K Series Packaged Units & Commercial Split Systems- 2011 Overview • Commercial Market Strategy – Replacement Market Focus • K Series Products – KGA, KCA, KHA • T Series Large Split Systems (6-20 ton) – TSA, TPA, TAA • Small Split Systems (3-5 ton) – 4SCU13, 4SHP13, ACBX32 2010 Commercial Regional Distribution Center (CRDC) 7 US & 2 Canadian CRDC’s for quick product access C200 Calgary CRDC Brampton CRDC 2010 Commercial Regional Distribution Center (CRDC) • In stock for quick delivery or pickup • Ship direct to job site • Great for replacement • Wide range of field installed accessories • Available factory options Regional Distribution Centers Manufacturing Quality Packaged Unit Overview 2-25 Ton Overview • Tonnages Gas / Electric (KGA) = 2, 2.5, 3, 4, 5, 6, 7.5, 8.5, 10, 12.5, 15, 17.5, 20 & 25 Electric / Electric (KCA) = 2, 2.5, 3, 4, 5, 6, 7.5, 8.5, 10, 12.5, 15, 17.5, 20 & 25 Heat Pumps (KHA) = 2, 2.5, 3, 4, 5, 6, 7.5, 8.5, 10, 12.5, 15, 20 2-25 Ton Overview • K Series replaces T Series Products – K Series backward compatible to T Series – K Series B Box units require a return air adaptor plate • Field & factory installed accessories available – Lead time for some factory installed CTO accessories • Variety of roof curb styles and types available • ASHRAE 90.1 Complaint – Products meet 2010 efficiency requirements 2-25 Ton Overview • Serviceability Features – Common Parts – Plastic Drain Pans – Color coded & continuously marked wiring – Fork slots on 3 sides with rigging holes at the corners – Large access panels – Thermal expansion valve with removable element Large Access Panels Fork Slots Unit Rigging Box Size Overview • A Box – Gas Electric & Electric Cooling – Heat Pump • A+ Box 2-6 ton 2-5 ton – “Stretched” A Box • 8” taller, 13” longer, same depth – Gas Electric 7.5 ton • Single Circuit- 1 compressor • Heating Capacity up to 150,000 BTUH – Heat Pump • Single Circuit- 1 compressor 6 ton Box Size Overview • B Box (7.5-12.5 ton) • C Box (15-25 ton) – Dual circuit 7.5 ton – Multiple circuits capacities – 15 ton units- 2 – Gas Electric, Electric compressors Cooling & Heat Pump – 17.5, 20, 25 ton units3 compressors – Gas Electric & Electric Cooling (15-25 ton) 15 ton unit – Heat Pump (15-20 ton) with 2 compressors C Box Layout Economizer Dampers (optional) Condenser Fans Indoor Coil Belt Drive Blower Motor Compressors Gas Heat Section Government Regulations Accessories- Field Installed Accessories- Field Installed • Coil Protection – Coil guards – Hail guards • Controls – Smoke detectors • Cooling Accessories – Compressor crankcase heaters – Low ambient kits • Condensate Traps – Copper – PVC Accessories- Field Installed • Ceiling Diffusers – Step down – Flush – Ceiling diffuser transitions used with roof curb Accessories- Field Installed • Electrical accessories – Disconnect kits (Factory Also) – GFI service outlet • Horizontal Conversion – Horizontal discharge kit Accessories- Field Installed • Gas Heating Accessories – Bottom gas piping kit – Combustion air intake & vertical vent extension kits – Low temperature vestibule heater – LP kits Accessories- Field Installed • Indoor Air Quality – UVC germicidal lamps – High Efficiency MERV 8 & 13 filters on certain models – CO2 Sensors- Wall or plenum mount Accessories- Field Installed • Outdoor Air Options – Outdoor air dampers(Factory Also) standard & motorized – Introduce up to 25% outdoor air- required by local codes – Power exhaust fans Accessories- Factory Installed Accessories- Factory Installed • Build to Order on some factory installed options – 10-12 week lead time • Corrosion Protection – evaporator coil, condenser coil or both • Hinged Access Panels – economizer, filter, compressor, controls, heating, blower sections Accessories- Factory Installed • Stainless Steel Heat Exchanger – 15 year warranty • Low & High Static Blower Drives – Low static drives ideal for warehouses – High static ideal for add on cooling applications with existing ductwork • Gas Heat Options – Medium and high heat capability • Voltage Options – 208/230, 3 ph, 460, 3 ph or 575, 3ph Accessories- Factory & Field Installed • Economizers – Provide outdoor air for cooling instead of mechanical cooling- saves money on electrical consumption- can introduce up to 100% outdoor air – Why use economizers? • Reduce the need for mechanical cooling- save $ on electrical consumption • Some buildings need cooling all year long- people add heat as well as computers & assembly processes – ASHRAE Standards (90.1) • Require economizers and/or a certain percentage of outdoor introduction in commercial buildings in some parts of the country Accessories- Factory & Field Installed Accessories- Factory & Field Installed Accessories- Roof Curbs & Curb Adaptors Accessories- Roof Curbs & Adaptors • Roof curbs – Cliplock (8, 14, 18, 24”) – Hinged (8, 18, 24”) – Standard (14, 