Cirrus Pro Series Aspirating Fire Detector

advertisement
AN INTRODUCTION TO THE
CIRRUS PRO RANGE
OF FIRE DETECTION DETECTORS
Presented by
Chris Malone
Export Sales Manager
Cirrus Pro Series Aspirating Fire Detectors
Contents
• Different Technologies
• Understanding Cloud Chamber Detectors
• Cirrus Pro Series Detector Range
• Applications
• Design Concepts
• Cirrus Pro Sampling Pipe
• Detector Configurations
The worlds most versatile fire detector
Cirrus Pro Series Aspirating Fire Detectors
Aspirating Smoke/Fire Detectors
Main Manufacturers
Vesda - Laser based ‘Optical’ smoke detector
Stratos - Laser based ‘Optical’ smoke detector
ICAM – Laser Based ‘Optical’ smoke detector
Wagner – ‘Optical’ based smoke detector
Cirrus Pro – ‘Cloud Chamber’ fire detector
The worlds most versatile fire detector
Cirrus Pro Series ‘Cloud Chamber’
Aspirating Fire Detectors
How do they work?
What do they detect?
Cirrus Pro Series Aspirating Fire Detectors
Understanding ‘Cloud Chamber’ detectors
How does a fire start?
‘Ignition Point’
T
e
m
p
e
r
a
t
u
r
e
Visible smoke (detected by ‘optical’ detection methods)
Massive generation of INVISIBLE
sub micron particles
‘Thermal Particulate Point’
Every combustible material has a
NORMAL temperature range
The worlds most versatile fire detector
Cirrus Pro Series Aspirating Fire Detectors
Understanding ‘Cloud Chamber’ detectors
What are these sub-micron particles?
•
•
•
•
•
These are sub micron carbon particles
They are 0.0025mirco-meters in size
They exist in normal air all the time
We breath them in continuously
In normal conditions only combustion
generates the massive quantities that
the the ‘Cloud Chamber’ can interpret
as a fire condition
The worlds most versatile fire detector
Understanding ‘Cloud Chamber’ detectors
Sub-micron particle detection?
0.0025 micron particles ?
• In an air space 1 cm3 there are
approximately 15,000 - 0.0025 submicron particles in normal conditions
i.e. (no overheat condition or fire)
• In the same size air space (1 cm3 ) when
there is an overheat or fire condition
approximately 10,000,000,000
0.0025 sub-micron particles are produced
The ‘Cloud Chamber’ detects this increase in particle generation
The problem is that these particles are
INVISIBLE
Understanding ‘Cloud Chamber’ detectors
Sub-micron particle detection?
Invisible 0.0025 micron
particles ?
Cloud Chamber
From
invisible
particles that
cannot be
measured
Airflow containing ALL particles
passes through the ‘Cloud Chamber’
‘Cloud Chamber’ process condenses
water droplets on to all particles
The enlarged particles form a cloud and the
‘Cloud Chamber’ measures the resultant cloud density
To BIGGER
visible
particles that
can be
measured
Understanding ‘Cloud Chamber’ detectors
Why are Cloud Chambers immune to false alarms
from dust ?
0.0025 sub micron
combustion particles
2 - 10 micron
dust/smoke particles
Cloud Chamber
Introduce dust into the cloud chamber
Condensate water droplets onto the sample
Dust particles cannot provide enough cloud density
to cause an alarm from the cloud chamber
Cirrus Pro Series Aspirating Fire Detector
Product Range
Cirrus Pro 100
•
•
•
•
•
•
•
•
•
•
•
•
Unique ‘cloud chamber’ detection principle
Up to 100mtrs - 25mm o/d sampling pipe
Single sampling pipe port, single exhaust port
‘Pre-Alarm’, ‘Fire 1’, ‘Fire 2’ & ‘Fire 3’ indications
‘Power Healthy’ and ‘Common Fault’ indicators
Local Buzzer, Silence & Reset buttons
Vast sensitivity range (incipient - heavy polluted)
‘Fixed’ or ‘Variable’ sensitivity options
Detector text, Alarm text & Pipe text
3 Programmable ‘time zones’ per day
‘Transport Time’ logging feature
Option for Repeat Display & Network Configuration
Cirrus Pro 200
•
•
•
•
•
•
•
•
•
•
•
•
Unique ‘cloud chamber’ detection principle
Up to 200mtrs - 25mm o/d sampling pipe
Four sampling pipe inlet ports, single exhaust port
‘Pre-Alarm’, ‘Fire 1’, ‘Fire 2’ & ‘Fire 3’ indications
‘Power Healthy’ and ‘Common Fault’ indicators
Local Buzzer, Silence & Reset buttons
Vast sensitivity range (incipient - heavy polluted)
‘Fixed’ or ‘Variable’ sensitivity options
Detector text, Alarm text & Pipe text
3 Programmable ‘time zones’ per day
‘Transport Time’ logging feature
Option for Repeat Display & Network Configuration
Cirrus Pro 200D
•
•
•
•
•
•
•
•
•
•
•
•
•
Unique ‘cloud chamber’ detection principle
Multifunction Display & Programmer
