AN INTRODUCTION TO THE CIRRUS PRO RANGE OF FIRE DETECTION DETECTORS Presented by Chris Malone Export Sales Manager Cirrus Pro Series Aspirating Fire Detectors Contents • Different Technologies • Understanding Cloud Chamber Detectors • Cirrus Pro Series Detector Range • Applications • Design Concepts • Cirrus Pro Sampling Pipe • Detector Configurations The worlds most versatile fire detector Cirrus Pro Series Aspirating Fire Detectors Aspirating Smoke/Fire Detectors Main Manufacturers Vesda - Laser based ‘Optical’ smoke detector Stratos - Laser based ‘Optical’ smoke detector ICAM – Laser Based ‘Optical’ smoke detector Wagner – ‘Optical’ based smoke detector Cirrus Pro – ‘Cloud Chamber’ fire detector The worlds most versatile fire detector Cirrus Pro Series ‘Cloud Chamber’ Aspirating Fire Detectors How do they work? What do they detect? Cirrus Pro Series Aspirating Fire Detectors Understanding ‘Cloud Chamber’ detectors How does a fire start? ‘Ignition Point’ T e m p e r a t u r e Visible smoke (detected by ‘optical’ detection methods) Massive generation of INVISIBLE sub micron particles ‘Thermal Particulate Point’ Every combustible material has a NORMAL temperature range The worlds most versatile fire detector Cirrus Pro Series Aspirating Fire Detectors Understanding ‘Cloud Chamber’ detectors What are these sub-micron particles? • • • • • These are sub micron carbon particles They are 0.0025mirco-meters in size They exist in normal air all the time We breath them in continuously In normal conditions only combustion generates the massive quantities that the the ‘Cloud Chamber’ can interpret as a fire condition The worlds most versatile fire detector Understanding ‘Cloud Chamber’ detectors Sub-micron particle detection? 0.0025 micron particles ? • In an air space 1 cm3 there are approximately 15,000 - 0.0025 submicron particles in normal conditions i.e. (no overheat condition or fire) • In the same size air space (1 cm3 ) when there is an overheat or fire condition approximately 10,000,000,000 0.0025 sub-micron particles are produced The ‘Cloud Chamber’ detects this increase in particle generation The problem is that these particles are INVISIBLE Understanding ‘Cloud Chamber’ detectors Sub-micron particle detection? Invisible 0.0025 micron particles ? Cloud Chamber From invisible particles that cannot be measured Airflow containing ALL particles passes through the ‘Cloud Chamber’ ‘Cloud Chamber’ process condenses water droplets on to all particles The enlarged particles form a cloud and the ‘Cloud Chamber’ measures the resultant cloud density To BIGGER visible particles that can be measured Understanding ‘Cloud Chamber’ detectors Why are Cloud Chambers immune to false alarms from dust ? 0.0025 sub micron combustion particles 2 - 10 micron dust/smoke particles Cloud Chamber Introduce dust into the cloud chamber Condensate water droplets onto the sample Dust particles cannot provide enough cloud density to cause an alarm from the cloud chamber Cirrus Pro Series Aspirating Fire Detector Product Range Cirrus Pro 100 • • • • • • • • • • • • Unique ‘cloud chamber’ detection principle Up to 100mtrs - 25mm o/d sampling pipe Single sampling pipe port, single exhaust port ‘Pre-Alarm’, ‘Fire 1’, ‘Fire 2’ & ‘Fire 3’ indications ‘Power Healthy’ and ‘Common Fault’ indicators Local Buzzer, Silence & Reset buttons Vast sensitivity range (incipient - heavy polluted) ‘Fixed’ or ‘Variable’ sensitivity options Detector text, Alarm text & Pipe text 3 Programmable ‘time zones’ per day ‘Transport Time’ logging feature Option for Repeat Display & Network Configuration Cirrus Pro 200 • • • • • • • • • • • • Unique ‘cloud chamber’ detection principle Up to 200mtrs - 25mm o/d sampling pipe Four sampling pipe inlet ports, single exhaust port ‘Pre-Alarm’, ‘Fire 1’, ‘Fire 2’ & ‘Fire 3’ indications ‘Power Healthy’ and ‘Common Fault’ indicators Local Buzzer, Silence & Reset buttons Vast sensitivity range (incipient - heavy polluted) ‘Fixed’ or ‘Variable’ sensitivity options Detector text, Alarm text & Pipe text 3 Programmable ‘time zones’ per day ‘Transport Time’ logging feature Option for Repeat Display & Network Configuration Cirrus Pro 200D • • • • • • • • • • • • • Unique ‘cloud chamber’ detection principle Multifunction Display & Programmer Up to 200mtrs - 25mm o/d sampling