Spyder® Introduction Agenda • Introductions • Review Spyder Hardware, Software & Accessories • Live Product Demonstration • Spyder Tool - Physical Point Programming - Network Point Programming - Logic Programming - Simulation - Commissioning / Downloading / Alarms & Diagnostics • Spyder Application Library - Library Migration • Spyder Venom Tool 2 Best Practices ZIO review Multi-controller & Plant Applications VAV Balancing 3 Guy Zebrick • Environmental Combustion and Controls division • Sales Representative / Contractor Support Specialist • 20+ Years Honeywell • Branch Commercial Construction Technician • Branch Project Manager • Branch Application / Lead Application engineer • Branch system sales • Contractor Support / Product specialist 4 Spyder Controller Features Integrated Honeywell Actuator Reduce installation costs. AC synchronous actuator increases life of the controller and reduces life cycle costs DC Power Supply Power external field devices without having to add additional power sources. Saves money and time. Integrated On-board Precision Pressure Sensor Floating Actuator Housing Actuator can float inside housing to increase life due to damper shaft run-out Programmable Whatever you need Spyder can be programmed to solve the problem. Actuator De-Clutch Removable Terminal Blocks Hard to reach places are easy to deal with. Sylk Bus A two wire, polarity insensitive bus that provides both 18 Vdc power and communications between a Sylk-enabled sensor and a Sylk-enabled controller. 5 Network Jack and Service Pin Easy access network Jack and service pin for quick installation and easy service. Color Coded Inputs and Outputs Reduce wiring errors and speeds up troubleshooting. Fast Digital Pulse Meter • One Universal Input (UI-1*) is user selectable as a fast digital Pulse Meter • Pulse meter/Counter Input specification - Pulse input specifications: - Max. frequency: 15Hz (54,000 pulses per hour) - Min. pulse width: 20ms (debounced) - Max. chatter: 5ms 6 Spyder VAV Controller with Actuator Controller Model Programmable Type Protocol UI DI AO PVB6436AS VAV BACnet MS/TP 6 4 3 6 YES YES PVL0000AS VAV LonWorks 0 0 0 0 YES YES PVL4022AS VAV LonWorks 4a 0 2 2 YES YES PVL6436AS VAV LonWorks 6 4 3 6 YES YES • 2 Digital Outputs reserved for Integrated Actuator • Integrated Pressure Sensor 7 Velocity Pressure Series 60 Sensor Floating DO (Microbridge) Actuator Spyder VAV Controller w/o Actuator Programmable Type Protocol UI DI AO DO Velocity Pressure Sensor (Microbridge) PVB6438NS VAV BACnet MS/TP 6 4 3 8 YES NO PVL4024NS VAV LonWorks 4a 0 2 4 YES NO PVL6438NS VAV LonWorks 6 4 3 8 YES NO Controller Model • Integrated Pressure Sensor 8 Series 60 Floating Actuator Spyder Unitary Controller Controller Model Series 60 Floating Actuator Programmable Type Protocol PUB6438S Unitary BACnet MS/TP 6 4 3 8 NO NO PUL1012S Unitary LonWorks 1a 0 1 2 NO NO PUL4024S Unitary LonWorks 4a 0 2 4 NO NO PUL6438S Unitary LonWorks 6 4 3 8 NO NO UI DI AO DO • Extended Temperature Rating 9 Velocity Pressure Sensor (Microbridge) BACnet MS/TP LON Programmable Unitary Control Programmable Unitary Controllers Programmable Unitary Controller • Extended Temperature Rated -40° F (-40° C) to 150° F (65.5° C) Programmable VAV Controllers with Actuator Programmable Variable Air Volume Controller • Integrated actuator • Integrated on-board pressure sensor Programmable VAV Controllers w/o Actuator Programmable Variable Air Volume Controller • Integrated on-board pressure sensor PUL1012S – LonWorks Inputs • 1 universal input • 0 digital inputs Outputs • 1 analog output • 2 digital outputs PVL0000AS – LonWorks Inputs • 0 universal inputs • 0 digital inputs Outputs • 0 analog outputs • 0 digital outputs PVL4024NS – LonWorks Inputs • 4 universal inputs • 0 digital inputs Outputs • 2 analog outputs • 4 digital outputs PUL4024S – LonWorks Inputs • 4 universal inputs • 0 digital inputs Outputs • 2 analog outputs • 4 digital outputs PVL4022AS – LonWorks Inputs • 4 universal inputs • 0 digital inputs Outputs • 2 analog outputs • 2 digital outputs PVL6438NS – LonWorks Inputs • 6 universal inputs • 4 digital inputs Outputs • 3 analog outputs • 8 digital outputs PUL6438S – LonWorks Inputs • 6 universal inputs • 4 digital inputs Outputs • 3 analog outputs • 8 digital outputs PVL6436AS – LonWorks Inputs • 6 universal inputs • 4 digital inputs Outputs • 3 analog outputs • 6 digital outputs PVB6438NS – BACnet Inputs • 6 universal inputs • 4 digital inputs Outputs • 3 analog outputs • 8 digital outputs PUB6438S – BACnet Inputs • 6 universal inputs • 4 digital inputs Outputs • 3 analog outputs • 8 digital outputs PVB6436AS – BACnet Inputs • 6 universal inputs • 4 digital inputs Outputs • 3 analog outputs • 6 digital outputs New Licensing Scheme • The Spyder Tool checks the license for features - As of Spyder Tool 4.X and later • There are two Spyder features - SpyderProgrammable for the Lon Spyders - SpyderBACnetProgrammable for the BACnet Spyders • Spyder features are only available on WEBS branded JACE’s and Supervisor Engineering Demo’s - W-ENG-AX-DEMO 11 Spyder-ILC • The Spyder-ILC is an individually licensed controller - Spyder-ILC controllers will accept a download from the