformers
selection guide
Schneider Electric - Industry Business – Machine Solutions – September 2010
14
Power supplies
Regulated switch mode power supplies
ABL 8MEM, ABL 7RM: 7 to 60 W - Rail mounting
ABL 8REM, ABL 7RP: 60 to 144 W - Rail mounting
ABL4: 85 to 960 W - Compact - Rail mounting
Nominal input voltage
100...240 V AC ; 120...250 V DC
100…230 V AC 120 or 230 VAC
400… 500 V AC 24 V DC
Connection
to
worldwide
line
supplies
United States
120 V (1) ; 240 V (2)
Single-phase (N-L1) connection
Or 2-phase (L1-L2) connection
Single-phase (N-L1)
connection
Single-phase (N-L1)
Connection or
2-phase (L1-L2) connection
–
–
Europe
230 V (1) ; 400 V (2)
Single-phase (N-L1) connection
–
Single-phase (N-L1)
connection
3-phase (L1-L2-L3)
connection
–
United States
277 V (1) ; 480 V (2)
–
–
–
3-phase (L1-L2-L3)
connection
–
Undervoltage control
Yes
No
No
No
–
Protection (3)
Yes, voltage detection. Automatic reset on elimination of the fault
Yes, current limitation, Automatic reset on elimination of the fault
Yes, current limitation
Diagnostics relay
–
Yes
Yes, depending on model
Function modules
–
Yes with buffer module, battery and battery check modules, redundancy module and discriminating downstream protection
module
Power reserve (Boost)
1.25 to 1.4 In for 1 minute (for ABL 8MEM)
No
Depending on model: 1.5 to 1.7 In for 5 to 30 seconds
No
5 V DC
48 V DC
24 V DC
5 V DC
Output voltage
Output current
12 V DC
24 V DC
0.3 A
ABL8MEM24003
0.6 A
ABL8MEM24006
ABL8MEM12020
2A
7… 12 V DC
ABL8DCC12020
2.5 A
ABL7RM24025
3A
ABL8REM24030
ABL7RP4803
ABL 4RSM24035
3.5 A
5A
Yes
ABL8MEM24012
1.2 A
4A
Yes
Function modules ABL 8DCC:
converters DC/DC
ABL8MEM05040
ABL7RP1205
ABL8REM24050
ABL 4RSM24050
ABL 8DCC05060
6A
(4)
10 A
ABL 4RSM24100
20 A
ABL 4RSM24200
ABL 4WSR24200
30 A
ABL 4WSR24300
40 A
ABL 4WSR24400
Schneider Electric - Industry Business – OEM – September 2010
(1): phase-to-neutral
(2): phase-to-phase
(3) Against overloads & short circuits
(4) Converter module DC/DC, must be used with Phaseo power supply
15
(4)
Make the most
of your energy
Schneider Electric - Industry Business – OEM – September 2010
16
Download