24”) • Roof curb adaptors needed for replacement applications – Allied Commercial unit replaces a competitive unit – Existing roof curb remains on the roof • Roof curb manufacturers can provide pricing and lead times – Old unit & replacement unit model numbers needed Accessories- Roof Curbs & Adaptors Commercial Sales Tools Commercial Sales Tools • Product Information & Learning Tools – 1) Website • http://www.allied-commercial.com – 2) Commercial Catalogs • Spec Sheets, Sales Brochure – 3) E-Learning CD • Audio & video tutorial of K Series product line • Links to installation instructions & spec sheets Commercial Sales Tools www.allied-commercial.com T Series Large Split Systems T Series Split Systems TSA – Condensing Units TPA – Heat Pumps TSA 072- 6 ton TSA090- 7.5 ton TSA 120S- 10 ton TSA120D- 10 ton TSA150- 12.5 ton TPA090- 7.5 ton TPA120- 10 ton TSA180- 15 ton TSA240- 20 ton T Series Split Systems • Availability – CRDC to stock AC/HP and standard drive coil blower units – Build To Order (BTO) options • • • • (Factory installed but longer lead times) Low Static Drive (0”-0.8” static) High Static Drive (0.6”-1.2” static) Coil Coating (1.0”-1.8” static) • Voltage Options – 208/230, 3 ph, 460, 3 ph or 575, 3ph Commercial Split Systems • Many field installed options – – – – – – – – – – – UVC High end MERV Filtration Electric Heat Hot Water Economizer Hail Guards Coil Guards Return Air Grilles Float Switch Kit Freezestat Kit Low Ambient Control (0⁰F) Commercial Split Systems • Check spec sheets for details and ratings: TSA TAA Coil Blowers-Single/Dual (6-20 ton) TPA TAA Coil Blower (7.5, 10, 15 ton) TAA Air Handlers TAA 072- 6 ton TAA090- 7.5 ton TAA – Air Handlers Multi-Position (Up / Horizontal TAA 120- 10 ton TAA150- 12.5 ton TAA180- 15 ton TAA240- 20 ton Commercial Split Systems Fully Assembled Units Factory installed : • • • • • • Motors Pulleys Belts Controls Wiring TXV/s Mai TAA Air Handlers • Multi-Positional Air Handler – Vertical – Horizontal – Right/Left Mai TAA Air Handlers Unit Layout TAA Air Handlers All Sides Access Bearing/Blower Access Full Access Back Filter Access Blower Access Front TAA Air Handlers TAA- 50/50 Face Split Coil TAA (7.5-20 Ton) • Independent Circuits • Independent TXV’s • Manifold (field Supplied) for converting to single circuit • Access to refrigerant lines on both sides of cabinet Mai TAA Air Handlers Factory Static Options High static drive (BTO-extended lead time) ~1.0” – 1.8” @ 400cfm/ton Standard drive (Stocked) ~0.6” – 1.2” @ 400cfm/ton Low static drive (BTO-extended lead time) ~0” – 0.8” @ 400cfm/ton Mai n TAA Air Handlers Control Box • Fully assembled • Simple electromechanical controls • Field re-locatable Mai TAA Air Handlers Plastic Drain Pan Corrosion resistant Removable Relocatable Reversible Deep Sloped for no standing water • Float switch option • • • • • • Mai TAA Air Handlers MERV 10 or 16 Options • 16” x 25” filter size in all large split air handlers 6-20 ton • 5” Filter provides longer life • Installs easily with 2 replacement rails • MERV 16 can help qualify for LEED credits • Same size filters as residential units therefore readily available Mai TAA Air Handlers Blower Motor Can be removed/installed by one person Removal with 2 bolts TAA Air Handlers UVC Light Kits • Install within minutes/not hours (Requires 1 person to install) • No safety interlock switches to wire or install • Lamp assemblies snap in place (No screws necessary) • Ballast mount on outside of air handler for operation visibility •LED for power - standard •LED for light(s) - standard TSA/TPA Outdoor Units Compressor Accessibility • Compressors designed at front of unit for access • Also standard: – Loss of charge switches – High pressure switches – Filter driers Mai Small Split Systems Small Split Systems • Small Split System Overview – 3, 4 & 5 ton cooling capacities – 208/230 & 460 volt 3 phase – 1 year parts, 5 year compressor warranty • ACBX32 air handlers – Multiposition flexibility – One piece design for easy installation • May be disassembled into 2 separate sections for installation ease in tight spaces – Field installed electric heat kits- 10, 15 & 20 KW – Foil face cabinet insulation Small Split Systems • ACBX32 air handlers – Tool-less access to filter area for quick & easy service – Disposable frame type filter furnished & factory installed in rails in cabinet – High strength UV & heat resistant plastic drain pan for corrosion resistance with a dual pipe drain – Factory installed TXV Small Split Systems • 4SCU13 & 4SHP13 Outdoor Units – Full metal louvered panel coil guard protection • Panels remove with just 2 screws per panel for easy coil cleaning & service – Controls located in corner post for easy installation & service – Rounded corners for safety & attractive, clean appearance – Optional low ambient its available – Quiet Shift capable (4SHP units)