Spyder Tool regardless of the brand of workstation/JACE - In other words, features within the license are ignored • The Spyder-ILC’s have the same OS number with an “-ILC” suffix - Example: PUL6438S-ILC, PVB6436AS-ILC, PVL4022AS-ILC • 20% adder per Spyder-ILC for licensing fee - No one else in the industry offers a programmable controller that can be programmed on ANY AX front end! • Like all Spyders, the ILC can only be sold to Honeywell ACS or ACI contractors 12 Scenario – WEBS Brand JACE 13 WEBS Brand Workbench WEBS Brand JACE Spyder Feature Honeywell Spyder 3rd Party Brand Workbench WEBS Brand JACE Spyder Feature Honeywell Spyder Scenario – WEBS OPEN Brand JACE ANY Brand Workbench WEBS “OPEN” Brand JACE Spyder Feature Honeywell Spyder Not Typical ANY Brand Workbench 14 WEBS “OPEN” Brand JACE Spyder Feature Honeywell Spyder-ILC Scenario – 3rd Party JACE ANY Brand Workbench ANY Brand Workbench 15 3rd Party Brand JACE 3rd Party Brand JACE Honeywell Spyder Honeywell Spyder-ILC Scenario – No JACE WEBS Brand Engineering Demo Supervisor Honeywell Spyder 3rd Party Brand Workbench Honeywell Spyder ANY Brand Workbench 16 Honeywell Spyder-ILC Scenario – Existing Support • Existing WEBS job needs to be expanded - 1. Keep existing workbench and tool; add Spyders as needed License change doesn’t affect a job already installed - 2. Get new license with correct Spyder Features If using 403 or 545, the appropriate feature is needed • Existing job with 3rd party JACE and Spyders, needs to be expanded - 1. Keep existing workbench and tool; add Spyders as needed License change doesn’t affect a job already installed - 2. Upgrade to latest Spyder Tool and use ILC to expand Previous Spyders must be brought in as 3rd party devices and you won’t be able to download to them 17 Freely Programmable • Just determine your requirements, then program Spyder to control it all 18 Spyder Palette 19 Application Library 21 Program Simulator and Debug Mode 23 Macros 25 Adaptive Integral Algorithm • Honeywell’s Adaptive Integral Algorithm (AIA) Control is the most accurate control available for space control applications 27 Model Numbers P VL6436 AS S – Sylk Bus P – Programmable A – With Actuator N – Without Actuator U – Unitary V – VAV L – LON B – BACnet Number of available Digital Outputs Number of Universal Inputs Number of Analog Outputs Number of Digital Inputs 28 Spyder Lon Specific Details • Free Topology Transceiver (FTT) - High-speed 78 kilobit communications network • Function Blocks - 200 Function Blocks max per controller • Lon Network Variables - 240 total NV’s per controller 20 Mandatory NVs 7 Fixed NVs 213 User Defined NVs • Support for up to 120 controllers per LonWorks channel 29 Spyder BACnet Specific Details • BACnet MS/TP LAN communication network - Capable of baud rates between 9.6 and 115.2 kilobits • BTL B-ASC - BACnet Testing Laboratories B-ASC (BACnet Application Specific Controller) - Certification Testing in process • BACnet PICS (Protocol Implementation Conformance Statement) - Refer to the PICS for information on: BIBBs – BACnet Interoperability Building Blocks BACnet Device Objects • Support for up to 30 controllers per BACnet MS/TP LAN Segment 30 Spyder FAQ’s • Should I use a Spyder if the current XL10 meets the sequence or requirements? Depends on application • Do you want to order the Spyder with Actuator when you need to separate the actuator and controller? NO - What Actuators are recommended for use with the Spyder VAV controllers without Actuators? ML6161, ML6174, MN6105 31 Architecture Internet WEB Station WEB Browser WEB Browser HTTP, XML, BACnet, SNMP, oBIX WEB-600 WEB-600 Spyder Lon 34 pt I/O Video Monitoring and Control Spyder BACnet SEC-H-600 RS-485 RS-485 Spyder Lon Spyder BACnet Spyder Lon Intrusion Keypad/Display T7350 CVAHU UV Spyder BACnet Lighting Control 32 Security Elevator Control Access Control Time and Attendance Sylk™ Bus • Sylk is a two wire, polarity insensitive bus that provides both 18 Vdc power and communications between a Sylk-enabled sensor and a Sylk-enabled controller • Devices - Zio LCD Wall Module TR70 TR70-H • Future - TR20 Series - Sylk IO Addressing the combined needs of the Building Automation and Field Device team 34 TR20 Series Wireless Overview • Point to Point - Direct replacement for a wired sensor - Can be used with Spyder, XL10, T7350 thermostats, SuitePRO - Not compatible with Commercial VisionPRO & CommercialPRO thermostats Receiver • Two Sensor options - With temperature only TR21-WK kit or TR21-WS sensor only - With temperature, setpoint knob, and override button TR23-WK kit or TR23-WS sensor only • On board signal strength indicator - No need for diagnostic tool • Beta in progress – Thank You! Wireless sensor Replace a wired sensor, without the wires! 35 Noteworthy Installations • Prairie View School District, Saskatchewan 36 Noteworthy Installations • Target Field (Twins Stadium) - Minneapolis 37 Noteworthy Installations • ACS Headquarters – Golden Valley 38 Noteworthy Installations • Adelphia Labs, New Jersey 39 Noteworthy Installations • Vectura Pharmaceutical, United Kingdom 40 Noteworthy Installations • Claridges Hotel, Delhi 41 Spyder Tool Demonstration 42 www.honeywell.com