pipe Four sampling pipe inlet ports, single exhaust port ‘Pre-Alarm’, ‘Fire 1’, ‘Fire 2’ & ‘Fire 3’ indications ‘Power Healthy’ and ‘Common Fault’ indicators Local Buzzer, Silence & Reset buttons Vast sensitivity range (incipient - heavy polluted) ‘Fixed’ or ‘Variable’ sensitivity options Detector text, Alarm text & Pipe text 3 Programmable ‘time zones’ per day ‘Transport Time’ logging feature Option for Repeat Display & Network Configuration Cirrus Pro 200DSC • • • • • • • • • • • • • Unique ‘cloud chamber’ detection principle Multifunction Display & Programmer Up to 200mtrs - 25mm o/d sampling pipe Four sampling pipe inlet ports, single exhaust port ‘Pre-Alarm’, ‘Fire 1’, ‘Fire 2’ & ‘Fire 3’ indications PER PIPE ‘Power Healthy’ and ‘Common Fault’ indicators Local Buzzer, Silence & Reset buttons Vast sensitivity range (incipient - heavy polluted) ‘Fixed’ or ‘Variable’ sensitivity options Detector text, Alarm text & Pipe text 3 Programmable ‘time zones’ per day ‘Transport Time’ logging feature Option for Repeat Display & Network Configuration Cirrus Pro 200+ • Unique ‘cloud chamber’ detection principle • In excess of 200mtrs - 25mm o/d sampling pipe (subject to pipe calculation program verification) • Four sampling pipe inlet ports, single exhaust port • ‘Pre-Alarm’, ‘Fire 1’, ‘Fire 2’ & ‘Fire 3’ indications • ‘Power Healthy’ and ‘Common Fault’ indicators • Local Buzzer, Silence & Reset buttons • Vast sensitivity range (incipient - heavy polluted) • ‘Fixed’ or ‘Variable’ sensitivity options • Detector text, Alarm text & Pipe text • 3 Programmable ‘time zones’ per day • ‘Transport Time’ logging feature • Option for Repeat Display & Network Configuration Cirrus Pro 200D+ • Unique ‘cloud chamber’ detection principle • Multifunction Display & Programmer • In excess of 200mtrs - 25mm o/d sampling pipe (subject to pipe calculation program verification) • Four sampling pipe inlet ports, single exhaust port • ‘Pre-Alarm’, ‘Fire 1’, ‘Fire 2’ & ‘Fire 3’ indications • ‘Power Healthy’ and ‘Common Fault’ indicators • Local Buzzer, Silence & Reset buttons • Vast sensitivity range (incipient - heavy polluted) • ‘Fixed’ or ‘Variable’ sensitivity options • Detector text, Alarm text & Pipe text • 3 Programmable ‘time zones’ per day • ‘Transport Time’ logging feature • Option for Repeat Display & Network Configuration Cirrus Pro 200DSC+ • Unique ‘cloud chamber’ detection principle • Multifunction Display & Programmer • In excess of 200mtrs - 25mm o/d sampling pipe (subject to pipe calculation program verification) • Four sampling pipe inlet ports, single exhaust pipe port • ‘Pre-Alarm’, ‘Fire 1’, ‘Fire 2’ & ‘Fire 3’ indications PER PIPE • ‘Power Healthy’ and ‘Common Fault’ indicators • Local Buzzer, Silence & Reset buttons • Vast sensitivity range (incipient - heavy polluted) • ‘Fixed’ or ‘Variable’ sensitivity options • Detector text, Alarm text & Pipe text • 3 Programmable ‘time zones’ per day • ‘Transport Time’ logging feature • Option for Repeat Display & Network Configuration Cirrus Pro RDP (Remote Display Programmer) • • • • • • • • • • Multifunction Display & Programmer May be assigned to individual Cirrus Pro detector May be assigned to a network of Cirrus Pro detectors ‘Network Status’ indication ‘Power Healthy’ and ‘Common Fault’ indicators Global Network - Silence & Reset buttons Local Buzzer with mute facility Remote access/control to any networked Cirrus Pro detector Can provide detector text, alarm text & pipe text per device Can provide ‘Real Time’ and ‘Historic’ graph data per device Categories • High Sensitive Applications • General Sensitivity Applications • Harsh Environment Applications • Special Risk Applications • Sensitive Applications High Sensitive applications include…. Data Storage Control Rooms Computer Rooms General Sensitive applications include Roof Voids Warehousing Atriums Harsh Environment applications include Cold Storage Specialist Production Food Production Special Risk applications include Cabinet Protection Rotunda Areas Test Rooms 16 Sensitive Applications include Historic Buildings High Ceilings Ornate Ceilings The worlds most versatile fire detector Cirrus Pro Series Aspirating Fire Detectors • CIRRUS PRO TCP-IP CONNECTIONS Cirrus Pro Series Aspirating Fire Detectors Köszönöm THE END The worlds most versatile fire detector