TAA Air Handlers

advertisement
K Series Packaged Units & Commercial
Split Systems- 2011
Overview
• Commercial Market Strategy
– Replacement Market Focus
• K Series Products
– KGA, KCA, KHA
• T Series Large Split Systems (6-20 ton)
– TSA, TPA, TAA
• Small Split Systems (3-5 ton)
– 4SCU13, 4SHP13, ACBX32
2010 Commercial Regional
Distribution Center (CRDC)
7 US & 2 Canadian CRDC’s for quick product access
C200 Calgary
CRDC
Brampton
CRDC
2010 Commercial Regional
Distribution Center (CRDC)
• In stock for quick
delivery or pickup
• Ship direct to job site
• Great for replacement
• Wide range of field
installed accessories
• Available factory
options
Regional
Distribution
Centers
Manufacturing Quality
Packaged Unit Overview
2-25 Ton Overview
• Tonnages
Gas / Electric
(KGA) = 2, 2.5, 3, 4, 5, 6, 7.5, 8.5, 10, 12.5, 15, 17.5, 20 & 25
Electric / Electric
(KCA) = 2, 2.5, 3, 4, 5, 6, 7.5, 8.5, 10, 12.5, 15, 17.5, 20 & 25
Heat Pumps
(KHA) = 2, 2.5, 3, 4, 5, 6, 7.5, 8.5, 10, 12.5, 15, 20
2-25 Ton Overview
• K Series replaces T Series Products
– K Series backward compatible to T Series
– K Series B Box units require a return air adaptor
plate
• Field & factory installed accessories available
– Lead time for some factory installed CTO
accessories
• Variety of roof curb styles and types available
• ASHRAE 90.1 Complaint
– Products meet 2010 efficiency
requirements
2-25 Ton Overview
• Serviceability Features
– Common Parts
– Plastic Drain Pans
– Color coded & continuously
marked wiring
– Fork slots on 3 sides with
rigging holes at the corners
– Large access panels
– Thermal expansion valve with
removable element
Large
Access
Panels
Fork Slots
Unit
Rigging
Box Size Overview
• A Box
– Gas Electric & Electric Cooling
– Heat Pump
• A+ Box
2-6 ton
2-5 ton
– “Stretched” A Box
• 8” taller, 13” longer, same depth
– Gas Electric
7.5 ton
• Single Circuit- 1 compressor
• Heating Capacity up to 150,000 BTUH
– Heat Pump
• Single Circuit- 1 compressor
6 ton
Box Size Overview
• B Box (7.5-12.5 ton)
• C Box (15-25 ton)
– Dual circuit 7.5 ton
– Multiple circuits
capacities
– 15 ton units- 2
– Gas Electric, Electric
compressors
Cooling & Heat Pump
– 17.5, 20, 25 ton units3 compressors
– Gas Electric & Electric
Cooling (15-25 ton)
15 ton unit
– Heat Pump (15-20 ton)
with 2
compressors
C Box Layout
Economizer Dampers
(optional)
Condenser Fans
Indoor Coil
Belt Drive Blower Motor
Compressors
Gas Heat
Section
Government Regulations
Accessories- Field Installed
Accessories- Field Installed
• Coil Protection
– Coil guards
– Hail guards
• Controls
– Smoke detectors
• Cooling Accessories
– Compressor crankcase heaters
– Low ambient kits
• Condensate Traps
– Copper
– PVC
Accessories- Field Installed
• Ceiling Diffusers
– Step down
– Flush
– Ceiling diffuser transitions used with roof curb
Accessories- Field Installed
• Electrical accessories
– Disconnect kits (Factory Also)
– GFI service outlet
• Horizontal Conversion
– Horizontal discharge kit
Accessories- Field Installed
• Gas Heating Accessories
– Bottom gas piping kit
– Combustion air intake & vertical vent extension
kits
– Low temperature vestibule heater
– LP kits
Accessories- Field Installed
• Indoor Air Quality
– UVC germicidal lamps
– High Efficiency MERV 8 & 13 filters on certain
models
– CO2 Sensors- Wall or plenum mount
Accessories- Field Installed
• Outdoor Air Options
– Outdoor air dampers(Factory Also) standard &
motorized
– Introduce up to 25% outdoor
air- required by local codes
– Power exhaust fans
Accessories- Factory Installed
Accessories- Factory Installed
• Build to Order on some factory installed
options
– 10-12 week lead time
• Corrosion Protection
– evaporator coil, condenser coil or both
• Hinged Access Panels
– economizer, filter, compressor, controls, heating,
blower sections
Accessories- Factory Installed
• Stainless Steel Heat Exchanger
– 15 year warranty
• Low & High Static Blower Drives
– Low static drives ideal for warehouses
– High static ideal for add on cooling
applications with existing ductwork
• Gas Heat Options
– Medium and high heat capability
• Voltage Options
– 208/230, 3 ph, 460, 3 ph or 575, 3ph
Accessories- Factory & Field Installed
• Economizers
– Provide outdoor air for cooling instead of
mechanical cooling- saves money on electrical
consumption- can introduce up to 100% outdoor
air
– Why use economizers?
