AMA-61850-FiT4HANA Designed for Big Data Cooperation between AMA-SYSTEMS, Fichtner IT and SAP Content AMA-Systems GmbH The IEC 61850 Standard AMA-61850-FiT4HANA AMA-SYSTEMS GMBH D 75179 Pforzheim August 2014 IEC 61850 Implementation in Big Data Page 2 AMA-SYSTEMS GMBH • • • • AMA-SYSTEMS founded in 1976 in Germany as an Engineering Company and is focused on the Automation – Information – Communication area. AMA-SYSTEMS offers high quality standard HW and SW Products and also Engineering for the Optimization of ENERGY & UTILITY in Europe. AMA is called “The Standard Based Integration Specialist” for IEC 61850 and IEC 60870-6/ICCP/TASE.2. AMA is o Value added Reseller (VAR) of SISCO Inc. (US) for Europe. o Partner of OSIsoft, IBM and SAP. AMA-SYSTEMS GMBH D 75179 Pforzheim August 2014 IEC 61850 Implementation in Big Data Page 3 FICHTNER GROUP Established in 1922, the Fichtner Group is today Germany’s biggest independent engineering and consultancy enterprise Approximately 2,000 employees worldwide – 500 in Stuttgart Home Office Total turnover of €260 million in 2012 Capital investment volume now under planning in the home office: €106 billion – of which some €26 billion is in renewable energies FICHTNER IT CONSULTING Competence Center for IT Consultancy and Solutions Project focus on GIS and portal solutions, system integration, maintenance, asset management and billing Source: Fichtner Strong SAP competence through our subsidiaries P&S Consulting GmbH and SPE Unternehmensberatung GmbH (Validated Expertise for Utilities) AMA-SYSTEMS GMBH D 75179 Pforzheim August 2014 IEC 61850 Implementation in Big Data Page 4 AMA-SYSTEMS Products Gateways o AMA-ICCP-TCP-GW-1L. Server Simulator for IEC 61850 o AMA-61850-ServerSim-G Test Procedures for Conformance Testing o AMA-61850-Test-KiT IEC 61850 Client Interface for Big Data o AMA-61850-FiT4HANA Trainings, Workshops, Technical Support for IEC 61850 and ICCP AMA-SYSTEMS GMBH D 75179 Pforzheim August 2014 IEC 61850 Implementation in Big Data Page 5 IEC 61850 Standard IEC 61850 Client Server Architecture IEC 61850 Server IEC 61850 is an Interoperability Standard for Communication between IEDs and Software Systems: Hardware independent, bidirectional, Ethernet TCP/IP based. IEC 61850 Server IEC 61850 Layer Model IEC 61850 Server Communication Network ( Ethernet, TCP/IP ) Information Model ( IED Description ) Information Exchange ( get, set, log, …) Communication Profiles ( Ethernet, TCP/IP) Configuration Language IEC 61850 Server Messages IEC 61850 Client Source: Fichtner; AMA-SYSTEMS AMA-SYSTEMS GMBH D 75179 Pforzheim August 2014 IEC 61850 Implementation in Big Data Page 6 Benefits in Substations and Bays Using IEC 61850 standard in System Control creates very significant benefits: • Above all reducing TCO. • Shorter time of Implementation. • Independence from Hardware and Software Suppliers. Source: SISCO AMA-SYSTEMS GMBH D 75179 Pforzheim August 2014 IEC 61850 Implementation in Big Data Page 7 IEC 61850 based Integration IEC 61850 based Integration will also play a major role in the future for decentralized Energy Systems such as Smart Grid Environments or Smart Meters. Decentralized PV Generation Decentralized Wind Generation IEC 61850-7-420 Hydropower Plant IEC 62445-2 (IEC 61850-90-2) IEC 61400-25 Centralized Generation IEC 62445-2 (IEC 61850-90-2) IEC 62445-2 (IEC 61850-90-2) IEC 61850-7-410 Grid Control Center ICCP/TASE.2/IEC 60870-6 Stations IEC 61850 IEC 61850-90-1 AMA-SYSTEMS GMBH D 75179 Pforzheim August 2014 IEC 61850 IEC 61850 Implementation in Big Data Page 8 Benefits from Interoperability • • • • Fewer outages, due to better system monitoring, analysis and management. Faster service restoration following an outage. Better information flow leads to higher system resistance against attacks. Better resource adequacy because interoperability enables better integration of diverse supply. AMA-SYSTEMS GMBH D 75179 Pforzheim August 2014 IEC 61850 Implementation in Big Data Page 9 IEC 61850 and Smart Grid Applications Architecture View: IEC 61850 Series Standards in many Roles within the Smart Grid. Source: IEC: http://smartgridstandardsmap.com/ AMA-SYSTEMS GMBH D 75179 Pforzheim August 2014 IEC 61850 Implementation in Big Data Page 10 HANA/SAP – a “Big Data” Realtime Data Platform The implementation of IEC 61850 as a generic module in SAP HANA is a basic component of the new Fichtner Energy Software Suite on HANA Fichtner solution Time Series Management Source: SAP, Fichtner AMA-SYSTEMS GMBH D 75179 Pforzheim August 2014 IEC 61850 Implementation in Big Data Page 11 IEC 61850 Standard for Big Data IEC 61850 module as third party component of SAP HANA time series • data platform The AMA-SYSTEMS implementation of IEC 61850 as a generic module in SAP HANA is a basic component of the new Fichtner Energy Software Suite on SAP HANA. Source: AMA-SYSTEMS IEC 61850 Module SAP, Fichtner, AMA AMA-SYSTEMS GMBH D 75179 Pforzheim August 2014 IEC 61850 Implementation in Big Data Page 12 IEC 61850 Interface SAP HANA Reports Data Change, Periodic Read Response AMA-SYSTEMS IEC 61850 Client Interface Read Request Provides direct access to data of IEC 61850 Server devices (IEDs) without the need for an additional Gateway protocol like OPC, ... Direct access to IEC 61850 avoids the disadvantages of such Gateway protocols as additional mapping effort, risk of mapping errors, communication bottleneck, ... Ethernet, TCP/IP AMA-SYSTEMS GMBH D 75179 Pforzheim August 2014 other IEC 61850 Devices IEC 61850 Implementation in Big Data Page 13 Big Data Analytics of IEC 61850 Standard The AMA-SYSTEMS IEC 61850 Module in HANA/SAP will enable very fast Sensor Data input into the Time Series and RDP platform and the subsequent use in value- added Applications. Fichtner BGI Analytics SAP HANA Realtime Data Platform SCADA Data Time Series Analysis Inspection Data Wind Failure History Lightning Asset Master Data Satellite Data Time Series Core Services Analysis, Visualization, Editing KPI calculation and comparison Financial Data AMA-SYSTEMS IEC 61850 Client SAP Backend IEC 61850 Server EAM FI/CO Maintenance Analysis , drill down to sensor data and work orders PS Non SAP Systems Failure data Construction data Source: Fichtner IT Other Web Services AMA-SYSTEMS GMBH D 75179 Pforzheim August 2014 FMEA Analysis Condition Monitorimg IEC 61850 Implementation in Big Data Page 14 Thank you for your attention! AMA-SYSTEMS GMBH D 75179 Pforzheim August 2014 IEC 61850 Implementation in Big Data Page 15