Up to 200mtrs - 25mm o/d sampling pipe
Four sampling pipe inlet ports, single exhaust port
‘Pre-Alarm’, ‘Fire 1’, ‘Fire 2’ & ‘Fire 3’ indications
‘Power Healthy’ and ‘Common Fault’ indicators
Local Buzzer, Silence & Reset buttons
Vast sensitivity range (incipient - heavy polluted)
‘Fixed’ or ‘Variable’ sensitivity options
Detector text, Alarm text & Pipe text
3 Programmable ‘time zones’ per day
‘Transport Time’ logging feature
Option for Repeat Display & Network Configuration
Cirrus Pro 200DSC
•
•
•
•
•
•
•
•
•
•
•
•
•
Unique ‘cloud chamber’ detection principle
Multifunction Display & Programmer
Up to 200mtrs - 25mm o/d sampling pipe
Four sampling pipe inlet ports, single exhaust port
‘Pre-Alarm’, ‘Fire 1’, ‘Fire 2’ & ‘Fire 3’ indications PER PIPE
‘Power Healthy’ and ‘Common Fault’ indicators
Local Buzzer, Silence & Reset buttons
Vast sensitivity range (incipient - heavy polluted)
‘Fixed’ or ‘Variable’ sensitivity options
Detector text, Alarm text & Pipe text
3 Programmable ‘time zones’ per day
‘Transport Time’ logging feature
Option for Repeat Display & Network Configuration
Cirrus Pro 200+
• Unique ‘cloud chamber’ detection principle
• In excess of 200mtrs - 25mm o/d sampling pipe
(subject to pipe calculation program verification)
• Four sampling pipe inlet ports, single exhaust port
• ‘Pre-Alarm’, ‘Fire 1’, ‘Fire 2’ & ‘Fire 3’ indications
• ‘Power Healthy’ and ‘Common Fault’ indicators
• Local Buzzer, Silence & Reset buttons
• Vast sensitivity range (incipient - heavy polluted)
• ‘Fixed’ or ‘Variable’ sensitivity options
• Detector text, Alarm text & Pipe text
• 3 Programmable ‘time zones’ per day
• ‘Transport Time’ logging feature
• Option for Repeat Display & Network Configuration
Cirrus Pro 200D+
• Unique ‘cloud chamber’ detection principle
• Multifunction Display & Programmer
• In excess of 200mtrs - 25mm o/d sampling pipe
(subject to pipe calculation program verification)
• Four sampling pipe inlet ports, single exhaust port
• ‘Pre-Alarm’, ‘Fire 1’, ‘Fire 2’ & ‘Fire 3’ indications
• ‘Power Healthy’ and ‘Common Fault’ indicators
• Local Buzzer, Silence & Reset buttons
• Vast sensitivity range (incipient - heavy polluted)
• ‘Fixed’ or ‘Variable’ sensitivity options
• Detector text, Alarm text & Pipe text
• 3 Programmable ‘time zones’ per day
• ‘Transport Time’ logging feature
• Option for Repeat Display & Network Configuration
Cirrus Pro 200DSC+
• Unique ‘cloud chamber’ detection principle
• Multifunction Display & Programmer
• In excess of 200mtrs - 25mm o/d sampling pipe
(subject to pipe calculation program verification)
• Four sampling pipe inlet ports, single exhaust pipe port
• ‘Pre-Alarm’, ‘Fire 1’, ‘Fire 2’ & ‘Fire 3’ indications PER PIPE
• ‘Power Healthy’ and ‘Common Fault’ indicators
• Local Buzzer, Silence & Reset buttons
• Vast sensitivity range (incipient - heavy polluted)
• ‘Fixed’ or ‘Variable’ sensitivity options
• Detector text, Alarm text & Pipe text
• 3 Programmable ‘time zones’ per day
• ‘Transport Time’ logging feature
• Option for Repeat Display & Network Configuration
Cirrus Pro RDP
(Remote Display Programmer)
•
•
•
•
•
•
•
•
•
•
Multifunction Display & Programmer
May be assigned to individual Cirrus Pro detector
May be assigned to a network of Cirrus Pro detectors
‘Network Status’ indication
‘Power Healthy’ and ‘Common Fault’ indicators
Global Network - Silence & Reset buttons
Local Buzzer with mute facility
Remote access/control to any networked Cirrus Pro detector
Can provide detector text, alarm text & pipe text per device
Can provide ‘Real Time’ and ‘Historic’ graph data per device
Categories
• High Sensitive Applications
• General Sensitivity Applications
• Harsh Environment Applications
• Special Risk Applications
• Sensitive Applications
High Sensitive applications include….
Data Storage
Control Rooms
Computer Rooms
General Sensitive applications include
Roof Voids
Warehousing
Atriums
Harsh Environment applications include
Cold Storage
Specialist Production
Food Production
Special Risk applications include
Cabinet Protection
Rotunda Areas
Test Rooms
16
Sensitive Applications include
Historic Buildings
High Ceilings
Ornate Ceilings
The worlds most versatile fire detector
Cirrus Pro Series Aspirating Fire Detectors
• CIRRUS PRO TCP-IP CONNECTIONS
Cirrus Pro Series Aspirating Fire Detectors
Köszönöm
THE END
The worlds most versatile fire detector
Download