• Reduce the need for mechanical cooling- save $ on
electrical consumption
• Some buildings need cooling all year long- people add
heat as well as computers & assembly processes
– ASHRAE Standards (90.1)
• Require economizers and/or a certain percentage of
outdoor introduction in commercial buildings in some
parts of the country
Accessories- Factory & Field Installed
Accessories- Factory & Field Installed
Accessories- Roof Curbs & Curb Adaptors
Accessories- Roof Curbs & Adaptors
• Roof curbs
– Cliplock (8, 14, 18, 24”)
– Hinged (8, 18, 24”)
– Standard (14, 24”)
• Roof curb adaptors needed for replacement
applications
– Allied Commercial unit replaces a competitive unit
– Existing roof curb remains on the roof
• Roof curb manufacturers can provide pricing and
lead times
– Old unit & replacement unit model numbers needed
Accessories- Roof Curbs & Adaptors
Commercial Sales Tools
Commercial Sales Tools
• Product Information & Learning Tools
– 1) Website
• http://www.allied-commercial.com
– 2) Commercial Catalogs
• Spec Sheets, Sales Brochure
– 3) E-Learning CD
• Audio & video tutorial of K Series product line
• Links to installation instructions & spec sheets
Commercial Sales Tools
www.allied-commercial.com
T Series Large Split Systems
T Series Split Systems
TSA – Condensing Units
TPA – Heat Pumps
TSA 072- 6 ton
TSA090- 7.5 ton
TSA 120S- 10 ton
TSA120D- 10 ton
TSA150- 12.5 ton
TPA090- 7.5 ton
TPA120- 10 ton
TSA180- 15 ton
TSA240- 20 ton
T Series Split Systems
• Availability
– CRDC to stock AC/HP and standard drive coil blower
units
– Build To Order (BTO) options
•
•
•
•
(Factory installed but longer lead times)
Low Static Drive (0”-0.8” static)
High Static Drive (0.6”-1.2” static)
Coil Coating (1.0”-1.8” static)
• Voltage Options
– 208/230, 3 ph, 460, 3 ph or 575, 3ph
Commercial Split Systems
• Many field installed options
–
–
–
–
–
–
–
–
–
–
–
UVC
High end MERV Filtration
Electric Heat
Hot Water
Economizer
Hail Guards
Coil Guards
Return Air Grilles
Float Switch Kit
Freezestat Kit
Low Ambient Control (0⁰F)
Commercial Split Systems
• Check spec sheets for details and ratings:
TSA
TAA Coil Blowers-Single/Dual
(6-20 ton)
TPA
TAA Coil Blower (7.5, 10, 15 ton)
TAA Air Handlers
TAA 072- 6 ton
TAA090- 7.5 ton
TAA – Air Handlers
Multi-Position (Up / Horizontal
TAA 120- 10 ton
TAA150- 12.5 ton
TAA180- 15 ton
TAA240- 20 ton
Commercial Split Systems
Fully Assembled Units
Factory installed :
•
•
•
•
•
•
Motors
Pulleys
Belts
Controls
Wiring
TXV/s
Mai
TAA Air Handlers
• Multi-Positional Air
Handler
– Vertical
– Horizontal
– Right/Left
Mai
TAA Air Handlers
Unit Layout
TAA Air Handlers
All Sides
Access
Bearing/Blower
Access
Full Access
Back
Filter Access
Blower Access
Front
TAA Air Handlers
TAA- 50/50 Face Split Coil
TAA (7.5-20 Ton)
• Independent Circuits
• Independent TXV’s
• Manifold (field Supplied) for
converting to single circuit
• Access to refrigerant lines
on both sides of cabinet
Mai
TAA Air Handlers
Factory Static Options
High static drive (BTO-extended
lead time)
~1.0” – 1.8” @ 400cfm/ton
Standard drive (Stocked)
~0.6” – 1.2” @ 400cfm/ton
Low static drive
(BTO-extended lead time)
~0” – 0.8” @ 400cfm/ton
Mai
n
TAA Air Handlers
Control Box
• Fully assembled
• Simple electromechanical controls
• Field re-locatable
Mai
TAA Air Handlers
Plastic Drain Pan
Corrosion resistant
Removable
Relocatable
Reversible
Deep
Sloped for no standing
water
• Float switch option
•
•
•
•
•
•
Mai
TAA Air Handlers
MERV 10 or 16 Options
• 16” x 25” filter size in all large
split air handlers 6-20 ton
• 5” Filter provides longer life
• Installs easily with 2
replacement rails
• MERV 16 can help qualify for
LEED credits
• Same size filters as residential
units therefore readily
available
Mai
TAA Air Handlers
Blower Motor
Can be
removed/installed by
one person
Removal with
2 bolts
TAA Air Handlers
UVC Light Kits
• Install within minutes/not hours
(Requires 1 person to install)
• No safety interlock switches to wire or
install
• Lamp assemblies snap in place (No screws
necessary)
• Ballast mount on outside of air handler
for operation visibility
•LED for power - standard
•LED for light(s) - standard
TSA/TPA Outdoor Units
Compressor Accessibility
• Compressors designed at front of
unit for access
• Also standard:
– Loss of charge switches
– High pressure switches
– Filter driers
Mai
Small Split Systems
Small Split Systems
• Small Split System Overview
– 3, 4 & 5 ton cooling capacities
– 208/230 & 460 volt 3 phase
– 1 year parts, 5 year compressor warranty
• ACBX32 air handlers
– Multiposition flexibility
– One piece design for easy installation
• May be disassembled into 2 separate sections for
installation ease in tight spaces
– Field installed electric heat kits- 10, 15 & 20 KW
– Foil face cabinet insulation
Small Split Systems
• ACBX32 air handlers
– Tool-less access to filter area for quick & easy
service
– Disposable frame type filter furnished &
factory installed in rails in cabinet
– High strength UV & heat resistant plastic
drain pan for corrosion resistance with a dual
pipe drain
– Factory installed TXV
Small Split Systems
• 4SCU13 & 4SHP13 Outdoor Units
– Full metal louvered panel coil guard protection
• Panels remove with just 2 screws per panel for easy
coil cleaning & service
– Controls located in corner post for easy
installation & service
– Rounded corners for safety & attractive, clean
appearance
– Optional low ambient its available
– Quiet Shift capable (4SHP units)
Download